HomeMy WebLinkAboutProduct Approval NOTICE OF PRODUCT CERTIFICATION
C
CERTIFICATION NO: N1010656.01-RI
Ao 0
DATE: 05/24/2011
CERTIFICATION PROGRAM: Structural
COMPANY: Eastern
CODE: 1783-1
REVISION DATE: 06/16/2014
# Mk,�Fvx,r_its
To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the
product is active and currently listed.This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. ANAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAM if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
Eastern Architectural Systems Series"2466" Vinyl
10030 Bavaria Road Impact Fixed Window
Ft.Myers,FL 33913 Configuration:o
Glazing:IG-3/16"Annealed Glass/
Laminate-3/16"Annealed Glass/0.075"Sea Storm
Solutia/3/16"Annealed Glass
Frame: W-1626mm(64") H 2134mm(84")
DLO: W-1495mm(58.88") H-2003mm(78.88")
SPECIFICATION PRODUCT RATING
AAMA/WDMA/CSA 101/I.S.2/A440-05 FW-C801626 x 2134(64 x 84)
Product Tested By:Architectural Testing,Inc.
ReportNo: 68099.03-701-47
Expiration Date: September 30,2019
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes,VA 23072
Tel! (804)684-5124
Fax: (804)684-5122
i
NOTICE OF PRODUCT CERTIFICATION
k
x � FIT10
Gip ;
Quo ��u,scc��ror -off CERTIFICATION NO: NI010610.01-R1
x` DATE: 05/09/2011
4t ,�Mj CERTIFICATION PROGRAM: Structural
COMPANY: Eastern
�t..-
#, ►,�, r4_ ,_ CODE: 1783-1
oah r. REVISION DATE: 04/26/2015
To verify that the"Notice ofProduct Certification"is valid,please visit www.NAMICertification.com to assure that the
product is active and currently listed.This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAN R approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
'COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
Eastern Architectural Systems Series 112466"Impact Rated
10030 Bavaria Road Vinyl Fixed Window
Ft Myers,FL 33913 w/Flange Frame
Configuration:O
Glazing:IG-3/16"Annealed Glass/
Laminate-3/16"Annealed Glass/0.075"Solutia Sea Storms
interlayer/3/16"Annealed Glass
Frame: W-1626mm(64") H-2134mm(84")
DLO: W-1486mm(58J) H-2007mm(W')
I
SPECIFICATION PRODUCT RATING .
ASTM E1886-02AE1996-02 Design Pressure: +60%60 psf
Wind Zone 4-Missile Level D
Product Tested By: Certified Testing Laboratories.
Report No: CTLA-2062W-5
Expiration Date: June 30,2020
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE,INC.
4794 George Washington Memorial Highway
Hayes,VA 23072
Tel: (804)684-5124
Fag: (804)684-5122
i
EDGE DISTANCE v .. .. E s6vs
BY OTHERS -•• •,. ,. .. 6 MMUF LTURO S WM .. OVC ace�o+m
aLscwanmt
CONCRETE/MASONRY - ALTURfRS NMt CHANGE 03f03/49 Rd.
it ° TEED PER NEW CERnnCAT10N 06/26/14 R.L
° ° a 1 7/4 MIN. C REUSED WSTAWTtON MIARS O6/22/S6 RL
EMBEDMENT
OPTIONAL 1X BUCK . °' 1 1/4`MIN.
SEE NOTES 3-7 SHEET 1 r EMBEDMENT
� CONCRETE/MASONRY
By OTHERS
SEALANT 1/4ROVED 'MAX. OPTIONAL TX BUCK1SAC
SHIM SPACE SEE NOTES 3-7 SHEET 1 r• SHIM SPACE
:r
3/16'TAPCON 3/16'TAPCON
INTERIOR
ems,
2 1/2'
EXTERIOR 1NTERIOR MIN'
EDGE '
D15TANCE '=
r EXTERIOR
• APPROVED
SEALANT
JAMB INSTALLATION DETAIL
CONGRET&MASONRYTHSTALJATTOM
APPROVED 3/16`TAPCON
SEALANT NOTES.
