Loading...
HomeMy WebLinkAboutNotice of Acceptance I I I I i MEMO I etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford,CT 06478 (203) 262-9245 ' ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION YSoprema, Inc. Evaluation Report 518010.06.09-1112 1640 rue Haggerty FL2569-1114 Drummondville,Quebec J2C 5P8 Canada Date of Issuance:06/15/2009 (819)478-2400 Revision 12:02/12/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applic ble rules and regulations governing the use of construction materials in the State of Florida. The documentation su mitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance wi h the 6th Edition (2017) Florida Building Code sections'noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code hat relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility locati)n(s). NEMOIetc. requires a complete review of this Evaluation Report relative to updated Code requirements with ea h Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the wo ds "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report sha,l be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M.Nieminen,P.E. %fir,c, ..r: The facsimile seal appearing was authorized by Robert %FS�;� •" Nieminen,P.E.on 02/12/2018.This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 ,,, .. electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC,LLC does not have,'nor does it intend to acquire or will it acqu re,a financial interest in any company manufacturing or distributing products it evaluates. 2. MEMO ETC,LLC is not owned,operated or controlled by any company manu acturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest it any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOIetc. nor Robert Niemin n, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/w s used for permitting or design guidance unless retained specifically for that purpose. 1 ' i I OMEMO etc. j ROOFING COMPONENT EVALUATION: SCOPE:1. Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by oprema, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Cod through testing in accordance with the following Standards. Compliance is subject to the Installation Requirem nts and Limitations / Conditions of Use set forth herein. STANDARDS:2. Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004 ERD(TST6049) Physical Properties 2757.02.05 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) Wind Resistance 2779.11.05-111 04/18/2007 ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007 ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-R1 04/01/2010 ERD(TST6049) ASTM D1970 TAS 110 531370.03.10-1-R1 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesio i 511150.05.10-R1 09/09/2010 ERD(TST6049) Physical Properties/Tensile Adhesio i S11150.05.09-R2 10/05/2010 ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011 ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesio i 543530.02.14-1 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesio 1 SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015 ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015 ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017 PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL,LLC(QUA9625) Quality Control Service Confirmation Exp.07/18/2020 4. PRODUCT 4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). 4.2 Lastobond Shield is a self-adhering, woven polyethylene su aced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch;meets ASTM D1970. 4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment;available in 3.3 ft x 65 ft rolls; meets ASTM D197). 4.4 Lastobond Shield HT is a self-adhering,woven polyethylene surl aced,high temperature,SBS modified bitumen roof underlayment;meets ASTM D1970. NEMO ETC,LLC Evaluation Report 518010.06.09-R12 Certificate of authorization 1132455 6T"EDITION(2017)FBC NON-HVHZ E ALUATION FL2569-1134 Soprema Roof Underlaymen s Revision 12:02/12/2018 Page 2 of 8 NEMO etc. 4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene su faced, SBS modified bitumen roof underlayment available in two.widths;36 and 45 inch;meets ASTM D1970. 4.6 Lastobond Pro HT-S is a self-adhering,woven polyethylene surfa ed, high temperature,SBS modified bitumen roof .'underlayment;meets ASTM D1970. 4.7 Enviro5hield is a self-adhering, woven polyethylene surfaced high temperature, SBS modified bitumen roof Iunderlayment;'meets ASTM D1970. 4.8 Lastobond 195,is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.9 Lastobond Eaves Protection Sheet is a self-adhering, glass-ma reinforced, sand-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.10 Lastobond Eco.is a self-adhering, glass-mat reinforced, sand-s rfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.11 Lastobond Smooth Seal HT is a self-adhering, glass-mat rein orced, film-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.12—RESISTO-L-B1236-iis_a-self�adhering,--glass_matteinfu-r-ced,sand-s rfaced,--5135-modified-bifemen-roof-underlaym`ent;= �,wi�thha-36-inch sheet_width;-meets ASTM-D1970E:::� 4.13 PrimeSource Grip-Rite Eave & Valley Protector is a self-a hering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet widt ; meets ASTM D1970. 