Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
Florida Building Code Online Page 1 of 1 Business & Professional Regulation SCIS Home I Log in 1 User Registration ( Hot Topic Submit Surcharge Stats&Facts Publications j Contact Us BCIS Site Map Links ! Search Product Approval ra &USER:Public User Product Aooroval Menu>PmdurS or Aoolication Search>Application List . RECEIVED Search Criteria Refine Search OCT Q 4 2018 r Code Version 2017 F # 16460 Permitting Department Application Type ALL Product Manufacturer All St, Lucia County Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Applications FL# Tvve Manufacturer Validated By Sta FL16460-RS Revision ]ELD-WEN Locke Bowden P.E. ] pted] History Category:Windows (334)300-1800 Subcategory: Fixed -Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::2fi01 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Cooyriaht 2007-2013 State of Florida.::Privacy Staternent::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Cry Card sets CL W http://www.floridabuildinR.orp-/Dr/Dr app lst.asnx 10/4/2018 &800 Series product only but it does not meet the impact resistant requirement for windborne debris regions.Glazing Created by Independent Third Party:Yes is not an available option for the 900 Series product. 16660.7 07. HT 600, 700,2000,800,&900 HT Series sectional Steel sandwich type garage door 187" Series wide Limits of Use Installation Instructions Approved for use in HVHZ:No 7t I6660 R7 11 WindLoad Install Supplement rC Ft ;.pill Approved for use outside HVHZ:Yes X16660 R7 11 WL-.0600-0218-08 30-34-rE s.odf Impact Resistant:Yes Verified By:John E.States 51737 RECEIVED Design Pressure: +30.0/-33.9 Created by Independent Third Party:Yes Other: Evaluation Reports OCT 0 4 2018 Created by In-'/ _1���idependent t Third Party:Yes Permitting Department 16660.8 08. PAN C2011,C2015,C2410, PAN Series sectional pan type garage door 97"wide St. Lucie County R2410,02411,02415,02460, R2460,C2461,R2461,C2470, R2470,C2471,R2471,C2472, R2472,C2480,R2480,C2481, R2481,C2482,R2482,C2511, R2560,R2561,R2570,R2571, 112572,R2580,R2581,R2582 Limits of Use Installation Instructions Approved for use in HVHZ:No Approved for use outside HVHZ:Yes Impact Resistant:No Verified By: John E.Scates 51737 Design Pressure: +24.8/-28.0 Created by Independent Third Party:Yes Other:Glazing is an available option for all the Pan Series Evaluation Reports product listed but it does not meet the impact resistant I t tx;6u i:7 Af_f odpl ,a,t_i; requirement for windborne debris regions. Created by Independent Third Party:Yes 16660.9 09. PAN C2011,C2015,C2410, PAN Series sectional pan type garage door 97'wide R2410,C2411,C2415,C2460, R2460,C2461,R2461,C2470, R2470,C2471,R2471,C2472, R2472,C2480,R2480,C2481, R2481,C2482,R2482,C2511, R2560,R2561,R2570,R2571, R2572,R2580,R2581,R2582 Limits of Use Installation Instructions Approved for use in HVHZ:No d- In�t,all Supplement rC FL s.pdf Approved for