1/4'MAX. i.WTERI0RANDVaERI0RFVA9h S,BYOTHM
OPTIONAL 7X BUCK SHIM SPACE N PERIACMRANDJARRY.
SEE NOTES 3-7 SHEET 1 O 2PERtNE LV ANDJDAAICELANTBYOTZIIZ SE
DESIONEDWACGORMNOEW/THASTM 62172
CONCRETE/MASONRY ---�
SIGNED:06232015
BY OTHERS a 1 7/4'MIN. r
EMBEDMENT 1ESS+T�I`/l `�\��`�gtiR
`may
2 1/2'69N 2466 PICTURE WINDOW64 x 84
EDGE C
*• 0 6
VERTICAL CROSS SECTION E INSTALLATION DETAILSTAT of {4�`
CONCAE7'�'MALJAMN DiuRrt O rro. tav '•�1DRlOT:•+,'{�
A-M1KTL7/29/03
oe-oD5s5 C ��i�sSlpNAi��60�
NTS 7 29/08 19W4 OF 4
j
1/2"MIN, aE\t +s
EDGE DISTANCE METAL �v tiME
3J4"MIN. —
WOOD FRAMING EDGE DISTANCE A NANUFACTURER'S NAME CHANGE03/03/04 P.L.
B UPDATED PER NEW ORS 2X BUCK STRUCTURE C RLVSED tNSTALUR —CATION 06/26/14 RL
CERTIP _
BY OTHERS 1 1/4"MIN. BY OTHERS ON OETAILS 06/22/15 R.G
EMBEDMENT
tf4"MAX.
I r SHIM SPACE
APPROVED 1/4•MAX APPROVED 1/4"MAX. INTERIOR
SEALANT SHIM SPACE S£AtANT SHIM SPACE 3/4•MW.
EDGE DISTANCE
X10 WOOD
SCREW X10 SMS OR
SELF DRILLING �10 SMS OR
SCREW SELF DRILLING
SCREWS
METAL
STRUCTURE
BY OTHERS APPROVED EXTERIOR
SEALANT
_ EXTERIOR INTERIOR JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
1 1/4.?AIN. 1/4"MAX,
EXTERIOR INTERIOR EMBEDMENT SHIM SPACE
1/2"MIN.
EDGE DISTANCE
INTERIOR
010 WOOD #10 SMS OR #10 WOOD
SCREW SELF DRILLING SCREW
SCREW
PROVED _ APPROVED WOOD
FRAMING
SEALANT 1/4 MAX. SEALANT EXTERIOR
SHIM SPACE 1/4•MAX. OR 2X BUCK
—C SHIM SPACE BY OTHERS
APPROWOOD FRAMING —� ME!"AL SEALANTS
OR12X BUCK I I/4"MIN. STRUCTURE
BY OTHERS EMBEDMENT BY OTHERS JAMB INSTALLATIONDETAIL
WOOD FRAMW G OR 2X 8 UCK INSTAL LAT KIN
6
i j2"MM. EDGE DISTANCE 4'MIN SIGNED:O6I2312Qf5
EDGE DISTANCE �' East$rnm+ \��11j1R'Itpff///
VERTICAL CROSS SEC77ON VERTICAL CROSS SECTION , �.`�v`�cElvs 9s�l
WOODFRAMtNGORVEUCKWSTALtATM METALSTRUGWREINSTALLAAON ^'"�'v"""�+um \r
NOTES., _ 2466 PICTURE WINDOW *• 0 6 #^
1.LVTERIORAND EXTERIOR FWLSHES,SYOTNERS LA O 84 ro�
NOTS140WNFLIRCLARTTY. INSTALLATION DETAILS. y7, TAT OF
2.PERIMETERANDJOIM'SEALAM'BYOTNERSTOSE pmt me xo. rst i([S:t'lORlnA tm�
DESIONEDINACCOROANCEW TM
IMASE2112 p,M 08-00565
NTS ImE 7/29/08 �3 OF 4 J�tII111�����
I
i
I
RM90t6
All-
T� TWE
64'MAX FRAME WIDTH
A WNTUFACTURDYS NAME CHANCE 03/03/09 RL
6"MAX. 10 1/2" 6"MAX. B UPDATED PER NEW CERTIFICATION 06/26/14 R.L.
