EVALUATION REPORT FLORIDA BUILDING CODE 6T"EDITION(2017)
Manufacturer: TRI-BUILT Materials Group Issued February21, 2018
9050 Louisiana Street
Merrillville, IN 46410
(800)516-1485
www.tribuiltmaterials ro .com RECEIVED
Quality'Assurance: Intertek Testing Servic (QUA1 $6� 16 201$
SCOPE
ucY, P
Category: Roofing
Subcategory: Undedayments
Code Sections: 1507.1.1, 1518.4
Properties: Physical properties
REFERENCES
Enti Report No. Standard Year
Intertek Testing Services(TST1585) 102074565COQ-004 AC 188' 2012
Intertek Testing Services(TST1585) 102074565COQ-004A AC 188' 2012
Intertek Testing Services(TST1585) 102074565COQ-007 ASTM D 226 2009
Intertek Testing Services(CER1497) CCRR-1045 IBC,IRC 2012
PRI Construction Materials Technologies(TST5878) CMI-048-02-01A ASTM D 226 2009
PRI Construction Materials Technologies(TST5878) CMI-048-02-01 B ASTM D 226 2009
PRI Construction Materials Technologies(TST5878) CMI-048-02-OIC ASTM D 226 2009
PRI Construction Materials Technologies(TST5878) CMI-055-02-01 ASMT D 4533 2015
PRI Construction Materials Technologies(TST5878) CMI-056-02-01 ASMT D 4533 2015
'Determined to be equivalent to ASTM D 226(2009),Type 1 and II
PRODUCT DESCRIPTION
Tri-Built Synthetic 10 A mechanically attached, woven polypropylene underlayment (nominal weight = 1.74
Roof Underlayment Ib/100fe) used an alternative to ASTM D 226, Type I and Type 11 with a minimum tear
strength per ASTM D 4533 of 20 pounds. The underlayment is available in rolls 48-inch
wide by 250-ft long.
Tri-Built Synthetic 25 A mechanically attached, woven polypropylene undedayment (nominal weight = 2.05
Roof Underlayment tb/100fe) used an alternative to.ASTM D 226, Type 1 and Type 11 with a minimum tear
strength per ASTM D 4533 of 20 pounds.The underiayment is available in rolls 48-in6h
wide by 250-ft long.
Tri-Built Synthetic Plus A mechanically attached, woven polypropylene underlayment (nominal weight = 2.46
Roof Underlayment Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear
(i strength per ASTM D 4533 of 20 pounds. The undedayment is available in rolls 48-inch
C wide by 250-ft long.
Tri-Built Synthetic MAX A mechanically attached, woven polypropylene underlayment (nominal weight = 3.69
Roof Underlayment Ib/100fe) used an alternative to ASTM D 226, Type I and Type II with a minimum tear
strength per ASTM D 4533 of 20 pounds. The underlayment is.available in rolls 48-inch
wide by 250-ft long.
TBM16001.1 FL21553-R1 'Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC-of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
s
TRI-BUILT MATERIALS GROUP
CREEKSynthetic Underlayments
TECHNICAL SERVICES,LLC
APPLICATION INSTRUCTIONS
Deck Type: The roof deck shall be constructed of closely fitted,solid sheathing for new or existing
construction. Sheathing shall be installed in accordance with FBC requirements. New
construction.in the HVHZ shall be minimum 19/32-inch plywood. Roof decks shall
have no more than 1/8-inch,gap at abutting joints.
Attachment method Undedayment shall be attached in accordance with the FBC Table 1507.1.1 and
_ (non-HVHZ): manufacturer's installation instructions.
Attachment method Underlayment shall be installed with a minimum 4-inch head lap and minimum 6-inch
(HVHZ): end lap and be fastened as specified in FBC Section 1518.2.
Allowable roof coverings Mechanically attached roof systems,as prescribed in FBC Section 1507.1.1.
(Non-HVHZ):
Allowable roof coverings Underlayment.shall be used with mechanically attached asphalt shingles, metal roof
(HVHZ): panels and shingles,composite shingles and wood shingles and shakes
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift:resistance is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturers published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
5) Roof slope limitations shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave,starting at the eave,and lapped
in success courses installed up the deck in a manner that effectively sheds water from the deck.
7). The underlayment may be used as described in other current FBC product approval documents.
8) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the underlayment to the roof deck.
9) The underlayment shall not be installed over existing roof coverings.
10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
TBM16001.1 FL21553-R1 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer.shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEKTRI-BUILT MATERIALS GROUP
Synthetic Underlayments
TECHNICAL SERVICES,LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code,6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
1'����►11 nni���r .
E N %s 2018.02.21
'•� j 13:42:11
No 74021irZ;.
• 1 . = .. .. -051001
STATE OF
00'0'n'•'c ' �:~~ Zachary R. Priest, P.E.
