HomeMy WebLinkAboutBuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 8/15118 Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential x
PERMIT APPLICATION FOR: Plumbing 0
ROPOSED IMPROVEM
Address: 101 SE NARANJA AVE PORT ST LUCIE, FL 34983
Legal Description: RIVER PARK
Property Tax ID #: 3419-540-0156-000-2 Lot No. 19
Site Plan Name: Block No. 47
Project Name: ORR
Setbacks Front Back: Right Side: Left Side:
ETAILED DESCRIPTION OF WO,
REPLACING 40 GALLON NATURAL GAS WATER HEATER WITH A NAVIEN NPE-210S NATURAL
GAS TANKLESS WATER HEATER
17
Additional work to e erorme under tispermit—c ec a appy:
CJHVAC � Gas Tank 0Gas Piping _ Shutters ❑ Windows/Doors
11 Electric 0 Plumbing Sprinklers Generator Roof Roof pitch
Total Sq. Ft of Construction: Scn of First Floor:
Cost of Construction: $ 2450.00 Utilities: Sewer Septic Building Height:
OWNER/LESSE llffW CONT R,,; ..
Name KATHERINE ORR Name: RICHARD BASSOFF
Address: 1709 PASEO AVE Company: ADMIRAL PLUMBING SERVICES, LLC
City: FORT PIERCE State:FL Address: 2895 JUPITER PARK DR #700
Zip Code: 34982 Fax: City: JUPITER State: FL
Phone No. 772-971-1092 Zip Code: 33458 Fax: 561-744-7101
E-Mail: Phone No. 561-746-1180
Fill in fee simple Title Holder on next page ( if different E-Mail: PERMITTING@THEADMIFZALPLUMBER.COM
from the Owner listed above) State or County License: CFC 1426115
If value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
DESIGNER/ENGINEER: _ Not Applicable
MORTGAGE COMPANY: _ Not Applicable
Name:
Name:
Address:
Address:
City: State:
City: State:
Zip: Phone
Zip: Phone:
FEE SIMPLE TITLE HOLDER: _ Not Applicable
BONDING COMPANY: _Not Applicable
Name:
Name:
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing, consult with lender or an attorney before
commencing work or recordingyour Notige of Commencement.
Signatu f wn / Lessee/Contr for A nt for Owner
Signature of Contractor/License Hol de
STATE OF FLORIDA
STATE OF FLORIDA
COUNTY OFPA�M BBAcH
COUNTY OFPALM BEACH
The forgoing instrument was acknowledge me
this 15TH day of AUGUST . 2O1 by
The forgoing instrument was acknowledgedbefore me
Jefore
this 15TH day of AUGUST 26by
4�
RICHARD BASSOFF
RICHARD BASSOFF
Name of person making statement
Name of person making statement
Personally Known x OR Produced Identification
Personally Known x OR Produced Identification
Type of Identification
Type of Identification
Produced
Produced
ture of Notary Publ' t o n
Notaryuubec State of Fkaltla
;M9/1MISSion• S RV19 kCoate
No. My abnt3G032847
orw Faptrea 71/13/2020
(Signa re of Not
p e f•ry Public State of FierWa
; t OmI)
Co mission N0. y can Clark
':}a Comgra m11131202issibri 0 032847
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
RECEIVED
DATE
COMPLETED
Rev. 8/2/17
�- eCn i !: of �ietn r i.
'...GS'.0 cr,n,.A R �
F tr 4n�.' eF�-' I ��:1
}) �>r1 ,
9, n r.J�..., r .j r'yb �Jir T
CCC. �y���/�su:� � - Nin
Michelle Franklin, CFA-- Saint Lucie County Property Appraiser -- All rights reserved.
Property Identification
Site Address:
Parcel ID:
Account #:
Map ID:
Use Type:
Zoning:
City/County:
Ownership
Katherine T Om
Christopher R O'Neill
1709 Paseo Ave
Fort Pierce, FL 34982
Legal Description
RIVER PARK -UNIT 5 ELK 47 LOT 19 (MAP 34/28N) (OR 2005-1925)
Current Values
Just/Market Value: $85,700
Assessed Value: $45,679
Exemptions: S0
Taxable Value: $45,679
Taxes for this parcel: SLC Tax Collector's Office 10
Download TRIM for this parcel: Download PDF 12
101 S NARANJA AVE
3419-540-0156-000-2
42833
34/28N
0100
RS -4
Saint Lucie County
Total Areas
Finished/Under Air (SF): 1.225
Gross Area (SF): 1,765
Land Size (acres): 0.3
Land Sire (SF): 13,145
This infomiatiun is believed to be correct at this time but it is subject to change and is not warranted.
