Loading...
HomeMy WebLinkAboutProduct Approval 398 East Dania Beach Blvd. BUILDING DROPS Suite 338 Dania Beach, FL 33004 A Perfect Solution in Every Drop! 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report RECEIVED Of OCT 29 2018 Silver Line Windows & Doors ST. Lucie County, Permltting. V1 Series/70 Series Single Hung Window (2907/4907) Extruded Vinyl Window w/Flange for Florida Product APP ro r -1i L FL##. FL14911 Report No. 5884 Current Florida Building Code Method: 1— D (Engineering Evaluation) Category: Windows Sub—Category: Single Hung Product: V1 Series/70 Series Single Hung Window (2907/4907) Material: Vinyl Product Dimensions: Refer SWD053 for Dimensions Prepared For: Silver Line Building Products Corp. One Silverline Drive North Brunswick, NJ 08902 Prepared by: o````ff !ra,,tcOr��'�i Hermes F. Norero, P.E. �• •' Florida Professional Engineer#73778 e E Date:08/15/2018 *' N . 7 7 Contents: S. A OF r Evaluation Report Pages 1-3 p g pT O Digitally signed by Hermes F.Norero,P.E. IL Reason: Reason:I am approving this document /�� L Date:2018.08.1717:33:15-04'00' Hermes' t 1000$, P.E. Florida No.73778 BUILDING DROPS FL#: FL14911 A Perfect Solution in Eve Drop! Date: 08/15 /2018 Every P• Report No: 5884884 Certificate of Authorization:29578 Manufacturer: Silver Line Building Products Product Category: Windows Product Sub-Category: Single/Triple Hung Compliance Method: State Product Approval Method(1)(d) Product Name: V1 Series/70 Series Single Hung Window(2907/4907) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for Silver Line Building Products based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation-Florida Building Commission. Hermes F. Norero, P.E.does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions SWD020,signed and sealed by Hermes F. Norero, P.E. (FL#73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in with the current Florida Building Code, excluding the"High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does require an impact resistant covering. 5. Site conditions that deviate from the details of drawing SWD053 require further engineering analysis by a licensed engineer or registered architect. 6. See Installation Instructions SWD053 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No.73778 Page 2 of 3 BUILDING DROPS FL#: FL14911 A Perfect Solution in Eve Drop! Date: 08/15 /2018 Every P• •Report No: 5884884 Certificate of Authorization:29578 Quality Assurance Entity: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a Quality Assurance Entity through Window and Door Manufacturers Association(FBC Organization#QUA2515). Performance Standards: The product described herein has been tested per: • AAMA/WDMA/CSA 101/I.S.2/A440-11 Referenced Data: 1. Product Testing performed by Architectural Testing,Inc. (FBC Organization#TST1795) Report#:ATI