HomeMy WebLinkAboutDesign Load Calculations __
, n..4 , . _ . g,,INNewsouth .
Av ®® WINDOW SOLUTIONS
2526 Okeechobee Blvd,West Palm Beach,FL 33409•561-712-9000•CRC1330822
Property Information Building Information
Owner: TISZAUER,DETLEV&BRIGITTE Wind Zone: 170 MPH. I.
Address: 8591 HIDDEN PINE ROAD Exposure Category: C
FT.PIERCE,FL 34945 Minimum Building Dimension: 25 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psi)
1 Int 25 61.75 7 37.6 -40.8
2 Int 72.75 61.75 7 35.0 -38.2
3 Int 72.75 61.75 7 35.0 -38.2
4 Int 24.75 61.50 7 37.7 -40.9
5 Int 24.75 61.50 7 37.7 -40.9
6 Int 52 61.75 7 35.8 -39.0
7 Int 25.25 61.75 7 37.6 -40.8
8 Int 25.25 61.75 7 37.6 -40.8
9 Int 18 44.50 7 37.8 -41.0
10 Int 44.25 44.50 7 37.0 -40.2
11 Int 44.25 44.50 7 37.0 -40.2
12 Int 44.25 44.50 7 37.0 -40.2
13 Int 18 44.50 7 37.8 -41.0
14 Int 25.25 61.75 7 37.6 -40.8
15 Int 25.25 61.75 7 37.6 40.8
li
I,
,
p
n
I
II
11
II
II
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.'
Page 1of1