Loading...
HomeMy WebLinkAboutBuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 10/02/2018 Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential x PERMIT APPLICATION FOR: Electrical T PROPOSED IMPROVEMENT LOCATION: Address: 8028 LINKS WAY Legal Description: POD 26 AT THE RESERVE PHASE 1 CYPRESS POINT LOT 39 (OR 1082-1233:2859-2062: 3016-379 Property Tax ID #: 3327-707-0043-000-6 Lot No. 39 Site Plan Name: POVER Block No. Project Name: DOVER Setbacks Front Back: Right Side: Left Side: DETAILED DESCRIPTION OF WORD: Run new dedicated circuit for 24KW trutankless water heater. CONSTRUCTION INFORMATION: Additional wor to Iee r orme un er t Is permit c ec a app y: LJ HVAC u Gas Tank E]Gas Piping _ Shutters Windows/Doors Electric ❑ Plumbing Sprinklers E Generator Roof Roof pitch Total Sq. Ft of Construction: Cost of Construction: $ 2266.84 OWNER/LESSEE: _ Name IDA DOVER Sq. Ft. of First Floor: _ Utilities: Sewer ! 1i Septic Address: 8028 LINKS WAY City: PORT SAINT LUCIE State:FL Zip Code: 34986 Fax: Phone No. 772-489-9190 ^� E -Mail: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) CONTRACTOR: Name: JOHN A. PANKRAZ Building Height:. Company: ELITE ELECTRIC AND AIR Address: 1691 SW S MACEDO BLVD City: PORT SAINT LUCIE State: FL Zip Code: 34984 Fax. 772-3702 Phone No. 772-340-3797 E -Mail: PERMIT@ELITEELECTRICANDAIR.COM State or County License: EC 13006036 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. L Q it ! D R Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential x PERMIT APPLICATION FOR: Electrical T PROPOSED IMPROVEMENT LOCATION: Address: 8028 LINKS WAY Legal Description: POD 26 AT THE RESERVE PHASE 1 CYPRESS POINT LOT 39 (OR 1082-1233:2859-2062: 3016-379 Property Tax ID #: 3327-707-0043-000-6 Lot No. 39 Site Plan Name: POVER Block No. Project Name: DOVER Setbacks Front Back: Right Side: Left Side: DETAILED DESCRIPTION OF WORD: Run new dedicated circuit for 24KW trutankless water heater. CONSTRUCTION INFORMATION: Additional wor to Iee r orme un er t Is permit c ec a app y: LJ HVAC u Gas Tank E]Gas Piping _ Shutters Windows/Doors Electric ❑ Plumbing Sprinklers E Generator Roof Roof pitch Total Sq. Ft of Construction: Cost of Construction: $ 2266.84 OWNER/LESSEE: _ Name IDA DOVER Sq. Ft. of First Floor: _ Utilities: Sewer ! 1i Septic Address: 8028 LINKS WAY City: PORT SAINT LUCIE State:FL Zip Code: 34986 Fax: Phone No. 772-489-9190 ^� E -Mail: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) CONTRACTOR: Name: JOHN A. PANKRAZ Building Height:. Company: ELITE ELECTRIC AND AIR Address: 1691 SW S MACEDO BLVD City: PORT SAINT LUCIE State: FL Zip Code: 34984 Fax. 772-3702 Phone No. 772-340-3797 E -Mail: PERMIT@ELITEELECTRICANDAIR.COM State or County License: EC 13006036 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAIN INFORMATION: DESIGNER/ENGINEER: Not Applicable !MORTGAGE COMPANY: _ Not Applicable Name: IDA POVER Name: -JOHN A, PANKRAZ ,,1 Add ress:8028 LINKS WAY Address: 6028 LINKS WAY City: PORTSAINTLUCIE State: City: PORT SAINT LUCIE State: Zip: Phone Zip: Phone: FEE SIMPLE TITLEHOLDER: _ Nat Applicable BONDING COMPANY: Not Applicable Name: Name: Address: 1691 SW S MACEDO BLVD Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property, A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recording your Notice of Commencement, Signature of as Agent for Owner � Signature of Holder STATE OF FLORIDA STATE OF FLORIDA COUNTY OF Sf, LuG 1 E COUNTY OF S r L u The forgoing instrument was acknowledged before me Theforgoing instrument was acknowledged before me this L day of 0 0-d 6 r"2. 20I � by this 2 day of _ O tl_D 3f- c ,204' by �04la Ptk.s�c2pr� Name of person making statement Personalty Known -- �G OR Produced Identification Type of Identification Produced 16 l ig o p.a--Ar- A -r L Name of person making statement Personally Known X OR Produced Identification Type of Identification MdNNI LENAE DEWiTT _+ =Notary Public — State of Florida , KONNI LENAE DEWYTT My Commission # GG 16691b Notary Public— Slate of Floritla , +" - Gommissi©n # GG E66915 y"' Comm. Expires Dec 10 2®21 n PE (Signature of Notar _ fond o aftlaryAssn, Mv Comm. Ex ires Dec 10, 2021 t' � ` 7Iatfonal Nolar A {Signature of Notary bi1>=_.5ta'te B��dl r $�r� Commission No. 661(doltS (Seal) Commission No. 6611,01,S-_ (Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev, $/2/17 rl A 'm l lS MOO IN �c 4 _ � "Al rl A 'm l lS Elite Flertiric & Air, Inc. Load Calculations Phone �— _ Email address-, Customer �BffIC : �!�1�-� _L�✓epi.