HomeMy WebLinkAboutWINDOW/DOOR INSTALLATION RESIDENTIAL (6) 6/4/2018 Florida Building Code Online
If
j rte- ° 1pn-
1
�
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats 9 Facts Publications FSC Staff SCIS Site Map Unks Search
bProduct
di kI ra Approval
00 USER:Public User
i„9&111 -aorgvat Menv>MOR or Aoolieation Search>&Iiicatian f 1st>Application Deft"
FL# FL16842A114
_ Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer NewSouth Window Solutions
Address/Phone/Email 4901 oak fair blvd
tampa,FL 33610
(513)284-0129
danochsteln@newsouthwindow.com
Authorized Signature Vivian Wright
rickw@rwbldgconsuftants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Horizontal Slider
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Ryan J.King,P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence X842 R4 COI (c)Certificate of 1_ ndepgndence.pdf
Referenced Standard and Year(of Standard) Standard xis
AAMA/WDMA/CSA101/1.S.2/A440 2008
AAMA/WDMA/CSA101/I.S.2/A440 2005
AAMA/WDMA/CSAI01/I.S,2/A440 2011
ASTM E1886 2005
ASTM E1996 2Q06
ASTM E1996 2005
ASTM E1996 2009
TAS 201,202,203 1994
Equivalence of Product Standards
Certified By
https://www.floridabuilding.org/pr/pr app_d#.aspx?param=wGEVXQvdDgtmmTSTNdVPsf%2(LKgxApZZQumXyGur83s42hZkY3sC4ZA%3d°/a3d
6/4/2018 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/11/2017
Date Validated 10/20/2017
Date Pending FBC Approval 10/23/2017
Date Approved 12/12/2017
Summary of Products
Go to Page Page 1/2(�
FL i! Model,Number or Name Description
16842.1 a.Series 9000 Model 9500 Slider XO Extruded Vinyl"Non-Impact"Horizontal Sliding Window
utilizing a Nall Fin Installation(XO or OX configurations)
Limits of Use Installation Instructions `--- ---
Approved for use in HVHZ:No FL1684?_ R4 Ii (h)Inst 16842.1.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.1 for Design Pressure Ratings,any FL16$42 R4 AE (b) Eval 16842,1.pdf
additional use limitations, installation Instructions and product Created by Independent Third Party:Yes
particulars.
16842.2 _ b.Series 9000 Model 9500 Slider XO Extruded Vinyl"Non-Impact"Horizontal Sliding Window with
Flange Installation(XO or OX configurations)
Limits of UseInstallation Instructions
Approved for use In HVHZ:No FL16842 R4 11 (k)Inst 16842.2.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant., No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.2 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval66842.2,pdf
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
16842.3 c.Series 9000 Model 9550 Slider XO- Extruded Vinyl"Impact"Horizontal Sliding Window utilizing a
Impact Rated Nail Fin Installatlon(XO or OX configurations)
Limits of Use — -- Installation Instructions -
Approved for use in HVHZ:No F06842 R4 II (0)Inst 16842.3.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.3 for Design Pressure Ratings,any FL16$42 R4 AE (h)Eval 16842,3.pdf
additional use limitations, Installation Instructions and product Created by Independent Third Party:Yes
particulars.
16842.4 I d.Series 9000 Model 9550 Slider XO Extruded Vinyl"Impact"Horizontal Sliding Window with Flange
-Impact Rated Installation(XO or OX configurations)
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL16842 R4.I1 (t)Inst 16842.4.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.4 for Design Pressure Ratings,any FL16842 R4 AE (¢)Eval 16842,4.pdf
additional use limitations, Installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.5 e.Series 9000 Model 9550 Slider XO Extruded Vinyl"Impact"Horizontal Sliding Window utilizing a
-Impact Rated- HVHZ Nail Fin Installation(XO or OX configurations)
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL16842 R4 11 (P)lust 16842.5_pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes j
Design Pressure:N/A Evaluation Reports i
Other:See INST 16842.5 for Design Pressure Ratings,any FL16042 R4 AE (t)Eval 16842,5.pdf
I additional use limitations, Installation Instructions and product Created by Independent Third Party:Yes
particulars.
