Wind Load Calculation
M Property Information Building Information Owner: ALAN&REBECCA GREGORY Wind Zone: 170 MPH. Address: 5195 TREE TOP TRL Exposure Category: C FT.PIERCE,FL 34951 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psfl Pressure(psf) 1 Int 71.75 18.25 7 37.4 -40.6 2 Int 35.75 79.125 7 36.1 -39.3 3 Int 25 24.5 7 37.8 -41.0 4 Int 17.875 61.75 7 37.8 5 Int 17.875 61.75 7 37.8 -41.0 ..................................- .._-._-._...............- ---_.... ......_........................--------. -........._......- --- 6 Int 105.5 79.5 7 33.5 -36.7 -- -. -...... _ 7 Int 105.5 79.5 7 33.5 -36.7 8 Int 35.75 36.5 7 37.8 -41.0 9 Int 25.25 48.75 7 37.8 -41.0 10 Int 52 48.5 7 36.4 -39.6 11 Int 105.5 79.5 7 33.5 -36.7 12 Int 35.5 61.5 7 36.8 -40.0 13 Int 35.5 61.5 7 36.8 -40.0 14 Int 24.25 24.25 7 37.8 -41.0 15 Int 35.75 61.5 7 36.8 -40.0 16 Int 35.75 61.5 7 36.8 -40.0 17 Int 35.75 61.5 7 36.8 -40.0 18 Int 25.75 61.25 7 37.6 -40.8 19 Int 25.75 15 7 37.8 -41.0 20 Int 35.75 61.25 - 7 36.8 -40.0 21 Int 35.75 15 7 37.8 -41.0 FILE COPY Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page I of 1