Loading...
HomeMy WebLinkAboutNotice of Acceptance MIAMI-�ADE MIAMI-DADE COUNTY a PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.Qov/economy CGI Windows an oors,Inc. 10100 NW 25th Street Miami FL 33172 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade-County)and/or the AHJ (in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Buil-ding Code including the High Velocity Hurricane Zone. DESCRIPTION: Series"Sentinel 130" Aluminum Fixed Window-L.M.I. APPROVAL DOCUMENT: Drawing No. W10-02, titled "Series Sentinel 130 Alum Fixed Window (L.M.I.) (S.M.I.)", sheets 1, 1.1, 2, 3, 4, 5 and 6 of 6, dated 01/30/10, with revision G dated 08/29/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami—Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration,date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 15-0413.03 and consists of this page 1 and evidence pages E-1,E-2 and E-3,as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. NOA No.17-0918.07 MIAMI DALTe COUNTY Expiration Date: September 22,2020 Approval Date: November 22,2017 (/ Page I i CGI Windows and Doors,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTEDUNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NDA No.10-0510.13) 2. Drawing No. W10-02,titled Series Sentinel 130 Alum Fixed Window(L.M.I.) (S.M.I.), sheets 1, 1.1, 2, 3, 4, 5 and 6 of 6, dated 01/30/10, with revision F, dated 04/10/15,prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3).Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of a series 7500 PVC fixed . window, to qualify DuPont "Butacite" PVB interlayer, DurasealO and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel,P.E. 2. Test reports on: 1)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2)Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a series 7400 PVC project out window, to qualify DuPont "Butacite" PVB interlayer, DurasealO and Super Spacer(V insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel,P.E. 3. Test reports on: 1)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2)Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of a series 238 aluminum fixed window, to qualify DuPont `Butacite" PVB interlayer, DurasealO and Super Spacer@ insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel,P.E. 4. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 3)Water Resistance Test,per FBC, TAS 202-94 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a Sentinel 130 aluminum fixed window,prepared by Hurricane Test Laboratory, LLC, Test Report No. HTL-0080-0103-10, dated 03/30/10, signed and sealed by Vinu J.Abram, F.E. (Submitted tinder NDA No.10-0510.13) anuelez P.E. Product Contr Est iner NOA No. 7- 18.07 Expiration Date: September 22,2020 Approval Date: November 22,2017 E-1 CGI Windows and Doors,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-51h Edition (2014), dated July 18, 2014, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad,P.E. (Submitted under NOA No.14-0731.05) 2. Glazing complies with ASTM E1300-09. