Loading...
HomeMy WebLinkAboutProduct Approval (2) (IE RegulationBusiness & Professional BCIS Home I Log In I User Registration I Hot Topica Submit Surcharge Stats&Facts I Publications I Contact Us BCIS Site Map Links Search I Floridor u..UP blApproval RECEIVED ic User Product Approval Menu>Product or Ao ligation Search>Application List>Application Detail AUG 2 9 2018 0OFF1c5-OF THE FL# FL15970-RS ST. LLiGIa Cown':Yr PormMing SECRETARY Application Type Editorial Change -- •=�-=- �= ''"'~ Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and rated by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft. Myers,FL 33912 (800)432-2204 Ext 4305 ifiesher@eastemnietal.com Authorized Signature James Flesher jflesher@eastemnietal.com Technical Representative Timothy J. Hoard Address/Phone/Ercall 10030 Bavaria Road Fort Myers, FL 33913 (800)432-2204 Ext 4314 thoard@eastemmetal.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Certification Mark or Listing ` Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2005 ASTM E1886 2005 ASTM E1996 2006 TAS201 1994 TAS202 1994 TAS203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15970 R5 Equiv EER 2098 Rev l.pdf Product Approval Method Method 1 Option A Date Submitted 07/09/2018 Date Validated 07/09/2018 Date Pending FBC Approval Date Approved 07/15/2018 Summary of Products FL O Model,Number or Name Description 15970.1 Series HR 10005 Horizontal Roller Series HR 10005 Horizontal Roller- LMI HVHZ Limits of Use Certification Agency Certificate Approved for use In HVHZ:Yes FL15970 R5 C CAC NI011287-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 04/30/2021 Design Pressure: +60.0/-60.0 Installation Instructions Other: FL15970 R5 II EAS0001 RevA OX Horizontal Roller ss.pdf Verified By: Robert J.Amoruso,P.E.49752 Created by Independent Third Party:Yes Evaluation Reports FLIS970 R5 AE NOA Saflex PVB 15-1201.11.Ddf FLI5970 R5 AE PER 2098 Rev l.odf Created by Independent Third Party:Yes 15970.2 Series HRP 1000F Horizontal Roller Series HRP 1000F Horizontal Roller- LMI HVHZ Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL15970 R5 C CAC NI011286.01-R2.pdf Approved for use outside HVHZ:Yes FL35970 R5 C CAC NI011286-Rl.Ddf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +60.0/-60.0 04/30/2021 Other: Installation Instructions FLI5970 R5 II EAS0002 RevA XOX Horizontal Roller ss.pd Verified By: Robert J.Arroruso,P.E. 49752 Created by Independent Third Party:Yes Evaluation Reports FL15970 R5 AE NOA Saflex PVB 15-1201.1l.Ddf FL15970 R5 AE PER 2098 Rev l.Ddf Created by Independent Third Party:Yes Pack wext Contact Us::2601 Blalr Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Coyyriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your a-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: ® M Credit Card Safe Q EASTERN ARCHITECTURAL SYSTEMS N Q SERIES HR 10005 HORIZONTAL ROLLER - LMI Ln LO INSTALLATION ANCHORAGE DETAILS �* o 0 N _ @ a E a E GENERAL NOTES: INSTALLATION NOTES: g a 1. THE PRODUCT SHOWN HEREIN IS DESIGNED TO COMPLY WITH THE CURRENT EDITION OFTHE FLORIDA BUILDING 1. ONE(1)INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. CODE(FBC)INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)AT THE DESIGN PRESSURES STATED HEREIN. 