Loading...
HomeMy WebLinkAboutProduct Approval (2) l 6/5/2018 Florida Building Code Online n ,II SCIS Home Log In User Reglstratlon Hot Topics Submit Surcharge Stats B Fads Publications FBC Staff BCIS Site Map Unks Search loft db94C A ^i Product Approval r USER:Public User Product Approval Menu>Product or Application Search>Apnlica[ion List>Application Detall � 7 FL# FL15378-R3 ' Application Type Revision Code Version 2017 Application Status Approved Comments Archlved Product Manufacturer NewSouth Window Solutions Address/Phone/Email 4901 oak fair blvd tampa,FL 33610 (513)284-0129 danochsteln@newsouthwindow.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Double Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer .Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By, Ryan 3. King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence " ELI R3 CO] (a)Certificate of Indeoendence.adf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2008 AAMA/WDMA/CSA101/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2005 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQvADgtHB572gvd WleHZ%2bkKh%2bFD794k9YGODmnpXiulzxBw%2blg%3d%3d 6/5/2018 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 10/12/2017 Date Validated 10/12/2017 Date Pending FBC Approval 10/18/2017 Date Approved 12/12/2017 Summar ry—of Products FL# --^ - Model,Number or Name - - Description - - - -- - ------- 15378.1 - -- a.DuraGard Double Hung Window DuraGard New Construction(Nail Fin)"Non-Impact"Vinyl Double Hung Window(X/X-configuration;Max Size 54 x 75) Limits of Use - - Installation Instructions Approved for use In HVHZ: No FL15378 R3 11 (g)Inst 15378.1.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Thltd Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15378.1 for Design Pressure Ratings,any FL15378 R3 AE (8) Eval 15378.1.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes ' particulars. 15378.2 rb.DuraGard Double Hung Window DuraGard Replacement"Non-Impact"Vinyl Double Hung - - -- - --A - Window(XIX-configuration;Max Size 54 x 75)- ----- Limits of Use Installation Instructions Approved for use In HVHZ:No FL15378 R3 II (pj Inst 15378.2.pdf Approved for use outside HVHZ:Yes Verifled By: Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15378.2 for Design Pressure Ratings,any FL15370 R3 AE (0) Eval 15378.2.or-d1 additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 15378.3 c.Sashlite Double Hung Window Sashlite New Construction(Nail Fin)"Non-Impact"Vinyl - ---� - Double Hung Window(X/X-configuration;Max Size 54 x 75) Limits of Use Installation Instructions Approved for use In HVHZ:No FLI5378 R3 11 (jj)In 15378.3.0f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15378.3 for Design Pressure Ratings,any FL15378 R3 AE (a)Eval 15378.3.pg additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15378.4 d.Sashlite Double Hung Window Sashilte Replacement"Non-Impact"Vinyl Double Hung Window(X/X-configuration; Max Size 54 x 75) Limits of Use Installation Instructions Approved for use in HVHZ:No EL15378 R3 lI (01nst 15378.4.pd Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15378.4 for Design Pressure Ratings,any -FL15378 R3 AE (p)-Evai 15378.4.odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 15378.5 e. DuraGard Double Hung Window DuraGard New Construction(Nail Fin)"Impact"Vinyl Double - - - Hung Window(X/X-configuration; Max Size 40 x 72) Limits of Use Installation Instructions Approved for use In HVHZ:No FL15378 R3 it (p,)_LnsL 15378.S.ppf Approved for use outside HVHZ:Yes Verified By: Lyndon F,Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15378.5 for Design Pressure Ratings,any FL15376 R3 AE (,0 Eval 152Z&L01 additional use limitations, installation Instructions and product Created by Independent Third Party:Yes particulars. 