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 11-0624.02 issued to E.I. DuPont DeNemours & Co., Inc. for their"DuPont SentryGlas@ Interlayer"dated 08/25/11, expiring on 01/14/17. 2. Notice of Acceptance No. 13-0129.27 issued to E.I.DuPont DeNemours & Co.,Inc. for their"DuPont Butacite®PVB Interlayer" dated 04/11/13, expiring on 12/11/16. 3. Notice of Acceptance No. 14-0423.17 issued to Eastman Chemical Company(MA) for their"Saflex Clear and Color Glass Interlayers"dated 0619/14, expiring on 05/21/16, 4. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company(MA) for their"Saflex CP- Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 06/19/14, expiring on 12/11/18. F. STATEMENTS 1. Statement letter of conformance, complying with FBC-5th Edition (2014), and of no financial interest, dated July 18, 2014, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.14-0 731.05) 2. Laboratory compliance letter for Test Report No. HTL-0080-0103-10, issued by Hurricane Test Laboratory, LLC, dated March 30, 2010, signed and sealed by Vinu J. Abraham, P.E. (Submitted ufzder NOA No.10-0510.13) 3. Testing Proposal issued by the Product Control Section, dated 12/16/14, signed by Jaime Gascon, P.E., Supervisor,Product Control Section G. OTHERS 1. Notice of Acceptance No. 14-0731.05, issued to CGI Windows & Doors, for their Series "Sentinel 130" Aluminum Fixed Window — L.M.I. approved on 10/16/14 and expiring on 09/22/15. Manuel erez Product Control Ex*in r NOA No. 17-09W.07 Expiration Date: September 22,2020 Approval Date: November 22,2017 E-2 CGI Windows and Doors,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. W10-02,titled Series Sentinel 130 Alum Fixed Window(L.M.1.) (S.M.I.), sheets 1, 1.1,2, 3, 4, 5 and 6 of 6, dated 01/30/10, with revision G, dated 08/29/17,prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS I. None. C. CALCULATIONS 1. Anchor verification calculations and structural an ysis, -complying with Edition (2017), dated July 15, 2017, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies with ASTM E1300-09. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas© (Clear and White) Glass Interlayers" dated 06/25/15, expiring on 07/04/18. 2. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Interlayers" dated 01/19/17, expiring on 07/08/19. 3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company(MA) for their"Saflex CP—Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/17, expiring on 12/11/18. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, of complying with FBC 511 Edition (2014), with FBC 61 Edition (2017) and of no financial 'interest, dated August 15, 2017, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. G. OTHERS I. Notice of Acceptance No. 15-0413.03, issued to CGI Windows & Doors, for their Series "Sentinel 130" Aluminum Fixed Window — .M.1. approved on 6/25/15 and expiring on 09/22/20. Manuel P e ,P.E. Product Control miner NOA No. 17-0918.07 Expiration Date: September 22,2020 Approval Date: November 22,2017 E-3 49' 48" 49' f 1 0 FLANGE WIDTH BUCK WIDTH FLANGE WIDTH {� N S o D. YPICAL ELEVATION OPG. D.L OPG. D.L.D. OPG. 1 to 15o 6"MAX. 18'MAX. N d5 Ia. 