4.14 RESISTO LB1244 is a self-adhering,glass-mat reinforced, sand-surfaced,SBS modified bitumen roof underlayment, with a 44-inch sheet width;meets ASTM D1970. 4.15 `Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04 12). 5. LIMITATIONS: 5.1 ,This is a building code evaluation. Neither NEMA ETC, LLC nor lobert Nieminen, P.E. are,in any way,the Designer of Record for any project on which this Evaluation Report,or pi evious versions thereof, is/was used for permitting ,or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of 'this product. 5.4 Soprema Roof Underlayments may be used with any prep red roof cover where the product is specifically referenced within FBC approval documents. If not listed, request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined wit supporting data for the prepared roof covering. 5.5 :Allowable Roof Covers: TABLE 1: ROOF COVEROPTIONS Wood or Slate or Asphalt Nail-On Foam-On Composite Underlayment Shingles Tile Tile Metal Shakes& Composite Shingles Slate Lastobond TU HT Yes Yes Yes See 5.5.1 Yes Yes Yes Lastobond Shield/Pro HT-N/ Yes No No No Yes Yes RESISTO SA SMOOTH PLY 40 Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes Enviro5hield Yes No No Yes Yes Yes I NEMO ETC,LLC Evaluation Report 518010.06.09-R12 Certi/kate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ E ALUATION FL2569-1114 Soprema Roof Underlaymer ts Revision 12:02/12/2018 Page 3 of 8 i ONEMO etc. TABLE 1: ROOF COVER OPTIONS Wood or Slate or Asphalt Nail-On F am-On Composite Underlayment Shingles Tile Tile Metal Shakes& Composite Shingles Slate Lastobond Eaves Protection Sheet/ Yes No No No Yes Yes Lastobond 195 Lastobond ECO /RESISTO LB1236, Grip-Rite Eave&Valley Protector/ Yes No No. No Yes Yes RESISTO LB1244 Lastobond Smooth Seal HT Yes INo No Yes Yes IYes ,Colphene FR GR Yes Yes Yes No Yes Yes See 5.5.1 5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations. TABLE IA:ALLOWABLE TILE ADHESIVE/ r Adhesive Florida Product Approval Underlayments Dow TileBond'" FL22525 Lastobond TU HT ICP Adhesives Polyset®AH-160 FL6332 Lastobond TU HT or Colphene FR GR 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protectio Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 o Lastobond Smooth Seal HT applied to: i- Plywood;ASTM D41 primed plywood;OSB;ASTM D41 pri ed OSB;Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concr te. Colphene FR GR applied to: Y Plywood;ASTM D41 primed plywood;ASTM D41 primed tructural concrete. Note: i While not required over plywood, OSB or Southern Yell w Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cove is not slated for installation within 24 hours. `r Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond-to-Insulation: Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTF PLY 40,Lastobond'Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protectio i Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector, RESISTO LB124 , Lastobond Smooth Seal HT or Colphene FR GR applied to: 'r Dens Deck Prime;SECU ROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof c verings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems (Lastobond TU HT only), insulation attachment hall be designed by a qualified design professional and installed based on testing of the insulation/underlaymen t system in accordance with FM 4474,Appendix D, Testing Application Standard TAS 114,Appendix J or UL1807 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida ProductAj 1provalfor Overturning Moment Resistance Performance. MEMO ETC,LLC Evaluation Report S18010.06.09-R32 Certificate ofAuthorizotion#32455 6T"EDITION(2017)FBC NON-HVHZ E ALUATION FL2569-1114 Soprema Roof Underlaymen s Revision 12:02/12/2018 Page 4 of 8 i i I i I i NEMO etc. 5.6.3 Bond to Mechanically Attached Base Laver: j Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH LY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO i L61236, Grip Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: i i ASTM D226,Type I or II felt;Sopra-G; Modified Sopra-G. For installations under mechanically attached prepared roof c verings,base layer shall be attached per minimum codified requirements. For installations under foam-on tile sy tems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012(04-12). i 5.6.4 Wind Resistance for Underla ment Systems in Foam-On Tile Aplications: FRSA/TRI April 2012(04-12)does not address wind uplift resistance of all underlayment syste s beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistan e based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determi ation of design wind pressures. #1' Maximum Design Pressure=-45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)Elastocol Stick,Elastocol 600c or ESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR,self-a hered. #2 Maximum Design Pressure=-67.5 psf: Deck: Structural concrete to