15378.6 f.DuraGard Double Hung Window DuraGard Replacement"Impact"Vinyl Double Hung Window (X/X-configuration;Max Size 40 x 72) l Limits of Use • Installation Instructions Approved for use In HVHZ:No FLIS378 R3 11 (p)Inst 15378.6.pdf Approved for use outside HVHZ:Yes Verified Byi Lyndon E Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure;N/A Evaluation Reports Other:See INST 15378.6 for Design Pressure Ratings,any httpsd/www.floridabuilding.org/pr/pr_app dtl.aspx7param--wGEVXQwtDgtH8572gvdWleHZ%2bkKh%2bFD794k9YGODmnpXiutzXBw%2blg%3d%3d 6/5/2018 Florida Building Code Online additional use limitations,Installation Instructions and product F115378 R3 AE (p) Eval 15378.6.Df particulars. Created by Independent Third Party:Yes Contact us::2601 Blair Stang Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer. Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mall address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address Hthey have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Departmentwith an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S. please dick hem. Product Approval Accepts: Credit Card Safe https://www.flaridabuilding.org/pr/pr_app_Otl.aspx?param=wGEVXQwtDgtHB572gvd W leHZa/o2bkKha/o2bFD794k9YGODmnpXiut2XBwa/a2blga/a3da/a3d zNewsouth = t WINDOWS01UTIONS =�� ' :,;.�. 4901 Oak Ea t31vd.,Tampa,FL 33810MAX OVIRAU fR/1MEydID111 � � � E� bcl S c� o DuraGard a Double Hung Window "IMPACT X g N GENERAL NOM 1. This product has been evab/ated and is in compliance with the 6th Edition(Za17(Rondo 0 Building Code(FOCI structural requirements excluding the"High Velocity Hurricane Zone' = 2 Product anchors shah be as feted and spaced as shown on detalls.Anchor embedment v to base material stag be beyond wag dressing cr stucco. x 3. When used in areas requNng wind frame debris protection this product,complies with FOC Sections 1609.12&R3012.12 and does notremAre an Impact resistant covering.'Thts / En product meets mWe level V and excludes Wind Zone 4 as defined In ASTM El 996 and Z Cn FBC Sections 1609.122&8301alal. Ll i 9 4. For 2x stud framing construction.anchoring of these nmKs shag be the same as that sham for 2x buck masonry construction. 5. Site conditians ftat deviate from the details of this drawing require further z engtneedng cno"by a kensed eng&near or registered amldtect. TASTE OF COMEMS At" MAX a rll>ul►wa o SHEET! DESCRTPRON ROME 0.Ca, 'M MM, DMOUM 1 Typical elevations,design pressures 8general notes IOC. NEG ase 6117115 : 2 Vertical a horizontal cross sectionsx 7aAr s�1T x tear Gt X50.0 -50.0 ' N.T.S. 's 3 Vertical&horizontal cross sections OM W. JK a 4 Buck&trams anchoring CML si LFS 5 Components m. ; E 6 Mofmaterials and gt&g detaft FL-15378.6 ' o sir 1 ar 6 d i D ppm _ t.JAM MVORCB0�UC11r BH{ WLOCAND �y ATDfPKWWSASH TRTLATOIONEACH JAM6 •, 'a a i ( �# Cg ds ANDUMRMWrrHCNEOBtt1.1/4•Rt SMS. E 1 1 TFROMSAM ED roll C i X ao 33 4 12 Fxt ` 1-1l4'MRL E �sff NOtE l � i Kam 1 EML�a if 14 31 iZ ® G1 29 G1 f - 30 12 as ,r z 01 31 13 . . ame1715 E � FJfiF�R R � .