�F�,Vn•�•O R 10. �,`�� Florida Registration No.74021
�l111�ONA— 't Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial Interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
TBM16001.1 FL21553-R1 'Page 3 of 3
This evaluation report_is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shah notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration far which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
Certificate of Authorization 29824
CREEK17520 Edinburgh Drive
Tampa,FL 33647
TECHNICAL. SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE 6T"EDITION(2017)
Manufacturer: TRI-BUILT Materials Group Issued February 21,2018.
9050 Louisiana Street
Merrillville,IN 46410
(800)516-1485
www.tdbuiltmaterlaisgroup.com
Quality Assurance: Intertek Testing Services(QUA1586)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1,1518.4
Properties: Physical properties
REFERENCES
Enti W Report No. Standard Year
Intertek Testing Services(TST1585) 102074565COQ=004 AC 188' 2012
Intertek Testing Services(TST1585) 102074565COQ-004A AC 188' 2012
Intertek Testing Services(TST1585) 102074565COQ-007 ASTM D 226 2009 .
Intertek Testing Services(CER1497) CCRR-1045 IBC,IRC 2012
PRI Construction Materials Technologies(TST5878) CMI-048-02-01A ASTM D 226 2009
PRI Construction Materials Technologies(TST5878) CMI-048-02-01B ASTM D 226 2009
PRI Construction Materials Technologies(TST5878) CMI-048-02-OIC ASTM D 226 2009
PRI Construction Materials Technologies(TST5878) CMI-055-02-01 ASMT D 4533 2015
PRI Construction Materials Technologies(TST5878) CMI-056-02-01 ASMT D 4533 2015
'Determined to be equivalent to ASTM D 226(2009),Type I and II
PRODUCT DESCRIPTION
Tri-Built Synthetic 10 A mechanically attached, woven polypropylene underlayment (nominal weight = 1.74
Roof Underlayment Ib/1001tz) used an aftemative to ASTM D 226, Type I and Type II with a minimum tear
strength per ASTM D 4533 of 20 pounds. The undedayment is available in rolls 48-inch
wide by 250-ft long.
Tri-Built Synthetic 25 A mechanically attached, woven polypropylene underlayment (nominal weight = 2.05
Roof Underlayment Ib/100f?) used an alternative to ASTM D 226, Type I and Type II with a minimum tear
strength per ASTM D 4533 of 20 pounds.The,underlayment is available in rolls 48-inch
wide by 250-ft long.
Tri-Built Synthetic Plus A mechanically attached, woven polypropylene undedayment (nominal weight = 2.46
Roof Underlayment Ib/100ftz) used an alternative to ASTM D 226,Type I and Type II with a minimum tear
strength per ASTM D 4533 of'20 pounds. The underlayment is available in rolls 48-inch
wide by 250-ft long.
Tri-Built Synthetic MAX A mechanically attached, woven polypropylene undedayment (nominal weight = 3.69
Roof Underlayment lb/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear
strength per ASTM D 4533 of 20 pounds. The underlayment is available in rolls 48-inch
wide by 250-ft long.
TBM16001.1 FL21553-R1 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not
specifically addressed herein.
TRI-BUILT MATERIALS GROUP
(CREEK Synthetic Underlayments
TECHNICAL SERVICES,LLC
APPLICATION INSTRUCTIONS
Deck Type: The roof deck shall be constructed of closely fitted,solid sheathing for new or existing
construction. Sheathing shall be installed in accordance with FBC requirements. New
construction in the HVHZ shall be minimum 19132-inch plywood. Roof decks shall
have no more than 1/8-inch gap at abutting joints.
Attachment method Underlayment shall be attached in accordance with the FBC Table 1507.1.1 and
(non-HVHZ): manufacturer's installation instructions.
Attachment method Undedayment shall be installed with a minimum 4-inch head lap and minimum 6-inch
(HVHZ): end lap and be fastened as specified in.FBC Section 1518.2.
Allowable roof coverings Mechanically attached roof systems as prescribed in FBC Section 1507.1.1.
(Non-HVHZ):
Allowable roof coverings Underlayment shall be used with mechanically attached asphalt shingles, metal roof
(HVHZ): panels and shingles,composite shingles and wood shingles and shakes
LIMITATIONS
' 1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to undedayment application.
5) Roof slope limitations shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave,and lapped
in success courses installed up the deck in a manner that effectively sheds water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the underlayment to the roof deck.-
9) The underlayment shall not be installed over existing roof coverings.
10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
TBM16001.1 FL21553-R1 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
TRI-BUILT MATERIALS GROUP
CREEKSynthetic Underlayments
TECHNICAL SERVICES,LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code,6t'Edition(2097)as evidenced in the referenced documents submitted by the named manufacturer.
PaY R. p 2018.02.21
No 74021 = 13:42:11
_ -05'00'
:P STATE OF
%�•c�••.'c P.' .4(,:� Zachary R. Priest,P.E.
E��`�, Florida Registraon No.
N ALOrganization Notl ANE9641021
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial Interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
TBM16001.1 FL21553-R1 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.