FL* FL10674-R23
Application Type. Revision
-code Version 2017
Application Status Approved
Comments
Archived
Product Manuf icturer Owens Coming
Address/Phone/Emad One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg. owrnirrg.com
Authorized Signature Gieg Keeler
gre9• owenscornftM.corr►
Technical Representative Mel Sancrant
AddresWPhone/Emag 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
n-od.sancrarfc@owenscDmig.com
Quality Assurance Representative
Address/Phone/Email
wry ..Rooting
Subcategory Asphalt Shingles
Compliance Method C-valuedm Report from a Florida Registered Archlbact or a Licensed Florida
Professional Engineer
-7, Evaluation Report-Hardcopy Received
Florida Engine"or Architect Name who developed Robert J.M.Nierninen
�— the Evahration Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contact Expiration Date 05/162020
Validated By John W.Knemevich,PE
•:s_! Validation Checkltst-Hardcopy Received
of hep F►1067d. R3 C0I 2-03-7 01 C0I Nieririnen adf
Rderenaed Standard and Year(of Standard) 5tawdarA Year
ASTM D3161 2016
ASTM D3462 2010
weps:Itwww-londabuddowj rgJPrJPs�-aPp_dtiaspx?pcram=w6EVXQwtDgtBNbEY5V°,62boQT%2b6w7ahReglCQaucRBurEBFhs7WgZew%3d%3d Page 1 of 2
119118,9:14 AM
ASTM D7158 2013,
Equivalence of Product Standards
CarbTled By
Sections from the code
Product Approval Method Method 1 option D
Date Submitted 20/10!2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
Su of Products
FL s Model,Number or Hance Description
10674.1 Owens Corning Asphalt Rwt`tng 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles
Shingles and Starters
Links of Use In sta anion Ittsrudiom;
Approved for use in is VML,No EU0674 R33-U 2017 10 EIM& ER QC ASPHALT
Approved for me outside HVHZ:Yes SHnMGF F W-QUA= 4
ImpaId WA Verified By: Rabert3_M_NieFninen pE-59166
Desige Piemsure.-%/A Created by independent IWwd Party:Yes
Otlfes:Refi+er to tai,Section 5, eva6uation Reports
lit0674 R13 AE 2017 10 MAL ER OC ASPHALT
SEMMMAs FLF 067&RUPSif
Created by 31dependentThird Party:Yes
carrtaCt us::z3 aFFF Stare Fhsad t t 32399PhMP4 agFF: "/-IaZ4
The Sate cf F ida is an AA MD en pkl w.C,,,,* 'aW' °f FForida_::ERS:: ::Fwd sraeerrrent
Lader Florida Faw,email addrrsse5 ase public renonls If Ya+do cwt vqnt V-eamd address rrt3eased in respowe to a Pubic fe*wk.do Dot sena eFecberdc
awsta Flds e'ta.Y>�d mngetthe aFFoe M pboae or by 1tadCiooat maa.ff You have anY Qum.F>k�mntaKt890.#8T.I39S. MCtq SeCrSon
402M1a,F3Grida st AuMs ette Wft OcbiFber 1,lou,Hamm koved under Ctavwr 455,FSS.natst prate Va DqMUUWC wFm an owl ada,ess if they have
ow-Ift awas provided may be used furaftW comm nka ba w3h the NOW See norweWer emaa addresses are P"c record.V vw do not wish to stv*a per="
address,please prodde the Department vriih an emaa address whirls can be frade ave is the Fxd)re'M deeamFne¢Yon area Fbassee uederCtFa r 455,F°5„
C.6
ps*iiwww.floddabuilding.org/prlpr app_dtl.aspx,,paras=wGEVXQwtDgtSNbEySv%2boQT%2baw7ahReglCQ&wASixEBFhs7tvJgZew%3d%Sd Page 2 of 2
EXTERIOR RESFARCN&0 ,LLC
ofAidlmftt m agsm
353 CHRl5TiAN STREET,UNIT#13
■. OXFORD,Cr 06479
EVALUATION REPORT ' (203)262-9245
Owens Corning Waivation Report JMU-RS
One Owens Corning Parliaray FLWV44d3
Toledo,OH 43659 Date of bsuarA=02/06/2012
(740)4047829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governed the use of
construction materials in the State of Florida.The documentation subrnrtted has been reviewed by Robert Nieminen,
PM for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated-for compliance with the a Edition {203.7) Florida Waft Cade
sections noted herein.
