HomeMy WebLinkAboutProduct Approval MIAMI,OAD�
MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Owens Corning Roofing and Asphalt,LLC
One Owens Corning Parkway
Toledo,OH 43659
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Duration®,Duration®Premium,TruDefmition®Duration®,and TruDefinition®Duration®
Designer Colors Collection
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No.12-0309.01 and consists of pages 1 through 6.
The submitted documentation was reviewed by Gaspar J Rodriguez.
Ay%JA_
NOA No.: 16-0425.01
MIAMI DARE COUNTY Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 1 of 6
i
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves a roofing system using Owens Corning Duration@ and Duration@ Premium asphalt shingles
manufactured by Owens Corning as described in Section 2 of his Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Specifications Product Description
Duration@ 131/4"x 39'/8" TAS 110 A heavy weight,fiberglass reinforced
Manufacturing Locations#1,2 four tab asphalt shingle with
continuous bead of sealant.
Duration®Premium; 13 la"x 39 /8" TAS 110 A heavy weight,fiberglass reinforced
TruDefinitionO Duration@); four tab asphalt shingle with large nail
TruDefinitiong Duration® area with continuous bead of sealant.
Designer Calors Collection
Manufacturing Location#1,2,3,4
Duration@ 131/4"x 393/81, TAS 110 A heavy weight,fiberglass reinforced
Manufacturing Location#1,2,3 four tab asphalt shingle with dashed
bead of sealant.
Duration@ Premium; 131/4"x 39 3/8" TAS 110 A heavy weight,fiberglass reinforced
TruDefinition®Duration?; four tab asphalt shingle with dashed
TruDefinition@ Duration® bead of sealant.
Designer Colors Collection
Manufacturing Location#1,2,3,4
MANUFACTURING LOCATION
1. Jacksonville,FL
2. Memphis,TN
3. Savannah,GA
4. Irving,TX
MIAMMADE COTY NOA No.: 16.0425.01
��� .••_ Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 2 of 6
I
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
PRI Asphalt Technologies,Inc. OCF-157-02-01 TAS 100 10/26/10
OCF-102-02-01 TAS 100 11/12/07
OCF-156-02-01 TAS 100 10/26/10
OCF-163-02-01 TAS 100 12/10/10
OCF-164-02-01 TAS 100 12/10/10
OCF-098-02-01 TAS 100 02/22/07
OCF-099-02-01 TAS 100 02/26/07
OCF-102-02-01 TAS 100 11/12/07
OCF-172-02-01 TAS 100 05/26/11
OCF-179-02-01 TAS 100 02/02/12
Underwriters Laboratories,Inc. 07CA39536 TAS 107 11/11/07
03NK04954 TAS 107 03/28/03
03NK04954 TAS 107 03/11/03
IONK13947 TAS 107 11/12/10
11CA15662 TAS 107 05/27/11
11NB21712 TAS 107 02/18/12
07CA02026 ASTM D 3462 01/26/07
12CA12180 ASTM D 3462 03/01/12
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A',attached.
5. Nailing shall be in compliance with Detail'B',attached.
LABELING
1. Shingles shall be labeled with the Miami-Dade Seal as seen below, or the wording"Miami-Dade County
Product Control Approved".
CMIAMI&MADE COUNTY
NOA No.: 16-0425.01
M1AM1•DADE COUNTY Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 3 of 6
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
DETAIL A
,----EDGE OF ROOF
FlY- THIRD COURSE
rA
�61 -
2 SECOND COURSE
FIRST COURSE
NOA No.: 16-0425.01
MIAMI-DADE COUNTY Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 4 of 6
to
O O �
01
zaa
opo
� Wd
A
O A
F
F
A �
® O SureNail Fastening area
Z Area de fijacion SureNail
� � O
q Fastening area
Area de fijacion
Fastening area for
A AF7777771 Mansard or Steep Slope
p! Area de fijacion para mansardas
O o pendientes agudas
rn -
z
00
U
W
u
w .
8 NO p,a 'Fn
.a quema do 6 cove
Area do cb Vas
s
Ns
5 V �Itme M ssd # Expcase
5 xpasa l 5 M"de p#sl:ian
MAXIMUM SLOPE 21:12
Easteling for Slopes GTeaterlfian'21.12
SureNaN fastenin 9 zrea width
Naito lypicil
72., 12"
l7xrn3ai�[r]�Svr4+'�t.' !;`: 'lRtianGsa�sump ,l-oaeminuSuretvL] ' l.-
3 ;
6�1l8" $-518"
.. ,.