C9 Copyright 2018 Saint Lucie County Property Appraiser. All rights reserved.
l/I. 6d.fbd4No£gMbuuO-l00 o1o4d APS gLblbOgROOeq-OSLq-£eZb-oZ90-09ZOo9oP�lZ%SayoellV=aweuZgor/4oel1V/woovelgaNAlas o6//:sd114
xdi S3lds -
7(t1L?rj-1,43.
� a7�ll�nra�u�lrunci�sl� na� �'�'1tL
f SVu1X3 _ I Illfll {srp
iOlA.3' 3S _ nn x/
r+wj 4la:y uj _ et0l}_le/till' Wi slp 2' ubl woxA:I Guar -3 a41 aI Pa1<u tq.::gl
% !/�; ,dsll(+wd phis uo ulgwnlA pallelaul
6p9dadwl ,o Lavoxq pate o::olop AUe o1 xogel {o 6nsv a se sosul:oxd col
sodld uaAwu )o sweip ouGbar) 01 o -p abawxp as;enwnl dlgsy lou gHO'!wpp anoga oe waysAd 6ulqumjd eqj oI sa6auiep xol swlela Aue )ol apep IOU s IegwpV
'SNtVN0039DO10 N0331NtlNtlnOON- 'SHnOH S634PSi1S lVP1l1GN ONIEnQ M Hd H9A0HHlAV0N0W SAVO OC N130NO Hoo anwvwm 33mn
Xanleu6lg
�aHaaxa4t+nay/uana:W_._.—____. _.SDue mo4l-^M a4lxol.__- __.3lol u!pp paqu3sep anoge a4l ayeus 6u,gwnld lexlwPV ane4 of aa)6e Aga)a41�
'T g am1au61S
qwa a4i aloldwoo of sage; 11 awq ay to ssaPS591 D -Slo aopd ay) lol moos pagwsap 4J"aW alaldwoo 6wqumld lellWPV ane4 of aa)6e Aga)ay{pli
j
j __ :suapnpuarmonoag
.: Ittawedl6y dB:Nd j -.�
__. ...__ _... _- _.....-
IS 6o 9 6egle! `l
IG NO (1
V .. ._ .._. sutwfl fi
s
`` V/
77epOlil
a�
6'/VV,7 X71 Iv / �r + 7 ' f
- 4
88C{ -98Z CILLI Gall -901 11951yMi
'1
1 Wr ill 'sal�inaasr uicm�r�urr;��
:af�.tn:�s:aio- .. :i.1 ./ %Ir tlf`f MwMRlFlrr
(b9Z£xRbb7,) qor Rl 07/90R
ORR
101 SE NARANJA AVE
PORT ST LUCIE, FL 34983
EXHAUSI
VENT
NAVIEN NPE-210S
TANKLESS
180,000 BTU
LINE
AIR INTAKE
VENT
OUTDOOR UTILITY ROOM
REMOVING EXISTING 40 GALLON NATURAL GAS HEATER & REPLACING IT WITH A NATURAL GAS
NPE-210S TANKLESS HEATER IN THE OUTDOOR UTILITY ROOM. THERE ARE NO OTHER APPLIANCES IN
THE HOME THAT USE GAS.
ADMIRAL PLUMBING SERVICES, LLC
2895 JUPITER PARK DR #700
JUPITER, FL 33458
CFC1426115
mNavieN
Premium Condensing
Tankless Gas Water Heater
• Certified design according to ANSI Z21.10.3/CSA 4.3-2011
standards for both indoor or outdoor installations (with
optional Outdoor Vent Kit)
• Compatible with 1/2" gas pipe up to a length of 24 ft -
('see Entail tion Manual for additional information)
• Compatible with 2" PVC vent up to 60 ftei and 150 M•
using 3" PVC vent t• vdab no elbaws)
• Gas Input Ranges
NPE-180 -150,000 to 15,000 BTUh
NPE-210 -180,000 to 19,900 BTUh
NPE-240 - 199,900 to 19,900 BTUh
• Hot Water Flow Rate Capacity
NPE-180 - 8.4 GPM
NPE-210 - 10.1 GPM
NPE-240 -11.2 GPM
• Dual Primaryand Secondary Stainless Steel Heat
Exchangers for optimum efficiency and durability
• Built-in Control Panel - allows adjustment of temperatmro
settings and displays the operating status and error codes
• nFiaWlTechnology -"A" models come included with
built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide
maximum comfort
• INTELLIGENT Preheating - recognizes hot water usage patterns
to intelligently provide hot water when needed (optional far 's` models)
• Temperature Options - available temperature settings for
Residential applications range from 98"F up to 140"F with high
temperature Commercial mode capable of up to 1820F
• Ready -Link Multi -System - up to 16 units can be cascaded
together for increased hot water production
• Reduced pressure loss for maximum hot water output
• Ease of Maintenance and Service - allows for quick removal and
simple repairs to waterway components such as the pump, water
adjustment valve, and 2 -way valve
NPE Series Tankless Water Heaters
• Freeze Protection - maintains normal operation during freezing
ambient temperatures down to -S°F (standard on all models)
• Energy Factor Ratings
NPE-A Series - 0.97 (NG/LPG) NPE-S Series - 0.99 (NG/LPG)
• Compatible with Natural Gas (NG) and Propane (LPG)...
