Loading...
HomeMy WebLinkAboutdrawing- pressure info Opening I Size (W x H) 1. 18-0122.11 35 x37 (DOUBLE HUNG) 2. 18-0122.11 25 x37 (DOUBLE HUNG) 3. 18-0122.11 25 x 61 O (DOUBLE HUNG) 4. 18-0122.11 25 x 61 Q (DOUBLE HUNG) 5. 18-0122.11 35 x 36 Z (DOUBLE HUNG) _ 6. 18-0122.11 35 x 61 ELL 4 (DOUBLE HUNG) 7. 18-0122.14 36 x61 4 (CASEMENT)8. 18-0122.14 35 x61 31 (CASEMENT) 9. 18-0122.11 25 x61 (DOUBLE HUNG) v 10. 18-0122.11 25 x61 (DOUBLE HUNG) 211. 18-0122.11 36 x61 (DOUBLE HUNG) 5 6 4„ E ^ N 12. 18-0122.11 36 x 61 (DOUBLE HUNG) EGRESS82„ N v N N m � m m KITCHEN BED 2 w 7 o G) n a LL W 27' U-)W 2 M Q O � ofw 8 _j - W Q co W GARAGE LIVING BED 3 w Z o a "t FD 0 EGRESS EGRESS 94�� O u- 12 11 10 9 24" 1 OPYRR:IIT ErENPEsr.<aI SCALE: 82' NOT TO SCALE DATE: Sep 19,2018 FADE DESCRIPTION: Site Plan PAGE: Of 1 MRH = 12' OTM I G HT 500 SW 12th Ave Deerfield Beach,FL 33442 WIND 0 W S Ph.561-922-6747 Fax.561-292-3562 Property Information Building Information Owner: ANGEL DANIEL Wind Zone: 170 MPH. Address: 7407 SALERNO RD. Exposure Category: C FORT PIERCE,FL 34951 Minimum Building Dimension: 27 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) FElevation(ft) Pressure(p-.;f) Pressure(psf) 1 Int 35 37 7 37.8 -41.0 2 Int 25 37 7 37.8 -41.0 3 End 25 61 7 37.7 -50.3 4 End 25 61 7 37.7 -50.3 5 Int 35 36 7 37.8 41.0 6 Int 35 61 7 36.8 40.0 7 Int 36111 61 7 36.8 -40.0 8 Int 35 61 7 36.8 -40.0 ............................ 9 End 25 61 7 37.7 -50.3 10 Int 25 61 7 37.7 -40.9 11 Int 36 61 7 36.8 -40.0 12 Int 36 61 7 36.8 -40.0 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of I WINDOW & DOOR • ' • ' • 7407 SALERNO RD. ANGELA DANIEL & DEBORAH ADKINS - 8202 A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone -100/6 of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING MULLION SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF SIZE(+)PSF (-)PSF DIMENSIONS REQ Y/N REQ Y/N/NA I Int Window 7""'""'"`' 18-012211 55 55 37.8 -41.0 53x77 3507 No No 2 Int Windoxt "'" 18-0122.11 55 55 37.8 1 -41 .0 53x77 2507 No No 3 End Window "8 "' 18-0122.11 55 55 37.8 -50.6 5307 25x61 No No 4 End Window " 1 mnIG 18-0122.11 55 55 37.8 -50.6 5307 25x61 No No 5 Int `°'indoA I S"La"'"" 1 18-0122.11 55 55 37.8 -41.0 5307 3506 No No 6 Int "i°' "`" 18-0122.11 55 55 37.8 -41 .0 53x77 35x61 No No 7 lilt Window ""' "''"' 18-0122.14 55 55 37.8 -41.0 3608 36x61 No No 8 Int `t'ind' "'„ 1618-0122.14 55 55 37.8 -41 .0 36x68 35x61 No No 9 End Window °""`, 18-0122.11 55 55 37.8 -50.6 5307 25x61 No No 10 Int Windov� °" 18-0122.11 55 55 37.8 -41 .0 5307 25x61 No No 11 lilt Window ""' 18-0122.11 55 55 37.8 -41.0 53x77 36x61 Yes No 12 Int %Vindow N i °'"' 18-0122.11 55 55 37.8 -41 .0 53x77 36x61 Yes No