HomeMy WebLinkAboutProduct Approval EXTERIOR RESEARCH&DESIGN,LLC.
(-)o Certificate of Authorization#9503
TR���TY I 353 CHRISTIAN STREET,UNIT#13
ERD _�79,E—CEIVEDOXFORD,CT 06478
I (203)262-9245
EVALUATION REPORT «s r MOwens Corning Evaluation Report 037940.02.12-118
One Owens Corning Parkway ST•t.ucie County,Permitting 171-10674-1113Toledo,OH 43659 Y__ Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products de erein have been eva ua compliance with the 6th Edition (2017) Florida Building Code
:;ecti noted herein.
SCRIPTION: Owens Corning Asphalt Roof Shingles
LABELIN hall be in with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,,Florida DCA ANE1983
1i»n,w�7Nieminen,P.E.on 10/09/2017.This does not serve as an
�'•-
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINrry I ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Eq2tl Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 — 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 . 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme®are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire®are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devo4n * inforced,5-tab asphalt roof shingles.
4.1.4 Dura ®, TruDefinition® Duration , ration® Premium Cool, TruDefinition® Duration® Designer Color
Collection, Tr Initb'r-9ak ' ridge® and WeatherGuard® HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgel Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate ofAutharization#9503 61
"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
TRINITY I ERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph•(V„It = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning.hip & ridge shingles, Starter Strip Shingle and. Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up'tO Vasd=150 mph(Vast=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3,and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 . All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlavment:
'6.1.1 Underlayment shall be"acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shinsles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ •Berkshire shingles require minimum five(5)nails per shingle.
➢ WeatherGuard'HP shingles require minimum six(6)nails per shingle.
➢ Devonshire'"'shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Felt underlayment Deck FeRunderhyment Deck Seltadhered
WeatherlackO
ttiff-adhered undedaymem
eatherLocks
undedaymeni
Drip Drip edge DDrip edge
rip—.
edgeedge
Nails located Naas located
2°-3'from cave
Z-3-from cave
Install first Self-sealing adhesive ShcaeaGng edhaSiva
Starter Strip positioned along eave Inste�Drst 5tarter6tdp Plus poatiorrod along eave
shingle with 1 with 6•removed ,.
6"removed Starter Strip shingle overhangs eaves and rakes'/i='/i" Starter Strip Plus overhangs eaves and rakes 1/4"-V4"
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 CH EDITION(2017)FBC NON-HVHZ EVALUATION FL30674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 8
TRINITY I ERD
6.2.6 Minimum Nailing—Classic®&Supreme:
Normal Mansard or Area para Normal Mansard or Area pare
Wind AreaaHigh Wind desvanes y Wind Areas High Wind desvanes y
Area para vlentos normeles Areaa vioatos fuertes Area para vientos normales Areas viontos fuertes
t' IA► z' 1,1 t" lA1 ztt' t' z' lel z' t"
tr n• tzt t
5"Exposure 6 518"Exposure
Exposicf6n Exposicl6n
6.2.7 Minimum Nailing—Berkshire®:
Sealatn strip Sealant strip
La tlra de seBada La tra de selhdor
8Y:" 9Yf 9 Yf 8Yf f ,8 Ye' a Ve" a+h" a;V }
s
r
s
Standard Fastening Pattern 6-Nail Fastening Pattern
SeahN strip
La Pira do sellador
8
Yf 8Yf Yf 8 Y,
1"
r
r Asphalt rooting cement
Comento de techo do astalto
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certificate ofAuthorization 159503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 4 of 8
�jT-RINITYIERD
6.2.8 Minimum Nailing—DevonshireTM':
1:.. 7" 8" 8" 1--81 7
• N
47
aevea
Nails
r c r
5-518°exposure3
Exposielbn de 5"518 pulg Sealant location
Ubiaabn del sellador s>~• _ _ _ ��-
Ten 1°Spots of Asphalt Hoof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, Tru Definition® Duration, Duration® Premium Cool & Tru Definition
Duration Designer Color Collection:
4-Neil Fastening Pattern 6-Nall Fastening Pattern
Su1•NwWastentng a WcKh smHan fast@"=a W=h
Nag,typiral iWi ypiral
14 tr 12" .1^ 1" 1r trL k
1"
�wrn Cnsy lvWu •s �w+�0 • O.m• 1u.1.'i. • Nv^4vfveN+d • !'. i •O�os CasnlvMu•. •
e-ife NLS• 61F� FL18"6d'D^
� F1 F� F�
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
LSUnN11M fntjnnling I I"IM
• -i N.g.ryPIW
1 12- it 1
0.11x"0.L8-
—T2.
Four 1"Spots of IbphNl Rmfing Cement
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118
Certificate ojAuthorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION 01-10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
TRINITY I ERD
6.2.1 Minimum Nailing—TruDefinition•Oakridge®,Oakridge®:
4 Nall Pattem .6 Nall Pattern
Esquema con 4 clavos, Esquema'con 6 clavus
„r r
1. 1•
12-
IF— ,2 ---J►1 I<— ,,2 —s1
6SIG"ExposureNaps 6'6/8"Exposure Naas
Erposiaonde66/8puig: Clavus ExpasWnde6618pulg. 5618"Exposure �e� 66/8"Expowre
Exposielnn de 6518puig. Exposian de S 6/8 ping.
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Stopes Greater Than 21:12
hpic7
suraNNml.stenning ma width
Y 72' / Y 1'
&11T SSf!"
0
Four v spefn of Kephart noonng cement
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
to t =Inpls i1do Vow
i�— .� �� :� I►1eb Trevi!
A
li�tar."-j*1letl lite
flwr re Jleliltaee i f�dfe
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate ofAuthori2ation 119503 6T"EDITION(2017)FBC NOWHVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
TRINITY I ERD
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard• HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgem Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.f 4 Fig.2
t-- PnvAlina wnd
Direction TopMew SideView
A
Nails _Nails
4
I 1 4' Z'
TOP LamUialal r 1
A I I 4' Piece,
4 I I 1
I 1
A I I I I i
W :V �I
I
I
I
I
I
6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
Fig.C Hip&Ridge Shingle Fastening
Fig.A v 4 Top iow
PrevaOby YlltW
E-Dlrectbn p
P
A i i Nalls Nulls
p I T-
.
A I I I l
T T
._E_
Exposure
G. 'Exposure
tri
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certificate ofAuthorizatiion#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL30674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
TRINITY I ERD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard
Wind Direction Fastening
Sealant Strip Pattern
6'Exposure
Sealant
Fasten 711? 71h'
i 6"Exposure
Cover Exposed ISI
Fasteners with
Root Cement 120
6.3.6 Minimum Nailing—DuraRidgeTm Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Proraiing Wind Dirxdcn Top View
'~Dirociondmimnted vwt II- VVlsa�-uperf�or I-
Diroedho do]viento prodxr imnto
f
Cbu
p s Ovrcns Corning SureFlaiP �1O
Claioo\ i�
J L r S1 �I„€
ala$
F �12'-
7.
2 —7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation,of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization 119503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8