HomeMy WebLinkAboutWind Load Calculation RECEIVED CT 2 3 20 jam. C[. Ta ,N6ie cednYr P@rrrtltting "Btldd'tng 0Ur QualtJ/ E' Utt#!Oil, Gine customer At.A Tiie" SCC131150472 Property Information Building Information Owner: SONYA CARROLL Wind Zone: 170 MPH. Address: 4790 CHRISTENSEN RD Exposure Category: C FORT PIERCE,FL 34981 Minimum Building Dimension: 31 ft. Mean Roof Height: 20 ft. jet Risk Category: II Design Pressure Calculations Opening Location Devicejr-Device Device Max Positive Max Negative Number Zone Width(in) L Height(in) Elevation(ft) IFPressure(psf) Pressure(psf) 1 Int 37 80 7 38.3 -41.7 2 Int 36 51 7 39.5 -42.9 3 Int 36 51 7 39.5 -42.9 4 Int 36 51 7 39.5 -42.9 _ 5 End 33 80 7 38.6 -50.6 6 End 51 48 7 38.8 -51.0 7 Int 51 48- Y 7 38.8 -42.2 8 Int 35 48 7 39.8 -43.2 9 Int 24 60 7 40.2 -43.6 10 Int 34 60 7 39.2 -42.6 11 Int 24 60 7 40.2 -43.6 12 Int 35 61 7 39.1 -42.5 13 End 35 49 _ 7 39.7 -52.9 14 End 36 48 7 39.7 -52.8 15 Int 36 48 7 39.7 -43.1 16 Int 37 80 7 38.3 -41.7 17 Int 36 48 7 39.7 -43.1 18 End 36 48 7 39.7 -52.8 19 End 35 48 7 39.8 -53.0 20 Int 35 60 7 39.2 -42.6 21 Int 36 48 7 39.7 -43.1 22 Int 35 60 7 39.2 -42.6 23 Int 24 35 7 40.2 -43.6 24 Int 72 22 7 39.7 -43.1 25 Int 72 22 7 39.7 -43.1 i E Ik S4 ' Page 1 of 2 n . =CEIVED Buildin O:ur Q;ual #y Reputation. OCT 23 2018 One Customer.At 'gine,; SCC131150472 ST. Lucie County, Permitting Property Information Building Information Owner: SONYA CARROLL Wind Zone: 170 MPH. Address: 4790 CHRISTENSEN RD Exposure Category: C FORT PIERCE,FL 34981 Minimum Building Dimension: 31 ft. Mean Roof Height: 20 ft. Risk Category: II Design Pressure Calculations Opening Location DeviceDevice Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psfl Pressure(pso 26 Int 32 51 7 39.8 -43.2 27 Int 24 35 7 40.2 -43.6 28 Int 32 51 7 39.8 -43.2 29 Int 60 79 7 37.0 -40.4 30 End 32 51 7 39.8 -53.1 ^31 Int 32 51 7 39.8 -43.2 32 Int 32 51 7 39.8 -43.2 33 Int 32 51 7 39.8 43.2 it) L E LAO'ft;k Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.61h Edition(2017)Florida Building Code. Page 2 of 2 OCT 23 2018 A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PRM IT` HIS EE -1�„ / ST. Lucie County, Permitting Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof ih�ght, iE alley,b not less than 4°h of least horizontal dimensio PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE OPENING (Location) IS THIS A PRODUCT ROUGH ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER + PSF PSF + PSF TESTED MULLION ( ) (-) ( ) (-)PSF SIZE DIMENSIONS REQ YIN/NA REQ Y/N 1 Int Door Solid FL15210.1 75 75 38.3 -41.7 1 37.5.81 37x80 No No 2 Int Window 