Loading...
HomeMy WebLinkAboutProduct Approval - Mullions Florida Building Code Online Page 1 of 2 i . • k • r�'n f • 4 .V ��� e r o.L. ' � � SCIS Home I Log In User Registration j Hot Topics•I Submit Surcharge I Stats&Facts Publications I FSC Staff I SCIS Site Map I LMks I Search Product Approval 4 USER:Public User db' rPraOUQ Aooroval Menu>ProOuct or Aoolication Search AopliicatiQn List>Aplication Detail -, FL k FL9520-R7 - Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala,FL 34474 (352)368-6922 Ext 245 kpine@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala,FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative Arturo Monteverde Address/Phone/Email 1900 SW 44th Ave Ocala,FL 34474 (352)368-6922 Ext 221 amonteverde@cws.cc Category Windows Subcategory Mullions Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lucas A.Turner the Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M.Urich,PE 1✓ validation Checklist-Hardcopy Received Certificate of Independence FL9520 R7 COI EvalReoort836B.Ddf Referenced Standard and Year(of Standard) Standard YAM AAMA 450-10 2010 ASTM E1886-05 2005 ASTM E1996-09 2009 PA TAS 201/202/203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL9520 R7 Ecuiv FL9520 Eauivalencv.odf http://www.floridabuilding.org/pr/pi_app_dtl.aspx?param=wOEVXQWtDgvIHvmu.I R Wc... 12/14/2017 Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/29/2017 Date Validated 10/02/2017 Date Pending FBC Approval 10/05/2017 Date Approved 12/12/2017 Summary of Products L# Model,Number or Name Description 9520.1 3"Alum.Tube Mullion 3"Alum,Tube Mullion,Horizontal&Vertical,Fin&Flange applications.(IMPACT) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9520 R7 II CWS-8368.odf Approved for use outside HVHZ:Yes Verified By:Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Large Missile Impact;See Installation Instructions FL9520 R7 AE EvalReoort836B.odf and Evaluation Report for complete list of Limitations and Created by Independent Third Party:Yes Conditions of Use. 9520.2 4"Alum.Tube Mullion 4"Alum.Tube Mullion,Horizontal&Vertical,Fin&Flange applications.(IMPACT) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9520 R7 II CWS-837B.odf Approved for use outside HVHZ:Yes Verified By:Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Large Missile Impact;See Installation Instructions FL9520 R7 AE EvaIReDort8375.Ddf and Evaluation Report for complete list of Limitations and Created by Independent Third Party:Yes Conditions of Use. 9520.3 5 1/2"Alum.Tube Mullion 5 1/2"Alum.Tube Mullion,Horizontal&Vertical,Fin& Flange applications.(IMPACT) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9520 R7 II CWS-838B.Ddf Approved for use outside HVHZ:Yes Verified By:Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Large Missile Impact;See Installation Instructions FL9520 R7 AE EvaiReDOrt838B.Ddf and Evaluation Report for complete list of Limitations and Created by Independent Third Party:Yes Conditions of Use. Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.if you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here.. Product Approval Accepts: rr t� .l W kr_.. -«. Credit Card Safe http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvIHvmuJRWc... 12/14/2017 U1239�� 1.239 Jabara Ave. j� North Port,FL 34288 ENGINEERING & Ph. 941-380-1574 TCONSULTING,INC. FBPE C.O.A.