-,-- Location : � h i �JkiS "4 ��-L ✓ � � �� a Existing Service Feeder Size: _ _ Existing Panel Size:'2_�1�� _ Alain ltreaker Size: � � - � Ntimber of Breakers n%.Oads -Y Sq. Ft. X 3 watts per sq. ft._. ......... .....:.. �, � 2 Z . watts Minimum 2 Appliance cir. @ ] Si1O watts(.�40 watts —Laundry cjr. v 1500 watts each „ .................. &f P__watts Range @ 8 kw-., .................. __10� 004i watts Dishwasher and disposal Q 1500 watts each...... 3 000 watts AR'all mounted Microwave @ 2000 watts, ... __ ctd ra watts Water heater @4�....,.,,. 2 _watts Dryer n 5 k w.. C10 2.2 watts E refiierator a)1500 warts .............. . �—watts .,.____.,.._.sprinkler Paw ....... ........ "Z.r�U ...... �, J 'watts ----Other ............... Dther ?�r, rices -?- fJC1LY tivatts ._ ...... /© �U watts (Other ............. watts Sub total_%�V atis __ Pmol pump.-........ .---Pool light ..... . ........ ....................... _ tleatpuMp...,._............. .............. ......... ..... Chlorine generator ...._...._.._ _ watEs Air bivwer........ --- Boattiif....... ...... .............. watts —tOoer ......... _--Other --_.,.__Other watts ........... watts --� First l ii ;fit w 10(1°/6.__,. Towl ............. ./�ur�6 was �9�z ._�., wa.� p'"aainder @ o .., o... ,,,, 40 ro X100° v& hca b5°% -/.-vans 7 waits 4 �" watts PrItPared by: ! Divided b f v 240 volts r Bate; AI"Ps trutankless Hot Water Outlet Connection (Red Arrow) Next, connect the outflowing Hat Water Supply main to the Outlet connection, indicated by the Red "Outlet Water" tag. This is accomplished in a manner identical to connecting the inlet supply, Turn on the Water suppiy to the system. Open a hot Water tap in the house to allow Water to flow. NOTE: Outflowing water will be cold at this point of installation. Waterwill not flow hot until electrical supply is connected. Verify that the inlet and outlet connections are leak -free, both With water flowing and with the Water flow stopped. Maintain water pressure and check for leaks for a minimum often (10) minutes. If a slight leak is noted at either of the stainless steel flexible line connection points, carefully tighten further with both wrenches as noted above. Pressure Relief Valve Neste that a temperature pressure and relief safetyvalve is not required according to national plumbing codes as instantaneous water heaters are not considered pressure vessels. The trutankless comes equipped With a mechanical thermal cut out and the copper manifold is not defined as a pressure vessel according to ASMI=, if your water lines are plastic piping or tubing (PVC,PEX, Etc.), a pressure relief valve rated to equal or less than the PSI rating of the tubing should be installed- T&P valve may be required to meet installation codes in your area. If one is required, install the pressure relief naive branched off the hot outlet side. The trutankless TR/TC unit plumbing connections are now completed. ELECTRICAL CONNECTIONS Tit: 36 kW TC: 33 kW 1 0 2 x 30 Agip A x' 44 Ga. 2 -Pole Breakers Copper TR: 29 kW TC: 25 kW <s1 i x 125 Amp 2 x :z Ga. _ 60 Amp SGa. ,-Pala Breakers Copier 2-Poic arcakers copper TR: 24 kW TC: 21 kW J , 3. ; iC ii; 2 x #2 Ga. 2 x 50 Amp � <;y6 Ga. .... Copper 2 -Pole Breakers Capper TR: 20 kW TG17kW 80 l x 80 Amp 2x#4 Ga. 2x40Fmp - IIx#8 Ga. 2-Poic Breakers Copper 2- ole Breakers Capper TR: 1kW TC; 122 kW 60 1x60 Amp 2x#c Ga, 2x30An-,p 4xysGa, 2 -Pole Breakers Copper 2 -Pole Breakers Copper ABOVE INFORMATION iS MEANT ONLY ASAGUIDELINEAND SHOULD NOT BE RELIED UPON TO GUARAPITEE SAFETY OF INSTALLATION OR CODE COMPLIANCE. ELECTRICAL WIRING SHOULD ONLY BE PERFORMED BYA QUALIFIED AND PROPERLY LICENSED CONTRACTOR. PLEASE ENSUREYOUR TRUTANKLESS MODEL IS PROPERLY WIRED ACCORDING TO LOCAL AND NATIONAL ELECTRICAL CODES- IMPROPER ELECTRICAL INSTALLATION COULf3 CAUSE DAMAGE TO PROPE'RTYAND MAY RESULT 3N PERSONAL INJURY OR DEATH. 