HomeMy WebLinkAboutHealth Dept \� APPLICATION #:AP1368824 STATE OF FLORIDA PERMIT #:56-SF-1884667 DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:1 98 CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:10/15/2018 ,� FEE PAID:65.00 RECEIPT #:56-PID-3770941 APPLICANT: Gentile Corporation AGENT: MICHAEL STUHR(ASHTON SEPTIC TANKS INC.) PROPERTY ADDRESS: 205 N 40th St Fort Pierce, FL 34947 LOT: 17 BLOCK: SUBDIVISION: Wilbuwe ID#: 2408-603-0056-000-6 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED, TANK INSTALLATION SETBACKS [ ] (01] TANK SIZE [1] [2] [ ] [27] SURFACE WATER FT [ ] (02] TANK MATERIAL [ ] [28] DITCHES FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS FT [ ] [04] MULTI-CHAMBERED [ Y / N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER [ ] [31] IRRIGATION WELLS FT [ ] [06] LEGEND 1. 2. [ ] [32] POTABLE WATER FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS FT [ ] [08] LEVEL [ ] [34] PROPERTY LINES FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] [2] SQFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER [ ] [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 2. [ ] [38] SLOPES ( ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION [ ] [14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [42] ALARMS [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] [22] FILL AMOUNT [ ] [47] CONTRACTOR MICHAEL W STUHR(ASHTO [ ] [23] FILL TEXTURE [ ] [48] OTHER [ ] (24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED 10/17/2018 [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED 6 FILLED 10/17/2018 Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / St. Lucie CHO DATE: 10/17/2018 DISAPPROVED ]' Environ ntal Specialist II Pn J In (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: UCIe CHD DATE: 10/17/2018 Environmental-Specialist it Brian gram(ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Page 2 of 3 Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1368824 EID1884667 IE o3 APPLICATION #:AP1368824 STATE OF FLORIDA PERMIT #:56-SF-1884667 DEPARTMENT OF HEALTH DOCUMENT #:F11223898 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM ., CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:10/15/2018 �o w16 FEE PAID:65.00 RECEIPT #:56-PID-3770941 Violation Number Comment Comments Tank pumped and abandoned properly. No violations, system ok to cover. Contractor notified by phone. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1368824 EID1884667