FL# FL2569-1114
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived L11
Product Manufacturer Soprema,Inc.(Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville,NON-US 00000
(819)478-2400
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
(� Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert].M.Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W.Knezevich,PE
® Validation Checklist-Hardcopy Received
Certificate of Independence FL2569 R14 COI 2018 01 COI NIEMINEN.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D4798 2011
ASTM D6163 2008
FM 4474 2011
FRSA/TRI April 2012(04-12) 2012
UL 1897 2012
Equivalence of Product Standards
Certified By
I
I
S �
Sections from the Code
I
Product Approval Method Method 1 Option D
Date Submitted 02/12/2018
Date Validated 02/14/2018
Date Pending FBC Approval 02/17/2018
Date Approved 04/10/2018
Summary of Products
FL# Model,Number or Name Description
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL2569 R14 II 2018 02 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
Approved for use outside HVHZ:YesiR 4.odf
Impact Resistant:N/A Verified By:Robert Nieminen,P.E.PE-59166
Design Pressure:+N/A/-150 Created by Independent Third Party:Yes
Other:1.)Refer to ER Section 5 for Limits Evaluation Reports
of Use.2.)The design pressure noted FL2569 R14 AE 2018 02 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
herein pertains to underlayment systems R14.odf
used beneath adhesive-set tile systems. Created by Independent Third Party:Yes
Refer to ER Section 5.6.4 for details.
® NeM
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-087-1824
The Sate of Florida is an AA/EO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statemelrt::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address leased in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455,F.S.,please dick here.
Product Approval Accepts:
Credit Card
Safe .,•.
I
5 �
NEMO I etc.
Certificate of Authorization#32455
353 Christian Street,Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
REPORTEVALUATION
Soprema,Inc. Evaluation Report 518010.06.09-1112
1640 rue Haggerty 171-2569-1114
Drummondville,Qu6bec J2C 5P8 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 12:02/12/2018
SCOPE:
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products;described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to
the product(s),the Quality Assurance or the production facility iocation(s). NEMO Ietc. requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M.Nieminen,P.E. The facsimile seal appearingwasauthorized byRobert
Florida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E.on 02/12/2018.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEW ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
i
ONEMOletc.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments,as produced by Soprema, have demonstrated compliance with the
following sections of the a Edition (2017)Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth
herein.
2. STANDARDS:
Section Pr
operty Standard.' Year
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012 2012
FRSA/TRI April 2012(0412) Physical Properties ASTM D6163 2008
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Enti Examination Reference:. Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.042 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-111 04/18/2007
ERD(TST6049) TAS 103/TAS 110 S7120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 S13190.02.09-111 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970 S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.141 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
PRI(TST5878) Physical Properties SOP-06402-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12).
4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths;36 and 45 inch; meets ASTM D1970.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls;meets ASTM D1970.
4.4 Lastobond Shield HT is a self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof
underlayment;meets ASTM D1970.
i
NEMO ETC,LLC Evaluation Report S18010.06.09-R12
Certijlcate ofAuthorizatlon#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12:02/12/2018
Page 2 of 8
r
ONEMOletc.
4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths;36 and 45 inch;meets ASTM D1970.
4.6 Lastobond Pro HT-S is a self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof
underlayment;meets ASTM D1970.
4.7 EnviroShield is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment;meets ASTM D1970.
4.8 Lestobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;
meets ASTM D1970.
4.9 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen
roof underlayment;meets ASTM D1970.
4.10 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;
meets ASTM D1970.
4.11 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof
underlayment;meets ASTM D1970.
4.12 RESISTO LB1236 is a self-adhering,glass-mat reinforced,sand-surfaced, SBS modified bitumen roof underlayment,
with a 36-inch sheet width; meets ASTM D1970.
4.13 PrimeSource Grip-Rite Eave & Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment,with a 36-inch`sheet width; meets ASTM D1970.
4.14 RESISTO LB1244 is a self-adhering,glass-mat reinforced,sand-surfaced, SBS modified bitumen roof underlayment,
with a 44-inch sheet width;meets ASTM D1970.
4.15 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12).
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are, in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers.
TABLE It ROOF COVER OPTIONS
Slate or'
Asphalt Nail-On Foam-On. Composite-
underlayment Metal Composite
Shingles Tile .,,Tile Shakes&
Slate
Shingles
Lastobond TU HT Yes - Yes Yes Yes Yes Yes
See 5.5.1
X'Lastobond-Shield/Pro HT-N/ Yes, No No No Yes Yes
%RESISTO*SA SMOOTH PLY 40
Lastobond Shield HT Pro HT-S Yes No ` " `No Yes; Yes Yes: ,
EnviroShield Yes:; No .. No :Yes Y,es;'" Yes
i
NEMO ETC,LLC Evaluation Report 518010.06.09-R12
Certificate ofkuthorizattan#32455 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12:02/12/2018
Page 3 of 8
I
J .
I
ONEMOjetc.
TABLE 1: ROOF COVER OPTIONS
Wood or '
Asphalt Nail-On foam-On Composite Slate or
Underlayment. Metal -Composite,
Shingles Tile Tile Shakes&
Slate
Shingles.
Lastobond Eaves Protection Sheet/ Yes No No No Yes Yes
Lastobond 195
Lastobond ECO /RESISTO LB1236,
Grip-Rite Eave&Valley Protector/ Yes No , No No.- °t Yes Yes
RESISTO LB1244
Lastobond Smooth Seal HT Yes
Colphene FR GR Yes', 4,Yes Yes
No, Yes Yes
See 5.5.1
5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations.
TABLE 1A:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS'
Adhesive "
Florida Product Approval Undetlayments.:
Dow TileBond' FL22525 Lastobond TU HT
ICP Adhesives Polyset®AH-160 FL6332 Lastobond TU HT or Colphene FR GR
5.6 Allowable Substrates:
5:6:1 Direct_Bond-to Deck:
171, Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
1.61236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41 primed
Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
➢ Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming
with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours.
➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of
the self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
1.61236, Grip-Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on
the systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional
and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D,
Testing Application Standard TAS 114,Appendix J or UL1807.
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approvalfor Overturning Moment Resistance Performance.
MEMO ETC,LLC Evaluation Report S18010.06.09-1112
Certftate ofAuthorizatlon//32455 6TM EDMON(2017)FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12:02/22/2018
Page 4 of 8
I