Loading...
HomeMy WebLinkAboutProduct Approval (2) 06�r�, im k,-- I FLORIDA DOPAMMENT OF an e ' -go BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge Stats&Facts I Publications FBC Staff BCIS Site Map I Links Search Florida r Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail F FL10674-R13— Application.Type Revision Code Version 2017 Application Status Approved Comments Archived CD Product Manufacturer Fweas_Cornigg, Address/Phone/Email One Owens Coming Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscoming.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscomig.com Quality Assurance Representative Address/Phone/Email Catego oofin Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE759166 Quality Assurance Entity LIL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By. John W. Knezevich,PE Z Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen. ddff i Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code QC-`a_. :y Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R13 II 2017 10 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.0f Impact Resistant: N/A Verified By: Robert 1. M. Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER,Section 5. Evaluation Reports. FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT SHINGLES FL10674-R13.pd Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FI.32399 Phone:850-487-1824 The State of Florida is an WEED employer.C�yright 2D07-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapber 455,F.S.must provide the Department with an email address if they have . one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: iilr� ® EC Credit Card Safe'.- EXTERIOR RESEARCH&DESIGN,LLC. F)o Certificate ofAuthorization#9503 TRINITY I 353 CHRISTIAN STREET,UNIT#13 ERD OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-118 One Owens Corning Parkway FL10674-1113 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404-7829 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, .P.E. for,use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products; described herein have been evaluated for compliance with the 6ei Edition (2017) Florida Building Code sections'noted herein. DEs -RIP rloN: Owens Corning 149-6—ofiSfiffilgi-e7sli ngles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADvERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPEcnON:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by:. .».��, Robert J.M.Nieminen,P.E. �!•�� C1t1 a'`�t The facsimile s al 10/09/2017.appearings authorized idoes by Robert an Florida Registration No_59166,Florida DCA ANE1983Nieminen, electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinityI ERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. '\J TRINITY I ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: gnifty Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance IICA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asahalt Shinsles: 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 DevonshireTm are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration®, TruDefinition® Duration® Duration' Premium Cool, TruDefinition' Duration Designer Color Collection,TruDefinition®Oakridge Oakridge® and WeatherGuard HP are fiberglass reinforced, laminated asphalt roof shingles. 4:2 Hip&Ridge Shinsles: 4.2.1 Berkshire Hip& Ridge Shingles, High Ridge,WeatherGuard'HP Hip& Ridge Shingles, ProEdge Hip& Ridge Shingles and DuraRidgd'Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. . LIMITATIONS: 51 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,U.C. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Coming Asphalt Roof Shingles Revision S:30/09/2017 Page 2 of 8 TRINITY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (Vnit = 194 mph). Refer to Section 6 for installation 'requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the shingles are acceptable for use in all wind zones up to Va,d=150 mph(Vnn=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C,as defined in FBC 1609.4.3,and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1, Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire shingles require minimum five(5)nails per shingle. ➢ WeatherGuard HP shingles require minimum six(6)nails per shingle. ➢ Devonshire TN shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlayment Deck FeBunder"eat —Deck Self-adhered WenthedncirD Self-adhered undedaymem WeatherLocka underlayment Ddpedge Drip— Drip edge Drip— edge edge _ Nab krafed Nails located 2 rfromeave 2=3"from eave Install fnst Self-sealing adhesive Se1lcnalmg adhesive insWgrstStartersttipl9us ositionedabo eave Starter Stripp positioned along eave �S.�av� P 9 shingle with " \ ,. \ 9"removed Starter Strip shingle overhangs eaves and rakes'/i-'/P SlaswStnlpPlus ovMangseaves and rakes 1141-W Exterior Research and Design,U.C. Evaluation Report 037940.02.12-Rg Certificate ofAuthorizatfon#9503 6t"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 TRINITY I ERD 6.2.1 Minimum Nailing—TruDef(nition•Oa krifige°,Oakridge®: 4 Nail I'atfem 6 Nail Paint Espoina con 4 d'avos Esguema con 6stavos 1. 1• t• IE— z• — I Ni— 1r it 65/8"Exposure:, Na7s We"Exposure Expe duoa,desclopulg. Clavas Exposid6nde5Wpulg. 55/8"Exposule C/�avm 5618 Exposure Eirposld6nde 6,518 pulp Exposid6n de 5518purg. Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for slopes Greater Than 21:12 s,rewna rnum�ar.a.wth 1• 12" I I 1z" '- 0 Four 1"Spot ofAVh•It Roon.9 Cement Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuar&HP: ■ I $Ing a Ode Vkw FT ..�• ::�j• Fifdn.r7l..u�f IRiI liN CiwminJag, atif��die i J. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118 Certificate afAuthorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 ITRINITYIERb 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard Wind Direction Fastening Sealant Strip Pattern 6'Exposure �• I � �I I I«p 12° I fff Sealant Fasten 71h° Th' 6'Exposure Cover Exposed 1 j Fasteners with Roof Cement 6:i 3.6 Minimum Nailing—DuraRidgeTm Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Proxw"ing Wind Dirocdcn Top View DI olDnd.Rilllnllt"clijynt 1_ V6ees for I.I DirecdOndel viento pr�nimntu s Nai6�� P Dwcns Casing SMNaT • 41om t I ml« �+ J 4 J 7. LABELING: 7.1 Labeling'shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118 Certificate of Authorization#9503 EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8