Loading...
HomeMy WebLinkAboutRevision OFFICE USE ONLY: c� DATE FILED: d�-n�i� ' PERMIT# 1806-0028 REVISION FEE: (9 RECEIPT# PLANNING &DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772)462.1553 APPLICATION FOR BUILDING PERMI I PROJECT INFORMATION O� N LOCATION/SITE ADDRESS: 6804 Santa Clara Blvd,Fort Pierce FL DETAILED DESCRIPTION OF PROJECT REVISIONS: Change Product Approval From Shingles to Metal CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CCC1327208 ST. LUCIE CO CERT. #: BUSINESS NAME: Sunrise City CHDO Inc. QUALIFIERS NAME: Roderick Waller ADDRESS: 3550 Okeechobee Rd CITY: Fort Pierce STATE: FL ZIP: 34947 PHONE(DAYTIME): 772-201-2850FAX: 772-907-0420 OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE(DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: SLCCC: 9/23/09 Revised 06/30/17 :Rc Ek' AUG 2 4 2018 Permitting Department �^l 9t^e 4ifwY/BPS.:' 4` TTt� BCIS Home Log In User Registration Hot Topics Submit Surcharge I Stats&Facts Publications j FBC Staff BCIS Site Map Links Search j a r 4 s Product Approval {.L: USER:Public User d1b ^ �t�.vn:t `� Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL20484-R1 Application Type Revision Code Version 2017 Application Status Approved Comments Archived C:; Product Manufacturer UNION CORRUGATING COMPANY Address/Phone/Email 701 S. KING ST. FAYETTEVILLE,NC 28301 (910)483-0479 Ext 256 jstieby@unioncorrugating.com Authorized Signature John Stieby jstieby@unioncorrugating.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer CEvaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Bala Sockalingam the Evaluation Report Florida License PE-62240 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 09/07/2027 Validated By Yoosef Lavi,P.E. (d: Validation Checklist-Hardcopy Received Certificate of Independence FL20484 R1 COI CertificateIndeoendence.pdf Referenced Standard and Year(of Standard) Standard Year FM 4470 2012 TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/23/2017 Date Validated 08/28/2017 Date Pending FBC Approval 09/01/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 20484.1 5V Min 26 ga.,24"wide through fastened panel over 15/32"thick plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL20484 R1 II EvaluationReDOrtC2175 1.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam,P.E.62240 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-169 Evaluation Reports Other:Uplift load of 71.0 psf @ fastener spacing of 24"o.c.& FL20484 R1 AE EvaluationReDOrtC2175 S.odf 169.0 psf @ fastener spacing of 6"o.c. Created by Independent Third Party:Yes 20484.2 Advantage-Lok II Min 26 ga., 16"wide concealed fastened panel over 7/16"thick OSB&15/32"&thick plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL20484 R1 II EvaluationReoortC2175 2.Ddf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam P.E.62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-116 Evaluation Reports Other:Maximum uplift load of 116.0 psf @ seam fastener FL20484 R1 AE Eva IuationReDortC2175 2.1)df spacing of 4-5/8"o.c.along seam into min. 15/32"thick APA Created by Independent Third Party:Yes rated plywood with retainer strap. 20484.3 Aluminum Advantage-Lok II Max 16.375"wide, nom 0.032"thick(min.)aluminum concealed fastener roof panel over min 15/32"thick plywood deck or 7/16"thick OSB. Limits of Use Installation Instructions Approved for use in HVHZ:No FL20484 R1 II EvaluationReDOrtC2175 3.Ddf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam P.E.62240 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-93.5 Evaluation Reports Other: Uplift load of 22.5 psf at fastener spacing of 18.5"o.c. FL20484 R1 AE EvaluationReoortC2175 3.Ddf and 86.0 psf at fastener spacing of 4.63"o.c. in 15/32" Created by Independent Third Party:Yes plywood or 7/16"OSB.Uplift load of 93.5 psf at fastener spacing of 4.63"o.c.with structural sealant in 15/32"plywood. 