HomeMy WebLinkAboutWind Load Calculation NewSouth
WIN DOW SOLUTIONS
2526 Okeechobee Blvd,West Palm Beach,FL 33409•561-712-9000•CRC1330822
Property Information Building Information
Owner: TOM&MARYANN SINAGRA Wind Zone: 170 MPH.
Address: 357 SE VERADA AVE Exposure Category: C
PORT ST LUCIE,FL 34983 Minimum Building Dimension: 25 ft.
Mean Roof Height: 15 ft.
ji� Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 73 49.50 7 35.5 -38.7
2 Int 35.50 24.50 7 37.8 -41.0
3 Int 71.50 79.50 7 34.4 -37.6
4 Int 58.50 42.50 7. 36.5 -39.7
5 Int 72 79.50 7 34.4 -37.6
6 Int 18 61.50 7 37.8 -41.0
7 Int 18 61.50 7 37.8 -41.0
8 Int 35.50 24.50 7 37.8 -41.0
9 Int 35.50 37 7 37.8 -41.0
RECEIVED
AUG 17 2018
ST. Lucie County, Permitting
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.61h Edition(2017)Florida Building Code.
Page 1 of 1