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE N 2- THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON SIGNED AND SEALED TEST REPORT(S)NO. USED FOR PRODUCT INSTALLATION. U] O LL ESP009274P-3, ESP009274P-4,ESP009274P-8 AND ESP009274P-9 AND ASSOCIATED LABORATORY DRAWINGS. w Lr.w 3. ANCHORS ARE TO MATCH TYPE,SIZE,EDGE DISTANCE AND EMBEDMENT OF THOSE SHOWN IN THE W J N z UQ) 3. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY AND 2X FRAMING ASA MAIN WIND FORCE INSTALLATION ANCHOR SCHEDULE SHOWN ON THIS SHEET FOR THE RESPECTIVE SUBSTRATE. E- 0 W O W REOf SISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE STRUCTURE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S).MAXIMUM C o ALLOWABLE SHIM SIZE IS 1/4 INCH.SHIM WHERE SPACE OF 1116 INCH OR GREATER OCCURS.SHIM(S) 1,tW � Z 4. IX AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. F-1 ps Z STRUCTURE.BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF O OO = RECORD. 5. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES(INCLUDING BUT NOT LIMITED TO �•' m a) If—i~ -� Q STUCCO,FOAM,BRICK VENEER,AND SIDING). E C*. = I g m~ Z 5. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A a a SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED 6. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT O Z HEREIN,SITE SPECIFIC DOCUMENTS SHALL BE PREPARED FOR USE WITH THIS DOCUMENT, MATERIAL OR HAVE CORROSION RESISTANT COATING.DISSIMILAR METALS INCLUDING FASTENERS E d THAT MAY COME INTO CONTACT WITH ALUMINUM FRAMING SHALL HAVE BEEN PROTECTED. x x O 6. THIS PRODUCT COMPLIES WITH THE REQUIREMENTS OF THE HIGH VELOCITY HURRICANE ZONE(HVHZ)FOR In U o V) Z OPENING PROTECTION OF THE CURRENT EDITION OF THE FLORIDA BUILDING CODE AND DOES NOT REQUIRE AN 7. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK,DO NOT INSTALL INSTALLATION ANCHORS INTOw E' 0`- IMPACT RESISTANT COVERING. MORTAR JOINTS.EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR O 0 O d 6.1. FOR INSTALLATION 30 FT.ABOVE GRADE,ALL UNITS MUST BE SAFETY GLAZED OR COVERED BY AN IMPACT JOINT INTO FACE SHELL OF BLOCK PROTECTIVE SYSTEM MEETING THE REQUIREMENTS OF THE CURRENT EDITION OF THE FLORIDA BUILDING Z w CODE. 8. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S as INSTALLATION INSTRUCTIONS.ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS W 7. WHEN USED IN AREAS OUTSIDE OF THE HIGH VELOCITY HURRICANE ZONE(HVHZ)REQUIRING WIND BORNE DEBRIS THAN THE MINIMUM STRENGTH SPECIFIED IN THE INSTALLATION ANCHOR SCHEDULE ON THIS SHEET. to K yae PROTECTION,THE OPENING PROTECTION REQUIREMENTS OF THE CURRENT EDITION OF THE FLORIDA BUILDING CODE ARE MET.AN IMPACT RESISTANT COVERING IS NOT REQUIRED.THIS PRODUCT MEETS MISSILE LEVEL"D'AND W to o 412 INCLUDES WIND ZONE 4 AS DEFINED IN ASTM E 1996 AS MODIFIED BY THE CURRENT EDITION OF THE FLORIDA " BUILDING CODE. DESIGN PRESSURE RATING(PSF) IMPACT RATING B. MATERIALS 8.1. WINDOW FRAME MATERIAL:EXTRUDED ALUMINUM 6063-T60.063"THICK. +60.01-60.0 LARGE MISSILE 82. WINDOW SASH MATERIAL-EXTRUDED ALUMINUM 6063-T6 0.062"THICK 9. GLASS MEETS THE REQUIREMENTS OFASTM E1300-04e1 GLASS CHARTS. ANCHOR SCHEDULE SEE SHEET 3 FOR GLAZING DETAILS. .) EDGE DISTANCE ANCHOR CAPACITIES 10. DESIGNATIONS"X"AND"O"STAND FOR THE FOLLOWING(AS APPLICABLE): SUBSTRATE INSTALLATION SCREW HEAD MANUFACTURER EMBEDMENT SCREW SIZE ANOfOR IIMwIm (I�mw BASED ON 10.1. X:OPERABLE SASH TSE TYPE SPECIFICATION 102. O:FIXED SASH CONCRETE THRU-FRAME FIATORPAN 3116" ITW TAPCONS"' 1-12" 1-118" MIN.2000 PSI CONCRETE 11. IN ACCORDANCE WITH THE CURRENT EDITION OF THE FLORIDA BUILDING CODE,WOOD SHALL HAVE BEEN HEAD Robert J.Amoruso,P.E. PRESERVATIVE TREATED OR SHALL BE OF A DURABLE SPECIES. FL P.E.No.49752 12. ALL UNITS UNDER THIS APPROVAL SHALL USE SETTING BLOCKS IN COMPLIANCE WITH THE CURRENT MASONRY FLAT OR PAN STRENGTH ;7 Digitally signed EDITION OF THE FLORIDA BUILDING CODE WHEN APPLICABLE. (BLOCK/CMU) THRU-FRN°E HEAD 3116" ITW TAPCONSI'F 1" 2• CONFORMANCETOASTM by Robert J. TABLE OF CONTENT C-90,MEDIUM WEIGHT I' Amoruso FLATOR PAN ANSIBt8.6.1 yj,NFS',wo, ON:cn=Robert J. SHEET DESCRIPTION NO.10 WOOD WITH AMINIMUM 'e��`O`"8`s°?`' Amoruso,o, 1 GENERAL AND INSTALLATION NOTES wooD THRO-FRAME HEAD (NooD scREvt7 1-318" 314" SPECIFIC GRAVITY OF " '°'° �:ou=Arc Product FLAT OR PAN ASME 818.6.4 0.55. `* Desi nGrou 2 ELEVATION AND ANCHORING LAYOUT HEAD No.10 (fPPPINGSCREW) c�.<'"a o° '4= 9 t NOTES: �'S�P°SION�E�p�"'""� email=robert@pt 3 VERTICAL CROSS SECTION AND GLAZING DETAILS c-corp.com,_.__'' 1)0W(ADVANCED THREADFORM TECFINOLOGY)TAPCONSWLL BEUSED FORCONCREMMASONRY P6TALLATIOPI ••,•,� a=US 4 HORIZONTAL CROSS SECTION 2)FORWOODSCIRENSIFSRtrnNGISACONCBV,DRLL0.1IT(34DRLLSZE)PLOTHOLEFORNO.10WOOD SaRew. Date:2075.06.14 5 BILL OF MATERIALS AND COMPONENTS 3)FORTAFPNGSCREWSFSPLRTINGSACONCERN,CRLL0.121"(31CPoLL SIZE)PILOTHOLEFORNO I0TAFPIGSCFZEN. / 1638:40-04'00' m m N N 74 O.A. FRAME WIDTH � to 7 MAX. 7.5" MAX. 7 MAX. I _ TYP. O.C. NN � P. q P. Y s R N o _� 5 <U 6 MAX. = TYP. 0 Ln J N N O J N 8.6" MAX. Ute] o o O.C. TYP. 68 5/8" 5 J o} o MAX. SASH 10 i� g 3 �— HEIGHT 0) o_0 P4 s of a Q D ew = 10>� Z U =0 O e X1/2" O XNZ a 65 1/2" 72 O.A. E., o o �F MAX. D.L.O. FRAME x o v)_ Z �— HEIGHT HEIGHT ��, o o� Z 5 CE)w O ` r a = a 4 F W W Sg!E 40 6 MAX. TYP. J.Amoruso, 