HomeMy WebLinkAboutWind Load Calculation - RECEIVED
AUG 2 8 2018
HURRICANE SHUTTERS, INC. ST. Lucie County, Permitting
PANELS • ACCORDIONS • BAHAMAS
COLONIALS • ROLL UPS
Property Information I F Building Information
Owner: Fidaho LLC Wind Zone: 170 MPH.
Address: 1531 NW Buttonbush Cir Exposure Category: B
Palm City,FL 34990 Minimum Building Dimension: 5 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening LocationIF—Device Device Device Max Positive Max Negative
--][Number Zone Width(in) Height(in) Elevation(ft) Pressure(psfl JFPressure(psf)
1 Int 55 120 7 28.1 -30.7
2 Int 156 120 7 26.0 -28.6
3 Int 218 130 7 25.1 -27.8
4 Int 150 120 7 26.1 -28.7
17-ILE COPY
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1
Identification Schedule for Opening Protective Device or System
(The following mininunn hiforn:ation shall be provided to facilitate plan review and inspection of the proposed i►rstallation,opening,protective device or system)
Address: 1531 NW Buttonbush Cir, Palm City, FL 34990 Type of Structure: PERMIT#:
Dev. Device Device ApprovalOpening Opening Shutter Shutter #Storm Anchor Header
# Type Manufacturer Width Height Width Height Bars Reg. Spacing Reinf.Re
1. Roll Down ASSA FBC 55 120 55 120 10" No
2. Roll Down ASSA FBC 156 120 156 120 10" No
3. Roll Down ASSA FBC 210 120 218 130 10" No
4. Roll Down ASSA FBC 150 120 150 120 10" No
C
LU a
LU 3 ' .
a
W
tY Q U