Loading...
HomeMy WebLinkAboutProduct Approval (2) Q0TR1NrrYjERD 5.6.4.1 For mechanically attached Base Sheet,the maximum d sign pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(0 12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the elected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design p ofessional to resist the.elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, F Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117.' Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-2 9(January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation Tri-Built S/A HT TU Underlayment shall not be left exosed for longer than 180-days after installation. 5.8 Tile Slippage Limitations TAS 103 per FRS A TRI A HI 2 12 04-12 : When.loading roof tiles on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FORD RECT-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max.10-tile stack 6:12 Lugged Max.10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted,followed by 8 tiles high 6:12 on slope,as shown below) Tri-Built S/A HT TU Underlayment Lugged ,f �a • r.t Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6r"EDITION(2017)FBC NON-HVHZ VALUATION FL16048-116 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 5 of 6 TRINITY I ERD 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlavment or Tri-Built Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile applications: While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll, broom or hand-press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below,sealed in accordance with TRI-BUILT Materials Group,LLC requirements. When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Tri-Built S/A HT TU Underlayment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Gulfport, MS 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 6 of 6 Certificate of Authorization No.29824 CREEK 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017) Manufacturer: TAMKO BUILDING PRODUCTS Issued September 25, 2017 220 West 4`"Street Joplin, MO 64801 (417)624-6644 Manufacturing Plants: Joplin, MO Phillipsburg, KS Frederick, MD Dallas,TX Tuscaloosa,AL Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES Entitv Report No. Standard Year PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995 PRI,Construction Materials Technologies(TST5878) TAP-314-02-01 Zev 2 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995 UL LLC(TST9628) 02NK9507 ASTM D 3161 2016 UL LLC(TST9628) 04NK24366 ASTM D 3462 2010A UL LLC(TST9628) 05NK28006 ASTM D 6381 2008(2013)e1 UL 2390 ASTM D 7158 2011 UL LLC(TST9628) 06NK03898 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 08CA59132 ASTM D 3161 2016 UL LLC(TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 1OCA50498 ASTM D 3462 2010A UL LLC(TST9628) 1 OCA64882 ASTM D 3161 2016 UL LLC(TST9628) 11 NK14014 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 12CA24551 ASTM D 3161 2016 UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e1 UL LLC(TST9628) 4787043752 ASTM D 3161 2016 UL LLC(TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC(ANE11669) TBP15001.3 Calculations 2017 TBP15001.4 FL18355-R4 Page 1 of 11 This evaluation report is provided for State of Florida product approval unde Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance chan es throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 CREEK TAMKO BUILDING PRODUCTS ""' Asphalt Shingles TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION Elite Glass-Seal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4"x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Heritage® 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Joplin,Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Vintage® 17-1/2"x 40",ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage®Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.4 FL18355-R4 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. y CREAK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC INSTALLATION Elite Glass-Seal® Basic Wind Speed (Vit): Max. 194 ph (Frederick,Joplin& Basic Wind Speed(Vasa): Max. 150 ph Tuscaloosa) Deck(HVHZ): In accorda ce with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Glass-Seal new construction; Min. 15/32 in. plywood existing (Frederick,Joplin(Non- construction. HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accords ice with FBC requirements. Min.slope: 2:12 and i I accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed lith 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed ith 5-1/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"o "6 Nail Pattern"detailed below. NAILS NaiPng --------------- Area - --- - -- -- - - - - - -- - 5-118" Butt Edge Figure 1. Elite Glass-Seal& Glass-Seal 4 Nail Pattern (Non-HV Z only) NAILS . ... .... - - --------------- - 6-718" Nailing -_ -------------------- - - -- - - -- AM -------------------------- — - -------------------------------------------- 5=118" Butt Edge Figure 2. Elite Glass-Seal 8 Glass-Seal 6 Nail Pattern TBP15001.4 FL18355-R4 Page 3 of 11 This evaluation report is provided for State of Florida product approval unde Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance chanes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, rec)mmended use, or other product attributes that are not specifically addressed herein. M CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC Heritage® Basic Wind Speed(Wit): Max. 194 mph (Dallas, Frederick,Joplin, Basic Wind Speed (Vasd): Max. 150 mph Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Heritage®Premium new construction; Min. 15/32 in. plywood existing (Dallas, Frederick construction. Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 15/32 in. plywood or wood plank for Heritage®Woodgate new construction; Min. 7/16 in. OSB existing construction. (Dallas&Frederick) Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6'Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. FASTENERS NAIL ZON E COMMON BOND 6-1/8" EXPOSURE 6-5/8" 12-112" 12-3/81 -►h- 12-1/2" � Figure 3. Heritage®, Heritage®Premium, and Heritage®Woodgate (Dallas) 4 Nail Pattern (non-HVHZ only) FASTENERS NAIL ZONE /COMMON BOND 6-1� EXPOSURE 5-6/8" 1' �7-1/2' 7-112"-►f t 718" -7-112"-H*-7-112"11111� �—i" Figure 4. Heritage®& Heritage®Premium 6 Nail Pattern TBP15001.4 FL18355-R4 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC -NAIL'ZONE/ ASTENERS. ,. COMMONI OND.. 6 i18" 'El(pOSURE 5518" 1"''. �,7 1/2=j�-7,1/2��►�7=8I8.