Loading...
HomeMy WebLinkAboutWINDOW/DOOR INSTALLATION COMMERCIAL (2) R BCIS Home Log In User Registration Hot Topics ( Submit Surcharge I Stats&Facts Publications I FBC Staff C' BCIS Site Map' Links I Search Florida���yyy r USER:Product - �. RECEIVED Product Approval Menu>Product or Application Search>Application List>Application Detail OCT 2 Z618 • FL# FL14095-R10 FEajga Application Type Revision ST. Lucie County,pQrmnin9 Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Q Product Manufacturer JELD-WEN Address/Phone/Email 3737 Lakeport Blvd Klamath Falls,OR 97601 (800)535-3936 fbcl@jeld-wen.com Authorized Signature Jason Kantola fbcl@jeld-wen.com Technical Representative JELD-WEN Corporate Customer Service Address/Phone/Email 3737 Lakeport Blvd. >1- Klamath Falls,OR 97601 (800)535-3936 am customerserviceagents@jeld-wen.com Quality Assurance Representative Address/Phone/Email Category Windows UjSubcategory Single Hung Compliance Method Certification Mark or Listing +, Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 07/11/2017 Date Validated 07/26/2017 Date Pending FBC Approval Date Approved 07/28/2017 Summary of Products FL# Model,Number or Name Description 14095.1 Premium Atlantic Vinyl Single Hung(8100) 36"x 72"Insulated Glass(5/16 in PVB or SGP Lam-1/8 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.04-R3.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 04/30/2025 Design Pressure: +65/-70 Installation Instructions Other: Laminated glazing Interlayer material requirements FL14095 R10 II FL14095 R5 II DP65- meet the current edition of the FBC in accordance with Miami- 70 36x72 Impact Installation Instructions,1)d Dade NOA for DuPont SentryGlas and DuPont PVB interlayers. FL14095 R30 II NI011567.04-R3 Dwas 07252017.odf White PVC exterior extrusion meet the current edition of the Verified By: Hermes Norero,PE 73778 FBC in accordance with Miami-Dade NOA for Quanex.IG back Created by Independent Third Party:Yes bedded with Dow 995.Safety glazing required to the exterior Evaluation Reports at heights above 30 feet. FL14095 R10 AE PER3094.odf Created by Independent Third Party:Yes 14095.2 Premium Atlantic Vinyl Single Hung(8100) 36"x 72"Insulated Glass(1/8 in- 1/8 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14095 R10 C CAC N1011567.08-R1.[Ldf Approved for use outside HVHZ:Yes FL14095 R10 C CAC NI011567.09-R2.ndf Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure:+65/-70 04/30/2025 Other:White PVC exterior extrusion meet the current edition Installation Instructions of the FBC in accordance with Miami-Dade NOA for Quanex.IG FL14095 R10 II NI011567.09-R2 Dwas 07252017.odf back bedded with Dow 995.Safety glazing required to the FL14095 R10 II PAV TSH FBC 36x72 SS 2017-06-26.pdf exterior at heights above 30 feet. Verified By: Hermes Norero, PE 73778 Created by Independent Third Party:Yes Evaluation Reports FL14095 RSO AE PER4869 SS 2017-06-26.odf Created by Independent Third Party:Yes 14095.3 Premium Atlantic Vinyl Single Hung (8100) 52 1/8"x 75"Insulated Glass(3/16 in- 3/16 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.06-111.odf Approved for use outside HVHZ:Yes FL14095 RSO C CAC NI011567.07-R2.odf Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure: +65/-70 04/30/2025 Other:White PVC exterior extrusion meet the current edition Installation Instructions of the FBC in accordance with Miami-Dade NOA for Quanex.IG FL14095 R10 II N1011567.07-112 Dwas 07252017.ndf back bedded with Dow 995.Windows with insulated glass FL14095 R10 II PAV TSH FBC 52x75 SS 2017-06-26.0 wider than 36"require setting blocks.Safety glazing required Verified By: Hermes Norero, PE 73778 to the exterior at heights above 30 feet. Created by Independent Third Party:Yes Evaluation Reports FL14095 RSO AE PER4870 SS 2017-06-26.pdf Created by Independent Third Party:Yes 14095.4 Premium Atlantic Vinyl Single Hung(8100) 52 1/8"x 75"Insulated Glass(5/16 in PVB or SGP Lam- 1/8 out Annealed) imits o se Certification Agency Certificate Approved for use in HVHZ:Yes FL14095 RSO C CAC N1011567.02-R2.