Loading...
HomeMy WebLinkAboutRevisions OFFICE USE ONLY: DATE FILED: !- �- 1 p PERMIT# L( " , I Off/O ✓��� REVISION FEE: O RECEIPT# PLANNING&DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION RECEIVED 2300 VIRGINIA AVENUE FORT PIERCE,FL 34982-5652 (772)462-1553 SEP 0 4 2 018 APPLICATION FOR BUILDING PERMIT REVISIO ST. Lucie County, PMrmitting PROJECT INFORMATION LOCATION/SITE ADDRESS: i Cava l n6 06�» or I�GI`e DETAILED DESCRIPTION OF PROJECT REVISIONS: ' otapumen- bLA, � CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST.LUCIE CO CERT. #: BUSINESS NAME: Ifs QUALIFIERS NAME: \ Or lY10.11` ADDRESS: J I_ _ n C CITY: STATE: ( ZIP: PHONE(DAYTIME):'-7 7,2 C9 Q I-5Z 3) (,0 FAX: OWNER/BUILDER INFORMATION: NAME: n n e� Q) N r ADDRESS- ®O CITY: STATE: ZIP: 3 PHONE(DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE(DAYTIME): FAX: SLCCC: 9/23/09 Revised 06/30/17 I RECEIVED SEP 04 2018 ST. Lucie County, Fol"ri`ilt>;ing MEMO etc. Certificate of Authorization#3245S s 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY 6 1 . •S• g 6 Soprema,Inc. Evaluation Report 518010.06.09-R12 1640 rue Haggerty FL2569-R14 Drummondville,QudbeCJ2C 5138 Canada Date of Issuance:06/15/2009 (819)478-2400 Revision 12:02/12/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been.reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the eb Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.of any changes to the product(s),the Quality Assurance or the production facility location(s). NEMOIetc.requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOJetc. Evaluated" may be displayed In advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done In Its entirety. G INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized byRobert Florida Registration No.59166 Florida DCA ANE1983. W, :• Nieminen•P an 02/121201$.This does not serve as an <,,�a roua4,.tT. n�" electronically signed document. CERTIFICATION OF INDEPENDENCE: i 1. NEW ETC.LLC does not have,nor does it intend to acquire or will it acquire,a financial interest In any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nleminen,P.E.does not have nor will acquire,a financial interest In any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved In the approval'process of the product. 5. This is a building code evaluation. Neither NEW Ietc.nor Robert Nieminen,P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,Is/was used for permitting or design guidance unless retained , specifically for that purpose. E OMEMO etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments,as produced by Soprema,have demonstrated compliance with the following sections of the 61'Edition (2017)Florida Building Code through testing In accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. TANDARDS: Section Pr eStandard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering ASTM 04798 2011 Entity Examination " `'` 'Reference'` ' `: :`:' ;'Date ERD(TST6049) ASTM V1970/TAS 110 2968.05.04-2 05/14/2004 ERD(TST6049) Physical Properties 2757.02.05 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) Wind Resistance 2779.11.05-R1 04/18/2007 ERD(TST6049) TA51D3/TAS 110 57120.11.07-2 11/02/2007 ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-113 04/01/2010 ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-111 09/0912010 ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.09-112 10/05/2010 ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011 ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 - 04/17/2015 ERD(7576049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015 ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017 PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL,LLC(QUA9625) Quality Control Service Confirmation Exp.07/18/2020 eD 4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, S8S modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). 4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modffied bitumen roof underlayment available in two widths;36 and 45 inch;meets ASTM D1970. 4.3 RESISTO SA SMOOTH PLY 40 Is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment;available in 3.3 ft x 65 ft rolls;meets ASTM D1970. 4.4 Lastobond Shield HT is a self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof underlayment;meets ASTM D1970. NEMO ETC,LLC Evaluation Report 518010.06.09-R12 Certrykate afAuthorlradon#32455 6TM EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-1134 Soprema Roof Underlayments ReVlslon 12:02/12/2018 Page 2 of 9 8 t , ONEMOletc. 4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch;meets ASTM 01970. 4.6 Lastobond Pro HT-S is a self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof underlayment;meets ASTM D1970. 4.7 EnviroShield is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment;meets ASTM 01970. 4.8 Lastobond 195 Is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment; meets ASTM D1970. 