E5613.01-109-47 Report Date:03/03/2015 Report#:ATI G1000.01-109-47 Report Date:08/08/2016 Report#:ATI C7073.01-109-47 Report Date:06/17/2013 Report#:ATI G8077.01-109-47 Report Date:03/29/2017 .Report#:ATI D2935.01-109-47 Report Date: 12/30/2013 Report M ATI G0996.01-109-47 Report Date:08/02/2016 Report M ATI C4709.01-109-47 Report Date:01/11/2013 Report M ATI D5514.01-109-47 Report Date: 03/18/2014 2. Quality Assurance Entity Window and Door Manufacturers Association (FBC Organization#QUA2515) Installation Method: Please refer to installation instructions,SWD053,for anchor methods,selection,spacing, edge distances,embedmenVs and further details of installation. Design Pressure: Please refer to installation instructions,SWD053,for mull combination grouping, configurations,and corresponding design pressures. Hermes F. Norero, P.E. Florida No.73778 Page 3 of 3 Silver Line SILVER LINE BUILDING PRODUCTS CORP. by �" ` jj 3 V1 SERIES/70 SERIES SINGLE HUNG WINDOW (2127) ON BRUNS LINE DJ 0E NONTN BRUNSWICK,W 08902 (IMPACT RATED)(HVHZ) u 91 PH:aW z 77a zN s 0tL mw o ?.16 IN$ Ir'"i�p FZ (D M2 oz g� zgs6 GENERAL NOTES: Z z j 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MAX OVERALL SIZE TABLE OF CONTENTS DESIGN MISSILE �+ / MANUFACTURED TO COMPLY WITH THE CURRENT EDITION CONFIG. � w ! FLORIDA BUILDING CODE(FBC),INCLUDING HVHZ AND HAS WIDTH HEIGHT PRESSURE IMPACT RATING SHEET REVISION SHEET DESCRIPTION n `a BEEN EVALUATED ACCORDING TO THE FOLLOWING: • TAS 201-94 52" 73" CIA +55/-60 PSF UMI/SMI 1 GENERAL NOTES&GLAZING DETAIL a • TAS 202-94 2 - ELEVATION&ANCHOR LAYOUTS • TAS 203-94 REMARKS BY DATE • ASTM E330-02 3 - VERTICAL SECTIONS • ASTM E1886-05 • ASTM E1996-06/09/12 4 - HORIZONTAL SECTIONS • AAMA/WDMA/CSA 101/I.S.2/A440-08 5 - HORIZONTAL&VERTICAL SECTIONS,INSTALLATION NOES& REINFORCEMENT DETAILS 2. ADEQUACY OFTHE EXISTING STRUCTURAL CONCRETE/MASONRY,2X FRAMING,AND METAL FRAMING " MD-GE HE PR W UM IN MM OR PMT ASA MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WDHOMWR NWMENTOF BURDINGN KNC WITHSTANDING AND TRANSFERRING APPLIED PRODUCTuTaunDN%M=DN%IUGxDaxnNe;DaDTHER LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE NMDNGsron'N Wanaxrx1-MOUR �mEN. Rmrtrtou+D ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. Iailaclln sig OIti &ijf'Ipre ant 43/64"O.A.I.G.(AMINATED GLASS 1 A� CONSISTING OF: ate: 0{j E 3. 1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND �� •' ��1/8"ANNEALED GLASS �� E•• e ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE � STRUCTURE.BUCK DESIGN AND INSTALLATION IS THE 7/32"STEEL SPACER ' `S•• �O ` RESPONSIBILITY OF THE ENGINEER ORARCHITECTOF �{I 3/32 ANNEALED GLASS N 7 RECORD FOR THE PROJECT OF INSTALLATION. I 0.090"SAFLEX PVB INTERLAYER BY EASTMAN CHEMICAL COMPANY -0 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE 3/32"ANNEALED GLASS GENERICANDASPECIFICSIEOE