use outside HVHZ:Yes 5-39-rE s.D0 Impact Resistant:No Verified By: John E.Scates 51737 Design Pressure: +35.0/-39.0 Created by Independent Third Party:Yes Other: Evaluation Reports I. ,f Created by Independent Third Party:Yes 16660.10 10. PAN C2011,C2015,C2410, PAN Series sectional pan type garage door 16'2"wide R2410,C2411,C2415,C2460, R2460,C2461,R2461,C2471, R2471,C2472,R2472,C2480, R2480,C2481,R2481,C2482, R2482,C2511,R2560,R2561, R2571,R2572,R2580,R2581, R2582 Limits of Use Installation Instructions Approved for use in HVHZ:No F 168¢0 R7 It WindLoad Install Suoolement rC F1, $.vdf Approved for use outside HVHZ:Yes '! 1,WC,11 R7 II WLL2000-01941-24-271--rl` s,y�lf Impact Resistant:No Verified By:John E.States 51737 Design Pressure:+23.9/-26.7 Created by Independent Third Party:Yes Other:Glazing is an available option For all the Pan Series Evaluation Reports product listed but it does not meet the impact resistant „ ,1t r,,,;,.0 requirement for windborne debris regions. Created by Independent Third Party:Yes 16660.11 11.PAN C2011,C2015,C2410, PAN Series sectional pan type garage do 16'2"wide R2410,C2411,C2415,C2460, R2460,C2461,R2461,C2471, R2471,C2472,R2472,C2480, R2480,C2481,R2481,C2482, R2482,C2511,R2560,R2561, 112571,112572,112580,112581, R2582 Limits of Use Installation Instructions Approved for use in HVHZ:No Approved for use outside HVHZ:Yes Impact Resistant Verified By: John E.Scates Design Pressure: 31.3/-34.9 Created by Independent Thirdrd Party:Yes Other: Evaluation Reports 1 2 3 4 1 5 6 7 8 FASTENER TO CONTINUE F PAST HEADER F 0 0 0 0 E MODEL NUMBERS E I o MODEL NUMBERS AVAILABLE OPENING2 X 6 GRADE 2 OR BETTER SOUTHERN HEIGHT PINE JAMBS. o PAN C2011 SERIES o SEE CHART FOR WOOD JAMB ATTACHMENT PAN C2015 SERIES TO BUILDING STRUCTURE. PAN C2411 SERIES PAN C2415 SERIES MAXIMUM ON D PAN C2511 SERIES CENTERSPAGNG D PAN C2410&R2410 SERIES PAN C2460&R2460 SERIES FIRST FASTENER4"t ,0 0 PAN C2461&R2461 SERIES ABOVE THE FLOOR J OPENING PAN C2471&R2471 SERIES WIDTH PAN C2472&R2472 SERIES PAN C2480&R2480 SERIES WOOD JAMB ATTACHMENT PAN C2481&R2481 SERIES _ C Budding Fastener Type E wt m CwW o CCemw Tension PAN C2482&R2482 SERIES sfn,afore worms sP�v so.&S to.a C PAN R2560 SERIES Min.2500 PSI to rapcon+ P1US) 2" 2.50. 5.W 24" 551 PAN R2561 SERIES 4000 PSI Concrete 114"wi r o�washer PAN R2571 SERIES Southern Pile 1 va OD'Lag Yt�r 1.50' 1.50' 1.5V 24• 620 PAN R2572 SERIES Spruce Pine Fr 1 118 OD w cher 1.50' 150' 1.50" 24" 482 PAN R2580 SERIES PAN R2581 SERIES NOTE:2X6 mounted to the vall must be Southam Pine Grade 2 or hear. PAN R2582 SERIES B L B John E Scates, P.E. 2560 King Arthur Blvd. Ste 124-54 Lewisville, Texas 75056 IMPACT RESISTANT Florida P.E. N 51737 FL#16660.11 Professional Engineer seal provided only for verification of wind load construction details. oElclgqm Wno "; 16 2"PAN 2000 SERIES WWII LOAD SECTIONAL DOOR A A 'i DESIGN PRESSURE-313'-34.9PSF 9U9N0/110:WL-2000-019431.35 tut. F