MAX. O.C. C REVISED INSTAWTION DETAILS 06/22/15 RL
6'MAX.
9"MAX.O.C.
3/16"ANN
.075"SEASTORM BY EASTMAN
3/16'ANN '� 3/16"ANN
\\ 84" SIKAFLEX 552
7B
MAXFRAME
MAX ALUMINUM
D-LO. HEIGHT .._ BOX SPACER
1/2'SITE
SETTING BLOCK
GLAZING DETAIL
6"MAX.
II
58 7/8"MAX. D.L.O.---.�
2466 PICTURE WINDOW
EXTERIOR VIEW
DESIGNPRE&WREWNG WPACTRAflNG SIGNED:06232015
360.OPSF A
LMRGEEDSMAL Eastern
WILE SIdelr i�i1
D
wn'urtaynaio"vm `�,�y�OEAIg 9J+
WPACT
2466 PICTURE WINDOW
64 x 84
ELEVATION AND GLAZING DETAIL TE OF Z
��• A tV�
owax TMGxa r+tv <OR10Q:-�'��.
29 OB 08-00565 4 G NAL
—NTS —7
I
R_lv9@6
Ar
A NANUFACRIRER'S NAME CHANGE 03/03/09 R.L.
9 UPDATED PER NEW CERRFlCATION 06/26/14 R.L.
C REVISED INSTALLATION DETAILS 06/22/15 R.L.
NOTES: 15.FOR ANCHORING INTO MASONRY/CONCRETE USE 3/1V TAPCONS WITH SUFFICIENT LENGTH
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDING CODE TO ACHIEVE A 1 1/4'MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2"MINIMUM EDGE 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
TRANSFER ALL LOADS TO STRUCTURE.FRAMING AND MASONRY OPENING IS THE 16.FOR ANCHORING INTO METAL STRUCTURE USE 010 SMS OR SELF DRILLING SCREWS WITH
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2'WINDOW UNITS MUST BE 17.ALL FASTENERS TO BE CORROSION RESISTANT.
1B.INSTALLATION ANCHORS SHALL BE INSTALLED W ACCORDANCE WITH ANCHOR
ANCHORED THROUGH THE FRAME W ACCORDANCE WITH MANUFACTURER'S PUBLISHED MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
INSTALLATION INSTRUCTIONS.ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
MASONRY,CONCRETE OP.OTHER STRUCTURAL SUBSTRATE MATERIAL. A WOOD- MINIMUM SPECIFIC GRAVITY OF G-0.42
S. WHERE WOOD BUCK THICKNESS IS 1-1/2'OR GFEATER, BUCK SHALL BE SECURELY B. CONCRETE-MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI.
FASTENED TO MASONRY,CONCRETE OR OTHER STRUCTURAL SUBSTRATE WINDOW UNITS MAY C.MASONRY-STRENGTH CONFORMANCE TO ASTM C-90,GRADE N.TYPE 1 (OR GREATER).
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE LYITH D. METAL STRUCTURE: STEEL 18GA,33KS1 OR ALUMINUM 6063-T5 1/8•THICK MINIMUM
MANUFACTURER'S PUBUSHEO INSTALLATION INSTRUCTIONS. 19.UNITS MAY BE INSTALLED WITH OR WITHOUT ADD-ON FLANGE.
6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF
THE ARCHITECT OR ENGINEER OF RECORD.
7. RUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT
EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16'OR
GREATER OCCURS. MAXIMUM ALLOYIABLE SHIM STACK TO BE 1/4•.
