Loading...
HomeMy WebLinkAboutProduct Approval (2) Certificate of Authorization No. 29824 CREEK 17520 Edinburgh Drive Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 6T"EDITION(2017) Manufacturer: TRI-BUILT Materials Group Issued February21, 2018 9050 Louisiana Street Merrillville, IN 46410 (800)516-1485 www.tribuiltmaterials ro .com RECEIVED Quality'Assurance: Intertek Testing Servic (QUA1 $6� 16 201$ SCOPE ucY, P Category: Roofing Subcategory: Undedayments Code Sections: 1507.1.1, 1518.4 Properties: Physical properties REFERENCES Enti Report No. Standard Year Intertek Testing Services(TST1585) 102074565COQ-004 AC 188' 2012 Intertek Testing Services(TST1585) 102074565COQ-004A AC 188' 2012 Intertek Testing Services(TST1585) 102074565COQ-007 ASTM D 226 2009 Intertek Testing Services(CER1497) CCRR-1045 IBC,IRC 2012 PRI Construction Materials Technologies(TST5878) CMI-048-02-01A ASTM D 226 2009 PRI Construction Materials Technologies(TST5878) CMI-048-02-01 B ASTM D 226 2009 PRI Construction Materials Technologies(TST5878) CMI-048-02-OIC ASTM D 226 2009 PRI Construction Materials Technologies(TST5878) CMI-055-02-01 ASMT D 4533 2015 PRI Construction Materials Technologies(TST5878) CMI-056-02-01 ASMT D 4533 2015 'Determined to be equivalent to ASTM D 226(2009),Type 1 and II PRODUCT DESCRIPTION Tri-Built Synthetic 10 A mechanically attached, woven polypropylene underlayment (nominal weight = 1.74 Roof Underlayment Ib/100fe) used an alternative to ASTM D 226, Type I and Type 11 with a minimum tear strength per ASTM D 4533 of 20 pounds. The underlayment is available in rolls 48-inch wide by 250-ft long. Tri-Built Synthetic 25 A mechanically attached, woven polypropylene undedayment (nominal weight = 2.05 Roof Underlayment tb/100fe) used an alternative to.ASTM D 226, Type 1 and Type 11 with a minimum tear strength per ASTM D 4533 of 20 pounds.The underiayment is available in rolls 48-in6h wide by 250-ft long. Tri-Built Synthetic Plus A mechanically attached, woven polypropylene underlayment (nominal weight = 2.46 Roof Underlayment Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear (i strength per ASTM D 4533 of 20 pounds. The undedayment is available in rolls 48-inch C wide by 250-ft long. Tri-Built Synthetic MAX A mechanically attached, woven polypropylene underlayment (nominal weight = 3.69 Roof Underlayment Ib/100fe) used an alternative to ASTM D 226, Type I and Type II with a minimum tear strength per ASTM D 4533 of 20 pounds. The underlayment is.available in rolls 48-inch wide by 250-ft long. TBM16001.1 FL21553-R1 'Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC-of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. s TRI-BUILT MATERIALS GROUP CREEKSynthetic Underlayments TECHNICAL SERVICES,LLC APPLICATION INSTRUCTIONS Deck Type: The roof deck shall be constructed of closely fitted,solid sheathing for new or existing construction. Sheathing shall be installed in accordance with FBC requirements. New construction.in the HVHZ shall be minimum 19/32-inch plywood. Roof decks shall have no more than 1/8-inch,gap at abutting joints. Attachment method Undedayment shall be attached in accordance with the FBC Table 1507.1.1 and _ (non-HVHZ): manufacturer's installation instructions. Attachment method Underlayment shall be installed with a minimum 4-inch head lap and minimum 6-inch (HVHZ): end lap and be fastened as specified in FBC Section 1518.2. Allowable roof coverings Mechanically attached roof systems,as prescribed in FBC Section 1507.1.1. (Non-HVHZ): Allowable roof coverings Underlayment.shall be used with mechanically attached asphalt shingles, metal roof (HVHZ): panels and shingles,composite shingles and wood shingles and shakes LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift:resistance is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 5) Roof slope limitations shall be in accordance with FBC requirements. 6) All underlayments shall be installed with the roll length parallel to the eave,starting at the eave,and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. 7). The underlayment may be used as described in other current FBC product approval documents. 8) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 9) The underlayment shall not be installed over existing roof coverings. 10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. TBM16001.1 FL21553-R1 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer.shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEKTRI-BUILT MATERIALS GROUP Synthetic Underlayments TECHNICAL SERVICES,LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. 