V7 MAN BY: MVS Un ItUUC 4117114 til.ROC 327/19 ••OWPOININ MODELISI: See Sheet 3 11 r 3 DF 3 1 2 3 4 5 6 7 8 1 2 3 4 5 B 7 8 Door Width 16'-2"Shown NOTE: Track confgurotion above the door opening does not affect F See chart below for other 1he wind load rating of the doer. F Top Bracket door widths DETAIL A(sheet 2 of 3) Flag Bracket •... Detaf H(sheet 2 of 3) I 1 E E Jab Bracket rQe1ai'F(sheet 2 of 3) Door Height Slide Lock or Lock Bas 7' 0"Shown Detai G(sheet 2 of 3) Monual door locks are See chart required unless an automatic operator is installed. below for other 60+1-3" door heights 54"+/-3" p l i D 222"+l-3" i 1 Bottom Bradket End Hinges Strut&Strut Attachment Intermediate Hinge 4"+/-3" Detail C(sheet 2 of 3) Detail 8(sheet 2 of 3) Detail E(sheet 2 of 3) Detail D(sheet 2 of 3) 10+/-3" C This product has been evaluated per ANSI/DASMA 108 for static air pressure. Jamb bracket quantities shown are for use with grade 2 or better southern pine C This product has been evaluated per ANSI/DASMA 115 for large missile impact and cyclic wind pressure. jambs. Madel Number Supporting structural elements are to be designed by a registered professional engineer for specific wind loads. PAN C2460 8 R2460 SERIES PAN C2410&R2410 SERIES PAN C2461&R2461 SERIES NOME; PAN C2480&R2480 SERIES PAN C2471&R2471 SERIES Door Tam Total#of Struts Jamb HeightThese drawings are a PAN C2481&R2481 SERIES PAN C2472&R2472 SERIES PAN C2011 SERIES 6'4" 4 4 5 supplement to the installation PAN C2482&R24WSERIES PAN R2560 SERIES PAN C2015 SERIES instructions for a standard door PAN 82580 SERIES PAN R2561 SERIES PAN C2411 SERIES 6'3" 4 4 5 and only covers those B PAN 82581 SERIES PAN R2571 SERIES PAN C2415 SERIES 6'-V 4 4 6 procedures that vary from B standard door installation. If PAN R2582 SERIES PAN R2572 SERIES PAN C2511 SERIES 6'4" 4 4 6 these specific procedures ore Door Widths Desi n Pressures End Sde Center Center Center Impac 7-0' 4 4 6 not followed, the door may not Up To +psf psf Saes Hinges Styes Hinges Sties H Reastad Thi' 5 5 7 perform as designed. John E States, P.E. 2560 King Arthur Blvd. Ste 124-54 10'-7 49.7 55.5 Single 4 2 3 1 5 2 NO 74r 5 5 7 Lewisville, Texas 75056 17-7 41.5 -46.3 Single 5 2 5 2 5 2 NO Vr 1 5 5 7 IMPACT RESISTANT Florida P.E. # 51737 14'-2" 35.7 59.8 Single 1 6 3 5 2 7 3 NO Maximum section height is 21 in. 18'-7 31.3 34.9 Single 1 7 3 7 3 7 3 YES Maximum door height is 16 ft. Professional Engineer seal provided only for 18'-7 24.7 -27.6 Single 7 3 7 3 7 3 NO 9 FL#16660.11 verification of wind load construction details. 9 All doors, even those above the tested height, 20'-7 20.1 -22A Single 9 5 9 5 1 11 5 NO are available with jamb brackets or commercial 10'-7 31.3 -34.9 Single 4 2 3 1 5 2 YES full angle. The maximum spacing of the jamb I6z^PnSE�ONALD�WWakAAo A bracketS/track clips should be maintained. 