'L '+ HEAD/SILL A 3 SHORTER '$ e4� c �e• p e m CORNERS SIDES m U C y °j STb mw ANCHOR SPACING SHOWN HEREIN APPLICABLE, FLANGE AND FLUSH FRAMES. - Q 2 ?n SEE SHEET 1.1 FOR FIN FRAMES. o c.....o Od I II IIz R a `o' 11 It V'c u u D N n u u C1 N B N 11 u C�rQ C u n u n u u OD.13 D.13 JL_____11____ ___JL_____1L___ -__ IL_____1L___ 96" p dJ t'j K ---t------rr--- ----r------rr--- --=n------m--- C3 II R II H BUCK HUGHT M Z O N 11 / 0 u / u II �, a Qwy4l fe o ii �' ii it �' it � ii �� If D.L OPG. li 3a�, = Oa I I 11 w a II II = a II �� II w u� J 00 J n o _-__JL------�_JL____ ,Q Ei O _-__JL__ _JL _ o _-__JL__•�_AL____ i9 Z O- o w -- "Ir------fl----- o d II II II II o o II I I J CG• ! II II m II 11 II I I S` LL II II If II II IN-E ---- it II e: II II FS` .1j------ rn ___ L______LL____ uw ___ L______LL____ m N !I II LLIIit==_= ___- ----- rr — 11 11 II II II II O a II II ,r----11 11 0 � II II II II II II m O II II IIS II II z ` N ,T I� iI II II li m o ____ ====Tr=-� =___ _ fa O ,I-1+11 LA J cN ¢ O=No FALSE MUNTINS RFACE APPLIED) 18' MAX. 6'MAX. IS- D PTIONAL 8'OPTIONAL SHORTER HEAD/SILL SHORTER FLANGE & FLANGE ADAPTOR FRAME SIDES CORNERS SIDES DAYLTTE OPENINGS: SIDES E C Z EQUAL LEG FRAME D.L.O. HEIGHT= BUCK HEIGHT- 3.00" ^ o.n SERIES 130 SENTINEL ALUMINUM FIXED WINDOW D.L.O. WIDTH = BUCK WIDTH - 3.00" o DESIGN LOAD RATINGS FOR THESE,WINDOWS TO BE AS PER F�W.WIDTH rn U•-� CHARTS SHOWN ON SHEET 2. WINDOW WIDTH WINDOW WIDTH`' WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH I I APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF FIX./FIX. OR FIX.WOW. WITH OTHER MIAMI-DADE COUNTY I I I I I I w m APPROVED WINDOWS USING MIAMI-DADE COUNTY APPROVED MULLIONS v y IN BETWEEN. z I I f I j z j I I 3 i m. a LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVALc ^S WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE L WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH m o o c REQUIREMENTS OF THE 2014(STH EDITION)/2017 (6TH EDITION) FLORIDA W WIDTH LAM. GLASS 1 CLUDING HIGH VELOCITY HURRICANE ZONE HVHZ. MPA 1BY OR 2BY WOOD BUCKS&BUCK FASTENERS BY OTHERS, MUST BE _ _ r 1 INSULATING LAM DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS � r � s r— -1 I I LARGE MISSILE IMPACC T- TO THE BUILDING STRUCTUREo z SMALL MISSILE IMPACT m _ -ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS % z �i % � � �AND m� MATERIAL SHALL BE BEYONDPER MATERIAL DRESSING ORESTUCCO.EMBEDMENT TO BASE A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY.W7n 7 z G_7 S F+ `�� IA•'•• ID 2Ct! : ��' GENSe b •I ALL SHINS TO BE HIGH IMPACT, NON-METAC AND NON-COMPRESSIBLE � L J i MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS,TW.T o.7 COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE THESE WINDOWS ARE RATED FOR LARGE&SMALL MISSILE IMPACT. PRODUCT REVISED _ _ .. 