Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 3 y SCIS Home ; Log In User Registration Hot Topics Ligation ge i Stats&Facts Publications € Contact U F�;1da *jf'Tj ;j',Product Approval USER: Public User d tDv _ Product Approval Menu > Product or Application Search > >Application Detail h FL # CF:L=14911-R10 Application Type Revision Code Version 2017 Application Status Approved Comments public comment. 05/18/18 Archived 0 Product Manufacturer Silver Line Building Products Corp. Address/Phone/Email One Silverline Drive North Brunswick, NJ 08902 (651) 264-4178 Nicholas.Kopp@andersencorp.com Authorized Signature Nicholas Kopp Nicholas.Kopp@andersencorp.com Technical Representative Jon Berrian Address/Phone/Email One Silverline Drive North Brunswick, NJ 08902 (732) 435-1000 jonberrian@slbp.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered P Professional Engineer 0 Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed ti e Hermes F. Norero, P.E. Evaluation Report Florida License PE-73778 Quality Assurance Entity Window and Door Manufacturers Association- Quality Assurance Contract Expiration Date 08/03/2021 Validated By Locke Bowden P.E. R Validation Checklist- Hardcopy Received Certificate of Independence FL14911 R10 COI COI Silverline SS 2017-01 Referenced Standard and Year(of Standard) Standard AAMA/W D MA/CSA/101/I.S.2/A440 https://www.floridabuilding.org/pr/pr_app_dt .aspx?param=wGE... 8/15/2018 Florida Building Code Online Page 2 of 3 AAMA/W DMA/CSA/101/I.S.2/A440 ASTM E1886 ASTM E1996 ASTM E1996 ASTM E1996 ASTM E330 TAS 201 TAS 202 TAS 203 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/20/2018 Date Validated 04/20/2018 Date Pending FBC Approval 05/01/2018 Date Approved 06/12/2018 Summary of Products FL# Model, Number or Name Description 14911.1 VI Series/50 Series (2000) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R10 II SWD017 SS 20: Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P. Impact Resistant: No Created by Independent Third Pai Design Pressure: N/A Evaluation Reports Other: See Installation Instructions and Product Evaluation FL14911 R10 AE PER5140 SS 21 Report for allowable design pressures, sizes, installation Created by Independent Third Pai requirements and limits of use. 14911.2 V1 Series/50 Series (2111) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R10 II SWD018 SS 20: Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P. Impact Resistant: No Created by Independent Third Pai Design Pressure: N/A Evaluation Reports Other: See Installation Instructions and Product Evaluation FL14911 R10 AE PER5141 SS 21 Report for allowable design pressures, sizes, installation Created by Independent Third Pai requirements and limits of use.. 14911.3 V1 Series/50 Series (2200/2300) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R10 II SWD019 SS 20: Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P. Impact Resistant: No Created by Independent Third Pai Design Pressure: N/A Evaluation Reports Other: See Installation Instructions and Product E aluation FL14911 R10 AE PER5142 SS 21 Report for allowable design pressures, sizes, installa ion Created by Independent Third Pai requirements and limits of use. 14911.4 VI Series/70 Series (212 ) Single-Hung Window https://www.floridabuilding.org/pr/pr_app_dt .aspx?param=wGE... 8/15/2018 { Florida Building Code Online Page 3 of 3 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL14911 R10 II SWD049 SS 20: Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P. Impact Resistant: No Created by Independent Third Pai Design Pressure: N/A Evaluation Reports Other:.See Installation Instructions and Product Evaluation FL14911 R10 AE PER5485 SS 21 Report for allowable design pressures, sizes, installation Created by Independent Third Pai requirements and limits of use. 14911.5 !V1 Series/70 Series (212 ) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL14911 R10 II SWD050 SS 20: Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P. Impact Resistant: Yes 'Created by Independent Third Pai Design Pressure: N/A Evaluation Reports Other: See Installation Instructions and Product Evaluation