#29779 Evaluation Report 836B September 26,2017 Product Description: PVC 3"Mullion H-1758 Manufacturer: Custom Window Systems,Inc. 1900 SW 44'b Ave,Ocala,FL 34474 Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005(4). This product complies with the requirements of the 6'h Edition(2017)Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report,prepared by Lucas A.Turner,P.E.,at 1239 Jabara Ave.,North Port,FL 2) Approval drawing CWS-836B,signed and sealed by Lucas A.Turner,P.E. 3) Test Reports NCTL-210-3833-1,-IA,-2,-2A,-3,and-3A,from National Certified Testing Laboratories,Orlando,FL signed and sealed by Gerard J.Ferrara,P.E. a. Testing Performed: TAS 201/202/203-94,ASTM E 1886-02/04/05,ASTM E 1996- 04/06/09,and AAMA 450-06 4) Supplemental Calcs.to support CWS-836B,signed and sealed by Lucas A.Turner, P.E. Installation: Units must be installed according to approval document CWS-836B. Limitations of Use: This product: • May be used up to the sizes and design pressures as shown in CWS-836B,using clips as shown in CWS-836B • Is Large Missile Impact Resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • May only be used with Custom Window System,Inc.windows,please see separate individual window unit approvals for applicable design pressures and for more details. The lower of the individual window design pressures and the mullion design pressures shall apply to the entire assembly. • Requires 6063-T6 aluminum mullion and clip extrusions. Certification of Independence: I do not have,nor do I intend to acquire,nor will l acquire,a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have,nor do I intend to acquire,nor will I acquire,a financial interest in any other entity involved in the testing or approval process of this product. �0 PrtORF W ,, r !i Lucas No 58201 9/26/2017 Turner : * * =*= Lucas A. Turner,P.E. 2017-09-28 srare of r w FL PE#58201 07:30+20:00 '•,0,�•. Al 0 R 1C3•.•G����� GENERAL NOTES: 311 PVC MULL BAR - LARGE MISSILE IMPACT 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH WINDIOIOW SMEMS SHOWN WDIFFERENT OPTIONS THE FLORIDA BUILDING CODE(FSC),CURRENT EDITION INCLUDING THE HIGH 19W SW 44TH AVE. VELOCITY HURRICANE ZONE(HVHZ)AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL OCALA FLORIDA 34474 D IMPACT USE AS DEFINED IN ASTM E 1998 PER THE FBC. W W W.CWS.CC 2.CONFIGURATIONS(SEE SHEETS 2-3):VERTICAL OR HORIZONTAL. 3.SEE MULLION CHARTS FOR MAX.DESIGN PRESSURES AND LENGTH. 3"PVC ® — (REFER TO SHEETS 2-3) MULL BAR 4.ANCHORAGE:THE 331/316 STRESS INCREASE HAS NOT BEEN USED IN THE IMPACT DESIGN OF THIS PRODUCT.SEE SHEETS 9-10 FOR ANCHOR DETAILS.WINDLOAD O DURATION FACTOR Cd--l.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. Z < 3 5,PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED. a w o �w c p 6.DESIGN PRESSURE OF MULLED UNITS SHALL BE CONTROLLED BY THE LESSER Z Z 8 Z w r-z w ct- 0W3m -� DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNITS. IL IQ-w ANCHOR CLIP— -- - - - -- - ANCHOR CUP z0 F omo Q w O O 0 q rC} 7.DESIGN PRESSURES AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT O 0 N N Z O.�y'a s APPLY ONLY TO THE MULLION.WINDOWS MUST BE APPROVED UNDER SEPARATE o z— z ti-7 m APPROVAL. 008U;—=(j z — R' MOLLz_ O r- e! O O > Qg-8.RESPONSIBILITY OF SELECTING FENESTRATION PRODUCTS TO MEET ANY LLO �=F-Z APPLICABLE LOCAL LAWS,BUILDING CODES,ORDINANCES OR OTHER SAFTEY i 3 O REQUIREMENTS RESTS SOLEY WITH THE ARCHITECT,ENGINEER OF RECORD, w U.y w C w V BUILDING OWNER OR CONTRACTOR, y ?