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 04/30/2025 Design Pressure: +50/-60 Installation Instructions Other:Laminated glazing interlayer material requirements FL14095 R10 II FL14095 R5 II DP50- meet the current edition of the FBC in accordance with Miami- 60 52.125x75 Impact Installation Instructions.Of Dade NOA for DuPont SentryGlas and DuPont PVB interlayers. FL14095 R10 II NI011567.02-R2 DwQs 07252017.pdf White PVC exterior extrusion meet the current edition of the Verified By: Hermes Norero,PE 73778 FBC in accordance with Miami-Dade NOA for Quanex.IG back Created by Independent Third Party:Yes bedded with Dow 995.Windows with insulated glass wider Evaluation Reports than 36"require setting blocks.Safety glazing required to the FL14095 R10 AE PER3091.odf exterior at heights above 30 feet. Created by Independent Third Party:Yes 14095.5 Premium Atlantic Vinyl Single Hung(8100)52 1/8"x 75"Insulated Glass(5/16 in SGP Lam-3/16 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.01-Rl.pdf e= Approved for use outside HVHZ:Yes FL14095 R10 C CAC NI011567-RI.odf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +65/-75 04/30/2025 Other:Laminated glazing interlayer material requirements Installation Instructions meet the current edition of the FBC in accordance with Miami- FL14095 R10 II FL14095 R5 II DP65- Dade NOA for DuPont SentryGlas and DuPont PVB interlayers. 75 52.125x75 Impact Installation Instructions.Ddf White PVC exterior extrusion meet the current edition of the FL14095 R10 II NI011567 01 Ri Dwos 07252017 odf FBC in accordance with Miami-Dade NOA for Quanex.IG back Verified By: Hermes Norero, PE 73778 bedded with Dow 995.Windows with insulated glass wider Created by Independent Third Party:Yes than 36"require setting blocks.Safety glazing required to the Evaluation Reports exterior at heights above 30 feet. FL14095 R10 AE PER3095.odf Created by Independent Third Party:Yes Hack Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: �.® ZZ -�..c®-. Credit Card Safe i G 14'Dom. , + =STANCE THROUGH FRAME ""°'"B rt f'rt- MDaD FOR EDGE:3/4.3 i INSTALLATION 2 TMIN. EMBEDMENT t D.C. t 11/2' EMBEDMENT uue MAXEMBEDMENT 1/A, AX 5HIMSPACE I SHIM SP1/4"MSP 3 SHIM 22 2mm 3mm 3— ' MIN.DISTANCE2 FOR EDGE:3/4• GlA55 BITE 13,mm 1 r 1 G7!�F AIL JAMB SECTION(TYP) HORIZONTAL SECTION i TION(TYP)SECTION !� V4•MA% I I E.M SPACE 3 t 2 EMBEDMENT PREMIUM ATLANTIC VINYL SH WINDOW Max Frame I DP RATING IMPACT WDO W"DTH(52,/e wxj MIN DISTANCE 52 1/8 x 75 1 +50/-60 1 YES TYPICAL ELEVATION WITH FASTENER 5PACING FOR EDGE:3/4` LARGE MISSILE IMPACT Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The'product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use#10 PH or greater fastener though the jamb with sufficient length to penetrate a minimum of 11/2" of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida into the wood framing. For 2X wood frame substrate(min,S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure.The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing is 3mm annealed-11mm airspace-3mm annealed-2mm PVB Interlayer by project of installation. Addendum to NANI DuPont-3mm annealed. Certification No: NI011567.02-R2 4. Use structural or composite shims where required. Reviewed By: x420 This schedule addresses only the fasteners required to anchor the Date Reviewed: 07/25/2017 window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does PROJECT ENGINEER: DATE: 3737 Lakeport Blvd not address he sealing consideration that may arise in different wall 08/13/2014 TELDr�NEN conditions. For the complete installation procedure,see the instructions DRAWN BY: SCALE: J Klamath Falls,OR.97601 packaged with the window or go to D.Vezo NTS Phone: (800)535-3936 CHECKED BY: TITLE: www.jeld-wen.com/resourcesrinstallafion. J.Kantola DISCLAIMER: APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window This drawing and its contents are confidential and are not to be P�RT�P�ozE�r g reproduced or copied in whole or in part or used or disclosed to others UU ttS3// except as authorized by JELD-WEN Inc. NCT1210 3874 PFBNTT NAME AND LOCATION: CAD DWG.No.: REV: 00 SHEET I of I .Ay SID.