HomeMy WebLinkAboutProduct Approval RECEIVED
OCT B 5 2018 EXTERIOR RESEARCH&DESIGN, LLC. .
Certificate of Authorization#9503
TRINITY I sT. Lucie County, ParmInIng 353 CHRISTIAN STREET, UNIT#13
QOERD OXFORD,CT 06478
(203) 262-9245
EVALUATION REPORT �� '� 0
Owens Corning d Ltvaluation Report 037940.02.12-118
One Owens Corning Parkway FL10674-1113
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens.Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen P.E. �'�:�s^"~'• ' C The facsimile seal appearingwas authorized b Robert
Florida Registration No.59166,Florida DCA ANE1983
t' - +.....����y" • Nieminen,P.E.on 10/09/2017.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E. does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
A
TRINITY 1 ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning; have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Entity Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic'and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire'"" are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration', TruDefinition' Duration', Duration' Premium Cool, Tru Definition' Duration' Designer Color
Collection, TruDefinition'Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire' Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidge'" Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any Way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization x9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
'4
4` JTRINITYJ ERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable
for use in all wind zones Up to Vasd = 150 mph (Volt = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones Up to Vasd=150 mph (V,it=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 611320-3.
6. INSTALLATION:
6_1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6_2 Asphalt Shingi s:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
> Berkshire'shingles require minimum five(5) nails per shingle.
> WeatherGuard'HP shingles require minimum six(6)nails per shingle.
DevonshireT""shingles require minimum six(6)nails per shingle.
Starter Strip Shingle and Starter Strip Plus require minimum five(5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Felt undedayment Deck Feltundedeymeniti� Deck Se#4dhered
r
Self-adhered
Weathell.ockLo
undedaymmt
WeatherLock'
underlayment
Drip_ Dripedge
e � Drip edge Drip— -
g edge
Nails located Naas located
2'-3'from eave
2-3"from eave
Install first Self-sealing adhesive Selhaaarng adhesive
Starter Strip positioned along eave Msta�rust starter Strip PWs positioned along eave
shingle with with C removed .- •-
6"removed
Starter Strip shingle overhangs eaves and rakes tip"-3i Sorter Strip Pkrs ove hangs eaves and rakes 1!4'4/4"
Exterior Research and Design,LLC. 4 Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6'H EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 8
t
\,, TRINITY I ERD
6.2.6 Minimum Nailing—Classic®&Supreme:
Normal Mansard or Area para Normal Mansard or Area par;
VWind Areas High Wind desvanes y Wind Aram High Wind desvanes y
Area pan vientos normales Areas viantos fuortea Area pan vientos normeies Areas vientos fuertes
(A) r r z• (B r2' (B) 2' V
22
I
5•Frrpowro 5 5/B'Exposure
Exposicitin
Exposiei6a
6.2.7 Minimum Nailing—Berkshire®:
Sealant ship Sealant strip
La tka de sal idff La tira de sellador
8 Sha 9 Vf 9 Vf 8 Yf } e Sh• a 12"
l- S•J S S"J
r
r
r
Standard Fastening Pattern 6-Nail Fastening Pattern
Sealard sirry
La tka de sallador
�F—fie 4---*• 04---------+•t--->•
r 8SY 8Vf 8tff 8St
t'
r
a _
2• Asphalt roofing tmmt
Cemeato de terko de astado
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-118
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 4 of 8
``, TRINITY I ERD
6.2.8 Minimum Nailing—Devonshire'"":
1" I 7" I 8" I 8" 8- 7- 47
_1^
aegei
.._...
Nails
r t
5-518'exposure Sealant location
Exposici6n de 5 5I8 pu(g Ubicacidn del sellador s,•
Ten 1"Spots of Asphalt ADof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration", TruDefinition® Duration, Duration° Premium Cool & TruDefinition"
Duration Designer Color Collection:
4-Nall Fastening Pattern 6-Nall Fastening Pattern
SIaNlail$fastening ant width $_Nad®tastening gni Widal
DWI'Typical ////----Nail,Typi=
+^ tr tr r r tr tr t^
�-..c-:m..aa .. ,:.. -w. -�.s.o,.r.,.:.-•.-a.o.. ww..,.... r•....�ww�t_"._�—,- e,w�..,+o_. ;.�.,r�.ow«r -.
rate•�•T
N1,- .�cF't�f•• �F� st/e^scars^ F. : w +,t_,. �
.1.•
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
SunNY14 faabNng enw width
N.a.YM.er
1 t2^ tr
s�.•r..-.o w.. .. �.+n.-oea..: ..•o�..c...w ..a'
1.. ,..vs.,, r, S+T
.. .
four 1'spun olA�plW R,,0ng Gnwet
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6T'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
TRINITY ERD
6.2.1 Minimum Nailing—Tru Definition'Oakridge",Oakridge":
4 Nail Pattern 6 Nall Pattern
aquema con 4 clavas Esvema con 6 davos
Ir
55/a"Exposure 5 5ff Exposure
Nah Nails
ETosiof&de 65/6 pzdq. cfavas EgasicOn do 5 5ICpLdg. 55f Exposure cbvog 5 BAr Exposure
Eq,osid6n de 5 518puig Exposici6n de 5 618 pLdg.
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
NSA Typk.1
12, i 1r
Z.
Feu r
&Iff
0 0
X,
Spot 0A.Phft Pt—Mg C—W
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
IVI single side View
2 VANS AlIftroy
Qw�as jail
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FI-10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
TRINITY ERD
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, WeatherGuard£ HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgel Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 04 Fig.2
(
Dkedion \ P Top View SideKew
Nags-- \� Nails Nails
\ 4
\ 1 r Top La anal, r 1
A I I 4' Race
�
t-
qQ I 1
1� I I I I I
\\\A I j I l I
\ \ P
�
I
� ul
\\ \
6.3.4 Minimum Nailing—WeatherGuard°HP Hip and Ridge:
Fig.A9 1?
Fig.C Hip&Ridge Shingle Fastening
PMjailiE- rodbn W� Top Vlnv
Dl
Nails 44 \�
Nails Nails
4 4 �\• I I 7• I l"
��^\\ \ i i 1 I �• I I �•
� \ n\ I I I I ►-�+
EzposuR
EYpOAIR
\� 12
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
f
i
TRINITY!ERD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Fastening
tt.
Wind Direction fastening
Sealant Strip Pattern
6'Exposure
t2• f� Sealant
Fasten 71h' 7'h' 6*Expoaury
Cover Exposed
Fasteners w
Roof Cement `+--12• I
6.3.6 Minimum Nailing—DuraRldgeT"Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
FV.g Wind Din", We-�
DIraaiondmamntaduva�sr (I- Wasuperion I'}
Dim dbn da tiCntz,prqaornlnOnta J !!
NO
Cbu
—�--y ��{- 'i,;d'WCiI{t.4(II�nH 51iIC�'� •- •.• Clvw
Ndjk
+ t ! Iy
} 4 +1 uls$
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FSC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;{631}546-2458;Kanchi.Agrawala-Dokania@ul.com
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8