i 16842.6 i f.Series 9000 Model 9550 Slider XO ,Extruded Vinyl"Impact"Horizontal Sliding Window with Flange
hnps://www.floridabuilding.org/prlpr_app_dil.aspx?param=wGEVXQvADgtmmTSTNdVPsf%2fLKgxApZZOu mXyG ur83s42hZkY3sC4ZA%a3d%3d
6/4/2018 Florida Building Code Online
-Impact Rated-HVHZ Installation(XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes. FL168V R4 11 (b) st 684 6 df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.6 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval66842.6.pdf
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
16842.7 g.Series 9000 Model 9500-3 Slider Extruded Vinyl"Non-Impact"Horizontal Sliding Window
XOX utilizing a Nail Fin Installation(XOX,configuration)
•Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16842 R4 II (b)Inst 16842.7.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.7 for Design Pressure Ratings,any 1`1_36842 R4 AE (b)Fval168423& f
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
16842.8 - h.Series 9000 Model 9500-3 Slider Extruded Vinyl"Non-Impact"Horizontal Sliding Window with
XOX Flange Installation(XOX,configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL16842 R4 11 (b)Inst 16842.8.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.8 for Design Pressure Ratings,any &&15842 R4 AE (b)Eval 16842,8,pdf
additional use limitations,Installation instructlons and product Created by Independent Third Party:Yes
particulars.
16842.9 -- I.Series 9000 Model 9550-3 Slider Extruded Vinyl"impact"Horizontal Sliding Window utilizing a
------- -- — —
XOX-Impact Rated Nail Fin Installation(XOX,configuration)
Limits of Use --^-- - Installation Instructions —�— -
Approved for use in HVHZ:No FLifi_042R4 II (b) Inst 16842.9.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.9 for Design Pressure Ratings,any F1.16842 R4 AE (b)Eval 16842.9.pAf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.10 _ ).Series 9000 Model 9550-3 Slider Extruded Vinyl"Impact"Horizontal Sliding Window with Flange
fi XOX-Impact Rated Installation(XOX,configuration)
Limits of Use Installation Instructis
Approved for use In HVHZ:No FL16842 R4 11 (b)Jnon16842,)O,pdf
Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.10 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.10.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
--.- -• -- __ _ _ _-__-- _.___._. __._._ -----------_._
16842.11 k.Series 9000 Model 9550-3 Slider Extruded Vinyl"Impact"Horizontal Sliding Window utilizing a
XOX_Impact Rated-HVHZ Nall Fin Installation(XOX,configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL16842 R4 II (b)Inst 16842.11.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F,Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.11 for Design Pressure Ratings,any FL16842 R4 AE (b)Evai 16f342.II.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars. `
16842.12 11,Series 9000 Model 9500-3 Slider Extruded Vinyl"Impact"Horizontal Sliding Window with Flange
XOX-Impact Rated-HVHZ Installation(XOX,configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16842 R4 11 (b)Inst 16842,12.pdf
i Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.12 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval)6842.12,�df
additional use limitations,Installation instructions and product Created by Independent Third Party:Yes
particulars.
j � I '•
https://www.floridebuilding.org/pr/pr_apP dtl.aspx?parem=wGEVXQwIDgtmmTSTNdVPsf%2fLKgxApZZOumXyGur83s42hZkY3sC4ZA%3d%3d
6/4/2018 Florida Building Code Online
16842.13 I m.DuraGard Slider XX Extruded VinylNon-Impact"Horizontal Sliding Window
utilizing a Nall Fin Installation(XX,configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16842 R4 11 (b),Inst 16842.13.Rd_f
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.13 for Design Pressure Ratings,any FL16842 R4 AE (b) Eval 16842.13,pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.14 I n. DuraGard Slider XX Extruded Vinyl"Non-Impact"Horizontal Sliding Window(XX,
1 configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No )_L16842 R4 lI (b)Inst 16842,14.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.14 for Design Pressure Ratings,any FL16842 R4 AE (p)Eval 16B42.14,Pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.15 o.DuraGard-3 Slider XOX Extruded Vinyl"Non-Impact"Horizontal Sliding Window
