HomeMy WebLinkAboutDiIorio Jim Mitsubishi mini-split eqpmt specs08162018Indoor Unit: MSZ-HMI2NA-Ul Wireless Remote Controller Outdoor Unit: MUZ-HMI2NA-U1 ACCESSORIES: Indoor Unit n Condensate Pump (BlueDiamond X87-711/721; 115/230V) n Condensate Pump (Sauermann S130-115/230; 115/230V) r, Anti -Allergy Enzyme Filter (MAC-408FT-E) o Drain Pan Level Sensor (DPLS2) Outdoor Unit ❑ Outdoor Mounting Pad (ULTRILITEI) u Drain Pan Heater (MAC-64OBH-U) ❑ 3-1/4" Mounting Base [Pair] (DSD -400P) ❑ Drain Pan Socket (MAC-860DS) ❑ Air Outlet Guide (MAC-889SG) ❑ Wali Mounting Bracket (QSWB2000M-1) SPECIFICATIONS: Compressor DC INVERTER -driven Twin Rotary Fan Motor (ECM) F.L.A. 0.5 Indoor DRY 170-237-321-399 (Cooling) WET 134-201-286-364 Indoor CFM (Heating) DRY 170-237-321-406 Outdoor u 1,243 / 1,229 Cooling 22-30-37-45 Indoor Cooling' BtumHeating /w i 12,000 / 1,210 d6(A) 22-30-37-43 Cooling 49 Heating at 47° Fz Btu/h / W 12,200/990 Outdoor Heating 51 Cooling' Btu/h 3,800 12,200 Heating at 47° Fz Btu/h 4,500 14,500 Heating at 17° F3 Btufh - 9,000 Heating at 5° F4 Btu/h 7,500 ' Coding i Indoor: 80° F(27° C)OB / 67° F(190 C)WS; Outdoor: 95° F(35° C)DB / 75° F(24° C)WB' Heating at 47°F i Indoor: 70° F (21° C)DB / 60° F (16° C)WB; Outdoor: 47° F (8° C)DB /430 F (6° C)WB' ' Heating at 17° F i Indoor: 70° F(21° C)DB / 60° F(16° C)WB; Outdoor: 17° F(-8° C)DB ! 15° F(-9° C)WB' ' Heating at 5° F I Indoor. 70° F (210C)DB/600 F(16° C)WB; Outdoor: 5° F(-15° C) DB / 5° F(-15° C)WB ' Rating Conditions per AHRI Standard: I ndoorD) 11-5/8 x 31-7/16 x 9-1/8 (295 x 798 x 232) In.(mm) x D) 21-5/8 x 31-1/2 x 11-1/4 (550 x 800 x 285) Indoor 22 (10) Lbs.(kg) Outdoor 1 73 (33) +. - Cooling 90° F (32° C) DB / 67° F (19° C) DB Indoor Munsell 1.OY 9.2 / 0.2 Heating 80° F (27° C) DB / 70° F (21° C) DB - Outdoor Munsell No. 3Y 7.8 / 1.1 Cooling" 115 F (46° C) DB / 14° F (-10° C) DB R410A; 1 Ib. 12 oz. I Heating 75° F (24° C) DB / -4° F (-20° C) DB" Refrigerant Piping Applications should be restricted to comfort coding only; equipment cooling applications are not Liquid (High Pressure) recommended for low ambient temperature conditions. In.(mm) — " System cuts out at -9" F (-27" C) to avoid thermistor error and automatically restarts at .4" F (.20o C). Gas (Low Pressure) 3/8 (9.52) Max. Total Refrigerant 40 (12) Pipe Length (Height Diff.) SEER / EER / HSPF 18.0 / 9.9 / 10.0 — , Ft (m) Max. Total Refrigerant ( ) COP at 47° F / 17° F 3.61 / 2.78 Pipe Length (Length.) 65 20 208 / 230V, 1 -Phase, 60 Hz MInInium Circuit Ampacity (MCA) Indoor/ Outdoor A Specifications are subject to change without notice. 0 2017 Mitsubishi Electric US, Inc. MSZ-HM12NA-U1 +It � 'l'�a�aaa®u�aaa�■a� Ill�w�l��ll���■il Air in Unit: in. (mm) M UZ-H M 12NA-U 1 REQUIRED SPACE '1 4 in. (too mm) or more when front and sides of the unit are clear( •2 When any 2 sales of left right and rear of the unit are dear FORM# MSZ-HM12NA-U1 ( MUZ-HM12NA-U1 - 201705 Unit: in. (mm) MITSUBISHI Alr` ELECTRIC COOLING & HEATING 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com c ETV u5 Intertek Specifications are subject to change without notice. 0 2017 Mitsubishi Electric US, Inc. Insulation e1 -3/8 0.13 Liquid line at/4 19 - 11/16 (Flared connection e1/4) CL Gas line e3/8 16 - 15/16 (Flared connection, o3/8 (HMO9112NA , e1/2 (HM15N Drain hose Insulation of -118 0.13 Connected W e5/6 O.D Unit: in. (mm) MITSUBISHI Alr` ELECTRIC COOLING & HEATING 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com c ETV u5 Intertek Specifications are subject to change without notice. 