71 DESIGN PRESSURE-31.1-349 PSF A 17,2" 31.3 34.9 Single, 5 2 5 2 5 2 YES 14'-7 31.3 34.9 Single 6 3 5 2 7 3 YES 21 1M WOfil WL-2000.0194.31-35 sect F This product is designed and sold by PSF. The AHJ or Engineer of Record is responsible for determining the mrle.w cure lE KIVS I IIATI e4/17/14 1 EL Oft 3.27118 PSF required for any given site. mi17° MODEL(ilr SeeSheet3 19l OF3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 1 B END STILES PUSH NUT 23"— TEK SCREW 16 Go Galvanized Steel 7/16" 4 END HINGE 1/4" X 3/4" Hex Washer Head See DETAIL K for push nut 14 Go Galvanized Steel Self Drilling (3 per Bottom Bracket) F Oo PUSH NUT placement. TEK SCREW F 7/16" 1/4" X 3/4" Hex Washer Head BOTTOM BRACKET See DETAIL K for push nut TEK SCREW o Self Drilling (6 per Hinge) 13 Go Galvanized Steel placement. 1/4" X 3/4' Hex Washer Head Self Drilling (2 per Bracket) NOTE: This screw should be ADJUSTABLE TOP FIXTURE 12 Goo located below the prepunched hole NUT PUSH o LOW HEADROOM TOP and go through the hinge,end sHe See I TEK SCREW and skin edge DETAIL K for push nut 1/4" X 3/4" Hex Washer Head BRACKET a a placement. Self Drilling (4 per Bracket) P„S-I NUI BOTTOM SEAL 7/16" DETAIL A LOW HEADROOM DETAIL B See DETAIL K for push nut DETAIL C E placement. — 23" TOP BRACKET 3 1/2" x 4" E STRUT E INTERMEDIATE STILE 18 Go 50 KSI Minimum 16 Go Galvanized Steel Galvanized Steel 4" JAMB BRACKET i 12 Go Galvanized Steel SLIDE LOCK or LOCK BARS oQo0 0 0 INTERMEDIATE HINGE1w 0 0 (not required with operator) 18 or 14 Go Galvanized Steel 32 0 0 o TEK SCREW TEK SCREWo a 1/4" X 3/4" Hex Washer D 1/4" X 3/4" Hex Washer Head BOLT & NUT Head Self Drilling (4 per ID / / TEK SCREW 1/4-20 x 5/8" Carriage Slide Lock Self Drilling (4 per Hinge) 1/4" X 3/4" Hex Washer Bolt & 1/4-20 Hex Washer DETAIL D DETAIL E Head Self Drilling (2 per DETAIL F Nat (1 per Jamb Bracket) DETAIL G End & Intermediate Stiles) WITH AND 00 000 NOTE: Details on some views omitted for clarity. a WITHOUT BRACE 00 00 O 0 0 0 Double end stiles and end hardware may be a a Q required on wider or heavier doors. o 0 0 C o0 00 o Maximum _ _ _-L 31„ FLAG BRACKET C 1/2" 2 1 RP RESIDENTIAL & LIGHT COMMERCIAL COMMERCIAL DETAIL K ROLLER BOLT COMMERCIAL For Standard, High For Standard, High There should be a 2" Diameter Nominol 5/16 x 1 5/8" Log Bolt For Low Headroom & Verticol Lift & Vertical Lifte space of maximum Eleven Boll Nylon or (4 per Flog Bracket). With 2" Track and With 2" Track and With 3" Track and 1/2" between the roller Ten Ball Steel with hub and the outside a Minimum Workable BOLT & NUT Single End Stiles Single End Stiles Single End Stiles 1 a-20 x 5 edge of the roller Shaft Length Shown. / /8"Track Bolt holder which is set by & 1/4-20 Hex Washer Nut o the push nut. (2 for Horizontal & 2 for B Vertical Track) DETAIL H L B o DOOR SKIN Min. Min. John E Scoter, P.E. of 1• Minimal 25 Co CoHonized Pointed Steel of !' 