20 INSTALLATION AND OPERATION GUIDE NOTE: Electrical service connection to the unit must be performed by a licensed contractor in accordance with all applicable National Electric Safety Codes, and all state/provincial and local electrical codes. WARNING: This heating apparatus is an electrically powered high voltage and high current device. It is intended to be installed by a qualified and licensed contractor only. Failure to install this unit in accordance with all applicable codes and requirements may result in personal injury or death. WARNING: Make sure the main power is [AFF before proceeding with the electrical service connection to the system. NOTE: We strongly recommend the use of copper conductors only. NOTE: Electrical connections should be made OhiLY afterthe water system is connected and is tested to be leak -free-, all appropriate fittings are installed; and the required AWG capper wires have been routed to the trutankless MODEL BR/BC !Nater Heater. Figure 5. wiring Connections. Ll, L2 (Red Arrow) & Ground (Orange Arrow) PRODUCT MODEL SETTINGS IMPORTANT: IDEAL PERFORMANCE OF THE TRUTANKLESS SYSTEM DEPENDS ON COMPLIANCE iAfITH THIS SECTION. POS 4 The DIP switch positions determine the performance parameters of the unit model. To ensure proper installation and system operation, POS 3 the unit must be configured using the dip switches settings specified in figure below and pictured in the table on the following page. Followingthese instructions and properly setting the DIP switches PSS at installation is extremely critical to the proper functioning of the system and will ensure ideal temperature rise and flow rate POS I maximums. ON OFF 21 truales, TR: 3E kW NG 4xs4Ga. TG 33 kW 2 -Pole Breakers Copper TR: 2kW TC: 255 kw 120 1x125 Amp 2x-2 Ga. 2x GaAmF 4x a5 Ga. 2 -Pole Breakers Copper 2 -Pole Breakers Copper TR: 24 kW TC: 21 kW2-Pole 1 x 100 Amp 2 x #2 Ga. Z x 50 Amp :z =C Ga. Breakers Copper 2 -Pole Breakers Copper TR: 20 kW TC: 17 kW ix80rmp 2x04 Ga. 2x40Amp 4x 98Gz. 2 -Pale 3reakeis Copper 2 -Pole Breakers Copper TR; 14 kW e0 Ix60Am F 2x»C Ga. ? x 3Q Amp ? x #S Ga TC; TC; 12 kW Breakers Copper 2•Pole Breakers - Copper COMPLETING THE INSTALLATION Confirm that the cold water supply main is turned on and that main power is connected to the unit. Replace the outer cover of the unit by lining up the cutouts with their corresponding pipe connectors, etc., and sliding it into place. Tighten the four (4) truss head screws (two at bottom of unit and two at top) until comfortably snug. Do not over tighten. Only now is trutankless MODEL BR/BC Water Heater ready for power -up and configuration. 0 Switch ON the main power circuit breakers. 22 INSTALLATION AND OPERATION GUIDE Switch ON the trutanktess unit circuit breakers. The controller powers up and the LCD screen displays the Startup screen for approximately 4 seconds. Open a hot water tap inside the building and allow it to flow for a minimum of two (2) minutes to purge air from HEX and protect unit from dry fire.. NOTE: The trutanktess unit must sense active water flow before it will allow the elements to heat. The LCD screen wilt be in lockout mode For a period of 120 seconds (2 minutes) while the water filts the heating tubes completely and the startup sequence completes. This completes the installation procedure, The trutanktess Water Heater is now in service. Operation is as • simple as opening a hot water tap. The unit will then begin heating water and can typically reach the set -point temperature in as little as 15-30 seconds. NOTE: Remember that water already in the supply line may be cold, so it may take somewhat longer forthe hot water to reach the faucet. Upon closing the hot water tap, the unit automatically returns to standby mode, That's all there is to operating your trutankless Water Heater! MAINTENANCE trutankless units have been designed maintenance free, yet periodic system checks are recommended. *In areas where the water hardness exceeds 180 PPM or 10.5 grains/gallons, a water softener or fitter needs to be installed and system checks, particularly of sedimentation accumutation in the flow sensor, should be carried out annually. Failure to install a filtration or softening system in areas with very hard water voids this warranty completely. SYSTEM CHECKUP WARNING. Always turn off the power circuit breakers at BOTH the main electrical panel and at the unit access panel! High voltage is present in the system. Personal injury or death can result if caution is not taken! The following items should be checked at each inspection: • Flow Sensor (paddle wheel clear of any sediment) Breakers (corrosion) • Inlet pipe connection (is it tight and dry?) * Outlet pipe connection (is it tight and dry?) • Flush Pipe Connection (is it tight and dry?) • Surrounding heater — Clean and free of dust and debris In case of an error message from the trutankless MODEL TR Residential Water Heater, turn off all the hot water faucets Wait for one minute. Turn a hot water faucet back on. if the error message persists, call your licensed contractor or authorized service technician. DO NOT ATTEMPT TO SELF-SERVICE THE UNIT! 23