DESaw im: Owens CoWWC Asphalt Roof Shingles
WELme: Labeling shall be In accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FOC 15072-7.3/R90L2.5.1.
CORTNUED CON PUANcs: This Evaluation Report is valid until such time as the named product(s) charges, the.
referenced Quality Assurance documentation changes,or provisions of the Code that relate to the.product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert N'ierninen,P.E.if the
product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
AuvonisEM mr..The Evaluation Report number preceded by the words'TrinityI EM Evaluated"may be splayed iii
advertising literature. 9 any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
bwEcnow Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through&
prepared br.
?'
Robert JAL ism,F.E. s `
Agrida RWOVUW Me MW4 RM40DCAANEZ983 � �" ,n'—1Q"/ZW IftdWrMsemasan
etecVW*a@yskpn ddoawmvL
CMVWMMCFkWBMMM
1. TrinitylERD dues not have, nor does it intend to acquire or will it acquire,a financial interest in any company manulacturft or
distributing Products R evaluates.
2 Tri nityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert ilierninen,P.E does not have nor will acquire,a financial interest in arty company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Weridnen,P.E.does not have,nor will acquire,a financial interest in any other entity invoived in the approval process of the
ProducL
5. This is a W&ft code evaluation. Neither Trh*IERD nor Robert Nieminen,P.E are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specificallvibrthat purpose.
i
T
ROOFING SttrSTBAS EVA DAWN:
L Saves:
Product CategOry: Roofing
Subs Asphalt Shingles
Cn pfran- Stater mic Owens Corrft Asphalt Roof Shhqjlles,as produced by Owens God,have demonstrated
compliance with the following sections of the a Edition(MM Florida MAdin Code and Florida Bddhig Cade,
Reside Volume through testing in aacoriiance with tate following Standards. Compliance is•subject to the
installation Requirements and Limitations/conditions of Use set forth herein.
L SMOAROW
Se Clan . Proverty Star art year
150725,8905.2.4 Physvcal Properties ASTM 03462 2010
2507.2.7.1,8405.2.6.1 Wind Resistance ASPM D3161 2015
LWZ7.1,R9051-6.1 Wind Resistance ASTM D7158 2011
3. REPEL:
Eel t:xamination Reference Date
UL U.0(CER9Rii) Physicals&Wind Resistance File 82453,Vol.3 02/15/2007
UE U.0(CER9626) Physicals&Wind Resistance 20320516-82453 05/16/2012
UL U.0 O S'F908) Physical Properties 06CA20M 04/18/2006
UL LLC(7St9628) Wind Resistance 11CA343M 02/18/012
UL LLC Ci5r9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL U.0 trST9628) Wind Resistance 4786126x"32 07/10/2014
UL LLC OST9628) Physical Properties Classification letter 02/13/2014
UL LLC(FST9628) Physical Properties Classitkurtion tette 10/02/2015
Wami-0ade(CER1592) FSC HVHZ Compliance Various NOAs Various
uL LLC(QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PiEOom DESCRitrri0 :
4.1
4.11 -Classic and Supreme are fiberglass reinforced,3-t3b asps roof shingles_
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
413 Devonshire—are fiberglass reinfor+ ,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefisition Duration, Duration Premium Cool, TruDefinMon Duration Designer Color
Collection,TruDefinition'Oakridge,Oakridge and WeatherGuard HP are fiberglass retnforcaed,laminated
asphalt roof shirCtes.