9. SHIMS SHALL BE LOCATED,APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS.
10.WIND LOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
11.FRAME MATERIAL EXTRUDED RIGID PVC.
12.UNITS MUST BE GLAZED PER ASTM E1300-04.
13.APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS.
14.FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE#10 WOOD SCREWS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4•MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE"
ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
SIGNED:06/232015
w". Eastern ums.�.uma, \�011!I111'l,wmPmmvy
TABLE OF CONTENTS 2466 PICTURE WINDOW *•
SHEET N0. DESCRIPTION 64 x 84 _,o;//,y, 6 •*-
NOTES =TA• TAT OF•Awa
1 NOTES O
2 ELEVATIONA.m ° ■a aLv oa =�CORIOP
J - 4 INSTALLATION DETAILS z�LE NTS WE 7/29/08 s+aT 65rs6
0E 4 C ���f%0NA11EN
AIL
I
L. Roberto Lomas P.E. Engineering Evaluation Report
233 W.Main St.
Danville,VA 24541 Report No.: 510954B
434-688-0609
Manufacturer: Eastern Architectural Systems
16341 Domestic Ave
FT Myers,FL 33912
Product Line: 2466 Picture Window
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a).The product listed
herein complies with requirements of the Florida Building Code.
Supporting Technical Documentation:
1. Approval document:drawing number 08-00565 revision C,prepared,signed and seated by Luis Roberto Lomas
P.E.
2. Test Report No.:CTLA-2062W-5 signed and sealed by Ramesh Patel, P.E.
Certified Testing Laboratories,Orlando,FL.
ASTM E1886-02 and ASTM El 996-02
ASTM E1886/E1996 Large Missile Impact Test,Level D,Wind Zone 4
ASTM E1886/E1996 Cyclic Load Test,160.0 psf design pressure
3. Test Report No.:ATI 68099.03-701-47 signed by Michael L.Mackereth
Architectural Testing,York, PA
AAMANVDMAICSA 101/i.S.2/A440-05
Design pressure: ±80.Opsf
Water penetration resistance 12.Opsf
4. Anchor calculations, report number 510954, prepared,signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use.
• Maximum design pressure: ±60.0psf
• Maximum unit size: 6411 x 84"
• Units must be glazed per ASTM E 1300-04. See installation instructions for details.
• This product is not rated to be used in the HVHZ.
This product is impact resistant and does not require impact protection in wind borne debris regions.
• PVC profiles certified by AAMA Deceunick North America DEP-1 and VBP-2
installation: Units must be installed in accordance with approval document,08-00565 revision C.
Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company
manufacturing or distributing the product(s)for which this report is being issued.Also,I don't have nor will acquire a
financial interest in any other entity involved in the approval process of the listed product(s).
`,`���RI! Z
0
N
NN
40 51
- TAT OF
%,���:��0RVDV-
ONAL
I of 1 Luis R.Lomas,P.E.
FL No.:62514
06/2212015
SAFLEXO CP drawing page 2 of 2
Material Desighation Smoke Density Rating Dade
per ASTM D 2843 Notification#
-Saflex@ Colorants
Safle)o—Clear 61,1 ETC03024
saflexe—White 62.6 ETC03023
SaflexO—Black 68.1 ETC03013
SaflexO—Blue 50.6 ETC03026
saflexe—Yellow 59.6 ETC03016
SaflexO I-Red 60.8 ETC03016
Saflex(D—metaille 60.0 ETC03014
Note(q.
Saflex*StormIV802 was also known as VancevaO Storrn/VS02 prior to the brand name change 09/12108.
Vanceva 81ormlV802was referenced on the Vanceva Composites NOA 08-0620.08 expiring 12111113.
Wallex and Vanceva are registered trademarks of Solutia Inc.
This is a component approval and does not Include an evaluation of structural performance of this component.
Systems Incorporating this component shall apply for an NOA with Miaml-Dade County Product Control and submit
test reports and other documents showing that the systems using this componentwill resist the loads according to
Chapter 16 of the Florida Building Code.