0 2017 Mitsubishi Electric US, Inc. 1-2. SELECTING THE INSTALLATION LOCATION • Where airflow is not blocked. Where cool (or warm) air spreads over the entire room. On a rigid wall to reduce the possibility of vibration. Where it is not exposed to direct sunlight. Do not expose to direct sunlight also during the period following unpack- ing to before use. • Where it can be easily drained. At a distance 3 ft. (1 m) or more away from a TV and radio. Operation of the air conditioner may interfere with radio or TV reception. An amplifier may be required for the affected device. • In a place as far away as possible from fluorescent and incandescent lights. In order to make the infrared remote control operate the air conditioner normally. The heat from the lights may cause deformation or the ultraviolet may cause deterioration, Where the air filter can be removed and replaced easily. Where it is away from the other heat or steam source. Note: Install the indoor unit high on the wall where air can distribute over the entire room. • Where it is convenient to operate and easily visible. Where children cannot easily touch it. Select a position about 4 ft. (1.2 m) above the floor. Check that signals from the remote controller from that position are received by the indoor unit ('beep' or'beep beep' receiving tone sounds). Then, attach remote controller holder to a pillar or wall and install wireless remote controller. 1-3. SPECIFICATIONS Note: In rooms where inverter type fluorescent lamps are used, the signal from the wireless remote controller may not be received. • •+•EIIIIIIIII Where it is not overly exposed to strong winds. If the outdoor unit is exposed to a wind during defrosting, the defrosting time will be longer. Where airflow is good and dustless. Where neighbours are not annoyed by operation sound or hot (or cool) air. Where rigid wall or support is available to prevent the increase of operation sound or vibration. Where there is no risk of combustible gas leakage. If installing the unit in a location high above the ground, be sure to secure the unit legs. Where it is at least 10 ft. (3 m) away from the antenna of TV set or radio. Operation of the air conditioner may interfere with radio or TV reception in areas where recep- tion is weak. An amplifier may be required for the affected device. Install the unit horizontally. Please install it in an area not affected by snowfall or blowing snow. In areas with heavy snow, please install a canopy, a pedestal and/or baffle boards. 1.3-1. POWER SUPPLY AND INDOOR/OUTDOOR WIRE CONNECTION Power should be taken from an exclusive branched circuit. Wiring work should be based on applicable technical standards. Wiring connections should be made following the diagram. Securely tighten screws. Connecting wires and the ground wire Use solid conductor Min. AWG14 or stranded conductor Min.. AWG14. Use double insulated copper wire with 600 V insulation. Use copper conductors only. Follow local electrical codes. Power supply cable and ground wire • Use solid or stranded conductor Min. AWG14. Use copper conductors only. Follow local electrical codes. Note: When the indoor unit is powered from the outdoor unit, depend- ing on local code, a disconnect switch needs to be installed to a power supply circuit. 