Faur 1"SpotsofAspFialt Roofing Cemnnt;
SLOPE GREATER THAN 21:12
END OF THIS ACCEPTANCE
NOA No.: 16-0425.01
CM11AMM�ADECOUONTY Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 6 of 6
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorization#9503
TRINITY i ER® 353 CHRISTIANOXFORD,,UNIT#13
CT 6478
(203)262-9245
EVALUATION REPORT
TRI-BUILT Materials Group,LLC Evaluation Report A42960.10.12-116
PO Box 70 FL16048-R6
Rutherford,NJ 07070 Date of Issuance:10/25/2012
(800)516-1485 Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by: .a""'►T;'z,,,~'
�ia :�Ko•aata9 :�:
Robert J.M.Nieminen,P.E. '.� �;� �'
',s$�,. X44`'�,
.,,j,� ��t,s•` The facsimile seal appearing was authorized hVRobert Nieminen,
Florida Registration No.59166,Florida DCAANE1983 F.E.on 09/25/2017.This does not serve asaneleUronlwlNsigned
document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD Is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
� l-RINI ER®
ROOFING COMPONENT EVALUATION:
1. SCOPE: .
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 6`h Edition(2017)Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/
Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1504.6 Accelerated Weathering ASTM G155 2005
1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
gntfty Examination Reference Date
ERD(TST6049) Physical Properties 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties S40540.11.13 11/19/2013
ERD(TST6049) Physical Properties 540540.03.14 03/26/2014
ERD(TST6049) Physical Properties S44870.04.14-2 04/02/2014
ERD(TST6049) Physical Properties 544870.04.14-3 04/02/2014
ERD(TST6049) Physical Properties 544870.04.14-1 04/10/2014
ERD(TST6049) Physical Properties 544870.04.14-4 04/10/2014
ERD(TST6049) Physical Properties 543530.02.14-1-R1 05/14/2014
ERD(TST6049) Physical Properties 543530.05.14 05/28/2014
ERD(TST6049) Physical Properties 540540.10.14 10/31/2014
ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015
ERD(TST6049) Wind Resistance SC14045.05.17-R1 06/07/2017
UL,LLC.(QUA9625) Quality Control Multiple-Listing R16814 12/10/2015
UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970.
4.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced,SBS modified
bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012.
4.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering, glass-mat reinforced, film-surfaced, SBS
modified bitumen roof underlayment;meets ASTM D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report A42960.10.12-116
Certificate of Authorization#9503 CH EDITION(2017)FBC NON-HVHZ EVALUATION F1.16048-116
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017
Page 2 of 6
�I
' TRINITY ER®
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
TABLE']:'ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes Slate
Shingles &Shingles
Tri-Built Sand-R SA Shingle Yes No No No Yes Yes
Underlayment
Tri-Built S/A HT TU Yes Yes Yes Yes Yes Yes
Underlayment See 5.5.1
Tri-Built Smooth HT S/A Yes No No Yes Yes Yes
Underlayment
5.5.1 "Foam-On Tile"is limited to use of the following Approved the adhesives/underlayment combinations.
TABLE 1AC:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT:COMBINATIONS
Adhesive Florida Product Approval Underlayments
ICP Adhesives Polyset®AH-160 FL6332 Tri-Built S/A HT TU Underlayment
Dow TileBondTl FL22525 Tri-Built S/A HT TU Underlayment
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB;Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT Materials Group,LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue-and-groove board decking be covered with plywood or
OSB prior to installation of the self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474,Appendix D or TAS 114,Appendix J.
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R6
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/2S/2017
Page 3 of 6
t '
TRINrry.ERD
5.6.3 Bond to Mechanically Attached Base Laver:
Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226,Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04-
12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck
underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile
applications: Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to,1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or
FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Soprema Elastocol 600c
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
#3 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self-adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end-laps.
#4 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R6
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017
Page 4 of 6
TRINITY I ER®
5.6.4.1 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012(0412),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)1:
When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIREcr-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum
Slope
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack
shall be inverted,followed by 8 tiles high 6:12
on slope,as shown below)
Tri-Built S/A HT TU
Underlayment
Lugged
,F>
Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017
Page 5 of 6
IN0T i ER®
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile applications:
While priming is optional,TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll,broom or hand-press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below,sealed in accordance with
TRI-BUILT Materials Group,LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back-nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Tri-Built S/A HT TU Underlayment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam-on the applications,reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Gulfport,MS
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-