HomeMy WebLinkAboutDrawing a i
2
72" X 80"
1
36" X 80"
REPLACE DOORS IN 2 OPENINGS ONLY.
NEW DOORS TO BE IMPACT RESISTANT-
HURRICANE SHUTTERS NOT REQUIRED.
- F RECEIVED
AUG 15 2018
ST. Lucie County, Permitting
CY
�Pplf
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#). POS. NEG.
1 1 36 1 80 20.00 4 36.1 1 -39.3 FL22378.4 60.0 -60.0 SIDE GARAGE-LSMI
2 1 72 1,80 40.00 4 34.4 1 -37.6 FL16708.4 60.0 -60.0 LIVING ROOM-LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. (NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30%OF STRUCTURE'S VALUE.NOT A RENOVATED BUILDING.EXEMPT FROM 2017 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 11 FT 9 IN
DAVIS RESIDENCE
1201 ROYAL PALM BOULEVARD DOOR REPLACEMENT PLAN
FORT PIERCE, FLORIDA