��_ ' . :112. 71'�2�_ :�1.,�; Figure 5. Heritage®W odgate 6 Nail Pattern -►I1"i7"i�--12=1/2"�; �. 12=1/2" ►i�"i'I"I�-. 'i .i 'i• i, i ® Common Bond FASTENERS r i C co o e ib 39-30!' I Figure 6. Heritage®, Heritage®Premium,& Heritage®Woodgate Alternate 6 Nail Pattern. PAINT" .. : . "r COMMON;: fEXP;OSURE' 't ACCEPTi4)3LE':.. FASTENER L'O'CATION ALONG"96 ­`,k F "GOMMON'B.ON '9:F ED FAST.ENE;W LO,CATI,O.N Figure 7. Heritage®ju caloosa) Expanded Nail Zone Nail patterns from Figures 3, 4,and 6 may be placec r in the nail zone as described above TBP15001.4 FL18355-R4 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance chances throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, ret mmended use, or other product attributes that are not specifically addressed herein. l CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC Heritage®Premium Basic Wind Speed(Vuit): Max. 194 mph (Frederick) Basic Wind Speed (Vasd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. . Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS COMMON BOND 5112" EXPOSURE 5" D E 1"� �— 11"--►�— 12" —►�+--11"—►� �-1" Figure 8. Heritage®Premium (Frederick) 4 Nail Pattern (non-HVHZ only) NAIL ZONE/ FASTENERS COMMON BOND fS� V 51j2" E] EXPOSURE 5" 'I f Figure 9. Heritage®Premium (Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC - Heritage®Woodgate Basic Wind.Speed(V„it): Max. 194kh. h (Frederick) Basic Wind Speed(Vasd): Max. 150 Deck(Non-HVHZ): In accord nce with FBC.requirements; Solidly sh athed min. 15/32 in.,plywood or wood plank for _.new const uction; Min. 7/16 in. OSB existing construction. Underlayment: In accordEnce with FBC requirements. _Min.slope: 2:12 and in accordance.with FBC requirements. Refer to the manufacturer's application instructions when installing shingles a slopes greater than 21:12. Installation (Non-HVHZ): Installed with 5 "in. exposure in accordance with FBC requireme its and manufacturer's published installation instruction 3. Shingles shall be attached using either'A Nail Pattern"o "6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS COMMON BOND T 5-112 EXPOSURE 5" 1'=rl 11" ,►�-12-3/8" Figure 10. Heritage®Woodg to(Frederick) . 4 Nail Pattern (non-HV Z only) NAIL ZONFI COMMON BOND FASTENERS t 5'1!2" EXPOSURE 5" 1"—►I ,EF• 9-112" -3' --93/8"- 3'+I�F -112"-►I �-1" i • Figure 11. Heritage®Woodg to(Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 7 of 11 This-evaluation report:is provided for State of Florida product approval unde Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance chang s throughout the duration for which this report is valid. This'evaluation report does not express nor imply warranty, installation, rec installation, use, or other product attributes that are not specifically addressed herein. r CREAK TAMKO BUILDING PRODUCTS K Asphalt Shingles TECHNICAL SERVICES, LLC Heritage®Vintage® Basic Wind Speed (Wit): Max. 194 mph (Phillipsburg) Basic Wind Speed (Vasa): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"5 Nail Pattern"or T Nail Pattern"detailed below. 40, i; Aign—t Exposure -2 "�°f Notch 6„ Fasteners Nail one — — — — — — — — — — 17.1J2" S" Exposure ¢IAC 9•IN' 9.114'—��9-iv Figure 12. Heritage®Vintage® 5 Nail Pattern (non-HVHZ only) � �0611R FasLett[R Noll — — — Zone 17-1/2` Bgmsutr >a7Ji'-r�. I �1FI�S7I8' Figure 13. Heritage®Vintage° 6 Nail Pattern TBP15001.4 FL18355-R4 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC Hip&Ridge Basic Wind Speed(Vuit): Max. 194 ph (Frederick&Joplin) Basic Wind Speed(Vasa): Max. 150 ph Deck(HVHZ): In accorda ce with FBC requirements; Solidly she thed min. 19/32 in. plywood or wood plank for new con truction; Min. 15/32 in. plywood existing constructio . Deck(Non-HVHZ): In accords ce with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new constriction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5-1/8 inch exposure in accordance with the FBC andmanufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. i Direction of prevailing wind tart �5-1/8" exposure ere _I II Start Figure 1 here 5-1/8"exposure lip Fastener Fastener h' r'`5-5J8,� Figure-21/411 Figure 3 Figure 14. Hip& Ridge(Frederick&Joplin) TBP15001.4 FL18355-R4 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply,warranty,_installation, recornmended use, or other product attributes that are not specifically addressed herein. ,�.- GREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC Vintage®Hip&Ridge Basic Wind Speed(V„it): Max. 194 mph (Phillipsburg) Basic Wind Speed(Vwd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction of prevailing wind hStarrt 5�" exposure FW— I II MStart a 5" exposure Figure 1 1" Fastener ��I Fast®ner 5-1/253 Figure 2 14 Figure 3 Figure 15. Vintage®Hip& Ridge (Phillipsburg) TBP15001.4 FL18355-R4 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be desig ied by others to meet the minimum design loads established for components and cladding and in accordanc with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 f in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B&C m ith a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irr gularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to under ayment application. 6) Shingles shall be installed starting'at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies a ist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6`h Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. xN •E sF•�s,'- �.._ _ ti... ..M..u.2017.09.25 No 74021 = 11 :31 :41 �- -04'00' � :• STATE OF -i-T•'•'c� O P ���.` Zachary R. Priest, P.E. OR k -, ONA%,��•�`,, O Flori ga zation No.lANE11669 on No. 1 �nnn� CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have,nor will it acquire,a financi I interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in 3ny other entity involved in the approval process of the product. END OF REPORT TBP15001.4 FL18355-R4 Page 11 of 11 This evaluation report is provided for State of Florida product approval unde Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance Chang as throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein.