Loading...
HomeMy WebLinkAboutProduct Approval-FL18355-R4 `•� 10/116018 Florida Building Code Online *ff+4 oqG AA Ii't f yy • ,° .7' • F / {tj;�_ s� ' �'`.-..: *`: .- ,,,.�, „,s•. '.-f Kas ito ., ,uB f DBPR15tp l9ISI4 t6kturrnimit BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I Contact Us I BCIS Site Map I Links I Search Florida - ' b r ` , I Product Approval -� - USER:Public User Lrwmmo Product Approval Menu>Product or Application Search>Application List>Application Detail ' x.°y Arm RFCElf Oaf EL18355-R4 �� Application Type Revision OCT 10 1019 Code Version ' 2017 Pe Application Status Approved tI th�9 De �ucle C°Part„, ty ent Comments Archived (L Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 ALZ Joplin, MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.com 141 Authorized Signature Kern Eden kerri_eden@tamko.com Technical Representative Kern Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 01/07/2019 Validated By Locke Bowden P.E. ✓J Validation Checklist-Hardcopy Received Certificate of Independence FL18355 R4 COI TBP15001.4 2017 FBC Eval Report Shingles final.pdf Referenced Standard and Year(of Standard) Standard ea ASTM D 3161 2016 ASTM D 3462 2010 ASTMD D 7158 2011 TAS 100 1995 Equivalence of Product Standards Certified By Approved Testing Lab FL18355 R4 Equiv UL letter for standards for FBC 2017.pdf https://floridabuilding.org/pr/pr app_dfl.aspx?param=wGEVXQwtDquvosrHazGXQW83MPT3uofKzD1M2Xu9wuWmY6PQIJIukQ%3d%3d 1/2 10/11/2018 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option Date Submitted 09/25/2017 Date Validated 09/27/2017 • Date Pending FBC Approval 10/08/2017 Date Approved 12/12/2017 Summary of Products FL# Model, Number or Name Description 18355.1 Glass-Seal, Elite Glass-Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles Heritage, Heritage Premium, Heritage Woodgate,Heritage Vintage, Hip and Ridge,and Vintage Hip and Ridge Shingles Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL18355 R4 II TBP15001.4 2017 FBC Eval Report Shingles Approved for use outside HVHZ:Yes Impact Resistant:N/A Verified By: Zachary R.Priest PE-74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL18355 R4 AE TBP15001.4 2017 FBC Eval Report Shingles fina1,01 Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employencopyrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity,Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487,1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: 1Kr4 10-1 . . . . ' Credit Card Safe SecuritytdErRicS' • https://tioridabuilding.org/pr/pr_app_dt.l.aspx?param=wGEVX0wtOguvosrHazGXQW83MPT3uofKzD1M2Xu9wuWmY6PQIJIukQ%3d%3d 2/2 „ , . 1I �” Certificate of Authorization No. 29824 r. REEK17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6TH EDITION(2017) Manufacturer: TAMKO BUILDING PRODUCTS Issued September25, 2017 220 West 4th Street Joplin, MO 64801 (417)624-6644 Manufacturing Plants: Joplin, MO Phillipsburg, KS Frederick, MD Dallas,TX Tuscaloosa,AL Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995 ' PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995 UL LLC(TST9628) 02NK9507 ASTM D 3161 2016 UL LLC(TST9628) 04NK24366 ASTM D 3462 2010A UL LLC(TST9628) 05NK28006 ASTM D 6381 2008(2013)e1 UL 2390 ASTM D 7158 2011 . UL LLC(TST9628) 06NK03898 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 08CA59132 ASTM D 3161 2016 UL LLC(TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 10CA50498 ASTM D 3462 2010A UL LLC(TST9628) 10CA64882 ASTM D 3161 2016 UL LLC(TST9628) 11NK14014 ASTM D 3161 2016 ' ASTM D 3462 2010A UL LLC(TST9628) 12CA24551 ASTM D 3161 2016 UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e1 UL LLC(TST9628) 4787043752 ASTM D 3161 2016 UL LLC(TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC(ANE11669) TBP15001.3 Calculations 2017 TBP15001.4 FL18355-R4 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61020-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. F.. CREEKTAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC PRODUCT DESCRIPTION Elite Glass-Seal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4"x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Heritage® 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Joplin, Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Vintage® 17-1/2"x 40",ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage®Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.4 FL18355-R4 Page 2 of 11 This evaluation report is provided for State of Florida product approval under-Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I • CREEKTAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC INSTALLATION Elite Glass-Seal® Basic Wind Speed(V„it): Max. 194 mph (Frederick, Joplin& Basic Wind Speed (Vasa): Max. 150 mph Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Glass-Seal new construction; Min. 15/32 in. plywood existing (Frederick,Joplin (Non- construction. HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAILS -. .-1" NAa, il,i.�ng`- ----- ------ ----------------- �---------_....- ._ 6-7/8'1 5-118" Butt Edge Figure 1. Elite Glass-Seal&Glass-Seal 4 Nail Pattern (Non-HVHZ only) NAILS Area Nailing _ - - _ - - _, T 6-7/8" 5-118" Butt Edge Figure 2. Elite Glass-Seal&Glass-Seal 6 Nail Pattern TBP15001.4 FL18355-R4 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply-warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREED TAMKO BUILDING PRODUCTS r � Asphalt Shingles TECHNICAL SERVICES, LLC Heritage® Basic Wind Speed (V„it): Max. 194 mph (Dallas, Frederick,Joplin, Basic Wind Speed (Vai): Max. 150 mph Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Heritage®Premium new construction; Min. 15/32 in. plywood existing (Dallas, Frederick construction. Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 15/32 in. plywood or wood plank for Heritage®Woodgate new construction; Min.7/16 in.OSB existing construction. • (Dallas&Frederick) Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation (HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. FASTENERS NAIL ZONE COMMON fr BOND I 6-1/8" EXPOSURE 5-5/8" L. 1 \ I '11. 11.1 I1 12-1/2"--- J4---- 12-3/8" --►J4 12-1/2'1--øj 14-1" Figure 3. Heritage®, Heritage® Premium, and Heritage®Woodgate(Dallas) 4 Nail Pattern (non-HVHZ only) FASTENERS /NAIL ZONE diN COMMON BOND fi1 _ 6-1/8" EXPOSURE 5-5/8" I..._ \ \ i \ i I 1=-111 14--7-1/2' 7-1/2"-411- 7-318" 7-1/2"-11+1F-7-1/2"-1101 14-1" Figure 4. Heritage®& Heritage® Premium 6 Nail Pattern TBP15001.4 FL18355-R4 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. , ..„.., lc'. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC NAIL ZONE/ 77.M tAaSTENERaSm• ' • COMMON BOND 7 - T . .1 60/8" , . . 1 \ .E)(POSIJRE5/8": 41,1 10-71/221•14-7-1/2'473/814447112+7-101.1 141,-,1" Figure 5. Heritage®Woodgate 6 Nail Pattern ! ! ! ! --,-h"1114--12-1/211- 1 , , 1 14-la-1/2"---).!1"1"14- . . • 1 I 1 i IR] Common Bond g FASTENERS ' , 6 t to a '9 a Lo x +III \ \ \ ZO 6 4- I 1 39-3/8' ). I Figure 6. Heritage®, Heritage®Premium, &Heritage®Woodgate Alternate 6 Nail Pattern ( PAINT- JNAIL:ZONE i;. .-----.- 7.--"-------..: EDGE OF :,.... ,6-118 . ' .COMMON", , A ,„, .,. ,, BOND' -- - EXPOSURE • . . _ .55/81!: ACCEPTABLE - -"-FASTENER:LOCATION', DO NOT FASTEN ALONG.-ED GE:OF , COMMON'BOND: ;PREFERRED •:-. .:FASTENER- , LOCATION Figure 7. Heritage®(Tuscaloosa) Expanded Nail Zone Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above TBP15001.4 FL18355-R4 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. P- GREEK TAMKO BUILDING PRODUCTS CREEK Asphalt Shingles TECHNICAL SERVICES, LLC Heritage®Premium Basic Wind Speed(V„it): Max. 194 mph (Frederick) Basic Wind Speed(Vasil): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. . Installation (HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS COMMON BOND t W-7" \ T EXPOSURE 5" . 