HomeMy WebLinkAboutDesign Load Calculations __ , n..4 , . _ . g,,INNewsouth . Av ®® WINDOW SOLUTIONS 2526 Okeechobee Blvd,West Palm Beach,FL 33409•561-712-9000•CRC1330822 Property Information Building Information Owner: TISZAUER,DETLEV&BRIGITTE Wind Zone: 170 MPH. I. Address: 8591 HIDDEN PINE ROAD Exposure Category: C FT.PIERCE,FL 34945 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psi) 1 Int 25 61.75 7 37.6 -40.8 2 Int 72.75 61.75 7 35.0 -38.2 3 Int 72.75 61.75 7 35.0 -38.2 4 Int 24.75 61.50 7 37.7 -40.9 5 Int 24.75 61.50 7 37.7 -40.9 6 Int 52 61.75 7 35.8 -39.0 7 Int 25.25 61.75 7 37.6 -40.8 8 Int 25.25 61.75 7 37.6 -40.8 9 Int 18 44.50 7 37.8 -41.0 10 Int 44.25 44.50 7 37.0 -40.2 11 Int 44.25 44.50 7 37.0 -40.2 12 Int 44.25 44.50 7 37.0 -40.2 13 Int 18 44.50 7 37.8 -41.0 14 Int 25.25 61.75 7 37.6 -40.8 15 Int 25.25 61.75 7 37.6 40.8 li I, , p n I II 11 II II Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.' Page 1of1