HomeMy WebLinkAboutWind Load Calculation NewSouth WIN DOW SOLUTIONS 2526 Okeechobee Blvd,West Palm Beach,FL 33409•561-712-9000•CRC1330822 Property Information Building Information Owner: TOM&MARYANN SINAGRA Wind Zone: 170 MPH. Address: 357 SE VERADA AVE Exposure Category: C PORT ST LUCIE,FL 34983 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. ji� Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 73 49.50 7 35.5 -38.7 2 Int 35.50 24.50 7 37.8 -41.0 3 Int 71.50 79.50 7 34.4 -37.6 4 Int 58.50 42.50 7. 36.5 -39.7 5 Int 72 79.50 7 34.4 -37.6 6 Int 18 61.50 7 37.8 -41.0 7 Int 18 61.50 7 37.8 -41.0 8 Int 35.50 24.50 7 37.8 -41.0 9 Int 35.50 37 7 37.8 -41.0 RECEIVED AUG 17 2018 ST. Lucie County, Permitting Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.61h Edition(2017)Florida Building Code. Page 1 of 1