HomeMy WebLinkAboutdrawing- pressure info Opening I Size
(W x H)
1. 18-0122.11 35 x37
(DOUBLE HUNG)
2. 18-0122.11 25 x37
(DOUBLE HUNG)
3. 18-0122.11 25 x 61 O
(DOUBLE HUNG)
4. 18-0122.11 25 x 61 Q
(DOUBLE HUNG)
5. 18-0122.11 35 x 36 Z
(DOUBLE HUNG) _
6. 18-0122.11 35 x 61 ELL 4
(DOUBLE HUNG)
7. 18-0122.14 36 x61 4
(CASEMENT)8. 18-0122.14 35 x61 31
(CASEMENT)
9. 18-0122.11 25 x61
(DOUBLE HUNG) v
10. 18-0122.11 25 x61
(DOUBLE HUNG) 211. 18-0122.11 36 x61
(DOUBLE HUNG) 5 6 4„ E ^ N
12. 18-0122.11 36 x 61
(DOUBLE HUNG) EGRESS82„ N v N N
m
� m m
KITCHEN BED 2 w 7 o G)
n a LL
W
27' U-)W 2 M
Q O �
ofw
8 _j -
W Q co W
GARAGE LIVING BED 3 w Z o
a "t
FD 0
EGRESS EGRESS 94�� O
u-
12 11 10 9 24"
1
OPYRR:IIT ErENPEsr.<aI
SCALE:
82' NOT TO SCALE
DATE:
Sep 19,2018
FADE DESCRIPTION:
Site Plan
PAGE: Of
1
MRH = 12'
OTM
I G HT
500 SW 12th Ave
Deerfield Beach,FL 33442
WIND 0 W S Ph.561-922-6747
Fax.561-292-3562
Property Information Building Information
Owner: ANGEL DANIEL Wind Zone: 170 MPH.
Address: 7407 SALERNO RD. Exposure Category: C
FORT PIERCE,FL 34951 Minimum Building Dimension: 27 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) FElevation(ft) Pressure(p-.;f) Pressure(psf)
1 Int 35 37 7 37.8 -41.0
2 Int 25 37 7 37.8 -41.0
3 End 25 61 7 37.7 -50.3
4 End 25 61 7 37.7 -50.3
5 Int 35 36 7 37.8 41.0
6 Int 35 61 7 36.8 40.0
7 Int 36111 61 7 36.8 -40.0
8 Int 35 61 7 36.8 -40.0
............................
9 End 25 61 7 37.7 -50.3
10 Int 25 61 7 37.7 -40.9
11 Int 36 61 7 36.8 -40.0
12 Int 36 61 7 36.8 -40.0
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of I
WINDOW & DOOR • ' • ' •
7407 SALERNO RD. ANGELA DANIEL & DEBORAH ADKINS - 8202
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone -100/6 of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING MULLION SHUTTERS
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF SIZE(+)PSF (-)PSF DIMENSIONS REQ Y/N
REQ Y/N/NA
I Int Window 7""'""'"`' 18-012211 55 55 37.8 -41.0 53x77 3507 No No
2 Int Windoxt "'" 18-0122.11 55 55 37.8 1 -41 .0 53x77 2507 No No
3 End Window "8 "' 18-0122.11 55 55 37.8 -50.6 5307 25x61 No No
4 End Window " 1 mnIG 18-0122.11 55 55 37.8 -50.6 5307 25x61 No No
5 Int `°'indoA I S"La"'"" 1 18-0122.11 55 55 37.8 -41.0 5307 3506 No No
6 Int "i°' "`" 18-0122.11 55 55 37.8 -41 .0 53x77 35x61 No No
7 lilt Window ""' "''"' 18-0122.14 55 55 37.8 -41.0 3608 36x61 No No
8 Int `t'ind' "'„ 1618-0122.14 55 55 37.8 -41 .0 36x68 35x61 No No
9 End Window °""`, 18-0122.11 55 55 37.8 -50.6 5307 25x61 No No
10 Int Windov� °" 18-0122.11 55 55 37.8 -41 .0 5307 25x61 No No
11 lilt Window ""' 18-0122.11 55 55 37.8 -41.0 53x77 36x61 Yes No
12 Int %Vindow N i °'"' 18-0122.11 55 55 37.8 -41 .0 53x77 36x61 Yes No