Loading...
HomeMy WebLinkAboutProduct Approval- shingles Florida Building Code Online https://www.floridabuilding.org/pr/pi_app_dtl.aspx?param—wGEVX... EL- FLOP=0Q0APWA?0 CIO mG�� - _ -�•, Business & Professional Regulation SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search dbpr product Approval USER:Pubk User Product Approval Menu>Product or Applicatw Search>Apolication List>Application Detail FL# FL10674-R13 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen odf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By 1 of 2 9/4/2018,2:33 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr app_&I.aspx?param=wGEVX... Sections from the Code Product Approval Method Method 1 Option D Date Submitted 113/10/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summa of Products FL# Model,Number or Name Description !0674.1 Owens Coming Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use 1 Installation Instructions Approved for use in HVHZ: No FL10674 R13 II 2017-10—FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.Ddf Impact Resistant: N/A Verified By: Robert 3.M.Nieminen PE- 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to FR, Section 5. Evaluation Reports FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT SHINGLES FL10674-R13.odf Created by Independent Third Party: Yes ® O Contact us;:2601 Bleb stone Road Tallahassee FL 32309 Phone:aso-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mad to this entity.Instead,contact the office by phone or by traditional mal.If you have arty questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address f they have one.The annals provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department wth an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: ® ® ® rL 1- Crpdt* Card Safe Z of 2 9/4/2018.2:33 PM EXTERIOR RESEARCH&DESIGN, LLC. Certificate of Authorization#9503 TRINITY ERD 353 CHRISTIAN OXFORD,,UNIT#13 CT 06478 (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-118 One Owens Corning Parkway FL10674-1113 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404-7829 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: is Robert J.M.Nierninen,P.E. Fs `'' cti A ''.,z ' c The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 ��'��� + Nieminen,P.E.on 10/09/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Prope Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Kntfty Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 DevonshireTM'are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition* Duration, Duration' Premium Cool, TruDefinition Duration' Designer Color Collection, TruDefinition'Oakridge, Oakridge* and WeatherGuardo HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shingles: 4.2.1 Berkshire* Hip & Ridge Shingles, High Ridge, WeatherGuardo HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge—Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certtficate of Authorization#9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 TRINITY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (V.it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip $ ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph (V„it= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 611320-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 611320-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: D Berkshire*shingles require minimum five(5)nails per shingle. D WeatherGuarde HP shingles require minimum six(6)nails per shingle. D Devon T"'shingles require minimum six(6)nails per shingle. D Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlayment Deck Fek underbyment Deck Self-adhered WeatherLock0 Self-adhered underlayment Weathettocke ( .. undedayment Drip - _ - Drip edge edge Dnp edgeDrip Nails located Naas located �� 2'-3from cave 2"-3"from eave Install first Self-sealing adhesive Selfsaafng adhes ve Starter Strip positioned along eave Inst+ first Sv�r$01p potiGorred along eave shingle with \ with 6'mnoved — \ 6"removed Starter Strip shingle overhangs eaves and rakes'h-sh" Starter Strip Plin overhangs eaves and rakes 1/4-3/4" Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate ofAuthorhation#9503 6t"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 TRINITY ERD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Ana pare 7Mnd Mansard or Area para Wind Areas High Wind doavanas y as High Winddesvanas yAna para vientos normaiss Areas vientoa fuertes n Wantos normaias Arses visntos tuerbs �.�r IA) tt,t" �' _' Is 2' • �� IAl � �' �' 2' IBIS,,£?' �'1 U,Exposure 5 SW Exposure Exposici6n Exposici6n 6.2.7 Minimum Nailing—Berkshire®: Sealant strip Sealant strip La!ira A sellador La Iva de seRador 001 �4--P s —► a �-- a r—�• • • • • • • i"— a v e 9 vt' 9 vt' a ve j ,811' 8'n" 8 ly. 8+n" 1 V, r r r Standard Fastening Pattern 6-Nail Fastening Pattern SealarM stria La lira de%flador ef—�•r—i• • ---------- 8 12' ---s812' R'if t7= 1 ♦*�� L" Asphak rwhngoentertt Cemento do facho de Waho Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118 Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 TRINITY ERS 6.2.8 Minimum Nailing—Devon[[EeTNt I1 1 1- 7 8" g" 1 8. I • Ns w Gaya Alms 5-5/8"exposure Sealant location ' Exposition de 5.518 pulg Ubicacion del sellador Ten 1"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration", TruDefinition" Duration, Duration® Premium Cool & TruDefinition* Duration Designer Color Collection: 4-Nall Fastening Pattern 6-Nall Fastening Pattern Etna s ft&W na area detlr lrasNaae feshm"ana wah r rfaa Typvi (({� N,a.t,p—, 1" 12- 1r 1^ 1^ tr F] ..:mac-�w.....>c • e,7j,>.,:.^.,.�,..o eo.>.,c .arW..>. e 9.11a"a-ds" 6-1n" barb' Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Grater Than 21:12 auna.W baba"—dem lana.rip" 1" it it ..ia•sera^ 00 Four V ipob of Asptmh RooA"C.r.M Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate ofAuthorization X9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page S of 8 TRINITY ERD - 6.2.1 Minimum Nailing—TruDefinition Oakridge®,Oakridge®: 4 Nail Patten 6 Nail Pattarn Esquema con 4 ciavos Esquema con 6 clavos 1" 1" 1" 1" It-- rr —►I It— n 6618"ExposureNails5 5/8"Exposure Nails Exposiddn dr 66/B pufg. clams Expos1d6n de 66/8 pu(g. 5 518"Exposure clavas 5 5/8"Exposule Exposiddn de 6 5/8 pulp. Exposidbn de 6 6/0pdS Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 WIbikq hp•ning ens MIEN N.M.lyPkW 1" 12' ta' 411 s so Four 1"Spots of AspW Roo"C�t Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard®HP: I single a"view I•— r t �i a�..w bib ti f�dira Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 61H EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 TRINITY ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, WeatherGuarda HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRE6L.T-Hip OF dj�gleElhall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 4 Fig.2 r.. PleaaligYNn/ [71raAlsn A Top"M %demes Naas�_� A Nsla NNo 4 I I r r T"Lanalal Y A 1 I 1' Plp A I I 9 1 1 A I I 1 I I P l I 1 1 1 I 1 ros r l EXoawas 1 1 1 1Y PI 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A ?e Pr= Topvbw Wmt—dbn A A Naas I 1 A i 1 Nails a" Sr. A I 1 i s' 'I Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate ofAuthori:ation#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 TRINITY ERD 6.3.S Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard —11"— Wind 1"Wind DirectionFastening Sealant Strip Pattern .—` 6'Exposure r N �I•I I� r ,2' 1 1 Seelstn ''h Fasten Tyr' 7 8"Exposure Cover Exposod Fasteners with Roof Cement 6.3.6 Minimum Nailing—DuraR15BTmHip DaE6b sEia&C] Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Pro"An`Wind Direction Top vies Direction dormmnte dr vent Vue"PL_ Dir•cdandol•iontopredornimnto I- Y.styerlor I•I t cis. Naik0.3 40" • OCatLq 50~ • cr..e C Clatoi� j j 1 IJ J I�•_— I I 12- 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (631)546-2458; Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate ofAuthorization#'9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:1010912017 Page 8 of 8