utilizing a Nail Fin Installation(XOX,configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FLI6842 R4 II (b) Inst 16842,i5.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.15 for Design Pressure Ratings,any Fi_16642 R4 AE (b) Eva] 1684 .15.Ddf
additional use limitations,Installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.16 _ p.DuraGard-3 Slider XOX Extruded Vinyl"Non-Impact"Horizontal Sliding Window with
Flange Installation(XOX,configuration)
Limits of Use Installation Instructions -
Approved for use in HVHZ:No FL16a42 R4 ll (b) In 16842.16.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.16 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.16.adf
additional use limitations,Installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.17 Y q.Sashlite Slider XX Extruded Vinyl"Non-Impact"Horizontal Sliding Window- 1
_ — — utilizing a Nail Fin Installation(XX,configuration) 11
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL16842 R4 11 (h Inst 16842.17.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.17 for Design Pressure Ratings,any FL16842 R4 AE (12) Eval 16842.17.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.18 r,Sashllte Slider XX Extruded Vinyl"Non-Impact"Horizontal Sliding Window(XX,
configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL16842. R4 11 (b)Zn5t 16842.18.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.18 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.18.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.19 l s.Sashlite-3 Slider XOX Extruded Vinyl"Non-Impact"Horizontal Sliding Window
utilizing a Nail Fin Installation(XOX,configuration) I
Limits of Use Installation Instructions +�
Approved for use in HVHZ: No FL16842 R4 11 (b)Inst 16842.19.pdf
i Approved for use outside HVHZ:Yes Verified By: Lyndon E Schmidt, P.E.43409 j
Impact Resistant: No Created by Independent Third Party:Yes I
Design Pressure:N/A Evaluation Reports j
Other:See INST 16842.19 for Design Pressure Ratings,any FL16842 R4 AE (b) Eval 16842,19.pdf
additional use limitations,Installation instructions and product 1 Created by Independent Third Party:Yes
particulars_ II i
https://wwvv.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtmmTSTr dVPsf%2fLKgxApZZOumXyGur83s42hZkY3sC4ZA%3d%3d
6/4/2098 Florida Building Code Online
16842.20 I t.Sashlite-3 Slider XOX Extruded Vinyl"Non-Impact"Horizontal Sliding Window(XOX,
11 configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL16842 R4 11 (b)last 16842.2p.p ff
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 16842.20 for Design Pressure Ratings,any FL16842 R4 AE (D).Eval 16842.20.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
Go to Page Page 1/2
0 0
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850.467-1624
The State of Florida Is an WEED employer.0i ydght 2007-2013 State of Florida.::PrWacv Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 650.467.1395.-Pursuant to section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have
one.The emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the.public.To determine If you are a licensee under Chapter 455,F.S.,
please dick LUL.
Product Approval Accepts:
eCt�e:
c 1 -�6 errs 1-..
Credit Card
Safe
haps://www.floridabuilding.org/pr/pr app_dtl.aspx7param=wrGEVXQwtDgtmmTSTNdVPsfa/o2fLKgxApZZQumXyGur83s42hZkY3sC4ZAa/o3da/o3d
0MMO
. ..........
'..'Newhusthe : dR •i 'z��
i i
fflWINDOWSOLUTIONS
4901 Oak Fair 81Vd.,Tampa,FL 33610 75'MAX.OVEM RANGE WIDTH
74"MAX.OVERALL FRAME WIDTH u
Series .9000 Model 9550 � � \ �a Ed:
SLIDER X® Ta
IMPACT MATED a HVHZwl Flange
o�
Q GENERAL NOTES c z
1. This product has been evaluated end B In eompkme w/Ah the 6th Edition(20171 flarida r�xbb Z
Building Code(FBCI structural requIrements Including the'High Velocity Htmleane Zone' "' O 13
Kwn-
8 2 Product anchors shoo be as rated and spaced as shown on detalh.Anchor embedment to
base material shag be beyond wol dresdrig or stucco. O I a
3. When used in the 1WHZ'th1s product compSesvAth Section 1626 of the Florida BuUng Code 5
and does not requIre an knpoct reshfant covering.