PRODUCI MV101)
73
thstAVftPt6nCG NO
1 U- 3".
jLtj
Eastman Chemical Company
730 Worcester Street,Springfield,MA 01161
1202 Phone:413-730-3413;FAX 608-861-0127
WARREN '0 R,i�E__
87RU ORMENG)HEER "I"Ift SafiexO C13-Intorlayere for Laminated Glass
nms
NO.44135
Drawing No. Drawn by. Drawing Date sheet No.
W.W.SCIMEE01 N E-9 f OHO&CONSU LM HO PUAI 20F2
W"'n Ila Elm ITM
1816 04106112
pAXP.j DOW GAFWEH%FL3M13
MIAMISMM MIAl 11-DADS COUNTY
uMW
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECON01-V1IC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidad&gav/economy
Eastman Chemical Company(MA)
730 Worcester Street
Springfield,MA 01151
SCOPE:
This NOA is being issued under the applicable rates and regulations governing.the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County ICER Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In
Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined
by Miami-Dade.County Product Control Section that this product or4material fails to meet the requirements of the -
applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Saflex CP—Saflex and Saflex HP Composite Glass Interlayers with PET Core
APPROVAL DOCUMENT:Drawing No. 1815,titled"Saflex CP Interlayers for Laminated Glass,"Sheets
1 and 2 of 2,dated 04/06/2012,prepared by W.W.Schaefer Engineering&Consulting,P.A.,signed and
sealed by Warren W.Schaefer,P.E.,bearing the Miami-Dade County Product Control revision stamp with
the Notice.of Acceptance number and expiration date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING:None
LABELING:Glass laminated under this Product Approval shall be permanently marked in a corner of the
glass with:a)Saflex CP,b)Authorized laminator's name,c)M.D.C.A.that stands for Miami Dade County
Approved and d)Markings required by federal law for safety glazing.
LIMITATION:This approval does not include an evaluation ofstructural performance of this
component.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building Bode negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA-
ADVERTISEMENT:
OA.ADVERTISEM ENT: The NOA number preceded by the words Miami Dade County,Florida,and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the pser by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#12-1231.08 and consists of this page 1 and evidence page E-1,as well as approval
document mentioned above.
The submitted documentation was reviewed by Carlos M.IItrera,P.E.
NOA No. 14-0423.15
!� Expiration Date:December 11,2018
MIAM!•DAD;COUlV71f Approval Date:June 19,2014
.'t L Z�f4 Page 1
:f �t
.4
�1
i,.
' I
Eastman Chemical Cownanv(MA)
I -
1
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A.' DRAWINGS "Subinitted under NOA#12-1231.08"
1. Drawing No.1815,titled"Saflex CP Interlayers for Laminated Glass,"Sheets 1 and 2 of 2,
dated 04/06/2012,prepared by W.W.Schaefer Engineering&Consulting,P.A.,signed and
sealed by Warren W.Schaefer,P.E. '
B. TESTS "Submitted under NOA 9 03-0415.13"
Laboratary Test Date Signature
1. Omega 15542-110291 ASTM E 84 02/26/03 J.W.Dougherty,P.E.
2. Omega 15542-110291 ASTM E 84 02/26/03 J.W.Doughert)6 P.E.
4. ETC 03-191-13090.0 , ASTM D 1929 02/10/03 J.L.Doldan,P.E.
5. ETC 03-191-13090.0` ASTM D 635 02/10/03 J.L.Doldan,P.E.
6. ETC 03-191-13090.0 ASTM D 2843 02/10/03 J.L.Doldan,P.E.
7. ETC 01-726-11271.0 ASTM C-158 10/15/01 J.L.Doldan,P.E.
8. ETC 03-191-13748.0 ASTM D 2843 07/25/03 J.L.Doldan,P.E.
1
C.' CALCULATIONS
1. None.
D. .QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources(RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to 2010 and 50'edition(2014)FBC issued by W.W.