5 4.9 Lastobond Eaves Protection Sheet Is a self-adhering,glass-mat reinforced, sand-surfaced,SBS modified bitumen roof underlayment;meets ASTM D1970. 4,10 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced,SBS modified bitumen roof underlayment; meets ASTM D1970. 4.11 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 412`'�-RESISTO1B1236-is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified_ bitumen-roof underlayment, with a 36-inch sheet width;meets ASTM D1970. 4.13 PrimeSource Grip-Rite Eave & Valley Protector Is a self-adhering, glass-mat reinforced, sand-surfaced, SBS I modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970. 4.14 RESISTO L91244 Is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment, with a 44-inch sheet width;meets ASTM D1970. 4.15 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12)• 5.1 This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nleminen,P.E.are,In any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting E or design guidance unless retained specifically for that purpose. 5,2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 4 5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product Is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: •.. • •• . . . ...... .....: ,,. Asphalt Nall!On ..; . Foam-On 'Composlte .': Slate or :. Uerlayment : Metal -Sh Composite hakes nd shtngtes Slate obond TU H La t T - ---r,l7ies�V�>-�:-• -C- ''n-��� =sites==�=:=� �-esu=�:_., Lastoband Shield �" `- _= RESISTO SA SMOOTH PLY 40/ �, , - yes Yes Lastobond Shield HT/Pro HT-5 Enviro5h.eld •___....J.- ::::::tet� - •. j wing= : z� NEMO ETC,LLC Evaluation Report 518010.06.09-R12 Certfflc•teaJAOEhortrot7anN32455 6'"EDITION(2(117)FOC NON-HVH2 EVALUATION F1.2569-1114 Soprema Roof Underlayments Revision 12t 02/12/2018 Page 3 of 8 ONEmojetc. TA13LE 1- ROOF COVER.OPTIONS -Wood .:.. .. Slate or Underia ment "'Asphalt ' °Nall=On Foam-On'*:,*" . == 'Composite Y Metal Composite Shingles Tile..-• Tile_ :• :•.• Shakes& Slate I :. Shingles : . - -LastobondEavesProtection Sheet/ - - - - Lastobond 95 - - - - ....r... ..moi... Lastobond ECO /RESISTO 181236 Grip-Rite Eave&ValleProtector RESISTO LB1244 Lastobond Smooth Seal HT - - - ,;Yes_ ': - -Colphene - FR GR - - NOR--- OWN - - `-y s=`=� - - = - 5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations. TABLE ' • •. . e Adhesive Florida Product Approval-; • .. :...:Underlayments Dow TileBond- FL22525 Lastobond TU HT ICP Adhesives Polysete AH-160 FL6332 Lastobond TU HT or Colphene FR GR 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S, EnviroShleld, Lastobond TU.HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO,RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastabond Smooth Seal HT applied to: Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed 058;southern Yellow Pine;ASTM D41 primed F Southern Yellow Pine;ASTM D41 primed structural concrete. Colphene FR GR applied to: Y Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. Note: l ➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocoi Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. Y Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment, 5.6.2 Bond-to-Insulation: Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S, EnvlroShietd, Lastobond TU-HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite-Eave &Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board. For Installation under mechanically attached prepared roof coverings,insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's-Product Approval. For installations under foam-on the systems(Lastobond TU HT only),insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D, Testing Application Standard TAS 114,Appendix J or UL1807. Refer to Me Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,LLC Evaluation Report S38010.06.09-R12 Certykate ofAuthorkation#32455 6T EDMON(2017)FOC NON-HVHZ EVALUATION F12569-R14 Soprema Roof Underleyments Revhlon 12:02/12/2018 Page 4 of 8 i s E F a i fONEMOJetc. 5.6.3 Bond to Mechanically Attached Base Laver: Lastobond Shield, Lastobond Pro HT-1V, RESISTO SA SMOOTH PLY.40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236; Grip-Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. For installations under mechanically attached prepared roof coverings,base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems(Lastobond TU HT only),base layer shall be attached in accordance with FRSA/TRI April 2012(04-12). 5.6.4 Wind Resistance for Underlayment Systems In Foam-On Tile Applications: FRSA/TRI April 2012(04-12)does not address wind uplift resistance of all. underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12)'and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure=-45.0 psf: 7 Deck: Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. 