P" regalres installation of included Field conversion Kir by a qualified gas servimr)
• Approved for Installations on Mobile/Manufactured Homes
• Certified by CSA, NSF 5, AHRL AB1953 CA Low Lead, SCAQMD
(Rule 1146.2 Type 1 - Complies with 14 ng/j or 20 ppm NOx @ 3% 02)
• 15 -Year Heat Exchanger and 5 -Year Parts Warranty (Residential)
8 -Year Heat Exchanger and 3 -Year Parts Warranty (Commercial)'•••
r• see Navien Umited Warranty)
Optional accessories are available (see below)
Specification Sheet
n1-9
Sleek Design -Compatible with
2"PVC Vent and 1/2" Gas Pipe
Po.eraN/oFF
Built -In Control Panel
with Diagnostics
Indoor and Outdoor
mwe cap ' Venting Options
[ouWng �
2 Rpe—
a moa,
vea,
Non -Direct Vent pndwid Non -Direct Vent) Outdoor)
�/snj�ny
filliralm® (are'ZJ'a® e.
job Name:
Location:
Engineer:
Wholesaler:
Contractor:
Model No.:
Submitted to:
Remota Controller Cand•neGN•utralivr fiaady-Link 3" Vent Termination Caps
NK -2000 Plumb Easy Valve set 13/4'1 (G%%%O01 322 -Single Unit) Communication Cable Outdoorvem Kit External pump Wire and WallFnngos
130009752A) MA0900002A-Lead Free) (r•I(E%001324. Up m b Units) gCIW11391 (30010604A) 130011fi12A) IBH253500bA)
VSK00001325 UPW 16 UNta)
smavieN
Premium Condensing
Tankless Gas Water Heater
Dimensions
NPE Series Tankless Water Heaters
Specification Sheet
Specifications
Item
NPE-1 BOA PE 180S NPE-210A I NPE-2105 NPE-240A I NPE-2405
Heat Capacity
Nmural Gas
15,000150,000 BTU/H 19,900180,000 BTU/H 19,900-199,900 BTU/H
(input)
Propane Gas
15,000-150,000 BTU/H 19,900-180,000BTU/H 19,900-199,900 BTU/H
35'F(19QTemp Rise
84 GPM (32 Um) 10.1 GPM (38 Um) 112 GPM (42 Um)
Flow Rate IDHW)
451(2YQ Temp Rise
6.5 GPM (25 Um) 7.8 GPM (30 Um) 8.7 GPM (33 Um)
77"F143°QTemp Rise
3.BGPM 114 Um) 3.9GPM IIS VmI 4.4 GPM U7 Um14.6 GPMIIIUmI 4.9GPM p9 Vm) 5.1 GPM (19 Vm)
Dimensions
17.3'(W) x 27.4"(H) x 13.2'(D)
Weight
75lbs (34kg) 67 Has (30 kg) 8216s (37 kg) 7516, (34 kg) 82 His (37 kg) 75 lbs (34 kg))
Installation Type
Indoor or Outdoor Wall -Hung
Venursg Type
Forced Draft Direct Vent
Ignition
Electronic Ignition
Water Pressure
15.150PSI
Natural Gas Supply Pressure lhom source)
3.5'-10.5"WC
Propane Gas Supply Pressure(from source)
8.0"-13.0"WC
Natural Gas Manifold Pressure (min to max)
-0.04'WCto-0.84'WC
-0.04"WC to-0.36"WC
0.04'WC to-0.58"WC
Propane Gas Manifold Pressure (min to max)
-0.03' WC to-0.50"WC
-0.02"WC to-0.66"WC
-0.02"WCto-0.78"WC
Minimum Flow Rate
0GPM to U.)for"A' models / 0.5 GPM (1.9 Urn) for'S'models
Cold Watednlet
3/4'NPT
Connection Sizes
Hot Water Outlet
3/4"NPT
Recirculation Inlet
3/4"NPT (on"A"models only)
Gas Inlet
3/4" NPT
Main Supply
120V AC, fiOHz
Power Supply
Maximum Power
Consumption
20OW(up to 2 amperes), 35OW (up to 4 amperes) with external pump connected
Casing
Cold Rolled Carbon Steel
Materials
Heat Exchangers
Primary Heat Exchanger: Stainlcs55tecl
Secondary Heat Exchanger: Stainless Steel
Exhaust
2" or 3" PVC, CPUC, Polypropylene
2" or 3" Special Gas Vent Type BH (Class 11, A/B/Q
Venting
Intake
2' or 3" PVC, CPVC, Polypropylene
2' or 3' Special Gas VentType BH (Class Il, A/8/Q
Vent Clearances
Orto Combustibles
Safety Devices