3• REQUIREMENTS OF THE 2014/2017 FLORIDA BLDG. CODE&ADOPTED STANDARDS. SHUTTERS ARE NOT REQUIRED. as complying with the Florida Building Code •® �` a , v THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION NOA-No. 17-0918.07 = W. FORA SITE SPECIFIC-PROJECT,.i.e. LIFE SAFETY OF-THIS PRODUCT,ADEQUACY _ :®••. ATE OF _•6{�� drawing no._ OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR - ALLOWABLE LOADS FOR ALTERNATE SHAPES AS SHOWN ABOVE OR =R:ECTA:NG Explration Data 09 2020 WATER INFILTRATION RESISTANCE ETC, VERIFIED BY INSCRIBING PICTURE WINDOW SHAPE WITHIN SQUARE OiS ••... , �� W10-OZCONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, SHOWN IN DOTTED LINES AND OBTAINING ALLOWABLE LOADS FROM Mlam xv ade Product Con r I AND TO BE REVIEWED BY BUILDING OFFICIAL i • i 96' BUCK HEIGHT D.L.OPG. 8 x z�+ • �F I' I II 11 II II I I� II II I I I I It o c r0 I� II II II \\ II II � � • II 11 li it it 76'MAX. 6'MAX. STRAIGHT JAMB SIDES 96' CORNERS rn BUCK HEIGHT Dl- OPG. F, I u I I 1� TILL �I I II II II II II o c 17- a x c' 16°MAX. 6'MAX. STRAIGHT JAMB Ell F SIDES CORNERS � 96' BUCK HEIGHT D.L. OPG. u b r JlI it II 111 II it 11��\\ II j1 0t II II II II 11 � O • ii it 2 O O 3•m �1 Z s vi 9 18'MAX. 6'MA)4 lu + a a1.11 O 1n. AB' STRAIGHT JAMB c' C m g m BUCK HEIGHT SIDES CORNERS a n'e f) y= D.L. OPG. 9 d m"'I C ~ JC O n m a 13 b stn �' °0 OO zI I ``11 IIIIIIA7j11 p Z ❑ II 11 i ;o z .r �oV yi8=, n icy` In ila�N9r �� II� I� O�• 4 n s a date: D7_�o 1D revisions: SERIES SENTINEL 130 ALUM FIXED WINDOW(LM.I.)(S.M.I.) AL-FAROOQ CORPORATION a O n0 0 B BDcri on e<ole: 1�2•+1• c o220.i1 NO cHANOE 7Hs SHEET ENGINEERS&PRODUCT DEVELOPMENT f CGI Windows and Doors, Inc. f O 10.10.17 NO CHANCE 1N6 SHEET 9380 SUNSET DRIVE,SUITE 220 07.27.14 UPOATE070 2014 FHC 10100 N.W. 25TH STREET MIAMI,FLORIDA 93173 (C-4.N.9688) /� Q F 04.10.15 NO CYANDE THIS SHEET MIAMI, FL. 33172 TEL(3OS)2648100 FAX(305)262-.976 V 0) TV chk by: 0 00.29,17 UPDATm 70 2017 FBC I TEL(305)593-6590 FAX (305)593-6592 COMP-ANL\W70-02CG1 DESIGN LOAD CAPACITY-PSP DESIGN LOAD CAPACITY-PSF W U FLANGE DW. BUCK DW. IGIASS TYPES'C'&'Cl'GLASS TYPES'D'&'DI' FLANGE DUBS. BUCK DIMS. GLASS TYPES'C'&'CI'GLASS TYPES'D'&'Dl' WIDTH(W)LENGTH(L) WIDTH(W)LENGTH(L) EKT.(+) INT.(-) EXT.(+) 1NT.(-) WIDTH(W)LENGTH(L) WIDTH(W)LENGTH(L) EXT.(+) 1NT.(-) M.(+) INT.(-) 24• 23' 80.0 80.0 80.0 80.0 24' 23• 80.0 BO.0 60.0 80.0 Z m �+ 30• 29' 80.0 80.0 80.0 8D.0 J0' 114, 29' 113, 80.0 80.0 80.0 80.0 L O b m 36• 35• 80.0 80.0 80.0 80.0 36' 35' 73.0 73.0 80.0 80.0 (• ; al 42• 36. 41' 35, 60.0 80.0 BO.D 80.0 416 40' 61.4 61.4 80.0 80.0 48' 47• 80.0 80.0 80.0 80.0 24' 23' 60.0 80.0 80.0 80.0 54' 1' 80.0 80.0 80.0 80.0 30' 120, 29' 119, 80.0 BO.O 8D.0 80.0 60' 59' 80.0 80.0 80.0 80.0 36' 35' 724 72.4 BD.O 80.0 �•O _ 7 61' 1 1 60' 80.0 80.0 80.0 80.0 39 38' 65.9 65.9 80.0 80.0W no 24' 23• 80.0 80.0 80.0 80.0 24' 23' 60.0 80.0 80.0 80.0 AND LENGTH DIMENSIONS CAN BE ORIENTED a K o 30' 29• 00.0 80.0 80.0 80.0 JO' 121, 29' 120, 87.0 80.0 80.0 80.0 MUM VERTICALLY OR HORIZONTALLY AS SHOWN ABOVE O IL CF. A 36' 35' 60.0 80.0 80.0 80.0 36' 35' 72.3 72.3 80.0 80.0 Q W 5 42• �. 