meet project re uirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. #3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority H ving Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to re ove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER IUnderlayment: Lastobond TU HT, self-adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and a isure there are no voids/bridging at side and end- laps. #4 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically ttached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch Ips and 6-inch o.c. in three(3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered 5.6.4.1 All other direct-deck, adhered Soprema underlayment systems beneath foam-on tile systems carry a Maximum Design Pressure of-45 psf. I NEMO ETC,LLC Evaluation Report 518010.06.09-1112 Certificate o/Authorization#32455 6TH EDITION(2017)FBC NON-HVHZ E LUATION FLZ569-1114 Soprema Roof Underlaymen s Revision 12:02/12/2018 Page 5 of 8 I ONEMO I etc. 5.6.4.2 For mechanically attached Base Sheet, the maximum design ressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appe dix A,Table 1A. Alternatively, the maximum design pressure for the selected ssembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this ase, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resis the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data She1-291-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations s t forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. I 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,RESISTO LB1236, Grip-Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation. Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT or Lastobond Pro HT- S,Enviro5hield shall'not be left exposed for longer than 90-da s after installation. Lastobond TO HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations TAS 103 per FRSA TRI Ar 12)): When loading roof tiles on the underlayment in direct-deckile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by usin battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE UmITATIONS FOR DIREcT-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max.10-tile stack 6:12 Lugged Max.10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted,followed by 8 tiles high 6:12 on slope,as shown below) Lastobond TU HT Lugged Colphene FR GR Flat Max.10-tile stack 5:12 Lugged Max.10-tile stack 6:12 i NEMO ETC,LLC Evaluation Report 518010.06.09-1112 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ E ALUATION FL2569-1114 Soprema Roof Underlayme its Revision 12:02/12/2018 Page 6 of 8 ONEMO etc. 6. INSTALLATION: 6.1 : Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the s ecifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime t1 e substrate with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER(if applicable). 6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RI SISTO'SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,EnviroShield,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,RESISTO LB1236,Grip-Rite Eave&'Valley Pro ector,RESISTO LB1244 or Colphene FR GR: 6.3.1 Shall be installed in compliance with the requirements for ASM D1970 underlayment in'FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 ' Non-Tile Applications: While priming is optional,Soprema recommends priming with IIElastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation withih 24 hours. Apply sheet parallel to the roof edge. Roll out approximatel 10 ft of membrane and peel back the first 3 ft of release film. , Adhere the exposed part to the substrate and unroll the remai ing membrane as far as possible. Once the entire length of membrane is in place, peel-off the r lease film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. ' Horizontal seams should be minimum 3-inches, configured to hed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the cours below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12, Soprema recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place,working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Lastobond TU HT or-Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installatior Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications, reference is made to Section 16.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tileslippage and/or damage to the underlayment. See Table 2 herein,and Soprema published requirements for tiles aging. REQUIREMENTS:7. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.' I NEMO ETC,LLC Evaluation Report 518010.06.09-1112 Certiftare o(Authorizotion#32455 6T"EDITION(2017)FBC NON-HVHZ E ALUATION FL2569-1114 Soprema Roof Underlayme is Revision 12:02/12/2018 Page 7 of 8 1 ONEMO I etc. 8. MANUFACTURING PLANTS:I Contact the noted QA agency for information on product locatins covered for F.A.C. 61G20-3 QA requirements. The following plants have qualified products under their respectiv physical properties specifications. i Plant Specification Product(s) Lastobond Shi Id,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Drummondville, Lastobond Pro HT-N,Lastobond Pro HT-S,EnviroShield,Lastobond 195, QC(Canada) ASTM D1970 Lastobond Eav s Protection Sheet,Lastobond Eco,Lastobond Smooth Seal HT,RESIS 10 LB1236,PrimeSource Grip-Rite Eave&Valley Protector,RES STO LB1244 ` ASTM D1970&FRSA/TRI 04-12 Colphene FR G Wadsworth,OH Lastobond 195 Lastobond Eaves Protection Sheet,Lastobond Eco, ASTM D1970 Lastobond Smkotector, th Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley RESISTO LB1244 ASTM D1970&FRSA/TRI 04-12 Lastobond TU T;Colphene FR GR Gulfport,MS Lastobond 19%Lastobond Eaves Protection Sheet,Lastobond Eco, ASTM D1970 Lastobond Sm oth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite E Eave&Valley 3rotector,RESISTO LB1244 QUALITY9. UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report S18010.06.09-1112 Certificate of Authorizorion#32455 6T"EDITION(2017)FBC NON-HVHZ E ALUATION FL2569-1114 Soprema Roof Underlayme is Revision 12:02/12/2018 Page 8 of 8 MIAMI DARE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE OA www.miamidade.gov/economy GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA'is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-'ade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and thle AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. R reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCWTION: GAF Cobra®Ridge Runnefrm Exhaust Vent for Roof Ridge LABELING: Each unit shall bear a permanent label with the manuf Icturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless o herwise noted herein. RENEWAL of this NOA shall be considered after a renewal applicat on has been filed and there has been no change in the applicable building code negatively affecting the performance o this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse o this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically termin to this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the uler by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Bu i ding Official. This revises and renews N0A#14-1022.10 and consists of pages 1 through 4. The submitted documentation was reviewed by Freddy Sernino NOA No.: 17-0822.06 MIAMI-DAD,COUNTY Expiration Date: 11/01/22 Approval Date: 10/19/17 Page 1 of 4 I ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Ventilation Material: Plastic Minimum Slope: 2:12 I TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT I ' Product Dimensions Test Product Specification Description GAF Cobra®Ridge 20' Length(Roll) TAS 100 Low profile attic ridge vent in roll form for Runner"111 Exhaust 11.5"Width installation under ridge shingles. Vent for Roof Ridge .7"Height i I MANUFACTURING LOCATION 1. Cumming,GA. EVIDENCE SUBMITTED Test Agency/Identifier Name Report Date Architectural Testing ASTM D 1929 D8532.01-106-18 07/10/14 ASTM D635 D8532.01-106-18 07/10/14 I ASTM D 2843 D8532.01-106-18 07/10/14 Intertek/Architectural Testing ASTM G155 E2672.01-106-18 07/08/15 ASTM D638 E2672.01-106-18 07/08/15 PRI Construction Materials Technologies,Inc. TAS 100(A) GAF-783-02-01 08/01/17 I I I i ' NOA No.: 17-0822.06 QMIAMMI-DMADE COUNTY Expiration Date: 11/01/22 Approval Date: 10/19/17 Page 2 of 4 i I APPROVED APPLICATIONS Tradename: GAF Cobra®Ridge Runnefrm Exhaust Vent for Roof Ridge System Type: Mechanical attachment of ridge vent. Slot: Determine whether the rafters are truss or ridgepole construction. Chalk a cut line of each side of ridge. Cut a 1-3/4" (no ridge board)or 3'/4"(ridge board)maximum slot along the apex of the roof by cutting 7/8" (no ridge board) or 15/8"(ridge board)on each side of the ridge. The slot shall terminate 1 foot shorter at each end than the total length of ridge vent used. Installation: Place,center and conform the end of a piece of ridge vent at each end of slots. Mark the location of the end of the baffle. Strike a chalk line on both sides of the ridge to produce baffle alignment. Place vent sections centered over the slot using a chalk line. Place nails at pre-marked locations on top of the vent.Nails shall be minimum 12 guage 1-1/411 j corrosion resistant ring shank roofing nails,a minimum 3/,6"penetration into wood substrate is required. I Ridge Shingle: Using nail lines provided on top of vent. Nail cap shingles in place,as per ridge cap shingle manufacturer's installation instructions.Nails shall be minimum 12 gauge 1-1/4 corrosion resistant ring shank roofing nails,a minimum 3/16"penetration into wood substrate is required. Ventilation Calculations: Refer to manufacturer's published literature. LTMTTATIONS: 1. Refer to applicable Building Code required ventilation. 2. Ridge Vent shall comply with applicable Building Code. 3. Ridge Vent shall not be installed on roof mean heights greater than 33 feet. 