Flame Rod,APS, Ignition Operation Detector, Water Temperature High Limit Switch, Exhaust Temperature High Limit
Sensor, Power Surge Fuse
Gas-fired, tankless, condensing, wall -moulted water heater(s) shall be direct vent NPESeries models as manufactured by Navien, Inc. and are certified by CSA Group to the
latest edition of ANSI standard Z21.10.3/CSA4.3. Water heater(s) shall have a 15 -year limited Heat Exchanger warranty and 5 -year limited Parts warranty (8 year Heat
Exchanger and 3 yen -Parts for Commercial use) per Navien Limited Warranty. Unit(s) shall be designed to burn natural gas and can he for use with propane when a Field
Conversion Kit is installed. Water heater(s) shall have a nominal flow rate capacity of GPM/GPllat_°F rise with rated input of 8TUi Water
heater(s) shall be vented with 2"PVC/CPVCvent pipe at a distance not to exceed 60' (or equivalent) with each elbow equal to 8'ofpipe length or 3"PVC/CPVC vent pipe at
distance of 150' (or equivalent) with each elbow equal to 5' of pipe length. Waterhealer(s) is rated for 150 PSI working waterpressure and 300 PSI test pressure. Gassupply
pressure shall be 3.5" to 10.5"111C fornalural gas and 8.0" to 13.0' WC forpropane. Units) shall have a steel case, dual stainless steel heat exchangers, eco premixed burner,
negative pressure gas valve, dual ventun, 3/4"inletgas connection, 3/4"brass inlet/outlet water connections, water holding capacity ofl.0gallon for the NPE-180A model
(0.7,gallons for NPE-160S model), 1.2gallons for the NPE-110A/NPE-240A models (0.7 and 0.99allons for NPE-2305 and NPE-2405 models respectively), and a condensate
collector. The NPE-180A model weighs 751bs (NPE-1805 weighs 67Ibe), and the NPE-210A/NPE-240A models weigh 82lbs (NPE-2105 and NPE-2405 weigh 7516,). Unit(s)
thull include featuressuch as an adjustmentfor installations at high elevation, temperature lockout and temperature options from 98-120°F in 1 °Fintervals and 125-140°F
in 5°F intervals. The unit(,) shall include additional temperature optians of150-180°Fin 10°Fintervals, and 182°17for high temperature conrnercial applications. All NPE
A"models shall include an internal circulation pump and QSgallon buffer tank. The water heater(s) shall be controlled by at, internal circuit board that monitors the inlet
and outlet temperatures with installed thermistors, sensing and controlling flow rate to set point temperature with air fuel ratio controls in order to maintain thermal
combustion efficiency. Unit(s)shall include safetyfeatures such as flame sensor system, high limit sensors, overheat prevention device, freeze protection mode, and fan motor
rotation detector Multi -system (cascade) applications that require 2 to 16 units shall be installed by connecting the units using cable -only connections (Ready -Link). The
seater heaters) exceeds the energy efficiency requirements cfASHRAE 90.1-2013 and is listed bySCAQMD rule 1146.2 (Type 1) for Low NOx that complies with 14 ng/f or 20
ppm NOS requirements @ 3% 02.
'Navien reserves the right to change specifications, at any Littre without prior notice
Navien, Inc. 20 Goodyear, Irvine, CA 92618 Ph: (949)420-0420 Fax: (949)420-0430 www.Navien.com Rev. 12/14