41' 47' 70.2 70.2 80.0 80.0 39' 35' 65.8 65.8 80.0 SOA W z�a 48• 47• 61.3 61.3 80.0 80.0 1LL Z O 54' 53' 61.361.3 BO.0 80.0 k+'TYP. BUCK DIMS 2 t0 60' S9' 61.3 61.3 80.0 80.0 �1 Q W 01 f 61• 60' 61.3 61.3 80.0 80.0 DESIGN LOAD CAPACITY-PSB 24' 23' 80.0 80.0 80.0 80.0 FLANGE DIMS. BUCK DIMS. GLASS TYPES'C'&'CS'GLASS TYPES'D'&'01' FLANGE FRAME 30• 29• 80.0 80.0 80.0 80.0 WIDTH(W)LENGTH(L) WIDTH(W) LENGTH(L) EXT.(+) 1NT.(-) EXT.(+) 1NT.(-) a N 36' 35' 80.0 80.0 80.0 BOA 19-1/8, 18-1/8' 80.0 80.0 �- FLANGE DIMS- i U I 42' �. 41' 59' 70.2 70.2 80.0 80.0 26-1/2' 25-1/2' 80.0 80.0 80.0 80.0 48' 47' 61.3 61.3 80.0 80.0 37' 26 36' 25, 80.0 80.0 80.0 80.0 BUCK DIMS o - n 54' 53• 54.3 54.3 72.5 72:5 47• 87.0 80.0 80.0 80.0 3 O 60' 59' 48.8 48.8 65.1 65.1 53-1/8' 52-1/8• 80.0 60.0 60.0 80.0 O 61' 60' 48.8 48.8 65.1 65.1 61• 60' 80.0 80.0 80.0 80.0 24' 23' 80.0 80.0 80.0 80A 19-1/8' 18-1/8' 80.0 1 80.0 8D.0 80.0 C(~11 3D• 29' 80.0 80.0 80.0 80.0 26-1/2• 25-1/2' BOA EGUAL LEG FRAME 80.0 80.0 BD.O F 36' 35' 80.0 80.0 80.0 80.0 37' 36' 80.0 80.0 80.0 80.0 = 38-3/8' 37-3/8' BUCK DIMS C4 M 42• 72. 41' 71• 702 70.2 80.0 80.0 q8' 47' 77.1 77.1 80.0 80.0 '� 00 M 48' 47' 61.3 61.3 80.0 80.0 53-1/8• 52-1/8' 77.1 77.1 80.0 80.0, z 54' 53' 54.3 54.3 72.5 725 61' 60' 77.1 77.1 80.0 80.0 3 0 60' 59' 48.8 48.8 65.1 65.1 19-1/6' 18-1/8• 80.0 80.0 80.0 80.0 61' 60' 48.0 48.D 64.0 64.0 26-1/2• 25-1/2' 00.0 80.0 80.0 80.0 FIN FRAME U 24' 23' 80.0 80.0 80.0 80.0 37' 50-5/8' 36• 00.0 80.0 80.0 80.0 30' 29' 80.0 80.0 80.0 80.0 48' 47' 61.3 61.3 80.0 80.0 49-5/B' BUCK DIMS 36' 35' 78.2 78.2 Bo.o 80.0 53-1/B• 52-1/B' 58.0 58.0 77.4 77.4 42' 84. 41• 1. 70.0 70.0 8D.0. 80.0 61 60• 58.0 58.0 77.4 77.4 4e' 1• 613 61.3 80.0 80.0 75-1/4' 74-1/4• 58.0 58.0 77.4 77.4 FLANGE ADAPTOR FRAME 0 =y= 54' S}' 54.3 54.3 725 725 93-3/4• 92-3/4' 58.0 58.0 76.5 76.5 p§ $ n 56' S5' 52.4 524 69.8 W.8 19-1/8' 18-1/8' 80.0 80.0 80.0 80.0 ,� 12'�1'- I FLANGE DIMS I 3 24• 23' 80.0 80.0 80.0 80.0' 26-1/2' 25-1/2' 80.0 80.0 80.0 80.0 h 3 8 30• 29' 80.0 80.0 80.0 80.0 37' 36' 80.0 80.0 80.0 80.0 pr g i g 63' 62' NOTE: 36' 35' 75.6 75.6 80.0 80.0 4B' 47' 613 61.3 80.0 80.0 s7' 96' GLASS CAPACITIES ON THIS SHEET"ARE 42' 41' 65.2 652 80.0 80.0 53-1/8' 52-1/8• 553 55.3 73.7 73.7 BASED ON ASTM E1300-09 (3 SEC. GUSTS) 49' 47' 60.6 60.6 80.0 BDA 61' 60' 48.0 45.0 64.0 64.0 AND FLORIDA BUILDING COMMISSION o 49' 48' 59.6 59.6 80.0 BDA 75-1/4' 74-1/4' 46.5 46.5 61.9 61.9 DECLARATORY STATEMENT DCA05-DEC-219 o o S 24' 23• 80.0 B0.0 00.0 80.0 19-1/8' 18-1/8' 80.0 80.0 80.0 80.01\1j1HM lrrrrr m ocu c 30• 29' 00.0 60.0 80.0 80.0 26-1/2• 25-1/2' 80.0 90.0 80.0 80.0 3,6' 102' M. 74 76' 75'74.6 80.0 00.0 37• }6• 78.9 78.9 00.0 80.0 C '1 ?1i.L '. JGENSF"•;'ZJ a •� 42• 41• 65.7 65.7 80.0 80.0 4B' 47' 61.3 61.3 80.0 80.0 46• 45' 59.3 59.3 B0.0 80.0 53-1/8' 52-1/8' 55.3 55.3 73.7 73.7 PRODUCT REVISED .70582 c 24' 23' 80.0 80.0 80.0 80.0 61' 60' 48.0 48.0 64.0 64.0 as complying with the Florida Building Code 30' 29' 80.0 80.0 00.0 6.7.0 NOA-Io. 17-0918.07 36' 108' 35' 107' _ 73.8 73.8 80.0 BD.O TATE OF 7a(/-� drawing no. -- ---- ANCHOR SPACING TO BE AS PER SHEEfS 1 & 