4. When used In areas outside of the°HVHr mqufring vMd tame debris protection ft product
compft with PBC Seettons 1609.12&R3a1.212 mrd does not require an Impact resMant n 3 R
covering.lids product meets mbft levet V and includes Wind Zone 4 as defined In ASTM
E1996 and FBC Secfbm 1609.122 8 R3012.12.L [u B
CA
V _
5. Forst stud fronting coruhuctfat anchoring of these units shill be the same as that sho"for m m
2+c buck masonry construction. ppy I
6. Site condBons that de*to from the detab of RrB drawing requte further engineering cmNsls
by a Lensed eroneer or registered amhfted. z
z ^
7. This product meets waterinfithatlanrequkements for`HVHr. Nm m z
N N^N Q r
TABLE OF CONTENTS
MAIL OVERALL MAX OYBALL MAX MAX DESIGN►12ES M
_
g SHEETP DESCl1fr7TON FLANGE :FRARSE DAXIDE, t>IIYIl1E GLASS e n a^ 9
1 TypIcal ekvvOtiOtK dWM p omm 6 gel eSCIMENSIDN'. DIMPLUDN IMM CAM 2119114 i
2 Vertical&horkontalcrosssections DIMAVSlOAC D1MF1Q10>P (OtlEltAtltq,, PYO. 1VEG. sw,.. N.T.S. °
3 Vertical 3.hofinDntal crass sections Mr X 64.6' 74.9'X 61.8' 333'X 57.31' 3&W X 65.56' 01.02 ¢5&0 1 .60.0 DM.W. JK
4 Buck b me oac M. LFS 3
ae�wM=A a
S Components Note:fig product•when used wlthh Gl glaft,Is rat approved for use above 30 feet in the INN. FL-16842.6
6 of matertak amng details
0
c sx¢er 1 cw 6 g
0
'a
-FA-'me
° 9'Zi89[-7i
a amew.� u0 nMwcONtwioW; JwmW*,oYXl wypWawDwa[WVXoYI[d/ 6 +
Sd[ w ra �71� 3!lSOL77y1N L N3 'J71►Jf10tliON`LJ !
gg Nr +a ma fdAil ive
'Sl'M vx� +_� NMY.t/l-i 801791X� L l Q
*L16913 arra A . ► Q
"v V ■ Q • r
93WN3s It zl
• LL la[a[aas
OL S1 L!� L9 OL a P
w .� fL L Y
£ l9 L9 •� L
"� ► taut•wa
WON 7ilYilhl
I Holum
f i �rseaa.ZJl Y9t f91
�al� o91N9s1
4
W t �uwaoouaaanuawrw c
LJ lwUq wlAvwwos
w �+
K L -"Pao-q4*aNpwtP-
calowaas
� L -
$ L9 tit �
V Xrap
JAMW
O
* l��faZi�lla4��11>i�Y41o'4W �/ 7/
i i ��[a4w[�d WW�bSIWoW[�B aION
is.oil
Ndi@Shea�MelalSaewtmadpenepalea
x mhed 2headslMaghatkM2dmbof
meld Gnoinial,a mh 81s'e40e dh
=g
w
AS
X KV
•.
4 / p .
b
/ c
2
Holmb 17 365NOTE3
1.Em*cndkwWbcaWrkm b 4
each and dbdrl=aft3b.
ImeFdwwasw"beab rhm4 G1 a
eoch end d Rie bolmom mL AAMaI Sped
3.AM�lteauedtolfeedw6h
�.ax�n•rr►isMs. E a
AuMNn1E ANCHORING LOCATION MOM NTERM
SHOW ON THIS SHEET
A W all a
E .. 15
c c 4
v L la 13 v
61 G2
is
SEENOIEI 11 p 14 SMMM2 F
6
• 12 1 14
G1 cs
c
ES b D
r
1 E IF
1 P 14L(MJ N.T.S.'1 ETERIOR JK1 URALG„RQSS�ECOM LFS 2Ke�dcMoeprryczx 1618842.6
3a_IL
i• N
�r o
. 1,.
: eLi
OE
ft . •
9.
it
R
�i
L
2rMAx 'r
O.a.OfP.) oypi
' N
y
s
MI
110.�Or00 *�
OoA}bwO11;PDf7
/Ag
m
TE ro 61M m. 2f7f � McMS W Pnm,► !,', ,`���,
(� &AI.ClfO aaWtATAN17.rlldf7.o
2 tD 4 to ADW)�tPhwm Hua
112. DATE A0ANOOR 0 JK PART fM AS3Q�� Q��!A . 1 TF i11 STM ED. 2Q}� FRAME /Y P.- —230,VdRoq R.J7C90
I" °1 ♦ xREWSKM ANC10i11MC InPE C�do 6/01YT
O Zola q.w.nuu.o..w aaw LTAwe Sma.
Sash IdIiUtN�IM-AoriQt -1668 HaekaW -166Q SA
b
Y
W
o
` l
w
�1 a o
Lw 0 T +Nj
i
TLk
i i L ho jt�i
I V��wrTr
o L-177
a Q
�s 0
L-7.2r ty
�Wo;�
09!
�. "OAT a
T.,
IM
OC= 0
ao
1A1' 's,��allurMhq'4
,'►`�
{/gflUR wy�ir! % r
� .
PRODUM Pon
s s ie atom Kr. 201E Fac .ut ltarSoerlr MX P..a ►FNl11 j1`,,``+��.