31 3/4" MAX 35 7/8 MAX. Robert FL P.E.No.49752 P.E D.L.O. WIDTH SASH WIDTH ;;; ,,, m:�{;aEhaBP,�y SERIES HR 1000S HORIZONTAL ROLLING WINDOW "E = EXTERIOR VIEW °SsdNA�E`�0 Digitally signed by Roberti. Amoruso DN:cn=Robert J.Amoruso,o,-_ ou=PTC Product Design Group, email=robert@ptc-corp.com'r—Us Date:2015.06.1416.38•S4-04'00' m � N EDGE DISTANCE VARIES SEE ANCHOR SUBSTRATE VARIES SCHEDULE SHEET 1 SEE ANCHOR SCHEDULE to INSTALLATION ANCHOR SHEET 1 5/16" O.A. to NOMINAL VARIES SEE ANCHOR 0.090" SAFLEX SCHEDULE SHEET 1 1/8" ANNEALED o MIN. EMBEDMENT VARIES PVB BY EASTMAN a z PERIMETER SEAL SEALANT SEE ANCHOR SCHEDULE CHEMICAL CO. (MA) w BY OTHERS BY OTHERS SHEET 1 EXTERIOR 1/8" ANNEALED FLANGE TO BE 8 g < � SET IN BED OF INTERIOR SEALANT BY OTHERS. 15 1/4" MAX 12 19 to a o SEE NOTE THIS SHEETLO SHIM — o,n 0 1 5 W J cq o M 15 11 10 GO of c� O s J z¢ e 2 3/4" GLASS q vo z g 12 13 BITE 4 00 t! a:GLAZING DETAIL 1 ` � of J Z Z ¢ 19 5/16^NOMINAL LAMINATED E- = I a 5 16 W o� w w� �Xw EXTERIOR INTERIOR " m F 0-t C>o ��(n 8 91/8" ANNEALED "[� O z 5/8" O.A. z = of a of of 2 5 16 19 NOMINAL 0.090" SAFLEX W N 1 a PVB BY EASTMAN E- w a 3c of 1 1/8" ANNEALED CHEMICAL CO. (MA) � USI c s EXTERIOR 1/8" ANNEALED w g€� 15 11 9 INTERIOR FLANGE TO BE SEALANT 13 19 SET IN BED OF BY OTHERS 1/4" MAX. SEALANT BY OTHERS. F SHIM 16 SEE NOTE THIS SHEET 10 PERIMETER SEAL MIN. EMBEDMENT VARIES 3/4" GLASS BY OTHERS SEE ANCHOR SCHEDULE BITE Robert J.Amoroso,P.E. INSTALLATION ANCHOR SHEET 1 SPACER IS A STEEL XL FL P.E.No.49752 VARIES SEE ANCHOR EDGE BY CARDIANL OR : ,- SCHEDULE SHEET 1 DURASEAL BY QUANEX omEP!.ae" oyez GLAZING DETAIL 2 EDGE DISTANCE SUBSTRATE VARIES ;U�;:,4 "� :W; VARIES SEE ANCHOR 5/8"NOMINAL[GU LAMINATED .1< oY:_, SCHEDULE SHEET 1 SEE ANCHOR SCHEDULE —.1" - N�,• SHEET 1 oH��E„ FLANGE NOTE: Digitally signed by Robert J. A VERTICAL CROSS SECTION THE FLANGE IS A NON—STRUCTURAL Amoruso _ Amorus _ PART. IT MAY BE TRIMMED SHORT OR DN:cn=R6bertJ: INSTALLATION o,o, 3 REMOVED ALL TOGETHER DEPENDING ou=UCVroductDesignGroup, ON INSTALLATION REQUIREMENTS. email=robert@ptc-corp.com,c=US D4te:2015.06.14 16:39:09-04'00' i m ,� a 0 LO U LO N a ME 0 0 Q O MIN. EMBEDMENT VARIES MIN. EMBEDMENT VARIES SEE ANCHOR SCHEDULE SEE ANCHOR SCHEDULE SHEET 1 SHEET 1 a 1/4" MAX. 1/4" MAX. SUBSTRATE VARIES SUBSTRATE VARIES a SEE ANCHOR SCHEDULE SHIM SHIM oLO SHEET 1 SEALANT INTERIOR SEALANT SEE ANCHOR SCHEDULE � W o BY OTHERS 9 BY OTHERS SHEET 1 W _j Lr.,, o aJ of o 15 1 15 2 18 19 8 1718 20 � z o qQ z U W F'i R.m N to _, rn 0 ( v) z Z U a =_ o> 19 CW+ C 04 I v o x w o x EDGE DISTANCE EDGE DISTANCE v °'F. opo att VARIES SEE ANCHOR w °. VARIES SEE ANCHOR o a o �3 Fr SCHEDULE SHEET 1 SCHEDULE SHEET 1 z o PERIMETER SEAL d W BY OTHERS 5 13 12 PERIMETER SEAL W "' Ige FLANGE TO BE 16 14 4 11 BY OTHERS SET IN BED OF INSTALLATION