Schaefer Engineering&Consulting,P.A.,dated 04/10/2014,signed and sealed by Warren W.
Schaefer,P.E.
"Submitted under NOA 0121231.08"
2. Sales of assets letter issued by Eastman Chemical Company,dated 12/06/2012,signed by
Edwin Williamson.
"Stcbmitled under NOA#11-1102,09"
3. No financial interest letter issued by W. W.Schaefer Engineering&Consulting,P.A.,
on 10/24/2011,signed and sealed by Warren W..Schaefer;P.E.
Carlos M.Utrera,-P.E.
Product Control Examiner
NOA No.14-0423.15
Expiration Date:December 11,2018
Approval Date:June 19,2014
E-1
{
I
MtOOUCr Rf3Yi91-D
Saflex@ CP ptr.lfo A �
A BCB A Product Description ' > lrt
Manufactured By: Eastman Chemical Company
Degeription: Saflex@ CP is a combination of clear or colored
plasticized polyvinyl butryal interlayers with a clear polyethylene
teraphthalate(PET)core for lamination between two or more lites
of glass. Atypical glazing is made of the following components
(minimum thicknesses Indicated-multlple layers of Interlayer to
be used as necessary):
A-2,3 mm 0.030-1n) Annealed Glass
B—0.7.0 mm (0.0304n) Sailer or SWI-eW RP
ititerlayers(Clear or Colored)
SECTION C 0.05 mm(0.0024n) Polyethylene teraphthalate(PET)
Product Properties
Desorlption Test PVB&PET Compoeltes(2)
(1)Flame Spread index ASTM E84 66 AisvlSSQ '
(1)Smoke Develop Index ASTM E84 354°F � ��F
(1)Self Ignition Temp ASTM DIM 664°F t'bOri
(1)Avg,Time of Burning ASTM D636 1.52 min.92 A Ab .
(1)Avg.Extent of Burning ASTM D635 2.9t3Inches
(1)Smoke Density ASTM 2843 54.9% ,
(M)Avg Mod of Rupture ASTM C168 Weathering(3)
(1)Spectmen.Laminated glass with Saftexe CP lype intartayer
(2)Seflaxe CP type interlayer by Itself(unprotected)does HOT comply%Wlh Florida Building Code.
(3)Weathering per section 2812 of the Florida Building Code
'(t3efore MR=3901.671 psi;After MR=3697.184 psi Delta 7.8%)
Saffexe CP type interiayam are currently provided or SaHax Secure,Saffex Solar,Sailex Storm,Safiex V342,Saffex VSR6 and Vanceva
pure white.
Safiex CP type fntetiayars have also been known as Vancava V802,Vanceva Storm and Vancava Composites. 'these name are obsolete
and should no longer be used io reference to this product.
asaftex is a trademark of Eastman Chemical Company
This is a component approval and does not include an evaluation of structural performance of this component. Systems incorporating two
component shall apply for an NOA to the Miami Dads Product Control and shalt submit last reports and other required documents sholving
that the systems using this component win roalsi the foods according to chapter 16 of the F.B.C.A list of authorized laminators shall be tiled
With Miami-Dade County by Eastman Chemlcni Company
CHANGED FOR LAGUL CL WROATION OflOBif2
Al CHM0111O1`1160UCTWMETOSAFLEX. 09112ma
REV.ODESGRIPRON DATE
Eastman Chemical Company
l~C 112012 730 Worcester Street,Springfield,MA 01151
'c - :. Phone:413-730-3413,.FAX608-861-0127
`s i WARREN ,.$ gFER,P.E."
Titie:SaflexG CP fnterlayers for Laminated Mass
t,• 'i.: -, ,,�.' Drawing No. brawn by: Drawing Date Sheet No.
vlivi+liart niwo +suii i Nara 181$ 04106/12 1OF2
• r�eo rr+rcouxret�aartr
PAL170EACHOARDffr8,FL3Wrd
PtjD.1'E:6813ti^342f
I