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. j5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility,and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. I MIAMI•DADE COUNTY I NOA No.: 17-0822.06 MIAMI•DADE COUNTY Expiration Date: 11/01/22 Approval Date: 10/19/17 Page 3 of 4 DETAIL A I � i 1 I I 20'Length I au i 1 BOTTOM VIEW TOP VIEW 11-5"Wide 7" MUZIE3131=_T END VIEW END OF THIS ACCEPTANCE NOA No.: 17-0822.06 MIAMI-DADE COUNTY Expiration Date: 11/01/22 Approval Date: 10/19/17 Page 4 of 4 MIAMI-DADE COUNTY M'1AQ+'tl' PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline HD',Timberline'Natural Shadow,Timberline'American Harvest",and FortitudeT`I Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. i ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the ! expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 14-1022.20 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 16-0811.11 MIAMI-DAD,COUNTY Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 1 of 6 i ROOFING ASSEMBLY APPROVAL Categorv: Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Type: Wood i SCOPE This approves GAF Timberline HD®,Timberline'Natural Shadow',Timberline American*Harvest`$,and j FortitudeT"Shingles as manufactured by GAF as described in this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Tiiriberline-HDA'' 13f'4'=x 39 3%s' iTAS-410' .=Fiberglass•reihfotbed lieavy-weiblit-asplia_lt Manufacturing r__roof shingle,with_a.laminate_proftei Locations_41,2,3,9,^5,_6, GAF Timberline Natural 13 '/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Shadow' roof shingle-.with a laminate profile Manufacturing Locations#1,2,3,4,5,6,7 GAF Timberline'American 13 1/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Harvest` roof shingle,with a laminate profile Manufacturing Locations#2,4,5, 6 GAF FortitudeT111 13 '/a'x 39 3/8'• TAS 110 Fiberglass reinforced heavy weight asphalt Manufacturing roof shingle,with a laminate profile Locations#1,4 MANUFACTURING LOCATION 1. Tampa, FL 2. Michigan City, IN 3. Baltimore,MD 4. Myerstown,PA 5. Ennis,TX 6. Tuscaloosa,AL 7. Dallas,TX i i i NOA No.: 16-0811.11 MIAMI•DADECOUNTY Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 2 of 6 i EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories,LLC ASTM D3462 4787344101 07/25/16 Underwriters Laboratories,Inc. ASTM D3462 I ICA48924 10/24/11 Underwriters Laboratories,Inc ASTM D3462 IOCA21994 04/22/11 Underwriters Laboratories,Inc ASTM D3462 I OCA28717 07/26/11 Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06 r Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories,Inc. ASTM D3462 06NK05159 08/09/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05 i Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02 Underwriters Laboratories,Inc. ASTM D3462 03NK26444 10/17/03 Center for Applied Engineering ASTM D3462 257989 05/13/97 Underwriters Laboratories,Inc. TAS 107 O1NK45803 04/13/94 i Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05 Underwriters Laboratories,Inc. TAS 107 02NK41811 11/11/02 Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/0') Underwriters Laboratories,Inc. TAS 107 04CA13850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies, Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies, Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologies, Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt Technologies, Inc. TAS 100 GAF-1.16-02-02 03/23/06 PRI Asphalt Technologies, Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELK-085-02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21/02 ELK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10/09/03 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20'-' of the Florida Administrative Code. NOA No.: 16-0811.11 QMIAMMI-D�ADECOU=NTY Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 3 of 6 i i I1 INSTALLATION i 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be;in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A',attached. I 5. Nailing shall be in compliance with Detail'B',attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade f County Product Control Seal as shown below. CMIAMI-DADE COUNTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. , 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. i NOA No.: 16-0811.11 MIAMI•DADECOUNTY . � Expiration Date:02/21/22 Approval Date: 02/09/17 Page 4 of 6 1 I � DETAIL A I COURSE LAYOUT f DECK I ` f FULL 5th 17" OFF 4th 11" OFF 3rd 6" OFF 2nd FULL 1 st I NOA No.: 16-0811.11 MIAhn•DADE COUNTY Expiration Date: 02/21/22 Approval Date:02/09/17 Page 5 of 6 I i DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN 39-3/8" (t m) 14-1(36-45mm) " 14-11268-45mm) " (368-445mm) (368-446mm) 6-1/2"-9-1l2" 6-1/2"-9-1/2" ail guide line i (165.241mm) (165-241mm) 5314"-6-1/4"133 (146mm_159 mm)37mm) - -0— - -A&- - 4D- - - - 41k- 1 1Z'-2-vz" from bottom of shingle 03-64 Self seal adhesive if on back ENHANCED NAILING PATTERN - six nails per shingle* required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6" (152mm)from bottom of of shingle, above the cut outs, as shown. Nails must not be exposed. END OF THIS ACCEPTANCE NOA No.: 16-0811.11 MIAMI•DADE COUNTY Expiration Date:02/21/22 Approval Date: 02/09/17 Page 6 of 6 I i i 1