=apO y 9.SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS 0 ~a w w DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY X X X CUSTOM WINDOW SYSTEMS,INC.AND MUST BE MADE OUT OF VINYL PVC OR EXTRUDED ALUMINUM. fffµunrrgr 4 Q 4 10.VERTICAL MULLED UNITS MAY BE MULLED INDEFINITELY AS LONG AS THE SINGLE p��tis PjS .REW UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED,AND MULLIONS ARE ANCHORED AS 6EiVSF SHOWN HERE IN. J f G F E D ANCHOR CUP �F No SB201 •'��: to io 9 9 11.HORIZONTAL MULLION SHALL EXTEND THE ENTIRE WIDTH OF THE MULLED UNIT. VERTICAL MULLION IS USED TO MULL SIDE BY SIDE UNITS TOGETHER. EXAMPLE HORIZJ.VERT.MULLION '9 STATE OF ;�lu� FOR SECTION VIEW ONLY '��t` °l O R L01:���.• ANCHOR CLIP—� Lucas Turner 2017-09-28 �2L O O 07:12+20:00 9/262017 LUCAS A.TURNER,P.E. FL PES 58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 X X SHEET DESCRIPTION: II I GENERAL NOTES AND TABLE OF CONTENTS ELEVATIONS GENERAL NOTES&ELEVATIONS...............I _ ORAWN SY. DATE: DP CHARTS.................................................2-3 ADE 09/27/12 BOM d EXTRUSIONS.....................................4 ANCHOR CUP EXTRUSIONS.................................................5 ONGN .: SECTION VIEWS......................................_.6.7 EXAMPLE VERTICAL MULLION FOR CWS-836 B CONFIGURATIONS&ANCHOR NOTES.......8 PVC WINDOWS FOR SECTION VIEWS ONLv INSTALLATION DETAILS..........................9-10 9FL SHEET 1:25 1 OF 10 Design Pressure Chart(PSF)for NON-INTERSECTED Impact PVC 3"Mullion H-1758,with 1522 clips using four(4)#10 Screws into WOOD or METAL or 3116"RW Tapcons or ELCO ULTRACONS into SOLID CONCRETE or WOOD per each end ofmullion.H OL LOW or GROUT-FILLED BLOCK require 114"ELC0 ULTRAC DNS. OPENING SIZE(In.) WINDOW SYSTEMS 39 45 51 57 63 69 75 318 81 87 93 99 107 318 114 120 126 132 138 145 318 19W SW 44TH AVE. _ 37 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 OCALA,FLORIDA 34474 c 42314 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 WWW.CWS.CC = 48 314 80.0 80.0 80.0 80.0 80.0 80.0 80.0 60.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 53 118 90.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 3"PVC z 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 MULL BAR 63 60.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 78.9 76.6 74.8 72.5 65.0 65.0 I 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 IMPACT 2 68 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 63.5 f 72 65.0 65.0 65.0 65.0 65.0 65.0 65.0 64.9 61.7 59.1 56.9 53.7 Q z 3 <z F OWO OW00 OP CHART IS FOR: z W_5 a NON-INTERSECTED IMPACT 3"MULLION 1758,HORIZONTAL OR VERTICAL,USING(PER END): WW z 0 z ¢ z~ ¢ O_3m 1522 CLIPS z zxM<WWOOO -(4)#10 SCREWS INTO WOOD or METAL Ov v E U a P�0.. -(4)3/16"ITW TAP CONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD a z- ?t.-O<n -(4) 1/4"ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK a O z U rn z a V O OLL ~�Qw�FO? ------------------------------------ --------- --------------- 0�U zzO1 Design Pressure Chart(PSF)for NON-INTERSECTED Impact PVC 3"Mullion H-1758,with 1776 Gips with six(6)#10 Screws into WOOD or METAL or 3/16"ITWTapcons or ELCO ULTRACONS info SOLID CONCRETE or w OLL(n w v}i p w WOOD per each end ofmullion. HOLLOW or GROUT-FILLED BLOCK require 114"ELC0 ULTRACONS. n¢. x�- x O OPENING SIZE(In.) = x~IY W 0 EL�w rn 39 45 51 57 63 69 75 318 81 87 93 99 1073/8 114 120 126 132 138 1453/8 a ~ n. o- 37 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 c 42314 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 60.0 80.0 80.0 80.0 80.0 80.0 80.0 ��`LQpSOREWrT�,� 48 314 80.0 80.0 60.0 80.0 80.0 80.0 80.0 80.0 80.0 60.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 53 116 80.0 80.0 80.0 80.0 8D.