4.2 Hip&tutee Shin
4.2.1. Berks[vre Hip&Ridge Shingles,High Ridge,WeatherGuard HP Hip&Ridge Shingles,ProEdge Hip&Ridge
Shingles and DuraRidge""Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
43 Ames M Starier Str"rcus:
4,3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. UMrrATiONii:
5.1 This is a building code evaluation. Neither Trinity(ERD nor Robert Nieminen, P.E. ate, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use In FBC HVHZ jurisdictions.
53 Frye Classification is not part of this Evaluation Report,refer to current Approved Roofing Materials Directory
for fire ratings of this product
bcuw or Researcharxi Desgry UCC. Evak ation Report 0379MA21246
o ajJletiorimafae fin"WFIMM C=7)FBC NON-U EVALUAMM R106744W
Owens CoffftAsphatt FAMfW*%k s Revisions 10jt1VM7
Paipc2 of8
SA Mind Classifi tion:
5.4.1 All-Owens Corning asphalt shingles noted herein are Classified in accordance with FK Tables 3507.2.71
and R90S2.6.1 to ASTM DU61,Class F and/or ASPM D715%Gass H,indicating the shingles are acceptable
for use in all wind zones up to V„d = 150 mph (V„k = 194 mph). ReW to Section 6 far installation
requirements to meet this wind rating.
5.4.2 AD Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Phis noted herein are
Classified in accordance with FSC Tattles 1507.27,1 and 8905.2.6.1 to ASTM 03164 Gass F.indicating the
shingles are acceptable for use in all wind zones up to Vwe=150 mph(V„*=194 mph}. Refer to Section 6 for
installation requirements to meet this wind rating-
5.43
ating5.43 Classification by ASTM 07158 applies to exposure category S or C,as defined in FSC 1609.4,3,and a mean
roof hetht of 60 fiet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
S.4.4 Refer to Owens Corgi published information on wind resistance and installation limitations.
55 AH products in the roof assembly shall have quality assurance audit in accordance with F.A.C,Rule 6iG20.&
6. ImAuATWltli r
Wi Underbrne, rs
6.11 Undeiayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61620-3,per FSC 15072-3,150.2A or 890523.
6.2 Mph*Shingles:
62.1 installation of asphalt shingles shad comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FSC 1507.2.7 or 890524 with the following
exceptions:
Seri shw shingles require minimum five(5)nails per shingle.
Wird*HP shingles require minimum six(6)nails per shingle.
➢ ,Devonshire"'shingles require minimum six(6)nails per shingle.
StarW Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owers Cornu published information on wind resistance and installation limitations.
6.22 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FSe
1507.2 8 or R90S25. Staples are npt permitted.
62.4 Where the roofslope exceeds 21 units vertical in 12 units horizontal, special methods of fast eriutg are
required. See figures below for details_
&2_5 Minimum Hailing_Starter Strip Shingle and Starter Strip Plus:
Edq�eidr�oriE fleet —it�ic �
Sdf�edreeait ..��
'rr
r r r * ft
rrt,r i '`r
� f
Ir. _•►r
Shaw �
e�eeieege�ee .rrr t +eieews
t'e�.ored w ;
�e'S�Ps�+Ire�eew+�saoder�L�-at` ae+ar �er..aM'
Exxerioc Reser and .t Eieatetaiieiee Repot o37340tr=-lis
ofliWhoeieaefaeri9503 6n'MXrM 0)471 FOC NON4MMZ EVAWATNM FLU*74-FUS
hV3of8
6.Z.6 Mintntum Nailing—ClassIdO&Suprtune:
*mom= i �Ikar ,mom
O
6Z7 Mimmnurn Nailing—Ber>chirea':
.. ......... .
.w..
air
7--w-
ftwdard
r
Faswntng Paten Fad Patt rn
r••
rt�.�'.