1'����►11 nni���r . E N %s 2018.02.21 '•� j 13:42:11 No 74021irZ;. • 1 . = .. .. -051001 STATE OF 00'0'n'•'c ' �:~~ Zachary R. Priest, P.E. �F�,Vn•�•O R 10. �,`�� Florida Registration No.74021 �l111�ONA— 't Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial Interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBM16001.1 FL21553-R1 'Page 3 of 3 This evaluation report_is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shah notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration far which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. Certificate of Authorization 29824 CREEK17520 Edinburgh Drive Tampa,FL 33647 TECHNICAL. SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 6T"EDITION(2017) Manufacturer: TRI-BUILT Materials Group Issued February 21,2018. 9050 Louisiana Street Merrillville,IN 46410 (800)516-1485 www.tdbuiltmaterlaisgroup.com Quality Assurance: Intertek Testing Services(QUA1586) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1,1518.4 Properties: Physical properties REFERENCES Enti W Report No. Standard Year Intertek Testing Services(TST1585) 102074565COQ=004 AC 188' 2012 Intertek Testing Services(TST1585) 102074565COQ-004A AC 188' 2012 Intertek Testing Services(TST1585) 102074565COQ-007 ASTM D 226 2009 . Intertek Testing Services(CER1497) CCRR-1045 IBC,IRC 2012 PRI Construction Materials Technologies(TST5878) CMI-048-02-01A ASTM D 226 2009 PRI Construction Materials Technologies(TST5878) CMI-048-02-01B ASTM D 226 2009 PRI Construction Materials Technologies(TST5878) CMI-048-02-OIC ASTM D 226 2009 PRI Construction Materials Technologies(TST5878) CMI-055-02-01 ASMT D 4533 2015 PRI Construction Materials Technologies(TST5878) CMI-056-02-01 ASMT D 4533 2015 'Determined to be equivalent to ASTM D 226(2009),Type I and II PRODUCT DESCRIPTION Tri-Built Synthetic 10 A mechanically attached, woven polypropylene underlayment (nominal weight = 1.74 Roof Underlayment Ib/1001tz) used an aftemative to ASTM D 226, Type I and Type II with a minimum tear strength per ASTM D 4533 of 20 pounds. The undedayment is available in rolls 48-inch wide by 250-ft long. Tri-Built Synthetic 25 A mechanically attached, woven polypropylene underlayment (nominal weight = 2.05 Roof Underlayment Ib/100f?) used an alternative to ASTM D 226, Type I and Type II with a minimum tear strength per ASTM D 4533 of 20 pounds.The,underlayment is available in rolls 48-inch wide by 250-ft long. Tri-Built Synthetic Plus A mechanically attached, woven polypropylene undedayment (nominal weight = 2.46 Roof Underlayment Ib/100ftz) used an alternative to ASTM D 226,Type I and Type II with a minimum tear strength per ASTM D 4533 of'20 pounds. The underlayment is available in rolls 48-inch wide by 250-ft long. Tri-Built Synthetic MAX A mechanically attached, woven polypropylene undedayment (nominal weight = 3.69 Roof Underlayment lb/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear strength per ASTM D 4533 of 20 pounds. The underlayment is available in rolls 48-inch wide by 250-ft long. TBM16001.1 FL21553-R1 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not specifically addressed herein. TRI-BUILT MATERIALS GROUP (CREEK Synthetic Underlayments TECHNICAL SERVICES,LLC APPLICATION INSTRUCTIONS Deck Type: The roof deck shall be constructed of closely fitted,solid sheathing for new or existing construction. Sheathing shall be installed in accordance with FBC requirements. New construction in the HVHZ shall be minimum 19132-inch plywood. Roof decks shall have no more than 1/8-inch gap at abutting joints. Attachment method Underlayment shall be attached in accordance with the FBC Table 1507.1.1 and (non-HVHZ): manufacturer's installation instructions. Attachment method Undedayment shall be installed with a minimum 4-inch head lap and minimum 6-inch (HVHZ): end lap and be fastened as specified in.FBC Section 1518.2. Allowable roof coverings Mechanically attached roof systems as prescribed in FBC Section 1507.1.1. (Non-HVHZ): Allowable roof coverings Underlayment shall be used with mechanically attached asphalt shingles, metal roof (HVHZ): panels and shingles,composite shingles and wood shingles and shakes LIMITATIONS ' 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to undedayment application. 5) Roof slope limitations shall be in accordance with FBC requirements. 6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave,and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck.- 9) The underlayment shall not be installed over existing roof coverings. 10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. TBM16001.1 FL21553-R1 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TRI-BUILT MATERIALS GROUP CREEKSynthetic Underlayments TECHNICAL SERVICES,LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6t'Edition(2097)as evidenced in the referenced documents submitted by the named manufacturer. PaY R. p 2018.02.21 No 74021 = 13:42:11 _ -05'00' :P STATE OF %�•c�••.'c P.' .4(,:� Zachary R. Priest,P.E. E��`�, Florida Registraon No. N ALOrganization Notl ANE9641021 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial Interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBM16001.1 FL21553-R1 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein.