HomeMy WebLinkAboutWINDOW/DOOR INSTALLATION COMMERCIAL (2) R
BCIS Home Log In User Registration Hot Topics ( Submit Surcharge I Stats&Facts Publications I FBC Staff C' BCIS Site Map' Links I Search
Florida���yyy
r
USER:Product -
�. RECEIVED
Product Approval Menu>Product or Application Search>Application List>Application Detail OCT 2 Z618
• FL# FL14095-R10
FEajga Application Type Revision ST. Lucie County,pQrmnin9
Code Version 2017
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived Q
Product Manufacturer JELD-WEN
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls,OR 97601
(800)535-3936
fbcl@jeld-wen.com
Authorized Signature Jason Kantola
fbcl@jeld-wen.com
Technical Representative JELD-WEN Corporate Customer Service
Address/Phone/Email 3737 Lakeport Blvd.
>1- Klamath Falls,OR 97601
(800)535-3936
am customerserviceagents@jeld-wen.com
Quality Assurance Representative
Address/Phone/Email
Category Windows
UjSubcategory Single Hung
Compliance Method Certification Mark or Listing
+, Certification Agency National Accreditation&Management Institute
Validated By National Accreditation&Management Institute
Referenced Standard and Year(of Standard) Standard Year
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 07/11/2017
Date Validated 07/26/2017
Date Pending FBC Approval
Date Approved 07/28/2017
Summary of Products
FL# Model,Number or Name Description
14095.1 Premium Atlantic Vinyl Single Hung(8100) 36"x 72"Insulated Glass(5/16 in PVB or
SGP Lam-1/8 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.04-R3.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 04/30/2025
Design Pressure: +65/-70 Installation Instructions
Other: Laminated glazing Interlayer material requirements FL14095 R10 II FL14095 R5 II DP65-
meet the current edition of the FBC in accordance with Miami- 70 36x72 Impact Installation Instructions,1)d
Dade NOA for DuPont SentryGlas and DuPont PVB interlayers. FL14095 R30 II NI011567.04-R3 Dwas 07252017.odf
White PVC exterior extrusion meet the current edition of the Verified By: Hermes Norero,PE 73778
FBC in accordance with Miami-Dade NOA for Quanex.IG back Created by Independent Third Party:Yes
bedded with Dow 995.Safety glazing required to the exterior Evaluation Reports
at heights above 30 feet. FL14095 R10 AE PER3094.odf
Created by Independent Third Party:Yes
14095.2 Premium Atlantic Vinyl Single Hung(8100) 36"x 72"Insulated Glass(1/8 in- 1/8 out
Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R10 C CAC N1011567.08-R1.[Ldf
Approved for use outside HVHZ:Yes FL14095 R10 C CAC NI011567.09-R2.ndf
Impact Resistant:No Quality Assurance Contract Expiration Date
Design Pressure:+65/-70 04/30/2025
Other:White PVC exterior extrusion meet the current edition Installation Instructions
of the FBC in accordance with Miami-Dade NOA for Quanex.IG FL14095 R10 II NI011567.09-R2 Dwas 07252017.odf
back bedded with Dow 995.Safety glazing required to the FL14095 R10 II PAV TSH FBC 36x72 SS 2017-06-26.pdf
exterior at heights above 30 feet. Verified By: Hermes Norero, PE 73778
Created by Independent Third Party:Yes
Evaluation Reports
FL14095 RSO AE PER4869 SS 2017-06-26.odf
Created by Independent Third Party:Yes
14095.3 Premium Atlantic Vinyl Single Hung (8100) 52 1/8"x 75"Insulated Glass(3/16 in-
3/16 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.06-111.odf
Approved for use outside HVHZ:Yes FL14095 RSO C CAC NI011567.07-R2.odf
Impact Resistant:No Quality Assurance Contract Expiration Date
Design Pressure: +65/-70 04/30/2025
Other:White PVC exterior extrusion meet the current edition Installation Instructions
of the FBC in accordance with Miami-Dade NOA for Quanex.IG FL14095 R10 II N1011567.07-112 Dwas 07252017.ndf
back bedded with Dow 995.Windows with insulated glass FL14095 R10 II PAV TSH FBC 52x75 SS 2017-06-26.0
wider than 36"require setting blocks.Safety glazing required Verified By: Hermes Norero, PE 73778
to the exterior at heights above 30 feet. Created by Independent Third Party:Yes
Evaluation Reports
FL14095 RSO AE PER4870 SS 2017-06-26.pdf
Created by Independent Third Party:Yes
14095.4 Premium Atlantic Vinyl Single Hung(8100) 52 1/8"x 75"Insulated Glass(5/16 in PVB
or SGP Lam- 1/8 out Annealed)
imits o se Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 RSO C CAC N1011567.02-R2.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 04/30/2025