1 II� 11" 12" "'—►� I' —014-- —+---11 --� 14-1" Figure 8. Heritage®Premium (Frederick) 4 Nail Pattern (non-HVHZ only) NAIL ZONE/ FASTENERS /COMMON BOND 1 51/2" EXPOSURE 5" i l I� 1��L -91/2' 3' 9"--41-34I4-91/22=-01I.1-1 Figure 9. Heritage®Premium (Frederick) 6 Nail Pattern • TBP15001.4 FL18355-R4 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC • Heritage®Woodgate Basic Wind Speed(V„it): Max. 194 mph (Frederick) Basic Wind Speed (Vasa): Max. 150 mph Deck(Non-HVHZ): - In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction., Underlayment: In accordance with FBC requirements. ' Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS COMMON BOND �- T 5-112" EXPOSURE 5" J. 1 1j ar111 14— 11" -►�-12-318"-'- 11" --01 1-1" Figure 10. Heritage®Woodgate (Frederick) • 4 Nail Pattern (non-HVHZ only) NAIL ZONE/ /COMMON BOND FASTENERS471 t 5.1/2" EXPOSURE 5" .L 1, 1"--11 14111- 9-1/2" 3'I►h-9-3/8" 0143 9-1/2".41 l-1° Figure 11. Heritage®Woodgate (Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles • TECHNICAL SERVICES,LLC Heritage®Vintage® Basic Wind Speed Nun): Max. 194 mph (Phillipsburg) Basic Wind Speed(Va&j): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; • Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope:- 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"5 Nail Pattern"or"6 Nail Pattern"detailed below. N Off' 1Jgmart rxposure 2 NO:hw z NvtCh 010 Nail one 17.1/2' S' Exlposu re III; 9-1 AV 9-111` r 1 9-1M'--►�—9-1i' T 1 • --163/1' 10.3M' Figure 12. Heritage®Vintage® 5 Nail Pattern (non-HVHZ only) Exposum Notdi Zane 17-lir Boixdutn 4-r-I 7-3/r Pig 74.fr 741x' 7 ur —7-arr mtr 1- ■ g7/1--.1 "1 SW 161 r tutu• Figure 13. Heritage®Vintage® 6 Nail Pattern TBP15001.4 FL18355-R4 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. GREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC Hip&Ridge Basic Wind Speed (Vain): Max. 194 mph (Frederick&Joplin) Basic Wind Speed (Vasil): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction prevailing wind Start 5-1/8" exposure here- �•� slimmimk 410.4 nl ‘0 • >ris.r.I.L� •�,�•.,fy. �.1.�• S ..41.1,110 Figure Figure 1 here 5-1/8" exposure e11 6\f‘!;:\ „- Fastener Fastener r'L 5- " '-5-5/8" Figure 2 �� Figure 3 1/4" Figure 14. Hip& Ridge (Frederick&Joplin) TBP15001.4 FL18355-R4 _ Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. . . . F.,.. TAMKO�°�0�����0�~0�r PRODUCTS ��`8���0��0�~0�� Asphalt Shingles r.4 ,;:. -' TECHNICAL SERVICES, LLC Vintage®Hip&Ridge Basic Wind Speed(Vit): Max. 194 mph (Phillipsburg) Basic Wind Speed(Va ): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed mm . 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Mm .7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and-in accordance with FBC requirements. Installation: Installed with 5 inch exposure in accordance with the FBC and manufaduna/npubl|ohodinata||a1ion instructions. The direction of the exposed end shall be away from the prevailing wind. II Direction of prevailing wind Start 5" exposure I here ��.. 103' here laranik 0,4%04 1 111111411C .0°-"0/400140.2.7 ,01.04- loir"lige2 Inl 141101101111 I Start 5" exposure Figure 1 1" :w g -\ ~ - \~~^ ` --- � � lks 's ` �J �������r Fastener '- �^�� -z-uu:" ' -5-1/8» \ Figure 2 ^^^ Figure 3 Figure 15. Vintage®Hip & Ridge(Phillipsburg) . TeP15001.4 ru8355-R4 Page 10o,11 approvalThis ort is provided for State of Florida product underRule 61G20'3The manu��uupwxa noU�CoEsK Technical|Svaluation —'.Ulofonypmduotchongosnrqualityassv,ancoohnnOonththe duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. • COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6"'Edition (2017)as evidenced in the referenced documents submitted by the named manufacturer. _toittrrrri, YRp,F g �P� • •• 9/ ee, .` G , ENS - s 2017.09.25 No 74021 1 1 :31 :41 - 1 • - h.p�a M1RNntPoeu 7� -04'00' 1.0:• STATE OF :11-/:: : ., •..A• 1.0.•P:r�� • Zachary R. Priest, P.E. Florida Registration No. ,,,",,S/0NAL �``,, Organization No.ANE11669 1 �rrrntttt CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP15001.4 FL18355-R4 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. - . . 