Mansard or Steep Slope FazGaning Pattern
bftdW Roewch and Desk%UC. Cion ttpwrtO37-4WAZ=4W
C iceaeofitalioe r aea 6'"WMM C=7)MC NOH4Ma evAutwTUM RIM44M3
Owens UOMM Asphalt tioafgangles tte+rsion&101031aW
4 Pagesafs
T-04n-YEFUD
611 Minimum Nailing—DevoraMm"': 1
I
a
-
a�� r� s
��� lAiwdislllsiear sr s�
/r
seerOba +ca.ac
SUndard 6-Ntail Fastening Pattern Mansard or Steep Slone Fasbu ft Pattern
6.29 Minimum Nailing — Duration! TruDe midon" duration, Duration• Premum Cool & TruDtdbition`
Duration Designer Color Collection:
Standard Fostering Pamem 6-Nall Fastening Pattern
Mansard or Steep Slope Fastenft Pattern
Exterior Resean3r ar'd Qes�rr,4LC EvaluaOun Report 037440ALUAS
#AGOw2MftO'S CEI S'"EDfnM(209.7}FOC MO*MM EVALUATION 810674.113.3
Owens Owner Aspt*RODI'M saes Reversion&10/89/'2017
tomes of8
1
633 Woo&Rske WMSIN
63.1 Instailatim of W1erWiire I*p and Ridge Shingles, fth Rifte,W Guard*HP ft and Ridge
and Profxlge W ip & Ritie Shk Wes shall comply with the Owens Carnes current published instructiors,
usft four(4) nails per shingle. Installation of DwaRidge"` tarp & Ridge shall comply with the
Owens Corning current published instructions, using two (2) naiis per shingle. Refer to Owens Con*W
published information on wind resistance and installation limita wns,including the use of hand-sing far
wind warrantles.
63.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than WBC
35072.5 or R9W.U. Staples are not permitted
633 Minimum Nailing—B fthlree W5p&Ridge and High Ridge:
rM; l z
r
A
r
1
6.3.4 Minimum Naift—WeaftwQ ard•HP W*and Ridge:
A�
_ 1
1
F c k
I
BftW Researi*aW ftslin u c. b watim Road 09AM Qi t M
Certr,po dfI904&adml W,CI FF 6a=WMCW J=7)MC NON-WAQ WAUATIM h�3967a-Rt3
Owens Go�rninRAsphaltitooFS}asagiws Rew�iora&IOj09/20i7
Pgp7afg
635 Minimum Nailing-P vWp Nip&Ridge Stingim.
GUMdrd
63.6 Minimum Nailing—Duraf i ftWw Nip&Ridge Stdr4ow:
Note:The drawings below pertain to minimum,as tested attachment requirements. Refer to Owens Coming
published installation instructions for their minimum requirements.
a r
#i# '
4, 4 i g
7. MSEU :
7.1 labeling shall be in accordance with the requirements the Accredited Opality Assurance Agency noted
herekL
7.2 Asphalt shir40e wrappers shall indicate compliance with one of the required classifications detailed in FSC
Table 1507.2.7.1/R905.2.&L
As required by the Building Offiaal or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MM MACTUIt M RAIM
Contact the named QA entity for information on which plants produce products covered by Florida Rule 91-3 QA
requiremitni.'S-
10. QUAUTYASSURANCE ENmr:
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawaia-Dokania@uLcom
END OF EVAIMAT ION REPORT-
i
Saarefi ana uic Eton repot 037340A Z-0
a!` + e"EWftM PM7)Fet NON4WW EVA UAi'M axas74A13
Oweru CAsphaittEoof R�w"ssion8:1Q/39llGtJ'
P�eiatE
635 Mmmmm Nailing-ProEdge H*&Ridye
SUNdWS
liar i�=DirrtTias �� p
L4
M, 04
6.3.6 Weiurt n Na —DuraRidge"'I*&Ridge =
Note:The drawhW below pertain to minimum,as-tested attadmment regturements. Refer to Owens Gornft
published mon fistrucdons for their minimum requ'merter ts.