Design Pressure: +50/-60 Installation Instructions
Other:Laminated glazing interlayer material requirements FL14095 R10 II FL14095 R5 II DP50-
meet the current edition of the FBC in accordance with Miami- 60 52.125x75 Impact Installation Instructions.Of
Dade NOA for DuPont SentryGlas and DuPont PVB interlayers. FL14095 R10 II NI011567.02-R2 DwQs 07252017.pdf
White PVC exterior extrusion meet the current edition of the Verified By: Hermes Norero,PE 73778
FBC in accordance with Miami-Dade NOA for Quanex.IG back Created by Independent Third Party:Yes
bedded with Dow 995.Windows with insulated glass wider Evaluation Reports
than 36"require setting blocks.Safety glazing required to the FL14095 R10 AE PER3091.odf
exterior at heights above 30 feet. Created by Independent Third Party:Yes
14095.5 Premium Atlantic Vinyl Single Hung(8100)52 1/8"x 75"Insulated Glass(5/16 in
SGP Lam-3/16 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.01-Rl.pdf
e=
Approved for use outside HVHZ:Yes FL14095 R10 C CAC NI011567-RI.odf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +65/-75 04/30/2025
Other:Laminated glazing interlayer material requirements Installation Instructions
meet the current edition of the FBC in accordance with Miami- FL14095 R10 II FL14095 R5 II DP65-
Dade NOA for DuPont SentryGlas and DuPont PVB interlayers. 75 52.125x75 Impact Installation Instructions.Ddf
White PVC exterior extrusion meet the current edition of the FL14095 R10 II NI011567 01 Ri Dwos 07252017 odf
FBC in accordance with Miami-Dade NOA for Quanex.IG back Verified By: Hermes Norero, PE 73778
bedded with Dow 995.Windows with insulated glass wider Created by Independent Third Party:Yes
than 36"require setting blocks.Safety glazing required to the Evaluation Reports
exterior at heights above 30 feet. FL14095 R10 AE PER3095.odf
Created by Independent Third Party:Yes
Hack Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please click here.
Product Approval Accepts:
�.® ZZ -�..c®-.
Credit Card
Safe i
G
14'Dom. , + =STANCE
THROUGH FRAME
""°'"B rt f'rt- MDaD FOR EDGE:3/4.3 i INSTALLATION
2
TMIN.
EMBEDMENT
t D.C.
t
11/2'
EMBEDMENT
uue MAXEMBEDMENT
1/A,
AX
5HIMSPACE I SHIM SP1/4"MSP
3 SHIM
22
2mm
3mm
3— '
MIN.DISTANCE2
FOR EDGE:3/4•
GlA55 BITE
13,mm
1 r 1
G7!�F
AIL JAMB SECTION(TYP)
HORIZONTAL SECTION
i TION(TYP)SECTION
!� V4•MA% I I
E.M SPACE
3
t 2 EMBEDMENT PREMIUM ATLANTIC VINYL SH WINDOW
Max Frame I DP RATING IMPACT
WDO W"DTH(52,/e wxj MIN DISTANCE 52 1/8 x 75 1 +50/-60 1 YES
TYPICAL ELEVATION WITH FASTENER 5PACING FOR EDGE:3/4` LARGE MISSILE IMPACT
Installation Notes: General Notes:
1. Seal flange/frame to substrate. 1. The'product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. Use#10 PH or greater fastener though the jamb with sufficient length to penetrate a minimum of 11/2" of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
into the wood framing. For 2X wood frame substrate(min,S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions.
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300.
to the structure.The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing is 3mm annealed-11mm airspace-3mm annealed-2mm PVB Interlayer by
project of installation. Addendum to NANI DuPont-3mm annealed.
Certification No: NI011567.02-R2 4. Use structural or composite shims where required.
Reviewed By: x420
This schedule addresses only the fasteners required to anchor the Date Reviewed: 07/25/2017
window to achieve the rated design pressure up to the size limitations
noted. It is not intended as a guide to the installation process and does PROJECT ENGINEER: DATE: 3737 Lakeport Blvd
not address he sealing consideration that may arise in different wall 08/13/2014 TELDr�NEN
conditions. For the complete installation procedure,see the instructions DRAWN BY: SCALE: J Klamath Falls,OR.97601
packaged with the window or go to D.Vezo NTS Phone: (800)535-3936
CHECKED BY: TITLE:
www.jeld-wen.com/resourcesrinstallafion. J.Kantola
DISCLAIMER: APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window
This drawing and its contents are confidential and are not to be P�RT�P�ozE�r g
reproduced or copied in whole or in part or used or disclosed to others UU ttS3//
except as authorized by JELD-WEN Inc. NCT1210 3874 PFBNTT NAME AND LOCATION: CAD DWG.No.: REV: 00 SHEET I of I
.Ay SID.