41) September 8, 2017 TAMKO BUILDING PRODUCTS INC 220 W 4TH ST ~ . POBOX 1404 JOPUN, MO 64802 �mEdition Our Reference: FloridaBuilding Code—Building ui|di ng . Dear Ms. Eden, Per your requestan evaluation of your submitted list of standto comre the reference year of the standard ait is prescribed in the 2017 Florida Building Code —Building 6th Edition (2017) and compared to the 2014 Florida Building Code, 5th Edition. A"statement....that product has not been affected by changes made to the Florida Building Code since last approval" has been requested by the manufacturer. Please review and utilize the table below to suffice this request. Standards Reference Table Product UL File FBC 2014 FBC 2017 Equivalency Technical Reference Reference Remarks ASTM D3161 R3919 ASTM D3101-09 ASTM D3161/D3161M -16 Yes No remarks ASTM D3462 R2819 ASTM D3462-09 ASTM D3402/O3482K8-1OA Yes No remarks ASTM D7158 R2919 ASTM D7158-08d ASTM D7158/D7158M—11 Yes No remarks UL 1897 R3225/R18590 UL 1897-04 UL 1897-12 Yes No remarks Under UL's on-going Follow-up Service, the manufacturer is authorized to use the UL's Listing Marking on such products, which comply with the Follow Up Service Procedure document and any other applicable requirements of UL. Only those product .vxhinhpropadybenrtheLebormtmhao' LiotingK8orking. aneoonoideradaaUotodby UL. furtherFor det�i|�mbnutth�ounentcm��omUunmpu�UohedforTmnnhoBui|ding �roductn |nc' p�aomoeeUL's | online certification directory found at www.ul.com. If you have any further questions about this information, please feel free to contact the undersigned. Very truly yours, Reviewed by: WILLIAM MARSHALL(ext. 42735) ALPESH PATEL42522) EnQineahngAsooc�te Lead (ext.Staff Engineer UL LLC s3apnnxstcnRoad,Northbrook,uawo*zaoyoUSA T:o4r.2r2.onon/F:mn.2,z.81uy/W:uunm Certificate of Authorization No. 29824 17520 Edinburgh Drive 3.- Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6TH EDITION(2017) Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued October 19, 2017 P.O. Box'1404 Joplin, 2 (417)624 6644 RFCFI'O O http://www.tamko.com (71.2 z; Pe"�rtti 20/ ;. Quality Assurance: UL LLC(QUA9625) St Gu eSOU eDt SCOPE 144 Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1 Properties: Physical properties PRODUCT DESCRIPTION TAMKO®ASTM Slate ASTM D 6380, Class M,Type II underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. TAMKO®ASTM Tile ASTM D 6380, Class M,Type II underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. TAMKO®Master ASTM D 6380, Class S,Type IV underlayment constructed from an organic felt saturated Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For use in non-HVHZ only. TAMKO®Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane Guard® • with a mineral surfacing and a removable release film on the adhesive side and removable selvedge release tape. TAMKO®No. 15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with.asphalt. Organic Felt TAMKO®No. 15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO®No.30 ASTM ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO®No.30 UL ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO®TW Metal and Self-adhered,flexible,ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. TAM KO®TW Self-adhered, flexible, ASTM. D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. TBP14001.4 FL12328-R8 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ' ---, m�x�om�0NGP���Cm� �� CREEK . TAMKoUndeduvmo�o r TECHNICAL SERVICES, LLC TAMKO®TAM-FELT A\harnatahoASTN1D228.Typo |ondType \| undodaymentconatmutedfromanon' perforated organic felt that is saturated with asphalt. APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall Ueconstructed ofclosely fitted plywood sheathing for new nrexisting oonatruotion� Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8^ gap at abutting joints. The minimum application temperature shall be 50°F except as follows: a) The minimum application temperature of TAMKOO TW Metal and Tile Underlayment and TAMKOC)TW Underlayment shall be 40°F. b) The minimum application temperature of TAMKO®Moisture Guard®shall be 35°F. The minimum roof slope shall be in accordance with FBC requirements except as follows: a) The minimum slope of TAMKO®ASTM Slate Surfaced Roll Roofing shall be 2:12. Underlayments shall be exposed in accordance with the manufacturer's nocommondoUone, but in no case shall exposure d 30 days Exception: TAMKO®TW Metal and Tile Underlayment may be exposed for a maximum 90 days. Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. All roof coverings shall be mechanically fastened through the underlayment to the roof deck. Allowable Roof Coverings: Metal Roof Mineral Wood Asphalt . Panels and Surfaced Roll Shingles and Slate Clay and unde,|aymwru Shingles Shingles Roofing Shakes Shingles Concrete Tile TAMKOC)ASTM Slate y, N N N N Y Surfaced Roll Roofing TAMKO®ASTM Tile N w N N N Y unde,|aYmenu T/mmw%}C)xxaster Smooth Y, N N N N N TAMKO®Moisture Guard® Y N N N N N T/MKO0No.15 ASTM , Asphalt Saturated Organic Y Y Y Y N N Felt T»moKo®No.1euLAsphalt v y y y« Y N Saturated Organic Felt TAMNO®Nv.'oVASTM Asphalt Saturated Organic Y Y Y Y Y Y Felt , T/mnKO®No.onuL Asphalt y y v N Y N Saturated Organic Felt TAMmO®TW Metal and Tile y y N N N Y Underlayment TAMKO®1W Underlayment Y Y N N N N TvwmmO®zAM'FscT Y N N N N N Notes: 1)Open valley applications per 1507.2.9.2 2)Wood shingles only TBP14001.4 pU2328-R8 Page um4 isdvdo�O��ofFloridaproduct approvalunderRu�61G2e3 The manu�cm,u,shall notify CREEK --evaluation ��, —'.'u o'°nvp,ouvouchengovorq�u\)�yooxvrmnnochanges m h ,modur�ivnvo,whicxtxio report is valid.— installation, recommendedmhe,pmdm�aut�bu�s�at are not Th�ova�a�onn,pu�doeommoxpm000nrknp�wmn�n�. use, or 12i; Certificate of Authorization No. 29824 REEK 17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL. SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, Sr"EDITION(2017) Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued October 19, 2017 P.O. Box 1404 Joplin,MO 64802 (417)624-6644 http://www.tamko.com QualityAssurance: UL LLC(QUA9625) ( ) SCOPE Category: Roofing Subcategory: U n d e rl aym e n is Code Sections: 1507.1.1 Properties: Physical properties • PRODUCT DESCRIPTION TAMKO®ASTM Slate ASTM D 6380,Class M,Type II underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. TAMKO®ASTM Tile ASTM D 6380, Class M,Type II underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. TAMKO®Master ASTM D 6380, Class S,Type IV underlayment constructed from an organic felt saturated Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For use in non-HVHZ only. TAMKO®Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane Guard® with a mineral surfacing and a removable release film on the adhesive side and removable selvedge release tape. TAMKO®No. 15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO®No. 15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO®No.30 ASTM - ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO®No.30 UL ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO®TW Metal and Self-adhered,flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. TAMKO®TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. TBP14001.4 FL12328-R8 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. | . '` | . �����)���0~�0�� TAMm}mu|L�NGPRDDoUTS.U«� ���0��0�*0����^ TAMmoUnde,laymmms ��� TECHNICAL SERVICES, LLC TAMKO®TAM-FELT Alternate to ASTM D 226, Type I and Type II underlayment constructed from a non- perforated organic felt that is saturated with asphalt. APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall boconstructed cfclosely fitted plywood sheathing for new urexisting conatruotinn. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. The minimum application temperatre shall be 50°F except as follows: a) The minimum application temperature of TAMKO®TW Metal and Tile Underlayment and TAW1%O@>7W Underlayment shall be 40°F. b) The minimum application temperature of TAMKOO Moisture Guard()shall be 35°F. The minimum roof slope shall be in accordance with FBC requirements except as follows: a) The minimum slope of TAMKO®ASTM Slate Surfaced Roll Roofing shall be 2:12. Underlayments shall be exposed in accordance with the manufacturer's recommendetiona, but in no case shall exposure exceed 30 days Exception: TAMKOO TIN Metal and Tile Underlayment may be exposed for a maximum 90 days. Self-adhering underlayments may be adhered to primed or unprimed plywood substratesinthenon-HVHZ` All roof coverings shall be mechanically fastened through the underlayment to the roof deck. Allowable Roof Coverings: - Asphalt Panels}� � M�u mvv Surfaced...