Loading...
HomeMy WebLinkAboutProduct Approval i 2121/2011 Florida Building Code Online x .cw 41 v '•u^' 1a,"��y� ,. s t �� ,err, .' BCIS Homej Log In User Registration i Hot Topics Submit Surcharge ; Stats&Facts i Publications FBC Staff ) BCIS Site Map j Links Search Florida L40%no ,? t3aa Product Approval i I USER:Public User F.;tY•.i P Product Approval Menu>Product or Application Search>implication List>Application Detail Df , FL# FL15216-R3 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer InterWrap,Inc. Address/Phone/Email 32923 Mission Way Mission, NON-US 00000 (551)574-2939 mtupas@interwrap.com Authorized Signature Eduardo Lozano elozano@interwrap.com Technical Representative Eduardo Lozano Address/Phone/Email 32923 Mission Way Mission, NON-US 00000 (778)945-2891 elozano@interwrap.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida i Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA,Inc. -QA Entity Quality Assurance Contract Expiration Date 09/30/2019 Validated By John W. Knezevich, PE v Validation Checklist-Hardcopy Received Certificate of Independence FL15216_R3_COI_2017_Q1_COI_Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970(tear) 2015 ASTM D226(physicals) 2009 I Equivalence of Product Standards Certified By Sections from the Code I I https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgv3yVVKJZIQRAdhyI2u8kQGnf9ayHyTiLG8tWOuK8nwXA%3d%3d 1/2 Florida Building Code Online Page 1 of 2 777 - BCIS Home•; Log In User Registration Hot Topics F Submit Surcharge Stats&Facts Publications FBC Stall j BCIS Site Map i Links Search Florida Product Approval �n USER:Public User Product Aooroval Menu>Product or Aoolication Search>Aoolication List>Application Detail .p FL# FL18355-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived i Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com Authorized Signature Kerri Eden kerri—eden@tamko.com Technical Representative Kern Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer I_i Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R.Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 01/07/2019 Validated By Locke Bowden Validation Checklist-Hardcopy Received Certificate of Independence FL18355 R4 COI TBP15001.4 2017 FBC Eval Report Shinales final.odf Referenced Standard and Year(of Standard) Standard Year ASTM D 3161 2016 ASTM D 3462 2010 ASTMD D 7158 2011 TAS 100 1995 Equivalence of Product Standards Certified By Approved Testing Lab FL18355 R4 Eauiv UL letter for standards for FBC 2017.1)df Sections from the Code I I hftps://floNdabuilding.org/pr/pr app_dd.aspx?param=wGEVXQwtDquvosrHazGXQW83MPT3uofKzDlM2Xu9wuWmY6PQIJ... 12/19/2017 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY : FILE # 4469251 OR BOOK 4168 PAGE 1305, Recorded 08/13/2018 12:29:47 PM NOTICE OF COMMENCEMENT Permit No. Property Tax ID No. State of Florida,County of St.Lucie The Undersigned hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement. Legal Description of property and address if available 13o1�(c�o�-0233—�_qK� *!K General description of improvements � Owner/lessee -VE2fl 50 f i,/ /Ngg ' �/ j Address . O. ! q3 ,)" J -CO43 Interest in property: Fee Simple Title holder(if other than owner) Address ��``�� ,,//^^ nn Contractor 0� Phone# 40 Pi Address t 5 Z Fax# Surety Phone# °' e= a., Address Fax# 3> ;z H m o Amount of Bond rn r�CD 0 0 �� n ��rz�o Lender Phone# 021* ?,°,:=! Address V q Fax# �:P0 0 4 Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as I leams o= by Section 713.13(a)7.,Florida Statues: Name Phone# T Cn Address Fax# s cn In addition to himself,owner designates -'' rn Phone# Fax# to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Expiration date of nott commencement is one year from the date of recording unless a different date is specified. WARNING TO OWNER:` ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CH.713.13,'F.S.,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE 30B SITE BEFORE THE FIRST INSPECTION. IF YOU INTENDTO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNE EFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMM6NCMENT. 44- t Vev/Yl/],/ Owner/Lessee w er's Lessee'sAutho ed irector/Partner/Manager/Signature Signatory's TitieJOIT ee State of Florida,County of &vi{R.l� ,/ //? Aclmowled ed before me this ,day of u�� /� 20 ,by / , w is erson n to me r who has produced as identification. g-A � to anis arez gSignature of N Typ9INI& tm p (Seal)! Title:Notary Public Commission Number. �R � www.AARONNOTARY.001u1 i Certificate of Authorization No. 29824 CREEK 17520 Edinburgh Dr Tampa,FL33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017) Manufacturer: TAMKO BUILDING PRODUCTS Issued September 25, 2017 220 West 41"Street Joplin, MO 64801 (417)624-6644 Manufacturing Plants: Joplin, MO Phillipsburg, KS Frederick, MD Dallas,TX Tuscaloosa,AL Quality.Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES Entitv Report No. Standard Year PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995 UL LLC,(TST9628) 02NK9507 ASTM D 3161 2016 UL LLC(TST9628) 04NK24366 ASTM D 3462 2010A UL LLC'(TST9628) 05NK28006 ASTM D 6381 2008(2013)e1 UL 2390 ASTM D 7158 2011 UL LLC(TST9628) 06NK03898 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 08CA59132 ASTM D 3161 2016 UL LLC(TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 1 OCA50498 ASTM D 3462 2010A UL LLC,(TST9628) 1 OCA64882 ASTM D 3161 2016 UL LLC(TST9628) 11NK14014 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 12CA24551 ASTM D 3161 2016 UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e1 UL LLC(TST9628) 4787043752 ASTM D 3161 2016 UL LLC(TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A 1 CREEK Technical Services LLC(ANE11669) TBP15001.3 Calculations 2017 TBP15001.4 FI-18355-R4 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I I I c, F TAMKO BUILDING PRODUCTS CREEKAsphalt Shingles i TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION Elite Glass-Seal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4"x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Heritage® 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas; Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Joplin,;Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Vintage® 17-1/2"x 40",ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage®Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.4 FL18355-R4 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I 1 GREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC INSTALLATION Elite Glass-Seal® Basic Wind Speed(Vuit): Max. 194 mph (Frederick,Joplin& Basic Wind Speed(Vasd): Max. 150 mph Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Glass-Seal new construction; Min. 15/32 in. plywood existing (Frederick,Joplin (Non- construction. HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAILS }int Nailing ----------------------- -------- -----------------­-------------------- 8-718" Area --------------------------------- -----------------==---------------------------------------------- - 5-1/8" Butt Edge Figure 1. Elite Glass-Seal&Glass-Seal 4 Nail Pattern (Non-HVHZ only) NAILS Nailing---_ -------- -------- -------- ---------------- - -------- -------- --- - -- Er7/8�� Area --------- -------- -� = 5-1I8" Butt Edge Figure 2. Elite Glass-Seal&Glass-Seal 6 Nail Pattern i TBP15001.4 FL18355-R4 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS CREEKAsphalt Shingles TECHNICAL SERVICES, LLC I Heritage® Basic Wind Speed(Vit): Max. 194 mph (Dallas, Frederick,Joplin, Basic Wind Speed (Vasa): Max. 150 mph Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Heritage®Premium new construction; Min. 15/32 in. plywood existing (Dallas, Frederick construction. Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 15/32 in. plywood or wood plank for Heritage®Woodgate new construction; Min. 7/16 in. OSB existing construction. (Dallas,&Frederick) Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either°4 Nail Pattern"or"6 Nail Pattern"detailed below. FASTENERS NAIL ZON E COMMON BOND EXPOSURE 6-6/8" 12-11211--►�- 12-31$" --►�- 1 2-112"--►I �--1" Figure 3. Heritage®, Heritage®Premium, and Heritage®Woodgate(Dallas) 4 Nail Pattern (non-HVHZ only) FASTENERS NAIL ZONE COMMON BOND 6-118" EXPOSURE 5-5/8" 1' �7-1/2' t-7-1/2"-►� 7-/8`11- l-7-1/2" -7-1/2"-►� hl--i" Figure 4. Heritage®& Heritage®Premium 6 Nail Pattern i TBP15001.4 FL18355-R4 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. i j TAMKO BUILDING PRODUCTS CREEK Asphalt Shingles TECHNICAL,SERviCES, LLC NAIL 20NE1 ASTENER -- . CI)MI'aiON BOIVt1' il$ ExPOSURE 5 518° ,1';��`: �7�112+;�„�,7-112'Gl�7=H18,'� ►�i-71321!►�t7 2 ,., �,,, Figure 5. Heritage@ Woodgate 6 Nail Pattern tt 12-1/2"_ �---- } f i ® Common Bond ; FASTENERS m � 39-3/80 T � � II � Figure 6. Heritage@, Heritage@ Premium, &Heritage®Woodgate Alternate 6 Nail Pattern LINE ...•. 7;718„ "Om; -__ — -- �:__�:__ ___�: - 'NAlL;Z4NE" EI3GE .COlU MON, BOND tkob LIRE ACCEPTABLE FASTENER LOCATION, DO..NOT"FASTEN ALONG EDGE,OF =_ _ . •'COMMON'BOND PRE FERRED FASTENER LOCATIO.f Figure 7. Heritage@(Tuscaloosa) Expanded Nail Zone Nail patterns from Figures 3,4,and 6 may be placed in the nail zone as described above i TBP15001.4 FL18355-R4 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK 1 Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. {`' TAMKO BUILDING PRODUCTS CREEKAsphalt Shingles TECHNICAL SERVICES, LLC I Heritage®Premium Basic Wind Speed(V„ic): Max. 194 mph (Frederick) Basic Wind Speed (Vasd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. . Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS /COMMON BOND Wj 51/2" IXPOSURE 5" 1"-►I �-- 11"-►�F^- 12 --►�-11 -►I �-1If Figure 8. Heritage®Premium (Frederick) 4 Nail Pattern (non-HVHZ only) NAIL ZONE/ FASTENERS /COMMON BOND 111117— 51/211 EXPOSURE 5" IL-1" Figure 9. Heritage®Premium (Frederick) 6 Nail Pattern TBP15881.4 FL18355-R4 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS CREEKAsphalt Shingles TECHNICAL SERVICES, LLC Heritage®Woodgate Basic Wind Speed (Vit): Max. 194 mph (Frederick) Basic Wind Speed (Vmd): Max. 150 mph_ Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation (Non-HVHZ): Installed with .5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERSCOMMON BOND WT 5-112" EXPOSURE 5" 1' 11" -►�-12-3/13'r---�-. 11" Figure 10. Heritage®Woodgate (Frederick) 4 Nail Pattern (non-HVHZ only) NAIL ZON P FASTENERS COMMON BOND T 51 � HEXPOSURE,5` 1��� � g-112"-�1.3'�9�/8"-1►�#3'+►�8-112��� �1�� Figure 11. Heritage®Woodgate (Frederick) 6 Nail Pattern I TBP15001.4 FL18355-R4 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS CREEKAsphalt Shingles I TECHNICAL.SERVICES, LLC Heritage®Vintage® Basic Wind Speed (Vit): Max. 194 mph (Phillipsburg) Basic Wind Speed (Vwd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either°5 Nail Pattern"or"6 Nail Pattern"detailed below. aa' Ecpsure z rbxh 6•. Fasteners Pkil one tarn" s' Ex, 47M` 9.114` 9.1M`��4.7M` -t/ t �--t O-W Figure 12. Heritage®Vintage® 5 Nail Pattern (non-HVHZ only) r Fpmm Notch T Www« NOR — — — zone 17-1/2' 3` Btpusa� ' F7JlF-��1 I�"�i61�bNe' Figure 13. Heritage®Vintage® 6 Nail Pattern TBP15001.4 FI-18355-R4 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC Hip&Ridge Basic Wind Speed(V„it): Max. 194 mph (Frederick&Joplin) Basic Wind Speed(Vasd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction of prevailing wind a�rt p5-118" exposure here— Fn] ere—Fl II Start Figure 1 here 5-1/8"exposure astenerFastener Figure 2 �� Figure 3 1/4 Figure 14. Hip& Ridge (Frederick&Joplin) i TBP15001.4 FL18355-R4 Page 9 of 11 Thisevaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 1 I CRETAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC Vintage®Hip&Ridge Basic Wind Speed (Vun): Max. 194 mph (Phillipsburg) Basic Wind Speed ,V asd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction of prevailing wind Starrrt. 511 exposure he Start Figure 1 here 5" exposure 1" Fastener F�2 ever �5-1/2" Figure 2 1/4's Figure 3 Figure 15. Vintage®Hip & Ridge(Phillipsburg) i TBP15001.4 FI-18355-R4 Page 10 of 11 j This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. i TAMKO BUILDING PRODUCTS CREEK Asphalt Shingles TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6). Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7)' Installation of the evaluated products shall comply with this report, the FBC, and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6t'Edition (2017)as evidenced in the referenced documents submitted by the named manufacturer. SPRY R. �� • . 2017.09.25 No 74021 11 :31 :41 _ • * _ ..Mal W.agtaM0.wwl .n era._.._...., = = - -04'00' :� • STATE OF o'•. �i''�`�•;C� Zachary R. Priest, P.E. AI �`` Florida Organization No.lon 21 A E116 9 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP15001.4 FL18355-R4 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I I oVEM01 etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY ® • ® • • j Owens Corning Roofing and Asphalt,LLC Evaluation Report 140510.02.12-114 One Owens Corning Parkway FL15216-114 Toledo,OH 43659 Date of Issuance:02/17/2012 (740)321-6345 Revision 4:04/19/2018 SCOPE: This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: RhinoRoof Underlayments LABELING: I Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distribd tors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 3. Prepared by: ,�,,++<<�r��•,,,,; Robert J.M. N ieminen,P.E. V.^w;. -=^;.