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 1 `py=GENS' GAT; W 9 57 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 No 59201 : s -I !7g2 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 =v: ;¢ 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 13: STATE OF :W� 65.0 65.0 65.0 65.0 65.0 65.0 65.0 64.9 61.7 59.1 56.9 53.7 .......... q A DP CHART IS FOR: � �.�`�� NON-INTERSECTED IMPACT 3"MULLION 1758,HORIZONTAL OR VERTICAL,USING(PER END): NOTES: 1.THE MULL BAR IN FOCUS FOR ANY GIVEN CONFIGURATION IS SHOWN IN BOLD. 1776 CLIPS -(6)#10 SCREWS INTO WOOD or METAL 2.AN INTERSECTED MULL BAR HAS OTHER MULLBAR(S)ATTACHED TO IT Z -(6)3/18"ITTAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD THROUGH THE USE OF MULLOWN BARICLIIPS.HANI W 9/26/2017 -(6) 1/4"ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK INTERSECTED MULL BAR WILL ALWAYS BE ATTACHED TO THE SUBSTRATE AT BOTH ENDS. LUCAS A.TURNER,P.E. 3.NON-INTERSECTED MULL BARS CAN BE ATTACHED FL PE#58201 TO THE SUBSTRATE AND OTHER MULL BARS. 1239 JABARA AVE. TWIN TRIPLE TRANSOM OVER TWIN TRANSOM OVER TRIPLE NORTH PORT,FL 34288 VERTICAL MULLION VERTICALMULUON VERTICAL MULLION VERTICAL MULLION PLE PH.941-380-1574 r TWIN TRIPLE TONTAL MUL i HORIZONTAL MULLION HORIZONTAL MVLLION HORIZONTAL MUTAION SHEET DESCRIPTION; DP CHARTS r r NON-INTERSECTED z z = y OPENING MULLS J (� z y SIZE DRAWN BV; DATE: J i ADE 09/27/12 L LI j Z DWGM O o CWS-836 8 L I I L I I 7- scALSHEET 4--- OPENING SIZE --1 OPENING SIZE ( OPENING SIZE --I OPENING SIZE F-- -MULL LENGTH -�I 1 F'-MULL LENGTH --I MULL LENGTH r i 1.1 2 OF 10 Design Pressure Chart(PSF)for INTERSECTED Impact PVC 3"Mullion H-1758,with 1522 Gips using four(4)#10 Screws into WOOD or METAL or 3/16"TTWTapcons into SOLID CONCRETE or WOOD,or 1776 clips wi!h six(6)#10 Screws into WOOD or METAL or 3/16"ITW Tapcons into SOLID CONCRETE or WOOD per each end of mullion. HOLLOW or GROUT-FILLED BLOCK require 1/4"ELCO ULTRACONS. OPENING SIZE(In.) WINDOW SYSTEMS 39 1 45 51 57 63 69 75 318 81 87 93 99 1 1103/8 114 120 126 132 138 145 318 1900 SW 44TH AVE. 37 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 OCALA,FLORIDA 34474 c 42314 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 WVNW.CWS.CC = 48 314 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 53118 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 3"PVC W 57 50.0 50.0 5D.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 48.1 MULL BAR 63 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50,0 50.0 50.0 50.0 50.0 50.0 49.4 47.3 1 1 IMPACT 68 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 49.8 47.6 f 72 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 45.4 44.0 75.375 50.0 50.0 5D.0 50.0 50.0 50.0 50.0 50.0 50.0 46.8 44.0 40.0 z 3 <z z O w 0 10-,c OP CHART IS FOR: WZ O? IY r z p- INTERSECTED IMPACT 3"MULLION 1758,HORIZONTAL OR VERTICAL,USING EITHER(PER END): 0 w 3 3:ED _ 1z zxf¢�wo0 522 CLIPS 0 ONO <=I-W -(4)#10 SCREWS INTO WOOD or METAL y- ~'n a z -(4)3/16"ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD O Z U w 2 Z=LLZ _(4) 114"ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK -0 O O 'Fi.-z 1767 CLIPS OOKrrnowrnw -(6)#10 SCREWS INTO WOOD or METAL - -(6)3/16"ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD Z N a O 0 r Cn a wx-O a=ofy (6) 114"ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK 0 x w�w HORIZONTAL MULLION 'v:•• No 58201 TWINrrRIPLE VERTICAL MULLION a= STATE OF ;U �'•� w .F •..