1.1 Ex Iratl n Date 091 020 �' ` W 1 0-02 42' - - 41' 62.4 62.4 80.0 00.0 44' 43• 59.1 59.1 80.0 80.0 Mia-' ade roduct ntr r71111111A11 sheet 2 of 6 3/16-ANN.GLASS 3/16'HEAT STREN'D GLASS �r i V 0' 075'InieAoyer 075'Interlayer o Saflox CP With PEr Coro Saflex CP With PET Care A of By'Eastman Chemical Co.' R'Eastman Chemical Co.' m # Z y 090'Interlayer .090'Interlayer y of Saflex Clear And Color Glass Saflex Clear And Color Glass FF ^+W OR•Eastman Chemical Co.' By'Eastman Chemical Co.' W OR h E ? .090'Interlayer .0900 Interlayer 0 O`,0 v SeMryGias Sen las tqV By Kumray America. Inc.' By'Kuraray America, Inc.' _ IL q OR OR p 090' Interlayer 090'InterlayerTrosifol ui' By kura�America, Inc.' By Nurarray America, Inc.' ��g 3/16'HEAT STREN'D GLASS Ll "HEAT STREN'D GLASS 0 a•D p g m yy m O N N C SILICONE ! 51000NE Q Cr z w D 5 .I 7 .I N_ o a t Ij I GE 1200 < m 1 IjGE 1200 LL Z o 8 II li DOW CORNING 899 n E3 it DOW CORNING 899 a w DOW CORNING 995 DOW CORNING 995 Z jl jl jj I�I� 0 O y N r. MS AT WIDER POINTS�N UTES F M5 AT 1/4 POINTS ON LITFS 3 C n SWG x WIDER THAN 36' o 51 GLASS TYPE 'C' GLASS TYPE 'D' �. 7/16.OVERALL LAM.GLASS 7/16.OVERALL LAM.GLASS 8 0 Li (L.M.I. & S.M.I,) o w 3/16'ANN.GLASS 3/16'HEAT STREN'D GLASS C 02ND .075'Interlayer .075'Interlayer m N�m Set CP With PEI Core Saflex CP With PET Core n 3 N M I OBy R,Eastman Chemical Co.' By'Eastman Chemical Co.' Li ,00 M a OR C Z .090'Interlayer .090'Interlayer � Saflex Clecr And Color Class Saflox Clear kid Color Glass o - 'Eastman Chemical Co.' SIUCONE o_ �' By'Eastman Chemical Co: F w 0 GE 1200 ^Q" 3/8'AIR SPACE OR 3/8'AIR SPACE OR F>= O 090'Interlayer 090'Interlayer = m DOW CORNING 899 N U Sentgolos Santry I g rn 1 I��I DOW CORNING 995 3/16'HEAT STREN'D GLASS By 'Kuroroy/vnerlco, Inc.' By Kumroy America, Inc.' [�;7 OR OR 090'fnterlayer 3/16'NEAT S1REN'D GLASS 090'Interlayer Trosifol PVi3 Trosifol PJB By'k mmy America,Inc.' By'kummy America, Inc' M4 j! it it His 3/16'HEAT STREN'D GLASS 3/16'HEAT SIREN-0 GLASS o a a o: S1000NE W o 12 SILICONE SILICONE GE 1200 v 6 a rn I'I DOW CORNING 899 ca i'I DOW CORNING 899 m= z = GE 1200 i j. DOW CORNING 899 DOW CORNING 995 g LI:I DOW CORNING 995 II:I DOW CORNING 995 Mt ij ij!j \ M1 ii ij r OPTIONAL GLAZING DEVIL, n it jl Il n II II II 1!2 t: XL EDGE SPACER XL EDGE SPACER GLASS TYPES 'Cl' & '1)1'RDInon jl jl jl 1! i!i! ST.STEEL BY'CANAL' 'I ST. STEEL.BY'CARDINAL' 8 6 S S E5 OR E4 ii i OR PA > DURASL BY'OUANEX' i' DURASFAL BY'OUANES(' `tlll tl 1111/lyy �S o o W ILL o I OR OR p SUPER SPACER BY'OUANIX' p SUPER SPACER BY'Ol1ANIX ��t' `�� .. •- W..:....- kMS AT 1/4 PO NTS ALL 512E5 F M5 AT 1/4 PO NTS ALL SIZES PRODUCT REVISED �.F C-LASS TYPE 'Gl' as complying with the FloridaGLASS TYPE 'DI' 6utiding Codet'OVERALL INSUL LAM.GIJSS1'OVERALL WSUL LAM.GLASSNOA-No. 17-0918.07 0(L-M.I. ONLY) iretl n Date 09/22/2020 (y` (drowmgg no. -- IEXTERI R PER LY OF ILASFY STYPE DC7 MdcS'D7'LE IMUST BEMPACT ¶TEMPERED. Miami ode roduct o t 1 'NG PTIT44 / s�/I `` ls—he�eto3 of 6 1 TYPICAL INSTALLATION DETAILS V THESE DETAILS ARE TYPICAL