� ' M Wood �ngles u^| � Slate ���� `Clay arid ' Underlayment Shingles Shingles Roofing �` ` Shakes ' �`Shingles Concrete Tile TANIKJC)ASTM Slate \" N N N N Y Surfaced Roll Roofing TAMKO®ASTM Tile N N N N N v Underlayment TAM KO®Master Smooth v, N N N N N TAMKO®Moisture Guard® Y N N N N N T@moK[C)No.1eASTM - Asphalt Saturated Organic Y Y Y yu N N Felt . TAM KO®No.15 UL Asphalt y y y yu y N Saturated Organic Felt T/MKoC)No.30ASTM Asphalt Saturated Organic Y Y Y Y Y y Felt T/ummo®No.oouLAsphalt v y Y N Y N Saturated Organic Felt TAM KO®TW Metal and Tile v y N N N v Underlayment TAMKO®TW Underlayment Y Y N N N N TxnmnummTAM'FscT Y N N N N N Notes: 1)Open valley applications per 1507.2.9.2 2)Wood shingles only TaP14001.4 FL12328-R8 Page 2 of 4 This evaluation report is provided for State of Flridmd ct approval underRule V1ou0-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes o /i ssurance changes thh t the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. • CREEK E TECHNICAL SERVICES,LLC TAMKO BUILDING PRODCUTS,INC. 4 TAMKO Underlayments LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Contact the manufacturer when installing at temperatures below the minimum application temperature. 5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements. 6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 7) The underlayment may be used as described in other current FBC product approval documents. 8) The underlayment shall not be installed over existing roof coverings. 9) Contact the manufacturer regarding specific exposure limits for each underlayment. 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049), TAP-217-02-01 REV ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(fST6049) TAP-220-02-01 ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995 ASTM D 4798 2011 PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012 1 PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a UL LLC(TST9628) 13CA12269 ASTM D 226 2009 TBP14001.4 FL12328-R8 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. GREEK TAMKO BUILDING PRODCUTS,INC. TAMKO Underlayments TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. ►►►►uiIrw,i R, :• °• ,,% 2017.10.19 • No 74021 12.15.58 • �_ -04'00' :53• STATE OF •1 %CT•'••1 P.' .` • Zachary R. Priest, P.E. ••0 R 9.•" C?��`� Florida Registration No.74021 �"i,,'ONp� �`�� Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP14001.4 FL12328-R8 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODCUTS,INC. TAMKO Underlayments TECHNICAL SERVICES,LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Contact the manufacturer when installing at temperatures below the minimum application temperature. 5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements. 6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 7) The underlayment may be used as described in other current FBC product approval documents. 8) The underlayment shall not be installed over existing roof coverings. 9) Contact the manufacturer regarding specific exposure limits for each underlayment. 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995 ASTM D 4798 2011 PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012 PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a UL LLC(TST9628) 13CA12269 ASTM D 226 2009 it TBP14001.4 FL12328-R8 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. l` CREEK TAMKO BUILDING UnderlTS,INC. -- TAMKO Underlayments .-. TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT li The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. sO,%%%%IIIttIII$RY R. pill/ , �GENS• F -- 2017.10.19 tii.-• ' -;No 74021 ' 12-15-58 * _ -04'00' :153'. STATE O F :4/:: ' •• --'--T�s•.S�ONALP�.`�"� Florida Zachary R..Priest, P.E. 74021 Organization NolANE9641 i11111itIE CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 1/4 IIS END OF REPORT TBP14001.4 FL12328-R8 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.