<,0R10P, �2�• --- -- a S �SINGLE1 O z TWIN OR o TRIPLE1 --- -- I IUNITSI I LI IBELOWI 9/26/2017 OPENING SIZE H I^ MULL LENGTH LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: NOTES: DP CHART 1.THE MULL BAR IN FOCUS FOR ANY GIVEN INTERSECTED MULLS CONFIGURATION IS SHOWN IN BOLD. 2.AN INTERSECTED MULL BAR HAS OTHER MULL DRAWN BY: DATE: BAR(S)ATTACHED TO IT(SHOWN IN DASHES) ADE 09/27112 THROUGH THE USE OF MULL BAR CLIPS.AN WG K REV.: INTERSECTED MULL BAR WILL ALWAYS BE ATTACHED TO THE SUBSTRATE AT BOTH ENDS. CWS-836 B 3.NON-INTERSECTED MULL BARS CAN BE ATTACHED SCAL: SHEET TO THE SUBSTRATE AND OTHER MULL BARS, 1:1 3 OF 10 ITEM PART# DESCRIPTION FRAME TYPE OPENING •'T'MULLBAR CLIP "L"MULLBAR CLIP I H-1758 13/8"z 3"MULLION TUBE LINE ITEMS NOT USED: (F-1622-XXX) (F-1767-XXX) 2 #10 OR#12 HEX WASHER HEAD TEK SCREW'(see note beloWj 5-6.12 NEW F-1522-013 F-1767-001 3 #10 x 1 112",PANHEAD PHILIPS DNC FLANGE WINDOW SYSTEMS 4 #10 FUST WASHER RETRO F-1522-006 F_1767-001 1900 SW 44TH AVE. 7 S-1897 MULLION CLIP FIN NEW F-1522-013 F-1767-004(L&R) OWNVNCWS.CCA 34474 8 SEALANT RETRO F-1522-013 F-1767-004(L&R) 9 S-1895 DRIP CAP NEW NOT RECOMMENDED F-1767-001 BOX 10 S-1896 FLANGE ADAPTER RETRO F-1522-006 F-1767-001 3"PVC 11 S-6018 MULLION INTERIOR COVER MULL BAR 13 P3486 MULL BAR CAP 14 F-1522-013 3"SLOTTED NEW CONTRUCTION FIN MULL CLIP IMPACT 15 F-1522-006 3"SLOTTED T-CLIP 16 F-1767-001 L-ANGLE 3"MULL CLIP,STANDARD ¢ z 3 ¢Z$ 17 F-1767-004L L-ANGLE 3"MULL CLIP,FIN,LEFT r ❑lit p Q W p w 18 F-1767-004R L-ANGLE 3"MULL CLIP,FIN,RIGHT w z O Z 0' z r 19 i#10 HEX WASHER HEAD TEK SCREWa w'S Or 3 3LD 20 910 FHTEKSCREW O OI=-O¢aWpp USE WOOD SCREW SIZE(#10 OR 012),SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENT L) U rn�Z IL I--U3 d Q gp ZUt!!Z0VU 1314" 112"- 17116" --17176' of z¢y�W OO ZZ 11116"_����_-��+,,I 9132 F" '1 @672 a F- j O 7116"Lr 1/2" T�-I -+-I 7/16• LLJr K t}n C)W c W 10. 11a" 10 9 I 7/16" zN0. p�mr )_ 1116' 1/18" I + Q. W= 2 1/16" DRIP CAP 5.1895 1 tY16' 1 1W16* MULLION YB' 0- K 3 a MULLION INTERIOR 11 15/16°I COVER S-6018 FLANGE ADAPTER 5.1896 1 Yt6" 2 7/16' 119. LT%71. `punupyr'' 1 318 4118' pe10RE14'�,! r t ( �� 1L9 (TrP) are" ;J� .�tGEriS�GA��� No 58201 9 2 TOP VIEW 2 7/16" 213!16" 1!B" '-A' STATE OF •.•.,F P.r2W: (•F-21/i6"—�•{ t I �i�FS.Cpg10,.•G``�. �i---(- II O7 LI Ya•�t 3!8•-�I 15 h,SiONA L1 3116 1/8, 2 3176' 3'MULLBAR H-1758 118" MULLION CLIP S-7897 9/26/2017 1a LUCAS A.TURNER,P.E. 2 114^ F-1522-006 FL PE#58201 1/B" RETRO/FLANGE CLIP 1239 JABARA AVE. LNORTH PORT, 34288 ` PH.941J80-1-1 574 4 718" SHEET DESCRIPTION: F-1522-013 NEW CONSTRUCTION/FIN INSTALLATION BOM AND EXTRUSIONS A SCORE,BEND AND BREAK DRAWN BY: DATE: TO REMOVE FIN FOR FRAME ATTACHEMENT TO MULL BAR ADE 09/27/12 DETAIL A DWG#; WET— TYP.FIN FRAME 3:1 CWS-836 B SAL SHEET NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. 1.2 4 OF 10 FRAME TYPE OPENING "r,MULLBAR CLIP "L"MULLBAR CLIP '��/�/�) (F-1522-XXX) (F-1767-XXX) ((IAUU(j(1/7` FLANGE NEW F-1522-013 F-1767-001 WINDOW SYSTEMS LTJ RETRO F-1522-006 F-1767-001 19W SW 44TH AVE. NEW F-1522-013 F-1767-004(L&R) OCALA,FLORIDA 34474 FIN VNMN'CWS.CC RETRO F-1522-013 F-1767-004(L&R) NEW NOT RECOMMENDED F-1767-001 BOX RETRO F-1522-006 F-1767-001 3"PVC MULL BAR IMPACT z 3 aZ0 owo owoo 1a w zoz W--t o av��zo�;m OU 00(A�—z ma F+—2 3/4' --2 114" 0 ZO U Z j V Vl OWOF OZ H �p�Yu1S�� 12 3/49 27/16. K z w 0_J to� 0 w,-0 a=te} a d C, I 316"77RX)-- I 7116"THRU(TYP) 114•THRU(TYP) I OUTSIDE SF I 114"(TYP) 7116"(TYP) _ No 58207 •.mom r 318" Q 318" ' '9't STATE OF ;�4l� 15/8„ 12314"1 1518• I i�i'�S .<,O R1�•'('j S/ EN�� NA +F-1110O �aO��� 16 1/8' 1 -Z1 r� 6718" 9/26/2017 . 