TE.AT )oP F SITE CONDITIONS CAU INSTALLATION /� i�'jQ�� 5 A LICENSETO D EDETAILED FROM THE REQUIREMENTS ENGINEER EROR ARCHITECT SHALL ALL PREPARE SITE EXTERIOR SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN / INTERIOR 7N�F1.pp o 73 78 NON-HVHZ AREAS.IN HVHZ AREAS,ONE TIME PRODUCT ' MO D N•.NO auumNo oaoes NO APPROVAL TO BE OBTAINED FROM MIAMI-DADS RER OR I I 398 a uNIA o =MaW 3v ,n AHI. Pa6E mOF euaET.a wrNoa¢AnaN No sone STEEL SPACER p S. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED MIN.GLASS FL#: F L 14911 ON THIS PRODUCT IN AREAS REQUIRING IMPACT 1/8"OR 3/32" BITE 7/16" RESISTANCE. SETTING BLOCK �g 6. WINDOW FRAME MATERIAL:PVC DOW 995 SEALANT DATE: 01.23,18 S DWG.BY: CHK.BY: 7. IN ACCORDANCE WITH THE CURRENT EDITION FBC,WOOD GLAZINGDETAILI HR HFN COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN SCALE: NTS g CHAPTER 23. NOTE: ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH DWG.#: SWD050 B. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 SAFETY GLAZING REQUIREMENTS OUTLINED IN SHEET: GLASS CHARTS.SEE SHEET 1 FOR GLAZING DETAILS. CURRENT FBC AND ASTM E 1300 GLASS LOAD RESISTANCE. OF 5 Silver Line B tyAnderseri s� C ONESIWERLINEDRP/E NORTH BRUNSWICK.NJ 08902 PH:BW 236-0228 U m MAX.O.A FRAME z p E WIDTH 52" 'z-^n C Q r e MAX.D.L.O. w WIDTH 47.69" p ? �g� a 3"MAX. 6"MAX. 6.25"MAX. o z 'D O.C. FROM 0 z z FROM s s a I` I 3 "E •• A B 3 3 CORNERSCORNERS p l a- �� z zz o �a w> F Y m m L NOTE: ALL FASTENERS ABOVE THE MEETING RAIL IN J i a THE INTERIOR JAMB F- 6"MAX. ^0^ TRACK�MUST BE FLAT HEAD ^p^ ~ a MAX.D.L.O. "O" O.C. REMARKS BY I DATE HEIGHT33.50" C 4 12.50"MAX. MAX.O.A FRAME O.C. HEIGHT 73" TX ENT IST EPROPERTYOF I'll-N ORO W D WRNO�WNTTEN WN.ONT000F BInIINNG DROPS,WC 4 AlTFM1WNS,RO01110NS,XIGMIGHIING O0.0DRA MAX.D.L.O. ^% %�� MNWNGSTOTXISOMUMEMARE NOTPERMITTED AND HEIGHT33.50" % 6.25"MAX. NNAwATE RaRNPIunaN. 3"MAX. FROM FROM ,iiiiilltlll/�/ CORNERS CORNERS i 1 1 � o S A OF ELEVATION ANCHOR LAYOUT ANCHOR LAYOUT 0� w`"� L SINGLE HUNG WINDOW NAIL FIN-SINGLE HUNG WINDOW THROUGH FRAME-SINGLE HUNG WINDOW FLORIDAPS N6 73778 S BUIIOW0 No INC 398 L DANA DANA BEAM,BFAG51 Rw. 33 a5 E F81PE MRT.M ANHOEBZAnCN Na 285M FL#: FL14911 DATE: 01.23.18 DWG.BY: CHK.BY: HR I HFN SCALE: NTS DWG.#: SWD050 SHEET: 2 OF 5 Silver Line byAncWIWh EB" _ ONE SILVERUNE DRIVE pp O NORTH BRUNSWICK,N108902 PH:800 234-0218 LD Z N R Vi I. Z & G o SEE GLAZING SEE GLAZING 0° � �=x oz (DU DETAIL,SHEET 1 DETAIL,SHEET I 3 S poo R m w Z a O Q n mm O 7 w f W K � a REMARKS BYDATE z ~ x W W 2 x EXTERIOR INTERIOR a1� EXTERIOR INTERIOR LL ANDSHRLLNOf BF REflt00V[SDIN WNDIFN VNR V WIDNIIR WRIRFN WIMWOFBUROING DROP.INC a ALIEPAIpN.RDORIDNS,HIGHUGNNNG,ORI—M .MARNNGS NNAUDfRh ou����PEWWREOAND d Cs ``r��11i 161Iafl/� I J �* N .77 d o � SEE GLAZING SEE GLAZING '0 S A. -OF 7r DETAIL,SHEET 1 DETAIL,SHEET 1 0 O' SOP •l(f�,` He6K6aoiooroa'dX I/ 6/ =DDAA PPB No 73778 M E.OANIBEA ePWKKx BLIO./S]! DANIA AOA R JJOOf FBPE CERT.OF wiHaR>UnaN No.2857e E o u FL«. FL14911 DATE: 01.23.18 DWG. cH HFN SCALE: NTS A VERTICAL SECTION g VERTICAL SECTION DWG.