ANCHOR 15 INSTALLATION ANCHOR FLANGE TO BE SEALANT BY OTHERS. VARIES SEE ANCHOR VARIES SEE ANCHOR SET IN BED OF SEE NOTE THIS SHEET SCHEDULE SHEET 1 TE EXTERIOR SCHEDULE SHEET 1 SEE NOTE THISLANT BYOSHSRS. _HORIZONTAL CROSS SECTION 4 INSTALLATION FLANGE NOTE: Robert J.Amoruso,P.E. THE FLANGE IS A NON-STRUCTURAL FL P.E.No.49752 PART. IT MAY BE TRIMMED SHORT OR REMOVED ALL TOGETHER DEPENDING A u ;o% ON INSTALLATION REQUIREMENTS. 9: '- STA E OF 'q F9s(OgJ�<y2•� o,�ONA�Ep Digitally signed by Robert J. Amoruso -- DN:cn=Robert).Amoruso.o,- ou=P.TC Product Design Group, email=robert@pt[-corp.com,c=U5 Date:2015.06.1416:3925.04'00' BILL OF MATERIALS 1 3/8" ITEM # PART NUMBER DESCRIPTION MANUFACTURER MATERIAL 3 19/64" 1 GAH-49665 NEW IMPACT HR SILL INDALEX AMERICA, INC. ALUMINUM 6063—T6 3 m 2 GAH-48982 NEW IMPACT SH VENT HEAD INDALEX AMERICA, INC. ALUMINUM 6063—T6 1 37/64" c I � 3 GAS-46856 IMPACT VENT JAMB INDALEX AMERICA, INC. ALUMINUM 6063—T6 T 4 GAH-48984 IMPACT MEETING RAIL INDALEX AMERICA, INC. ALUMINUM 6063—T6 O IMPACT VENT JAMB o 5 GAS-48415 5/16" IMPACT GLAZING BEAD INDALEX AMERICA, INC. ALUMINUM 6063—T6 3 27/64" EXTRUDED ALUMINUM 6063-T6 a o 0.062"THICK IF] nB 6 SERIES 1988 ROLLER ASSEMBLY AMESBURY HARDWARE STEEL a 7 LATCH/LOCK ASSEMBLY g 8 5/16" LAM[ IMPACT GLAZING a IMPACT HR SILL Lo 0 9 5/8" IGU LAMI IMPACT GLAZING EXTRUDED ALUMINUM 6063-T6 w m o 0 0.063"THICK 59 J N 10 SIKAFLEX 552 / SIKA CORPORATION g N STRUCTURAL ADHESIVE GLAZING SILANE—TERMINATED —' � rn F' COMPOUND POLYMER zwo� � w 11 FIN WEATHERSTRIPPING 2 37/64" < a 12 30228 GLAZING VINYL 5/16" GLASS —�— O o—o vi 13 30222 GLAZING VINYL 5/8" GLASS 1 5/I 16" '1 � 2 E e w =�j Z o~ z 14 #8 x 3 1/2" PH SMS MEETING RAIL 2 17 64" U -m TO SILL ASSEMBLY SCREW A / W x �� 15 #8 x 1" PH SMS FRAME ASSEMBLY 5/1� x N x SCREW i s GLAZING �F g�� 16 GAS-48191 5/8" IMPACT GLAZING BEAD INDALEX AMERICA, INC. ALUMINUM 6063—T6 COMPOUND STOP o �? m IMPACT SH VENT HEAD EXTRUDED VINYL 0.085"THICK z of - 17 49652 VENT S.H. VENT SILL INDALEX AMERICA, INC. ALUMINUM 6063—T6 O EXTRUDED ALUMINUM 6063-T6 m o y a 18 #8 x 3/4" PH SMS SASH ASSY 0.062"THICK H w J 5e5 UJ m 19 RP-1009 GLAZING COMPOUND STOP PROTOTYPE PLASTICS VINYL W Ng$� 20 VINYL BULB SEAL VINYL aja� - s 2 3/8" 1 45/64" 1 15/64' 1 15/64" 5/8„ � 5/16" � ' 2 33/64" 2 37/64" 15/16" 15/16 II u Robert J.Amoruso,P.E. 1 17/32" 1 5/8" �9 FL P.E.No.49752 _ "yrere _ �.`e$t�\eMaE.•.gG 5/16" IMPACT �� 5/8 INS IMPACT _ Q VENT S.H.VENT SILL IMPACT MEETING RAIL GLAZING BEAD 16 GLAZING BEAD ''' °° °F 17 O EXTRUDED ALUMINUM 6063-T6 ooFos%%o EXTRUDED ALUMINUM 6063-T6 EXTRUDED ALUMINUM 6063-T6 EXTRUDED ALUMINUM 6063-T6 0.063"THICK 0.062"THICK 0.062"THICK 0.062"THICKstall si g y g y' Di nedb RobertJ. Amoruso DN:cn=RobertJ.Amoruso,o; ou=PTCFroduct Design Group, email='robert@ptc-corp.com,c=US Date:2015.06.14 16:39:39-"00'