ON ALL FOUR SIDES OF WINDOW �� A INSTALLATION DETAILS THRU IX INSTALLATION DETAILS THRU 2X INSTALLATION DETAILS INSTALLATION DETAILS INTO METAL z m WOOD BUCKS INTO CONCRETE BUCKS OR INTO WOOD STRUCTURES DIRECTLY INTO CONCRETE STRUCTURES OR INTO APPROVED MULLIONS H °j FLANGE FLANGE TYPICAL ANCHORS FLANGE 1/4•MAX. FLANGE a s GSEE o 26Y WOOD BUCK FOR SP ELEV. SHIMS 0 Do�U" O ji II OR METAL a {{cuVu ,,alt jl jl WOOD STRUCIUR TYPICAL ANCHORS STRUCTURE O:0 t W E3 SEE ELEV. I!I FOR SPACING 0 0 N h I I a.v M2 TYPICAL ANCHORS V I j I I SEE ELEV. 0-914 2p S2• = O I v H © FOR SPACING d 0 0.S m o e w \ 0' ep 0 I v NNO m Et ILz°i- m' " � S2 MIN. °• -- - z a WOIE ,•v o' 'TYPICAL ANCHORS �j ji L12 a w I SEE M". FOR SPACING II II WOOD BUCK v _j U S — � SHIMS 00 Li EQUAL LEG EQUAL LEG EQUAL LEG v EQUAL LEG LL d 29Y WOOD BUCK Mz METAL J ctn � B 1 A l woOD STRUCTURE C 1 srRUCTURE 3 O=n E3 .I TYPICAL ANCHORS N LO SEE ELEV. ,Mj n II!I 1 ,v y a FOR SPACING Ed ,O 3 n MJ O D 9 8i c) M3 (X7YPI�C�A�LANCIHORS EV, x FOR SPACING'TYPICAL A&CHORS ISEE ELEV,' ANCFK)RSFOR SPACING V. o9 1n WOOD BUCK CING u12.2 PRODUCT REVISED BE k9 8 as complyingwith the Florida d Building Coe z g NOA-No. 17-0918.07 WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WDW. E.pi.tion Date 09MV2020 MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM _ TYPICAL ANCHORS: SEE ELEV.FOR SPACING AND TRANSFER THEM TO THE BUILDING STRUCTURE. o n- o m 4' I ON I ' (F-163 KSI,Fy=157 KSI) MlamhDa Produc Con I By a Ory9&_,. 111111! 1/4' DIA. ULTRACON BY'ELCO' Fu=177 KSI.Fy=155 KSI) 914 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES INTO MAMI-DADS COUNTY APPROVED MULLIONS A/o o 1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS) OR INTO CONCRETE AND MASONRY = 2-1/2" MIN. EN �� b INTO METAL STRUCTURES (HEAD/SILL/JAMBS) INTO WOOD STRUCTURE = 7" MIN. THRU 1BY BUCKS INTO CONC. OR BLOCKS INTO METAL STRUCTURE = 3/4" MIN. _ o (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE 1-1/4' MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) ALUMINUM: 1/6°THK. MIN. (6063-TS MIN.) WOOD AT HEAD, SILL OR JAMBS SG- 0.55 MIN. STEEL• 1/6" 1-1/4' MIN. EMBED INTO BLOCKS (JAMBS) THK. MIN. (Fy = 36 KSI MIN.) CONCRETE AT HEAD, SILL OR JAMBS f'c =3000 PSI MW. - v = 7E drawin no. ._DIRECTLY INTO CONCRETE.OR-BLOCKS__ _ (STEEL C-90 HOLLOW/FlLLED IN CONTACT WITH ALUMINUM TO BE PLATED OR-PAINTED) -BLOCK AT JAMBS Pm 2000 PSI MIN. OF �� 9 - ---- 1-1/4' MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) '%�'• OR1OP`,•' C�.` 1-1/4' MIN. EMBED INTO BLOCKS (JAMBS) �i��S --•. G_� W10_02 7/YI�RI•YYY��`` sheetoof 6 i i TYPICAL INSTALLATION DETAILS V THESE DETAILS ARE TYPICAL ON ALL FOUR SIDES OF WINDOW �Cy" o 0 Z m^ 3 b p J INSTALLATION DETAILS THRU 1X INSTALLATION DETAILS THRU 2X INSTALLATION DETAILSINSTALLATION DETAILS INTO METAL F m WOOD BUCKS INTO CONCRETE BUCKS OR INTO'WOOD STRUCTURES DIRECTLY INTO CONCRETE STRUCTURES OR INTO APPROVED MUWONSQE ;'a'FLANGE ADAPTOR FLANGE ADAPTOR FLANGE ADAPTOR FLANGE ADAPTOR a U TYPICAL ANCHORSSEE ELEV. 1/4'MAX O G SHIMS m 2BY WOOD