112" 112"-L---1 LUCAS A.TURNER,P.E. 2 314" 2 3/4• ( "L"ANGLE 3•STANDARD MULL CLIP-F-1767.001 FL PE#58201 s1239 JABARA AVE. NO 5^ i RTH PORT.FL 34268 "L"ANGLE 3"MULL CUP,FIN(LEFT)F-1767-004L "L"ANGLE 3"MULL CUP,FIN(RIGHT)F-1767.004R I PH.941-380-1574 OUTSIDE I SHEET DESCRIPTION EXTRUSIONS DRAWN BV: DATE: ADE 09/27/12 OWG#: REW CWS-836 B SC SHEET I 1.2 5 OF 10 CSrS+�(kyl6UU � WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA.FLORIDA 34474 WW W.CWS.CC 3"PVC MULL BAR SEAL BEHIND FLANGE APPLY SEALANT ALONG FULL IMPACT SEAL BEHIND FLANGE I PRIOR TO ATTACHING PRIOR TO ATTACHING TO MULLION I Z LENGTH OF WINDOW FRAME 2 TO MULLION I GROOVE PRIOR TO ATTACHING II COVER 1 Z Q 9 tit 9 111 11 ii 2 WJO `CwOW FIN MUST BE REMOVED � Z O? � ~ C= WHERE WINDOWS If jr In Fa..w Z OF If jr_ CONNECT TO MULL ZO Z F�¢ W w O O U U V)I-ZQ-11---0 d ! Z;s-ZI-'BD Z OW F-ZLL�OO lZ I i FFFO- I ( I. L)�Ot6 A V RTI ALMORIZ NTAL MULL BAR SECTION LIJ— 0 o of w N A HORIZONTAL MULL BAR SECTION I A HORIZ NTAL MULL BAR SECTION 6 BOX FRAME WINDOW ? a 0 p V) B FLANGE FRAME WINDOW I s FIN FRAME WINDOW o D-x > I a a W (L I I ---------------.._._.._---I- -- -------------------- ------ -...__.. ..... ._.__......._.._ - - -------- I.IORE W 11 1 2APPLY SEALANT ALONG FULL C,p`',��iCENgF G�F� 11 1 2 I LENGTH OF MULLBAR GROOVE .� PRIOR TO ATTACHING DRIP No 58201 ADAPTOR I + jr D '•O,o•,STATE OF FIN MUST BE REMOVED (OR IQ. WHERE WINDOWS I 9 i ���SS�ONA1.�?G`• CONNECT TO MULL I O .... - i -- I � r- a I DETAIL A Z I 9/26/2017 SEAL BEHIND FLANGE 10 (SEE DETAIL ' LUCAS A.TURNER,P.E. SEAL BEHIND FLANGE 1 (SEE DETAIL B) I PRIOR TO ATTACHING I PRIOR TO ATTAHING APPLY SEALANT ALONG FULL FL PE#58201 CTO MULLION TO MULLION 1 LENGTH OF MULLBAR GROOVE 1239 JASARA AVE. PRIOR TO ATTACHING FLANGE NORTH PORT,FL 34288 e VERTICAL MI LI �E� BATL(ZN i �VERTICAL MULL BAR SECTION ADAPTOR PH.941-380-1574_ i 6 FLANGE FRAME WINDOW s FIN FRAME WINDOW I I SHEET DESCRIPTION: L I SECTION VIEWS MULLS �� �� ORAWNBY: DATE: ADE 09/27/12 Owa R: V.: T. DETAIL B CWS-636 B scALE: SHEET 1.2 6 OF 10 WINDOW SYSTEMS1900 SIN 44TH AVE. Q Q Q Q OCALA.FLORIDA 34474 W W W.CWS.CC A s' —„ — - — - ------ 3"PVC Q til :'r` 1 if} r Q MULL BAR p (:; ii, r14 IMPACT u u' 711L.- z z woo Mw �lj zOZ �_ r - - - - _ - v awyZi,-33= zx�a�WpO A , o oro�axrx SECTION VIEW A-A U Z''z 0.'L TO VIEWz } �ZwWo°o? FRAME FIN FRAME 30rrz 00�Ln�r}now�lw z EL w0�U) 0 w�0 n.=Cc>- z a rx- a W 0- 5 - 5"MULLBAR(H•1760) 2 4'MULLBAR(H-1759) (SEE SEPARATE APPROVAL F11 - 2 APPROPRIATE DP CHARTS) APPROPRISEE ATE OP CHATE RTS]FOR P Y C= 0VPNo 58201 :9L 9STATE OFSEE NOT11114_MAX.EDGE DISTANCE 11N6" rDMAX E GE DISTANCE �O�F''.,<O SEE NOTE 1 7 J1L1G=MAX.EDGE DISTANCE 1 SEE NOTE 1 7 t ��SS NG�� 1 ONA 1 i19 SEE NOTES 1 d 2 y 19 �- 1 19 SEE NOTES 1&2 (1 EA.ICUP) (1 EAJCLIP) (1 EA/CLIP) SEE NOTES 1 8 2 SEE NOTE 4 0 SEE NOTE 4 0 9/26/2017 SEE NOTE 4 0 C 3"HORI2.TO 3"VERT.MULLBAR SECTION LUCAS A.TURNER,P.E. C 5"HORIZ.TO 3"VERT.MULLBAR SECTION ; 4'HOGIZ TO 3"VERT.MULLBAR SECTION 7 FL PE#58201 7 FLANGE M N O 1239JABARA AVE. NORTH PORT,FL 34288 NOTES PH.941-380-1574 1.SUDS CLIP INTO LOCATION AND SECURE WITH ITEMS 19(OTY 1)AND 20(CITY 1),AS SHEET DESCRIPTION; SHOWN ABOVE. SECTION VIEWS 2.PRE-DRILLED HOLES(THRU HNCUP 1897),BY THE INSTALLER, MULL INTERSECTIONS MAY BE LOCATED AS NEEDED WHILE MAINTAINING A MINIMUM CUP EDGE DISTANCE OF 9132"AND A MINIMUM CENTER TO CENTER SPACING OF 112'. DRAWN BY: DATE: 3.THE ABOVE SECTIONS APPLY TO ALL MULLBAR-TO-MULLBAR CONNECTIONS, ADE 09/27/12 REGARDLESS OF ORIENTATION(.e.,HORIZONTAL OR VERTICAL).THE FULL LENGTH D O x: REV.: MULL MUST BE THE SAME DEPTH,OR GREATER,THAN THE INTERSECTING MULL CWS-836 B 4.INTERIOR MULLANCHOR ATTACHMENT SCREW THRU VERTICAL MULL INTO MULL SCALE: SHEET CUP. PRE-DRILL PILOT HOLE THRU ALL MATERIAL 1:2 7O 10 NOTES: 1.THE MULL BAR IN FOCUS FOR ANY GIVEN �Ss�(S4f0YlYll!