20484.4 Aluminum SL150 Max 16"wide,nom 0.032"thick(min.)aluminum snap-lock standing seam metal panel over min 15/32"thick plywood deck or 7/16"thick OSB Limits of Use Installation Instructions Approved for use in HVHZ:No FL20484 R1 II EvaluationReoortC2175 4.Ddf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam P.E.62240 Impact Resistant:N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-86 Evaluation Reports Other:Uplift load of 45.0 psf at clip spacing of 24"o.c.and FL20484 R1 AE Eva IuationReoortC2175 4.pdf 78.5 psf at clip spacing of 6"o.c.in 15/32"plywood or 7/16" Created by Independent Third Party: Yes OSB.Uplift load of 86.0 psf at clip spacing of 6"o.c.with structural sealant in 15/32"plywood. 20484.5 MasterRib Min 29 ga., 36"wide through fastened panel over 15/32"thick plywood or 7/16"thick OSB Limits of Use Installation Instructions Approved for use in HVHZ: No FL20464 R1 II EvaluationReoortC2175 5.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam,P.E. 62240 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-124 Evaluation Reports Other: Uplift load of 56.0 psf @ fastener spacing of 24"o.c.& FL20484 R1 AE Eva luationReoortC2175 S.Ddf 124.0 psf @ fastener spacing of 6"o.c. Created by Independent Third Party: Yes 20484.6 MasterRib Min 29 ga., 36"wide through fastened panel over 15/32"thick plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL20484 R1 II EvaluationReDortC2175 6.Ddf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam,P.E.62240 Impact Resistant:N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-88.5Evaluation Reports Other: Uplift load of 56 psf for Fastening System 1. Uplift load FL20484 R1 AE EvaluationReoortC2175 6.Ddf of 88.5 psf for Fastening System 2. Created by Independent Third Party:Yes 20484.7 ML150 Max 16.5"wide, min 24 ga.steel standing seam panel over 15/32"thick plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL20484 RI II EvaluationReoortC2175 7.odf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam, P.E. 62240 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-124 Evaluation Reports Other:Maximum uplift load of 124 psf @ clip spacing of 6" FL20484 R1 AE Eva IuationReoortC2175 7.Ddf o.c.with 180 seam,self-adhering membrane and fixed clip. Created by Independent Third Party:Yes 20484.8 PBR or R Panel Min 26 ga.,36"wide through fastened panel over 15/32"thick plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL20484 R1 II EvaluationReDOrtC2175 8.Ddf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam P.E.62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-161.5 Evaluation Reports Other:Uplift load of 30.0 psf at fastener spacing of 48"o.c. FL20484 R1 AE EvaluationReDOrtC2175 8.Ddf and 161.5 psf at fastener spacing of 6"o.c. Created by Independent Third Party: Yes 20484.9 SL175 Max 18"wide,min 24 ga.,snap-lock standing seam metal panel over 15/32"thick plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL20484 RI II EvaluationReoortC2175 9.Ddf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam,P.E.62240 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-93.5 Evaluation Reports Other: Uplift load of 39.8 psf @ clip spacing of 36"o.c.and FL20484 R1 AE EvaluationReDortC2175 9.Ddf 78.6 psf @ clip spacing of 8"o.c with felt.Uplift load of 93.5 Created by Independent Third Party: Yes psf @ clip spacing of 12"o.c.with self-adhering membrane. Back tvext Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: 0 WN eCQ.M Credit Card Safe .3 r� .i EVALUATION REPORT OF UNION CORRUGATING COMPANY j '26 GA.5V PANEL' i FLORIDA BUILDING CODE 6TH EDITION(2017) FLORIDA PRODUCT APPROVAL FL 20484.1-R1 ROOFING METAL ROOFING i Prepared For: Union Corrugating Company 701 S.King St. Fayetteville,NC 28301 Telephone: (910)483-0479 Fax: (910)483-1091 z Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer#62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918)492-5992 FAX: (866)366-1543 This report consists of Evaluation Report(3 Pages including cover) Installation Details (1 Page) ` Load Span Table (1 Page) �e� G� . qM fsB m v;v 62`L : tL� -, m. F ;zz Report No. C2175-1 Date: 8.23.2017 5 f r'p"TO,•• L . . ��Qyt;O • 0 �. :859a 0�° i FL 20484.1-R1 C2175-1 8.23.2017 Page 2 of 3 Manufacturer: Union Corrugating Company Product Name: 5V Panel Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 15/32" thick APA rated plywood or min. 3/a" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction. Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2 Design Uplift Pressure: 71.0 psf @ fastener spacing of 24" o.c. (Factor of Safety=2) 169.0 psf @ fastener spacing of 6" o.c. Panel Attachment: #10-15 x 2" long wood screw with washer At interior @ max 12" o.c. across panel width through panel rib At panel ends @ max 6" o.c. across panel width through panel flat and rib Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering Systems'. Test Equivalency: The test procedures in UL 1897-04 comply with test procedures prescribed in UL 1897-12. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Union load span table. This evaluation report is FL 20484.1-R 1 C2175-1 8.23.2017 Page 3 of 3 not applicable in High Velocity Hurricane Zone. Refer to current NOA for use of this product in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580 &UL1897 Test Reports Farabaugh Engineering and Testing Inc. Project No. T197-16, Reporting Date 5/12/16 I� PANEL OVERLAP cno vans NEW UNDERLAYMENT PANEL FASTENER ROOF PANEL SEE DETAIL 2 SEE DETAIL 1 SPACING PER ALLOWABLE 3 r�- r UPLIFT LOAD TABLE S J J EXISTING UNDERLAYMENT EXISTING SHINGLES DECK ATTACHMENT AND PLYWOOD (OPTIONAL) (OPTIONAL) SUPPORTS MUST BE 15/32"THICK(MIN.) DESIGNED AND INSTALLED BY OTHERS g MIN. 2X_WOOD RAFTER.JOIST/ TRUSS AT MAX. 24"O.C. TYPICAL PANEL INSTALLATION X-SECTION V � n (7 Warn #10-15 X 2"LONG WOOD zQ C'- SCREW WITH WASHER z n 0 x'ja NEW UNDERLAYMENT MIN 26 GA, PANEL V viE z K� 0 oY O1 z LL 5� EXISTING SHINGLES 51 (OPTIONAL) W � 0 EXISTING UNDERLAYMENT PLYWOOD d 8 (OPTIONAL) 15/32 THICK(MIN.) a DETAIL 1 ' GENERAL NOTES: z Oggg 1.ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE 3�Y #10-15 X 2"LONG WOOD FLORIDA BUILDING CODE (FBC). SCREW WITH WASHER 2. ROOF PANELS SHALL BE MINIMUM 26 GA. EFFECTIVE COVERING WIDTH OFuoqi PANEL 24. _ �m ( 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING& STRUCTURE AS NEW UNDERLAYMENT MIN 26 GA. PANEL SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE. 5.ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING &THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM EXISTING SHINGLES REQUIREMENTS OF THIS DRAWING &THE CODE, THE CODE SHALL CONTROL. (OPTIONAL) 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. EXISTING UNDERLAYMENT PLYWOOD (OPTIONAL) DETAIL 2 15/32"THICK(MIN.) 02175-1 SHEEP NO. 1 a 1 it t UNION CORRUGATING COMPANY k 5V Panel Uplift Loads s (Min 26 ga.) Description Fastener Spacing Allowable Uplift along Panel Length Load E (in) (psf) Coverage width: 24" 6 169.0 8158.1 _._........ -- ___. Panel Fasteners 10 . .....................__ -- #10-15 hex head screws with 12136.3 ........_....... _. _ ---- sealed washer 14121.7 16106.5 .................__._. Panel fasteners spaced at 12" 18 94.7 o.c. across panel width 20 85.2 through ribs. — - 22 77.5 24 71.0 Notes: 1. The bold numbers indicate design loads calculated from test data with safety factor of 2. 2. Panels must be installed as per Evaluation Report FL 20484.1 and Union current installation procedure. ge�eeeee®oar vo deeG�xL I N Gqrr®s o vo` 5�••�t4 S E•.,M Dope ev•vG 2�0 •� a m. N° ;We 9F ;W ooa O,� L 0 1216 N Lansing Ave.,Suite C a r S I O` ° Bala Sockalingam,Ph.D.,P.E. Tulsa,Ok 74106FL 62240 918 492 5992 3 a t I