02 Maximum Design Pressure=-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. r #3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional)RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self-adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end- laps. #4 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5,2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c.in three(3),equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered 5.6.4.1 All other direct-deck,adhered Soprema underlayment systems beneath foam-on tile systems carry a Maximum Design Pressure of-45 psf. NEW ETC,LLC Evaluation Report S19010,06.09.1112 Certflcote of Avthorkation 83MS (P EDITION(20171 FBC NON.HVHZ EVAWATION FL2569-R14 Soprema Roof Underiayments Revision 12:02/12/2018 c Page 5 of B 0 e ONEMO I etc. 5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,RESISTO LB1Z36, Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not'be left exposed for longer than 30-days after installation. Lastoband Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT or Lastobond Pro HT- S, TS,EnviroShleld shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than*180-days after Installation. 5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12))• When loading roof tiles on the underlayment in direct-deck We assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. r • r I Underlayment. Tile Profile .- Staging Method Maximum slope Flat Max.10-tile stack 6:12 Lugged Max.10-tile stack 5:12 Max.1041le stack(bottom 2-tile stack shall be Inverted,followed by 8 tiles high 6:12 on slope,as shown below) rg� ���-�=may: _-• ti' I Lastobond 7U H7 : •�=•=`•:. . Lugged - I I I I i . I I Colphene FR GR Flat Max.10-tile stack 5:12 Lugged Max.10-tile stack 6:12 3 NEW ETC,LLC Evaluation Report S18010.0649-R32 CertfftteofAuthorlrotibn#3245s EDITION(2017)FSC NOIMVH2 EVALUATION FL2569-R14 Soprema Roof Underlayments Revision 12:02/12/2018 Page 6 of 8 INNEMOletc. ) INS • t 6.1 Soprema Roof Underlayments shall be Installed In accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER(if applicable). 6.3 Lastoba.[td: U:HT .Lastobond.Shleld;: ;3sto...... J o:f YrN, RESISTO-$A.SMOOTH PLY.40,:Lastobond.Shield HT, s :.- _ Lastobond Pro HT-S,EnviroShieid,Lastobond.Eaves.Prptectiop.Sheet,Lastobond 195,.1astobond Eco,Lastobond Smooth Seal HT,RESISTO LB1236,'Grlp Att¢,Eaye:&Va{ley.Protector RESISTO t81244 or Colphene FR GR: 6.3.1 Shall be installed in compliance with the requirements for ASTM 01970 underlayment in FBC Table 1507.1.1 for. I the type of prepared roof covering to be installed. 6.3.2 Non-rife Applications: While priming is optional,Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for Installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place,peel-off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches,configured to shed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12, Soprema recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet over a valley or ridge.Drape and press sheet into place,working from the center of the valley or ridge In each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applicatlons(Lastobond TU HT or Coiphene FR GR only),: Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted above as a guideline. For foam-on the applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See i Table 2 herein,and Soprema published requirements for the staging. • • As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of p this product. l NEMO ETC,LLC Evaluation Report 518010.06.09-R12 [erdfkate o/Authurhallon#32455 EDMON(2017)FBC NON•HVHZ EVALUATION FL2569-R14 Soprema Roof Underlayments Revision 12:02112/2018 Page 7 of 8 a ONEMOjetc. 8. MANUFACTURINP PLANTS- Contact the noted QA agency for information on product locations covered for F.A.C. 61620.3 QA requirements. The following plants have qualified products under their respective physical properties specifications. plant . . :. Specification :..:::. :::::..::::'.;::': ` ra educt{s} Lastobond Shield,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Drummondville, Lastobond Pro HT-N,Lastobond Pro HT-S,EnvlroShield,Lastobond 195, QC{Canada} ASTM D1970 Lastobond Eaves Protection Sheet,Lastobond Eco,Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley Protector,RESISTO L81244 A5TM D1970&FRSA/TRI 04-12 Colphene FR GR Wadsworth,OH Lastobond-195,Lastobond Eaves Protection Sheet,Lastobond Eco, ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley Protector,RESISTO LB1244 ASTM D1970&FRSAJTRi 04-12 Lastobond TU HT;Coiphene FR GR Gulfport,MS Lastabond 195,Lastobond Eaves Protection Sheet,Lastobond Eco, ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley Protector,RESISTO L01244 * , UL,LLC—QUA9625;(314)578-3406;k.chancello4us.ui.c0m -END OF EVALUATION REPORT- t s l - t f l t { MEMO ETC,LLC Evaluation Repott 518010.48.09-R12 Cetty1cate o/Authorization 1138455 bra EDITION(2017)FBG NON41VHZ EVALUATION FL2589-R14 Soprema Roof Underlayments Revision 12:02/12/2018 Page 8 of 8 s !