/UU(1• CONFIGURATION IS SHOWN IN BOLD. TWIN TRIPLE TRANSOM OVER TWIN TRANSOM OVER TRIPLE 2.AN INTERSECTED MULL BAR HAS OTHER MULL WINDOW SYSTEMS VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION BAR(S)ATTACHED TO IT(SHOWN IN DASHES) 1900 SW 44TH AVE. r r THROUGH THE USE OF MULL BAR CLIPS. AN OCALA,FLORIDA 34474 INTERSECTED MULL BAR WILL ALWAYS BE WWW,CWS.CC ATTACHED TO THE SUBSTRATE AT BOTH ENDS. _ .r 3.NON-INTERSECTED MULL BARS CAN BE ATTACHED z = _ = TO THE SUBSTRATE AND OTHER MULL BARS. 3"PVC z ' MULL BAR Z IMPACT J J J I LI L a azFo F— OPENING SIZE--1 ---I OPENING SIZE 4�--- OPENING SIZE—^1 OPENING SIZE I+ z OW J O a F Z W O ZV)Z 00:3m a 3 0 O�0Oa<W TDO HORIZONTAL MULLION U U y(1 Z a H-(n n. TWINRRIPLE _ a Z Z_I-Z)U) TWIN TRIPLE TWINlTRIPLE VERTICAL MULLION 00 U O U HORIZONTAL MULLION HORIZONTAL MULLION HORIZONTAL MULLIONZ 0 w p 2 O z 0 y Z S ___ _— y _ LLy WU)OW(n W WW t OPENING 2 ISINGLE1 =0- w O �n L SIZE z z J IL I RTWINI O rs-~a AWN y J O 1TRIPLEI a ¢ a a i ——— —— 'UNITS 0 z BELOW d PTSOREl1��r L- 4� 7°— MULL LENGTH --) r I—MULL LENGTH —a � 5-' G MULL LENGTH '� r—OPENING SIZE LENGTH I I `OP;��GENSF'';Q1� MULL No 58201tr :1 ' STATE OF ;UJ NOTES: 1.AT MULLION LOCATION,ATTACH WINDOW UNIT(S)TO MULLBAR THRU FRAME AS SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENTS.IF ALUMINUM ATTACHMENT IS NOT SPECIFIED IN THE WINDOW UNIT APPROVAL DOCUMENTS,FOLLOW THE ANCHOR SPACING AS INDICATED IN THE WINDOW APPROVAL FOR ATTACHMENT TO WOOD SUBSTRATE,USING A HEX WASHER HEAD TEK SCREW OF THE SAME SIZE(M10 OR 012)AS THE WOOD SCREW INDICATED IN THE WINDOW APPROVAL.TEK SCREWS SHALL BE LONG ENOUGH TO ENSURE THREE(3)THREADS OF PENETRATION BEYOND THE INSIDE WALL OF MULLBAR. 9/26/2017 2.MULL CLIP INSTALLATION ANCHOR TYPE,SIZE.SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS.SEE TABLE 1,SHEET 9. LUCAS A.TURNER,P.E. 3.ALL MULL CLIP INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED FL PE#58201 WOOD MUST BE PROTECTED TO PREVENT REACTION. NO1239RTH PORT,PORT,PAVE. FL 34288 4.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE PH.941-380-1574 MINIMUM SPECIFIED IN TABLE 1,SHEET 9. SHEET DESCRIPTION: 5.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE-1X BUCKS CONFIGURATIONS AND ARE OPTIONAL. ANCHORAGE NOTES 6.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED AS INDICATED BY THE PRE-DRILLED HOLES AS SHOWN IN THE CLIP LAYOUTS ON SHEETS 4.5. DRAWN BY: DAT ADE 09/27/12 7.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG a: V.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 9. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-836 B 8.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCAL: SHEET FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMAWVDMA 250(BOX WINDOWS),FMA/AAMA/WDMA 300(EXTERIOR DOORS) 1:1 8 OF 10 WINDOW SYSTEMS 1900 SW 44TH AVE. Kms/ OCALA,FLORIDA 34474 WWW.CWS.CC 3"PVC MULL BAR IMPACT RETRO FIT "L"ANGLE MULL BAR CLIP MULL BAR CLIP TWO REO'D PER EACH END OF MULL Q z Q z if 11 owco MULL BAR ).L 11 MULL BAR z O W p Q k z W Z W J O o Ztp/1-}zow _I. _____ Z Z=m2 woo II J,^ - INSTALLATION ANCHOR 1� INSTALLATION ANCHOR O O F-O Z C�O SEE TABLE 1 '� `v J SEE TABLE 1 ZoZ Z 7-?F h -'`- =�' ADD STRUCTURAL ELEMENTS _ JI^^ -�"�' L ADD STRUCTURAL ELEMENTS Q O Z LL W Zp p a U SEALANT ALONG - -_--- SEALANT ALONG - i=- OUTSIDE EXPOSED - -- =-— - AS REO'D TO MAKE LEVEL FOR OUTSIDE EXPOSED - — - AS REQ'D TO MAKE LEVEL FOR } O W F==p Z MULL BAR MULL BAR 0_ a !- 1_ EDGE BY INSTALLER EDGE BY INSTALLER Q w K>v1 U Q v PERIMETER SEALANT PERIMETER SEALANT W 0 0 d.