Ott t3t6rr 69 91Y t11JftDNG TANt!! tt1C.
1 t TO 3I 1 EA 2a s FOC PA. Oft 250.Yarn. FL 3WO
COMPOMMPuot+.ae ats+W.91 7
.F1iP�c,A Na 0813
O>tas♦otw.smian+r t�+ruvArns i.ro_
•ONI VA"AMtxn0 amovne•*-a view*
f:Me 4" YO xm'
tete eea cw ^rna s7mzmv".40 719 At
ams Zi '�f+FN'OCL mB Od Sf1 Mf fl NLS CL 1
MGM �'
1 L of
ttlHl/llffff�� 1W 9l e N'�
% ��i� eoKY 'ql 7'J kl' a u L10L 'Mum OL 1 6 1•= 11111,� t ���
++� - iWW.J erfarfl 41 N •L.f10011d
+� Wr W
+ Alm V0Aqw0
111111s
o � F
0
< M
12 12,14-1212
I Igg 1 9
x 20.4 x
�1 EO V O W "lug •Owp�
r
9'9erpBmm-vumZ if VOW1 ma0•.ArPtilnuoalAfilfe9T�!lMI��lllxb�UlPlntl•Y1118NYiAHd�WfM�A�SwlA+paPN
R W R W Building Consultants, Inc.
B Consulting and Engineering Services for the Building Industry
C P.O.Box 230 Valdco,Fl.33595 Phone 813.659.9197
Florida Board of Professional Engineers Certificate of Authorisation No.9813
Pi-oductEvahlatioll
October J
Product
Category Sub Category Manufacturer Product Name
NewSouth Window Solutions Series 9000 Model 9550 Slider XO
Windows Horizontal Slider 4901 Oak Fair Blvd Impact Rated-HVHZ
Tampa,FL 33610 wl Flange
813 626-6000
Scope: Product Evaluation report Issued by R W Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for
NewSouth Window Solutions,based on Rule Chapter No.61G20-3,Method 1D of the State of Florida Product Approval,
Dept.of Business&Professional Regulation.
RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named
herein,
Umftattons:
1. This product has been evaluated and is In compliance with the 6th Edition(2017)Florida Building Code(FBC)including the"High
Velocity Hurricane Zone"(HVHZ).
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in the"HVHZ",this product complies with Section 1626 of the FBC and does not require an impact resistant covering.
4. When used in areas outside of the"HVHZ"requiring wind borne debris protection,this product complies with Section 1609.1.2.2&
R301.2.1.2.1.of the FBC and does not require an impact resistant covering.This product meets missile level"D"and includes Wind
Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2&R301.2.1.2.1.
5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction.
6. Site conditions that deviate from the details of drawing FL-16842.6 require further engineering analysis by a licensed engineer or
registered architect.
7. This product meets water infiltration requirements for"HVHZ".
8. See drawing FL-16842.6 for size and design pressure limitations.
Supporting Documents:
1. Test Report No. Test Standard Testinq Laboratory Signed by
TEL 02031488 TAS 201,202,203-94 Testing Evaluation Lab. William B.Shelton,P.E.
TEL 02031489 TAS 201,202,203-94 Testing Evaluation Lab. William B.Shelton,P.E.
TEL 02031566 TAS 201,202,203-94 Testing Evaluation Lab. William B.Shelton,P.E.
2. Miami Dade NOA Materials Testing
17-0712.04 Saflexo PVB Interlayer(Eastman Chemical Co.)
3. Drawing No. Prepared by Signed&Sealed by
No.FL-16842.6 RW Building Consultants,Inc.(CA#9813) ®1t®6ytrtApiBr,jB Lyndon F.Schmidt,P.E.
4. Calculations Prepared by �`� '�,^ �E fN *ice Signed&Sealed by
Anchoring RW Building Consultants,Inc.(CA#9813) Z p •® `�Lyn n F.Schmidt,P.E.
ASTM E1300 Glass Load Lyndon F.Schmidt,P.E. No 43409
5. Quality Assurance
Certificate of Participation issued by National Accreditation and
STATE OF dA1` Lyndon F.Schmidt,P E
Management Institute,certifying that NewSouth Window Solutions is '�(��••• �Ik` FL PE No.43409
t manufacturing products within a quality assurance program that complies spy�. •.L C�H i n,-- `.��� 1 011 2120 1 7
with ISO/tEC 17020 and Guide 53. Sheet 1 of 1 ��0dS ®0 Iff i,
e 01;2
r,
t•
k