•• N.T.S. @ an e, JK 3E 1 MXWWAL CROSS Sm=N 1 ar■■.,r,tfs rRt Ot RkKk M. l..y ft w t. FL-15376.6 r alar ar a . S -IF A-r A=$ a'Qcrsi-v ° ■■rro Nk�w�Q1 mom [S se Mms—=5 m=n. C L 3 ■ xr w�■■ _ GIA I 9 moo D � D � i L ,. Lt 9 loam aoQeuo l9 L9 1 L Q R '9L It � 6 w Lis A• Le LL IF •O.' nwwasn-2xniM � wv r .� fL rHDW"OH]tvlmNmwol=3xuv IRM33S awv BION i MCtmmiVYwSouth MwnPUNN MA-MOldSRaAu¢ApPev&M-1l11100OWN!MMOIC-DnwYipgRr15771(2o17lVtds3/1d yai !� N Y lilt All All Ind ore 3 t_ �*` No.43100 s* gg Oalobrl?,Ll017: r DOUBLE HUNG women vl z0o rr�nl eass�s�� C PARI OR ASSOAGM, [M1tDIN0 0110L�TAIAa, 11e. (rl N LIP6OE E0. 1 #W X 81JCL(&FRAME /I/1 '•O:flog.230.YaYMa.TL 77011 q A&10W Ph IbA 013AN.0107 Rmgm FWE CJS NA 0613 aol•w.w.auu.o�ww oww�rw.rta nye. WXP'bV#M south wNae.,P60MrKlI+v+-Nail.v gduCtMpra.b�q,asne aoui+�HW�c-Oradq�4lSlita017�1a.sssneie¢s6 . zrr— OIT .ase—•� o oar } aw Im U. -T asemww tt4i r TT N xos , aar LAW eFil aw 0 atlBatE WJW ti CM P. y;, ''�rrrrrunrati`�t PNR aR1" AirMao"castaTNnite,Na. a jn a t r- uPatte ro am } atc PA liar saw.vwr+m„ FL 3=5 Phan.mw 3sa#44ssn FM art. No.9613 R1OM�bVko SoM Wh:Qoe fE19AAr61M-lipidr p1oAaRJiO -1lAf•Dw1i•Hu�t-OlwNpdiL•1S3rf Ro171W�a+4� • (p lGj. �4r� �NO.00 V PN�r.11J�;•n m 000p>4"M i! D a r f� q ' a,,``IIIIIIIIfgJ�,I Oobw III 9f7 i 7 gg PFAMGf MGPWU OP�i� �• i y v 2" @1,111DIMoVOW oorauuaMia, a u tN Td lA f KOF D�TAIiS 'Man ►hon•Mw 813AB t4s FL awe . AKNOL GLOWiWE 6A ML 867J 1019 M.M.llwwM c=mmfAIrrII h+0. R R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Vahico,FL 33595 Phone 813.659.9197. Florida Board of Professional Engineers Certificale of Amhoriration No.9813 / 2017 Product Sub Category Manufacturer Product Name Category NewSouth Window Solutions DuraGard 4901 Oak Fair Blvd Double Hung Window Windows Double Hung Tampa,FL 33610 (813)6266000 "Impact" Scope: Product Evaluation report issued by R W Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for NewSouth Window Solutions,based on Rule Chapter No.61G20-3,Method 1 D of the State of Florida Product Approval, Dept.of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will agquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Umitations: 1. This product has been evaluated and is incompliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wail dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering.This product meets missile level"D"and excludes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.1.2&R301.2.1.2. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-15378.6 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-15378.6 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Waned by ATI 98115.04-501-44 AAMAIWDMA/CSA 101/1.S.21A440-08 Architectural Testing,Inc. Lynn George ATI 98115.03-501-44 ASTM E 1886-05/E 1996-05 Architectural Testing,Inc. Lynn George 2. Miami-Dade NOA Material 17-0712.04 Sallex PVB Interlayers(Eastman Chemical Co.) 3. Drawinci No. Prepared by QrDy,o'r, Signed&Sealed by No.FL-15378.6 RW Building Consultants,Inc.(CA#9813) Lyndon F,Schmidt,P.E. A 4. Calculations Prepared by �`,%� V. .........� ,0 E Pd S� '� °aigned&Sealed by Anchoring RW Building Consultants,Ina(CA#9813) No 43409 ; *-In F.Schmidt,P.E. 5. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute,certifying that NewSouth Window Solutions is STATE OF ' manufacturing products within a quality assurance program that complies :,®s A% P with ISO/IEC 17020 and Guide 53. ��ss�C�'Sti' ®�`�'�����, Lyndon F.Schmidt,P.E. FL PE No.43409 °rrao toil%% 10/122017 Sheet t of 1