718"LamiIG FL15780.8 55 65 39.5 -42.9 54x76.5 36x51 YES No 3 Int Window 7/8"L i'G FL15780.8 55 65 39.5 -42.9 54x76.5 36x51 YES No 4 Int Window 718"1amilG FL15780.8 55 65 39.5 -42.9 54x76.5 36x51 No No 5 End Door I"Lauri IG FL15210.4 75 75 38.6 -50.6 37.5 x 8I 33x80 No No 6 End Window 7/8"LamilG FL15780.8 55 65 38.8 -51.0 54x76.5 51x48 No No 7 Int Window 718"LamiIG FL15780.8 55 65 38.8 -42.2 1 54x76.5 51x48 No No 8 Int Window 7/8"LamilG FL15780.8 55 65 39.8 -43.2 54x76.5 35x48 No No 9 Int Window 78"Lan"'G FL15780.8. 55 65 40.2 -43.6 54 x 76.5 24x60 YES No 10 Int Window lis"Lam;IG FL15780.8 55 65 39.2 -42.6 54x76.5 34x60 YES No 11 Int Window 71r Lauri IG FL15780.8 55 65 40.2 -43.6 54 x 76.5 24x60 YES No 12 Int Window 7'8"Lan"'G FL15780.8 55 65 39.1 -42.5 54.76.5 35x61 No No 13 End Window 7""SIG FL15780.8 55 65 39.7 -52.9 54x76.5 35x49 No No 14 End Window 7""Lam"G FL15780.8 55 65 39.7 -52.8 1 54x76.5 36x48 YES No 15 Int Window 7""LamilG FL15780.8 55 65 39.7 -43.1 54x76.5 36x48 YES No 16 Int Door Solid FL15210.1 75 75 38.3 -41.7 37.5x8' 37x80 No No 17 Int Window 718"LamiIG FL15780.8 55 65 39.7 -43.1 54x76.5 36x48 YES No 18 End Window 718"LamilG FL15780.8 55 65 39.7 -52.8 54x76.5 36x48 YES No 19 End Window 718"LamilG 'FL15780.8 55 65 39.8 -53.0 54x76.5 35x48 No No 20 Int Window 718"LamilG FL15780.8 55 65 39.2 -42.6 54x76.5 35x60 No No 21 Int Window Tia"LamilG FL15780.8 55 65 39.7 -43.1 54x76.5 36x48 No No 22 Int Window 718"LamilG FL15780.8 1 55 65 1 39.2 1 -42.6 54x76.5 35x60 No No WINDOW & DOOkQi�F;NIING INFORMATION .. t"oOCT 23 2018 A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET U"), d j Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimensrffrr.eltticie County. Permitting OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS SIZE REQ Y/NINA NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N 23 Int Window 7""L-IG FL15780.8 55 65 40.2 -43.6 1 54x76.5 2405 No No 24 Int Window I"Lauri IG FL13010.4 55 55 39.7 -43.1 48X72 72x22 No No 25 Int Window PLamiIG FL13010.4 55 55 39.7 -43.1 4802 72x22 No No 26 Int Window 7/9"LamiIG FL15780.8 55 65 39.8 -43.2 54x76.5 32x51 No No 27 Int Window 718"L-i IG FL15780.8 55 65 40.2 -43.6 54 x 76.5 24x35 No No 28 Int Window 718"LamiIG FL15780.8 55 65 39.8 -43.2 54x76.5 32x51 No No 29 Int Door V Lauri IG FL15210.6 75 75 37.0 -40.4 74 x 81 6009 No No 30 End Window 7/8"LamiIG FL15780.8 55 65 39.8 -53.1 54x76.5 32x51 No No 31 Int Window iia"I-ui IG FL15780.8 55 65 39.8 -43.2 54 x 76.5 32x51 NO No 32 Int Window 7/8"LamiIG FL6890.1 67.5 67.5 39.8 -43.2 3702 32x51 No No 33 Int Window "$"LacmlG FL6890.1 67.5 67.5 39.8 -43.2 3702 32x51 No No