Loading...
HomeMy WebLinkAboutProduct Approval - shingles Planning & Development Services Department COUNTY �■ Building & Regulations Division _L 0 R I D A Product Review Affidavit Building Permit# Owners NameKatherine Ross Applicant: Robin Cable Product Opening Design Product Rated Manufacturer Model Number Product Approval Glass Method of Attachment Pressures Design Pressure Number Type Windows Mullions Fixed Glass Block Glass Skylights Sliding Glass Doors Swing Type Doors French Doors Garage Doors Hurricane Protection Roof Ventilation Roofing Material USS �� IOIo`1y 1fkikea Co r A,.,A o, 'R 13 Revised 07/22/2014 I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: Signature: seal Design Prof: Cert. No. Date: Horida Building Code Online Page 1 of 2 P ° • rid ' BC1S Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts _ Publications Contact Us SCIS Site Map ! Links Search000 ! r Product Approval USER:Public User Produc-Approval Menu>Product or Anrlicat,on Search>Application I.:st>Application Detail oilµa3 I �•�• � FL# FL10674-R13 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W.Knezevich,PE * Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R13 COI 2017 01 COI Nielninen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%... 7/26/2018 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ:No I FL10674 R13 II 2017 10 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.Ddf Impact Resistant: N;A Verified By: Robert J. M.Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other: Refer to ER,Section 5. I Evaluation Reports FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT .INGLES FL10674-R'_3.odf Created by Independent Third Party: Yes Back Nest Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::&ivacv Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses arc public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please Chick he_gr,-. Product Approval Accepts: " Eii ® Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtBNbEY5 V%... 7/26/2018 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 TRINITY ` 353 CHRISTIAN STREET,UNIT#13 ERD OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R8 One Owens Corning Parkway FL10674-1113 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404-7829 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: P '03 OF Robert J.M.Nieminen,P.E. �'•-Fs"^"rr' ,' The facsimile seal appearing was authorized by Robert Florida Registration N0.59166,Florida DCA ANE1983 "W" Nieminen,P.E.on 10/09/2017.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity]ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity l ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY J ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R90S.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Eniint Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic'and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire`"are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition' Duration', Duration' Premium Cool, TruDefinition' Duration' Designer Color Collection, TruDefinition'Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shingles: 4.2.1 Berkshire' Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge'" Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: S.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate ofAuthorization!l9503 6' EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 TRINITY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (V,,,, = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd= 150 mph (V,,,,= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 611320-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire*shingles require minimum five(5)nails per shingle. WeatherGuard HP shingles require minimum six(6)nails per shingle. ➢ Devonshire'shingles require minimum six(6)nails per shingle. L Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Fele undedayinern —Deck Fek widerbyrimit Oee! S�R+dlrae MlaN6elaeig9 Self-adhered und�fat Weotherlock° underlayment Drip Drip edge � OrIP %. Nails located r from aae 2"-3"from eave kistan first W-see6ng adhesive Nsti rvst Starter Snip PMn 4�^9 a�4 Starters positioned along eave with � � 0 �iDam shingle= 6'removed Starter Strip shingle overhangs eaves and rakes i`-'i" Swrtr S*%a orKhrp eavatmad rake u'-V4' Exterior Research and Design,LIC. Evaluation Report 037940.02.12-118 CertificateofAuthori:otion#9S03 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 O TRINITY ERD 6.2.6 Minimum Nailing—Classic®&Supreme: rr Mansard or Area para Nar ,a) kgansard or ,�rsa+tas High M od dssvanes y Wind Areas High tJriad dasvaneea vmntos nornmko Areas vi. trims Area para vianios normslas Are" vaaetos fk atlas j IL ure Is 418"Exposure k"a EgwsiriaSr► 6.2.7 Minimum Nailing—Berkshire®: Sxabnf strip Sadant Strip La fire do%M-dar Latta de soNsdor t s svf 81W stip j ` a,�. 8"2 s%• 8W / t• t`1 t• t"1 r r r Standard Fastening Pattern 6-Nail Fastening Pattern Srabnt strip La tka do odkdw t•A f 8 Yf S Yf 8 t'f t" a a r Aaytok roofingcement ' CeaaBoto da!oeho do astd+r Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118 Certificate of Authori:ation#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 -FY ;F-KD "j TRINI 6.2,8 Minimum Nailing—Devonshire—: I I Nefts 5s/8'exposure Sealant location Exposici6n de 5.518 pulp Ubicad6n del sellador Ten t"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition' Duration Designer Color Collection: "an Fasten"Pattern 6-NM Festwft PaMern F K TIP"Ca 12" 12" 12' -1-1tr 7 PI T_ u, 6.12 Standard Fastening Pattern 6-Nail Fastening Pattern FastenkV for Slopes Greater Then 21:12 1kk.T"kd Ir 12- Fl. Ljr Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118 Certificate of Authorization#9S03 67"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 5 of 8 TRINITY I ERD 6.2.1 Minimum Nailing-Tru Definition'Oakridge®,Oakridge®: 4 Nail Patten 6 Nail PAtsm EsWom con 4 ciaes Esquerrur cm 6 daws r 6 5ff Exposure6 519'Exposure Nalls W6 ap*a"do 5 54 pdq. Cbvm Exoosid6rr&6 5/9*g 5 5 8 Expostim CAAM 5 fiAr Exposure Efpa"M de 55/0 ptdg Exposlaidn de 55/9p dq� Standard Fastening Pattern 6-Nail Fastening Pattern F"Ie"for Stopes Greater Than 21:12 f- Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing-WeatherGuardO HP: 11111111111106 aft V%W 1 PMNMW7 MIR*1" 11110 Ah Out Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate ofAutharization#9503 6-EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 ( i TRINITY ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, WeatherGuard* HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidge^' Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: 1 Flp.1 v4i Fip.4 OYaa{611 \. i RpVls StleNa+ \ I Nals Ndis `ib TopLamdamad Mats 1 \�\A\ 1 I 4 I I I �� i1 f V V 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.As v Fig.C Hip&Ridge Shingle Fastening Prawsng wineNails •. ��'• Top View Dmetba P\ Z.. �—Exposero Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 TRINITY I ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: PrevaAing Standard 19•_, Wind Direction Fastening Stellntt Strgt ., Pattern �— b" p� t2• � i Fasten 71h• 1'" fi"E>fRserre \ F�tamn with +I Roof Cement —12•- 6.3.6 Minimum Nailing–DuraRidge" Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Pravaifne V"Dkwdm Top vaso 'f—t)eaaiiendcrtairsaariavamvee Din " cddn dd iimb pradonwa wa li- vee ugerlor 1 I I - _T Nam.. aa,. mails `�, • arwr saarNaC • F I I I ,.s;,. I I j •lb lit 4 1 i i rill v 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC–QUA9625;(631)546-2458; Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-118 Certificate of Authorization#9503 67'EDITION 12017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8