HomeMy WebLinkAboutWind Load Calculation RECEIVED
CT 2 3 20
jam.
C[.
Ta ,N6ie cednYr P@rrrtltting "Btldd'tng 0Ur QualtJ/ E' Utt#!Oil,
Gine customer At.A Tiie"
SCC131150472
Property Information Building Information
Owner: SONYA CARROLL Wind Zone: 170 MPH.
Address: 4790 CHRISTENSEN RD Exposure Category: C
FORT PIERCE,FL 34981 Minimum Building Dimension: 31 ft.
Mean Roof Height: 20 ft.
jet Risk Category: II
Design Pressure Calculations
Opening Location Devicejr-Device Device Max Positive Max Negative
Number Zone Width(in) L Height(in) Elevation(ft) IFPressure(psf) Pressure(psf)
1 Int 37 80 7 38.3 -41.7
2 Int 36 51 7 39.5 -42.9
3 Int 36 51 7 39.5 -42.9
4 Int 36 51 7 39.5 -42.9
_ 5 End 33 80 7 38.6 -50.6
6 End 51 48 7 38.8 -51.0
7 Int 51 48- Y 7 38.8 -42.2
8 Int 35 48 7 39.8 -43.2
9 Int 24 60 7 40.2 -43.6
10 Int 34 60 7 39.2 -42.6
11 Int 24 60 7 40.2 -43.6
12 Int 35 61 7 39.1 -42.5
13 End 35 49 _ 7 39.7 -52.9
14 End 36 48 7 39.7 -52.8
15 Int 36 48 7 39.7 -43.1
16 Int 37 80 7 38.3 -41.7
17 Int 36 48 7 39.7 -43.1
18 End 36 48 7 39.7 -52.8
19 End 35 48 7 39.8 -53.0
20 Int 35 60 7 39.2 -42.6
21 Int 36 48 7 39.7 -43.1
22 Int 35 60 7 39.2 -42.6
23 Int 24 35 7 40.2 -43.6
24 Int 72 22 7 39.7 -43.1
25 Int 72 22 7 39.7 -43.1
i E Ik
S4 '
Page 1 of 2
n . =CEIVED
Buildin O:ur Q;ual #y Reputation.
OCT 23 2018
One Customer.At 'gine,;
SCC131150472 ST. Lucie County, Permitting
Property Information Building Information
Owner: SONYA CARROLL Wind Zone: 170 MPH.
Address: 4790 CHRISTENSEN RD Exposure Category: C
FORT PIERCE,FL 34981 Minimum Building Dimension: 31 ft.
Mean Roof Height: 20 ft.
Risk Category: II
Design Pressure Calculations
Opening Location DeviceDevice Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psfl Pressure(pso
26 Int 32 51 7 39.8 -43.2
27 Int 24 35 7 40.2 -43.6
28 Int 32 51 7 39.8 -43.2
29 Int 60 79 7 37.0 -40.4
30 End 32 51 7 39.8 -53.1
^31 Int 32 51 7 39.8 -43.2
32 Int 32 51 7 39.8 -43.2
33 Int 32 51 7 39.8 43.2
it) L E LAO'ft;k
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.61h Edition(2017)Florida Building Code.
Page 2 of 2
OCT 23 2018
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PRM IT` HIS EE -1�„ / ST. Lucie County, Permitting
Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof ih�ght, iE alley,b not less than 4°h of least horizontal dimensio
PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE
OPENING (Location) IS THIS A PRODUCT ROUGH ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR TYPE NUMBER + PSF PSF + PSF TESTED MULLION
( ) (-) ( ) (-)PSF SIZE DIMENSIONS REQ YIN/NA REQ Y/N
1 Int Door Solid FL15210.1 75 75 38.3 -41.7 1
37.5.81 37x80 No No
2 Int Window 718"LamiIG FL15780.8 55 65 39.5 -42.9 54x76.5 36x51 YES No
3 Int Window 7/8"L i'G FL15780.8 55 65 39.5 -42.9 54x76.5 36x51 YES No
4 Int Window 718"1amilG FL15780.8 55 65 39.5 -42.9 54x76.5 36x51 No No
5 End Door I"Lauri IG FL15210.4 75 75 38.6 -50.6 37.5 x 8I 33x80 No No
6 End Window 7/8"LamilG FL15780.8 55 65 38.8 -51.0 54x76.5 51x48 No No
7 Int Window 718"LamiIG FL15780.8 55 65 38.8 -42.2 1
54x76.5 51x48 No No
8 Int Window 7/8"LamilG FL15780.8 55 65 39.8 -43.2 54x76.5 35x48 No No
9 Int Window 78"Lan"'G
FL15780.8. 55 65 40.2 -43.6 54 x 76.5 24x60 YES No
10 Int Window lis"Lam;IG FL15780.8 55 65 39.2 -42.6 54x76.5 34x60 YES No
11 Int Window 71r Lauri IG FL15780.8 55 65 40.2 -43.6 54 x 76.5 24x60 YES No
12 Int Window 7'8"Lan"'G FL15780.8 55 65 39.1 -42.5 54.76.5 35x61 No No
13 End Window 7""SIG FL15780.8 55 65 39.7 -52.9 54x76.5 35x49 No No
14 End Window 7""Lam"G FL15780.8 55 65 39.7 -52.8 1
54x76.5 36x48 YES No
15 Int Window 7""LamilG FL15780.8 55 65 39.7 -43.1 54x76.5 36x48 YES No
16 Int Door Solid FL15210.1 75 75 38.3 -41.7 37.5x8' 37x80 No No
17 Int Window 718"LamiIG FL15780.8 55 65 39.7 -43.1 54x76.5 36x48 YES No
18 End Window 718"LamilG FL15780.8 55 65 39.7 -52.8 54x76.5 36x48 YES No
19 End Window 718"LamilG 'FL15780.8 55 65 39.8 -53.0 54x76.5 35x48 No No
20 Int Window 718"LamilG FL15780.8 55 65 39.2 -42.6 54x76.5 35x60 No No
21 Int Window Tia"LamilG FL15780.8 55 65 39.7 -43.1 54x76.5 36x48 No No
22 Int Window 718"LamilG FL15780.8 1 55 65 1 39.2 1 -42.6 54x76.5 35x60 No No
WINDOW & DOOkQi�F;NIING INFORMATION
..
t"oOCT 23 2018
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET U"), d j
Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimensrffrr.eltticie County. Permitting
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS
SIZE REQ Y/NINA
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N
23 Int Window 7""L-IG FL15780.8 55 65 40.2 -43.6 1
54x76.5 2405 No No
24 Int Window I"Lauri IG FL13010.4 55 55 39.7 -43.1 48X72 72x22 No No
25 Int Window PLamiIG FL13010.4 55 55 39.7 -43.1 4802 72x22 No No
26 Int Window 7/9"LamiIG FL15780.8 55 65 39.8 -43.2 54x76.5 32x51 No No
27 Int Window 718"L-i IG FL15780.8 55 65 40.2 -43.6 54 x 76.5 24x35 No No
28 Int Window 718"LamiIG FL15780.8 55 65 39.8 -43.2 54x76.5 32x51 No No
29 Int Door V Lauri IG FL15210.6 75 75 37.0 -40.4 74 x 81 6009 No No
30 End Window 7/8"LamiIG FL15780.8 55 65 39.8 -53.1 54x76.5 32x51 No No
31 Int Window iia"I-ui IG FL15780.8 55 65 39.8 -43.2 54 x 76.5 32x51 NO No
32 Int Window 7/8"LamiIG FL6890.1 67.5 67.5 39.8 -43.2 3702 32x51 No No
33 Int Window "$"LacmlG FL6890.1 67.5 67.5 39.8 -43.2 3702 32x51 No No