+' The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E.on 04/19/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. MEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. NNEMOletc. ROOFING COMPONENT EVALUATION: •P Product Category: Roofing Sub-Category: Underlayment Compliance Statement: RhinoRoof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, has demonstrated compliance with the following sections of the 6th Edition (2017)Florida Building Code through testing in ;accordance with applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. �TANDARD8:' Section' Properties Standard Year 1507.1.1,R905.1.1 Exception Unrolling,Breaking Strength,Pliability ASTM D226 2009 1507.1.1,R905.1.1 Exception Tear Strength ASTM D1970 2015 TAS 110 Pull-through resistance TAS 117(8) 1995 13., REFERENCES:� Entity `°,v Examination Reference Date _ ITS,(TST1509) Physical Properties 100539395COQ-006 10/27/2011 ITS(TST1509) Physical Properties 100539395COQ-002 10/27/2011 ITS(TST1509) Physical Properties 100539395COQ-006 03/14/2014 PRI?(TST5878) ASTM D1970;Tear strength OCF-330-02-02 10/03/2017 PRI:(TST5878) TAS 117(8);Pull-through OCF-422-02-01 04/03/2018 ITSi(QUA1673) Quality Control Service Confirmation 09/30/2017 4. . ... s • 4.1 RhinoRoof U20 is a multilayered polymer woven coated synthetic roof underlayment available in 42-inch wide rolls, and can be produced in various other sizes;meets FBC 1507:1.1&R905.1.1(Exception). 5.1LIMITATIONS' 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.4 RhinoRoof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE ROOF COVEROPTIONS Underlayment Asphalt Wood Shakes Slate or', Shingles 'Nail-On Tile-' Foam-On Tile Metal `&Shingle's Simulated Slate RhinoRoof U20 Yes No:; � :No «'� �` Yes �� ° Yes No 5.6 Exposure Limitations: RhinoRoof U20 shall not be left exposed for longer than 30-days after installation. NEMO ETC,LLC Evaluation Report 140510.02.12-R4 Certificate ofAuthorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL15216-R4 RhinoRoof Underlayments Revision 4:04/19/2018 Page 2 of 4 (N� EM® etc. 6.1 RhinoRoof Underlayments shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 ;Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.3 RhinoRoof U20: i 6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table j 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet- width. 6.3.2 Fasteners: For exposure<24 hours, corrosion resistant fasteners may be 1-inch roofing nails with a 3/8-inch diameter head, minimum 1-inch diameter plastic or metal cap nails or FBC HVHZ nails&1-5/8"diameter tin caps(with the rough edge facing up). The use of staples is prohibited. For exposure>24 hours up to maximum 30 days, corrosion resistant fasteners shall be minimum 1-inch diameter plastic or metal cap nails or FBC HVHZ nails& 1-5/8" diameter tin caps (with the rough edge facing up). The use of staples is prohibited. 6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "..except metal cap nails ,shall be required where the ultimate design wind speed, V„!G equals orexceeds 150 mph." ;Owens Corning Roofing and Asphalt,LLC has furnished data to permit the use of 1-inch diameter plastic cap nails in lieu of metal cap nails for these applications, when the RhinoRoof U20 underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1. 6.3.3 Single Laver: Roof Slope>4:12: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. Refer to Owens Corning Roofing and Asphalt, LLC recommendations for alternate lap configurations and/or the use of sealant under certain conditions. For exposure<24 hours,use of every-other fastening location printed on the surface is acceptable. For exposure >24 hours up to maximum 30-days,use of every fastening location printed on the surface is required. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens on the same day. Battens shall not be positioned over cap nails. If .this occurs, remove the cap nail and patch the hole in accordance with Owens Corning Roofing and Asphalt, LLC published instructions. 6.3.4 Double Laver;2:12<Roof Slope<4:12: ,End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum half-sheet-width plus 1-inch. Double layer application; begin by fastening a half-width plus 1-inch starter strip along the eaves. Place a full- width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.3.3, but maintaining minimum half-width plus 1-inch side(horizontal)laps, resulting in a double-layer application. NEMO ETC,LLC Evaluation Report 140510.02.12-114 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL15216-114 RhinoRoof Underlayments Revision 4:04/19/2018 Page 3 of 4 i NMEMO I etc. 117. BUILDING PERMIT RE001REMENT5.:: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. ;Qingdao,China 9, QUALITY Intertek Testing Services NA Inc.—QUA1673;(608)836-4400 -END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 140510.02.12-114 Certificate of Authorization 1132455 6TM EDITION(2017)FBC NON-HVHZ EVALUATION FL15216-R4 RhinoRoof Underlayments Revision 4:04/19/2018 Page 4 of 4 II I