1-3-2. REFRIGERANT PIPES To prevent condensation, insulate the two refrigerant pipes. Refrigerant pipe bending radius must be 4 in. (100 mm) or more. 0 CAUTION Be sure to use the insulation of specified thickness (table on the right). Excessive insulation may cause incorrect installation of the indoor unit, and too little insulation may cause condensate to form. • The unit has flared connections on both indoor and outdoor sides. Remove the valve cover from the outdoor unit, then connect the pipe. • Refrigerant pipes are used to connect the indoor and outdoor units. Be careful not to crush or over bend the pipe in pipe bending • Refrigerant adjustment.., If pipe length exceeds 25 ft. (7.5 m), additional refrigerant (R410A) charge is required. (The outdoor unit is charged with refrigerant for pipe length up to 25 ft. 17.5 mj) Electrical specifications Note: It is advisable to make a piping loop near outdoor unit so as to reduce vibration. For increased efficiency, install the outdoor unit in a location where continuous direct sunlight or excessive water can be avoided as much as possible. Note: When operating the air conditioner in low outside tem- perature, be sure to follow the instructions described below. Never install the outdoor unit in a place where its air inlet/outlet side may be exposed directly to wind. To prevent exposure to wind, install the outdoor unit with its air inlet side facing the wall and a baffle board on the air outlet side. Avoid the following places for installation where air conditioner trouble is liable to occur. Where flammable gas could leak. Where there is an excessive amount of machine oil in the air. Where oil is splashed or where the area is filled with oily smoke (such as cooking areas and factories, in which the properties of plastic could be changed and damaged). Salty places such as the seaside. Where sulfide gas is generated such as hot spring, sewage, waste water. • Where there is high -frequency or wireless equipment. Where there is emission of high levels of VOCs, includ- ing phthalate compounds, formaldehyde, etc., which may cause chemical cracking. MODEL MSZ-HM09NA MSZ-HM12NA MSZ-HM15NA HV>rtiCM]R UN r thickness thickness Insulation material Power supply (V, PHASE, Hz) inch (mm) 208/230, 1, 60 (Refer to the table below.) Min. Circuit Ampacity iA, 0.0315 (0.8) 1.0 Heat resistant foam plastic 0.045 Fan motor (F.L.A.) (Ai 1/2(12.7) 0.76 5/16 8 OUT004DA LW11*,1 Power supply (V, PHASE, Hzj 208/230, 1, 60 Max. Fuse size time dela ) 1& 15 1 15 1 15 Min. Circuit A acit jAi 12 12 10 Fan motor (F.L.A.1 tAi 0.50 0.50 0.50 Compressor (R.L.A) (A)MSZ (L.R.A) (A) 6.6 6.6 7.4 I MSZ 8.2 8.2 9.3 Control voltage Indoor unit- Remote controller- (Wireless) Indoor unit - Outdoor unit: DC12-24 V (Polar? Outside diameter Minimum wall Insulation Pipe length Pipe thickness thickness Insulation material inch (mm) (Refer to the table below.) For liquid 1/4(6 0.0315 (0.8) 5/16(8) Heat resistant foam plastic 0.045 Forges 3/8 (9.52) 0.0315 t0.8) 5/16(8) 1/2(12.7) 0.0315 10.8) 5/16 8 Specific gravity Limits Pipe length 65 ft. (20 m) max. Height difference 40 ft. (12 m) max. No. of bends 10 max. Up to 25 ft. (7.5 m) No additional charge is required. Pipe length Exceeding 25 ft. (7.5 m) Additional charge is required. (Refer to the table below.) Refrigerant to be added 1.08 oz each 5 ft. 20 /m ( 9 )