�%p W U7 W p J! F BYINSTALLER MIN.EMBEDMENT BY INSTALLER MIN.EMBEDMENT R =d p UJ INSIDE AND OUT INSIDE AND OUT SEE TABLE 1 SEE TABLE 1 =f"� W W o I- a a SUBSTRATE BY OTHERS SUBSTRATE BY OTHERS SEE TABLE 1 SEE TABLE I MIN.EDGE DIST, SEE TABLE EDIST. SEE TABLE P lG D VERTICAL SECTION E VERTICAL SECTION 9 TYPICAL FLANGE(RETRO FIT)ANCHORAGE 9 TYPICAL FLANGE("U ANGLE)ANCHORAGE HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION ' No 58201 :9 X90; STATE OF ;�tL %"N Fl 0 R N0 s 1ONA tiN�p L- 9/26/2017 NOTES: LUCAS A.TURNER,P.E. 1.BOX FRAME MULL INSTALLATION SIMILAR TO FLANGE FRAME. FL # 01 TABLE 1:APPROVED MULL CLIP INSTALLATION FASTENERS 1239 JA JABARA RA AVE.A SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. 2.SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS NORTH PORT,FL 34288 CONC PH.941-380-1574 3" AFTER INSTALLATION. CONCRETE(2.85 KSI MIN.) 3116"ELCO ULTRACON 1314" 1" SHEEP DESCRIPTION'. 3.RECESS RETRO MULLION CLIP 318"MAX.FOR CLEARANCE OF WINDOW INSTALLATION DETAILS HOLL UNIT AS NEEDED. FLANGE 3116"ITW TAPCON 1-3/8" 718" 2X MIN.SOUTHERN PINE(G=0.55) OR ELCO ULTRACON 4.FOUR(4)ANCHORS REQUIRED PERT'MULL CLIP,SEE SHEETS 2-3. DRAWN BY DATE THREE(3)ANCHORS REQUIRED PER"L"MULL CLIP,SEE SHEETS 2-3. 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1318" 718" ADE 09/27/12 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILTI KWIK-FLEX OR ITN FULL THREAD S.SEAT MULLION TIGHT TO MULL CLIP, 0: .. (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" 7116 6.FOR ANCHORAGE DETAILS FOR THE WINDOW,REFER TO THE WINDOW CWS-836 B 118"ALUM.(6063-75 MIN.)OR 410 GRADE 5 SELF-TAPPING/ FULL THREAD 7116„ SPECIFIC INSTALLATION DETAILS. TEA—LT— SHEET 118"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" 1:2 1 9 OF 10 WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CWS.CC 3"PVC MULL BAR IMPACT a - 3: ¢z3� RETRO FIT "L"ANGLE CUP 1- 0 W 0 Q W p W MULL BAR CUP TWO REO'D PER EACH END OF MULL Z LU-10 �Z W ZOZ -- - 0 Qrn� 0M3m IL �w rzr-32x MULL BAR MULL BAR OV 0-06 F�m a 1-- ,JLJ z zcZz�On INSTALLATION ANCHOR = Y�'L = INSTALLATION ANCHOR Q 0 Z O 16 Z:D LL O SEE TABLE 1,SHT 9 '� ' 6EE TABLE 1.SHT 9 } Q3 O F U~Z QK d'K�}O'SO SEALANT ALONGE SEALANT ALONGE l=am-' w LL 0 LU rn 0 W��W1y1 OUTSIDE EXPOSED OUTSIDE EXPOSED W W O J r/7 EDGE 8Y INSTALLER "o.r EDGE BY INSTALLER of o• 0 ° p W F=-�CL WO�y EXTERIOR FINISH I MIN.EMBEDMENT EXTERIOR FINISH °• 41 MIN.EMBEDMENT (L F=- D. K d BY OTHERS SEE TABLE 1,SHT 9 BY OTHERS SEE TABLE 1,SHT 9 PERIMETER SEALANT PERIMETER SEALANT BY INSTALLER BY INSTALLER group INSIDE AND OUT INSIDE AND OUT yyy1,,HOREkV SUBSTRATE BY OTHERS SUBSTRATE BY OTHERS G E N SEE TABLE 1,SHT 9 SEE TABLE 1,SHT 9 ^v' " MIN.EDGE DIST. MIN.EDGE DIST. No 58201 _ F VERTICAL SECTION SEE TABLE 1,SHT 9 SEE TABLE 1,SHT 9 * i G VERTICAL SECTION 10 TYPICAL FIN(RETRO FIT)ANCHORAGE 10 TYPICAL FIN("L"ANGLE)ANCHORAGE %9; STATE OF HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION %0% %�F• �ORIQP•G��: X� 9/26/2017 LUCAS A.TURNER,P.E. NOTES: FL PE 11158201 1239 JABARA AVE. 1.SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS NORTH PORT,FL 34288 AFTER INSTALLATION. PH.941-380-1574 SHEET DESCRIPTION'. 2.RECESS RETRO MULLION CLIP 3/8"MAX.FOR CLEARANCE OF WINDOW UNIT AS NEEDED. INSTALLATION DETAILS FIN 3,FOUR(4)ANCHORS REQUIRED PER'T"MULL CLIP,SEE SHEETS 2.3. DRAWN BY: ATE: THREE(3)ANCHORS REQUIRED PER"L"MULL CLIP,SEE SHEETS 2.3. ADE 09/27/12 4.SEAT MULLION TIGHT TO MULL CLIP. DWG rr. V.: S.FOR ANCHORAGE DETAILS FOR THE WINDOW,REFER TO THE WINDOW CWS-836 B SPECIFIC INSTALLATION DETAILS. SCALE: SHEET 1:2 100F 10