2560 King Arthur Blvd. Ste 124-54 o e o Lewisville. Texas 75056 ®e a o IMPACT RESISTANT Florida P.E. # 51737 0 0 o a FL#16660,11 Professional Engineer seal provided only for COMMERCIAL HEAVY DUTY COMMERCIAL HEAVY DUTY verification of wind load construction details. For Standard, High & For Low Headroom With BOLT&WASHER VERTICAL TRACK - 2"Nominal WOOD JAMBI P.1111111 111 Vertical Lift With 3" Track 3" Track and Double 5/16'x 1 5/e'Lag Bah&z'O.D. 13 Go Golvonized Steel tested. IBZ PAN2000 CTIOK I,D OR LOAD x 7/16'I.D.Flat Washer The vertical y be jamb 5ECTaNA-3IN- A and Double End Stiles End Stiles NOTE: Jamb bracket must be in 3'Nominal 13 Ca is also fasteners may be counter sunk �. 1 1' DESIGN PRESSURE-31J'-749 pSF A ALTERNATE BOTTOM BRACKETS direst contact with the 2x6(No approved as an alternate. to provide a flat mounting drywall allowed). surface. See jamb attachment OIIWUIM:WG2000-019431.35 Ikll F NOTE:The bottom bracket tested(shown in DETAIL C)is the lightest bracket NOTE:The flat washer is not required details on sheet 3 for attaching +� MU It MVS 111i1IM[ 4117114 M.MI6 Yrns lambs to the structure. W."RIIY/IMI available. far angle mount •ewPyrsu M01EL(i� SeeSheet3 MMlC2BF3 1 1 2 1 3 1 4 5 6 1 7 1 8 DOOR DATA Job Name Iloyd(Q-800142)-1 Serial Number C-1248553-W Door Model R2580 Door Width 12'-0' Door Height 7'-0' Springing 251 Weight DOOR WIDTH Lift Type 15Radius 7-1/2• Spring Cycle 10K LEFT HAND CABLE MIN, Life DRUM (RED) RIGHT HAND CABLE DRUM (BLACK) Coil Inside z' Diameter Wire Size 234 RIGHT WOUND SPRING LEFT WOUND SPRING Spring Length 27 (RED CONE) (BLACK CONE) Spring Turns 8 SPRING ANCHOR CABLE OF DOOR IPPT 717 Total Torque 571 (MIP) CENTER OF Drum 400-8 SHAFT Cable 1/8" Diameter RIGHT LEFT Cable Length 105 WOUND WOUND SPRING SPRING Center Line of gs Shan - 320 Sycamore St. STANDARD LIFT WITH (2) Wauseon,Ohio 43567 © Copyright 2013 SPRINGS ON 1 " TUBE SHAFT DOOR DATA 1-1/2"x 1-1/2"x 13 GA. ROOF PITCH TRACK Job Name Iloyd(0.800142)•1 GALV.STEEL HORIZONTAL STIFFENER Serial NumberC-1248553-W BACK ROOM HEADROOM Architect NA 12" Contractor NA HORIZONTAL TRACK SUPPPORT BY INSTALLER Distributor/ NA (TO SUIT) 3-3/4" Dealer OPENING MINIMUM Door Schedul NA WIDTH CLEARANCE t- GALV.STEEL TRACK TAPERED @ U- < 1/8"PER FOOT TO PROVIDE A Door Width 12-0' U WEDGE TYPE CLOSING ACTION. L O Door Height T-0" W W Z S 1Lift Type 15"Radius W O H O Z W Roof Pirch None U TRACK BRACKET @ 24"ON CENTER(TYP.) Center Line of 96 Shaft Headroom 14.5 3-3/4" Backroom 102 OPENING MINIMUM STANDARD LIFT WIDTH CLEARANCE Drawn By 8nbsp; JAMBS BY OTHERS JAMB SEAL (BY OTHERS) 12 GA.GALV.STEEL Date 8/21/2018 TRACK BRACKETS @ 2'-0"O.C. 1-1/2"x 1-1/2"x 13 GA. STEEL ANGLE 2"GALVANIZED STEEL TRACK O FASTENED TO TRACK BRACKETS WITH 1/4-20 x 1/2"HARDWARE. 5/16"DIAMETER 14 GA.GALV.STEEL ROLLER BOLT OR WELD HINGE FASTENED TO END STILE ALL CONNECTIONS4 WITH(4)1/4-20 X 3/4"SELF (TYPICAL) TAPPING TEK SCREWS. SIDE ROOM CLEARANCE GALVANIZED STEEL ` HORIZONTAL TRACK 2" STANDARD LIFT 320 Sycamore St. HORIZONTAL TRACK SUPPORT Wauseon,Ohio 43567 BRACKET MOUNT © Copyright 2009