BUCK R SPACING V Do a m I�jj WOOOR D STRUCTURE TYPICAL ANCHORS METAL OD m g nElI 'I M2 SEE ELEV. STRUCTURE C 0.O 6 N O B3 II II FOR SPACING a v ''. M2 TYPICAL ANCHORS Q m SEE ELEV. �m 0 m O .I S2 s I a H FOR SPACING IQWj li a W N,:o % g E2 1 Efi U N 0 Li12- ES r, 52 MIN. • .. ... II II c �i � . D r •TYPICAL WCHORS M2 U .. ^. I SEE ELEV. d C "> 1BY FOR SPACING 'I 'I \ 3 — a - WOOD BUCK II !I ? c •v >. ES F2 E3 3 O E) 0 til 2 3/8-MIN. 1//44-,,,MAX ---((( BUCK HEIGHT 1/4"MAX. LL GAP WOOD STRUCTURE N o NOT BY CGI 1/2"MIN. 1/2'MIN. n 3 N M m 22 3/ C2 v°3 M FIN FRAME M2 CKBED N c z o CAULKING 3 00 3 TYPICAL ANCHORS: SEE . FOR SPACINGBA nc v r 8 SMS (GRADE 2 CRS) 0". INTO 2BY WOOD BUCKS OR WOOD STRUCTURES WHEN USED THE MIN. WOOD 1-1/4° MIN. PENETRATION INTO WOOD BUCK DEPTH SHALL BE 2%". THE USE OF DEEPER'OR `n BEVELED WOODBUCKS IS o F A PERMITTED. HOODUSBE WRAP E5 E3 EXTERIOR K�F m°gig=S BUCK WIDTH BUCK WIDTH r_------------ _ MIAMI-DADE COUNTY I I MIAMI-DARE COUNTY APPROVED APPROVED MULLION I I MULLION&MULLION ANCHORS II o o I I 11 &MULLION ANCHORS I I SEF SEPARATE NCA 11 n o A e S i- SEE SEPARATE NOA I I 11 • Cr? '1 II ��y� ``�\,��149,�1111�131�1�11j1j, _•-_-_.:_:_-_—._-: 1 i i 1 _•-_—._.:_:_.-- PRODUCT REVISED N.7 A I I I as cram I In with the Florida y g M�F 11 I 1 Building Code 8 TYPICAL ANCHORS NOA-No. 17-0918.07 •� v a '� SEE ELEV- Expiration Date 09/22/2020 - -.- - - _- - - - FOR SPACING �®•• TE OF- �(T,; drawing no. -- -- - \ . 1 dux, SMS. Br ,t4 ��, w10-02 Nliam ade Produe ntr 1 til ���� V�� . ( 1j1111i1i1tY1� sheet 5 of 6 _ - I rFBM PART ttUANiL'rY DESCIUMON MATERIAL MANF./SUPPLMR/REMARKS Cr 1y 00I-118 4/WOW, FLANGE FRAME 6063-T6 - m E2 CGt-119 4/WOW. FLUSH FRAM FRAME 6063-Tfi - E3 CGI-121 4/WOW. GLAZING BEAD(IAM.GLASS) 6063-T6 Z 1.995 .812 E4 CGI-123 4/WOW. GLAZING BEAD(LAM.INSUL GLASS) 6063-T6 .995 065 E5 CGI-110 4f WDW. NAIL FIN ADAPTOR 6063-T6 _ ~Q 2 �� m TyP. E6 CGI-109 4/WOW. FRONT FLANGE ADAPTOR 6063 T6 MI CG1-382V AS REOO. GLAZING BULB VINYL PVC DUROMETER 75-80 SHORE A �O01 xx 1335- M2 CGI-124 AS READ. SCREW COVER-OPTIONAL PVO }D. LL M3 CGI-112 AS MD. FLUSH FRAME COVER PVC - 0 t N E7FRAME M4 - OPTIONAL GLAZING ANGLE(1 X 1/2 X 1/8' 6083-75 - v O aFLANGEE a 5 M5 - 2/LITE SEi DNC BLOCKS EPDM DUROMETER 85#5 SHORE A 0'a Q M Q 2.505 S2 #10 X 1-1/4' 2/CORNER ASSEMBLY SCREW PHL PH SMS ST/SL j YF.068 1.495 .512 4 O q�o .495 7YP, �t O FLUSH FRAME/FlN FRAME c a n .675 a50 .975 Q W .995 n.P, WELDED,POINT ? C 1�A 4 AT ENDS c 1naa� a 3N^m M O GLAZING BEAD (LAM. GLASS) M i o E5 2:z�' 99s osD t.000 --E-125 M4 Eq GLAZING BEAD (LAM. INSUL GLASS) GLAZING ANGLE (LAM. INSUL GLASS) CIRCULAR WINDOWS A E 2 1.130 .065 RECT. OR SQUARE WINDOWS i 1.450 1.550 1.6Bo `gyp G EnR D T$ AILS .550 ,050 ---m n a m a a oso o o 11.345-+i llllltitl 7t/1117 �c o' "o O NAIL FIN ADAPTER E6 FLANGE ADAPTOR 1.395 1.118 asRoDUCT mplyln88 REVISED thEForida 1Bo NOA-Nte. 17-0918aO7 291 .050 .050 Expiration Date 09/2212020 � TE Cc- .-A wing 1.OBi dm no. By Mlam ado ro u o t 111 n � ` sheat 6 at 6 M3 FLUSH FRAME COVER MZ SCREW COVER 6