JIM
7. LA SMS
7.1 Labeling Shall be in accordance wilt the requirements the AccreditedCOaft Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall hxScate cornpaanm with om of the,required classificadons detailed in FSG
Table 1507.27.1 j R9OS2.6.L
& BURMGPMW AE'N(Iti
As required by the Suffdhtg'Of ictal or Authority Having Amisdic tion in order to properly evaluate the mon of
this proud.
9. liNltrtJFActtJRNIG PLAMM
Conbct the named OA entity for information on which plants produce products Covereed by Florida Rule 9W3 OA
requirmienls.
10. QEAMAMIRAMMENflM
UL LLC—QUA96M;(631)546-2458; ia@ul com
END OF EVALUATION REPORT-
aftnarameamband Vase%Uc. E as ikpat Oef7liQa0�td2�RS
ce rseafic.rear+�osm�n�r imWMOfffM7)MCmo"MJ!VAU)ATWM FUOSX =
owensceteftAsddtitoofSmneks �
t�oesafs
Certificate of Authorization No. 29824
17520 Edinburgh Drive
CREEK
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,C EDITION(2017)
Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued October 19,2017
P.O. Box 1404
Joplin, MO 64802
(417)624-6644 .
http://www.tamko.com
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: U nderlayments
Code Sections: 1507.1.1
Properties: Physical properties
PRODUCT DESCRIPTION
TAMKO®ASTM Slate ASTM D 6380, Class M,Type II underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKO®ASTM Tile ASTM D 6380,Class M,Type II underlayment constructed from an organic felt saturated
Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKO®Master ASTM D 6380, Class S,Type IV underlayment constructed from an organic felt saturated
Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
TAMKOO Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard® with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKOO No. 15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO®No. 15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO®No.30 ASTM ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKOO No.30 UL ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKOO TW Metal and Self-adhered, flexible,ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO®TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
T131314001.4 FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKD TAMKO BUILDING PRODCUTS,INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
TAMKO®TAM-FELT Alternate to ASTM D 226,Type I and Type II underlayment constructed from a non-
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturees installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMKOO TW Metal and Tile Underlayment and TAMK09 TW
Underlayment shall be 40°F.
b) The minimum application temperature of TAMKO®Moisture Guard(D shall be 35°F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKOO ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKO®TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof Coverings:
Metal Roof' Mineral Wood s
;Asphalt f:y Panea �Surfaded Roll ' Shingles and Slate C(ay ind
lsnd
Underlayment $hin lea Shin les ' =Raotm Shakes Shin les. -+Concrete Tl®--
TAMKO®ASTM Slate Y' N N N N Y
Surfaced Roll Roofing
TAMKO®ASTM Tile N N N N N Y
Underlayment
TAMKO®Master Smooth Y' N N N N N
TAMKO®Moisture Guard® Y N N N N N
TAMKO®No.15 ASTM
Asphalt Saturated Organic Y Y Y Y2 N N
Felt
TAMKO®No.15 UL Asphalt Y Y Y YZ Y N
Saturated Organic Felt
TAMKO®No.30 ASTM
Asphalt Saturated Organic Y Y Y Y Y Y
Felt
TAMKO®No.30 UL Asphalt Y Y Y N Y N
Saturated Organic Felt
TAMKO®TW Metal and Tile Y Y N N N Y
Underlayment
TAMKO®TW Underlayment Y Y N N N N
TAMKO®TAM-FELT Y N N N N N
Notes: 1)Open valley applications per 1507.2.9.2
2)Wood shingles only
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
' CREEK TAMKO BUILDING PRODCUTS,INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
Enti Report No. Standard Year
PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995
ASTM D 4798 2011
PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 . 2012
PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a
UL LLC(TST9628) 13CAl2269 ASTM D 226 2009
TBP14001.4 FL12328-R8 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CD TAMKO BUILDING PRODCUTS,INC.
j'[ K TAMKO Underlayments
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6t'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
;,,PGPaY R 20 1 7.1 0.19
pp
No 74021 2:1 :SO
• r
04'00'
STATE OF .•��
��T"�•.;c� P: Zachary R. Priest, P.E.
Florida,`` Registration 021
Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
T131314001.4 FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.