FL14911 R10 AE PER5486 SS 21 Report for allowable design pressures, sizes, installation Created by Independent Third Pai requirements and limits of use. 14911.6 V3 Series/70 Series (2907/4907) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 RIO II SWD020 SS 20: Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P. Impact Resistant: No Created by Independent Third Pai Design Pressure: N/A Evaluation Reports Other:'See Installation Instructions and Product Evaluation FL14911 R10 AE PER5143 SS 21 Report for allowable design pressures, sizes, installation Created by Independent Third Pai requirements and limits of use. Back Next Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement:: Accessibi Under Florida law,email addresses are public records. If yo do not want your e-mail address released in response to electronic mail to this entity. Instead,contact the office by r hone or by traditional mail. If you have any questions, pie to Section 455.275(1),Florida Statutes,effective October 1,2012, licensees licensed under Chapter 455, F.S. must p address if they have one.The emails provided may be used for official communication with the licensee. However emz do not wish to supply a personal address, please provide th 2 Department with an email address which can be made a, you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card Safe https://www.florid-alu-uilding.orii/Dr/pr app_dt .aspx?param=wGE... 8/15/2018 r SILVER LINE WINDOWS AND DOORS SOVe ; V1 SERIES170 SERIES GENERAL NOTES: SINGLE—HUNG WINDOWS (2907/4907) Nom.= 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT EDITION Z3 FLORIDA BUILDING CODE(FBC),EXCLUDING HVHZAND HAS BEENEVALUATED ACCORDING TOTHE FOLLOWING: • AAMA/WDMA/LW 101/14.2/A440.11 W O R k 2.ADEQUACYOFTHEEXISTINGSTRLICTURAL _ O3.q urEB DONCRETE/MASONRY,2X FRAMING,AND METAL FRAMING 2n al t I AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF tu I WITHSTANDING AND TRANSFERRING APPLIED PRODUCT iz N p ONS LOADS TO THE FOUNDATION IS TH E RESPONSIBILITY OFTHE TABLE OF CONTENTS N Lu 2 ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF p INSTALLATION. SHEET REVISION SHEET DESCRIPTION O 1 - GENERAL NOTES&GLAZING DETAILS ,fn W 3.SXAND2XBU0KS IWHENUSED)SHALLBEDESIGNEDAND l4 W ANCHOREDTOPROPERLVTRANSFERALL LOADS TOTNE 2 - ELEVATIONS i STRUCTURE.BUCK DESIGN AND INSTALLATION IS THE 3 - ANCHORJAYOUTS REMARKS BY DATE 3 RESPONSIBILITY OF THE ENGINEER ORAF..Cr OF RECORD. 3 _ FOR THE PROJECT OF INSTALLATION. 4 VERTICALSECNONS 6TH FBC EDITION FM 10/17 4.THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC 5 - HORILONTALSECTIONS ANDMAY NOTREFLECTACTUALCONDMONSPORASPEQFIC 6 - ANCHOR DETAIL SCHEDULE d SITE.IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE -_ FROM THE REQUIREMENTS DETAILED HEREIN,A LICENSED ' ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECINC Nmc � DOCUMENTS FOR USE WITH THIS DOCUMENT IN NON.HVHZ AREAS.IN NVHZ AREAS,ONE TIME PRODUCTAPPROVALTO BE OBTAINED FROM MIAMI-DADE FOR DRAW. rwm�rsroms Damon. S.APP ROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED ON �M IBnudbypEfa orore^P.E. St 1 THIS PRODUCE IN AREAS REQUIRING IMPACT RESISTANCE. - 11P 6.WINDOW FRAME MATERIAU PVC 4364"O.A. � •��C .'F,p0'�L 4 INSULATED GLASS y 7.GLASS MEETS THE REQUIREMENTS GLAZING 0FASTM AILS. 00 GLASS CHARTS.SEE SHEEf4FOR GLAZING DETAliS. _ EXTERIOR INTERIOR �O ( P;'•�u�� I DESIGN PRESSURETABLE _11"1 ZONAL" of SIZE CONFIGURATION DESIGN PRESSURE MISSILE IMPACT RATING / STEELSPACER I lHr ll% .40.0'X 69.0' 0/1(' +35/-35 PSF NON-IMPACT Ty pPm 44.0"X 60.0" O/X +35/-35 PSF NON-IMPAR I I •D 148.0'X84.0° O/X +20/-20 PSF NON-IMPACTSILICONE FLq: s 80.0•X 84.0' O/X-0/X +15/-15 PSF NON-IMPAR F L14911 ,64.0"X68.0' OM-0/X +3S/-3S PSF NON-IMPAR oaTE: 09.21.17 .80.0'X82.0' O/X-0/X +20/-20 PSF NON-IMPACT 1/2"MIN.GLASS _� 90.0'X74.0° OM-0/I( +IS/-15 PSF NON-IMPACT BITE DWGCL DH HFN GLAZING DETAIL ;715'X60.0• 0/-0/X H5/-35 PSF :NON-IMPAR SCALE: NTS 107.0"X62.0' O/I( -0/X +35/-35 PSF NONAMPAR SWD020 f ;307.0"X74.0" O/X-0/X-0/X +20%20 PSF NONIMPACT GLAZINGNOTE: SHEET: GLASS THICKNESS AND TYPE SHALL �I COMPLY WITH ASTM E-1300 GLASS ,III CHARTS REQUIREMENT OF 6