#: SWD050 3 NAIL FIN 3 THRU FRAME SHEET: OF 5 Silver Line byAndOrkh ONE SILVERUNEDRIVE NORTH BRUIMI[M NJ 08902 PH:800 1344228 tjZ INTERIOR SECTION FOR z I, e SECTION FOR Z SEE GLAZING CONSTANT FORCE BLOCK&TACKLE SEE GLAZING w BALANCERS/o\ DETAILSHEET1 DETAIL SHEET 1 /oma BALANCERS 3 E s 21 I 1 w0 ommq, OO OO ®j 0 o z_ z z s r H ED= C°TL, EXTERIOR l �i Q W r• D.L.O. REMARKS BY DATE MAX.FRAME WIDTH HORIZONTAL SECTION 4 UPPERSASH N RNDAWLNOf BEPFi0.000D:D IN WNDIE DRPNR WRHDUfWRIJMDM0r,%HI BURIaNDDRDES,INC ILLTFMTIDNS,RD DDI I.E H WIRIGHDNG,OR OTHDI SEE GLAZING mnnnNssroTwsoavMENrnRF—Pl nm�EDaxD SEE GLAZING wvartauR CETAILSHEETI INTERIOR DETAIL L�3lfittttfI1,' . 7 �O'' \_ S A OF :ir EXTERIOR 1► D.L.O. a:EN.iavTe�' c BIAIDMO DROPS,INC ave E.DIVMDANIA efA01 9.VD./sTe E MAX.FRAME WIDTH - RIPE OIRT.OF AUI10187A110N N.78378 FLN: p HORIZONTAL SECTION FL14911 4 LOWER SASH DATE: 01.23.18 DWG.BY: c"K.BY: SCALE: NTS DWG.a: SWD050 SHEET: OF 5 1/4"MAX. . MIN. SUBSTRATE MINEMBEDMENT SSUBSTRATE SUBSTRATE Silver Line HIM SPACE EDGE DISTANCE BY OTHERS 3 BY OTHERS BY OTHERS MARde"i's M INTERIOR SCREW IN THE INTERIOR r CHANNEL MIN. MIN. EDGE DISTANCE IR+w ONE SILVERLINE ORNE EMBEDMENT p U NORTH 8RUNSwIC8,W 09902 SCREW IN THE EXTERIOR w< PH:800 236-4228 CHANNEL � z,�_ PERIMETER SEALANT 1/4"MAX w z U BY OTHERS o SHIM SPACE PERIMETEBLA Y OTHER SEA INT RS Z�` B EXTERIOR MIN. SHIM SPACE v1 N N a a e EXTERIOR INTERIOR EXTERIOR P771 INTERIOR '�+'V J o z $_ EMBEDMENT z 3 Lg z l- p-5 3 M NQ PZz 0m�aaa HORIZONTAL SECTION o Z ;o W 0.3 A VERTICAL SECTION g HORIZONTAL SECTION C N 3: 13:5 U o W o 6 THROUGH FRAME(HEAD) 6 THROUGH FRAME(JAMB) 6 NAIL FIN(HEAD) ++ a a o 3 N= OZZ ''DO n 2 N—� m 1/4"MAX. REINFORCEMENT DETAILS ' o W a SUBSTRATM SPACE BY OTHERS 10.34" H a INTERIOR Z 0.87" — 0.13" REMARKS BY DATE 0.77" � INTERIOR " T I �0.46„ o e EXTERIOR } 0.06" 0.87" 0.45" z 1 O LOCK RAIL TOP O O D EXTERIOR 1 2 ALUMINUM NG RAIL BOTTOMUFT RAIL 11 SASH PRD ALUMINUM ANDSHALLNOfN ONSOOO l-EOR, ALTS S,AD ITIOW,TDFRUILNNG DROPS,ING ALTFMTION;ADDRIONS,HIGINGHIING,OR NWIDNGSTDTNLS OONMENTARE MIf1EDADAN0 MIN.EDGE ou¢RrniuTION. oN. . DISTANCE xvnu11J1i17111�/ D HORIZONTAL SECTION E VERTICAL SECTION ANCHOR SCHEDULE \• METHOD SUBSTRATE ANCHOR SCHEDULE MIN EMBEDMENT MIN.EDGE �` •• O '�I� >; 6 NAIL FIN(JAMB) 6 MEETING STILE OIsrANCE R WOOD:MIN.SG=0.55 A8 WOOD SCREW D 1.5' 0.75'PAN �` :•�\•E••S•• �O ® INSTALLATION NOTES: ? N .7 Z NAILING FIN 3 THREADS MIN ' y, METAL:18 GAUGE Steel, N8 TEK SCREW PENETRATION BEYOND 0.60' 1. ONE(1)INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. MIN.Fy=33KSI ATIONMETAL ® 'O S-A- OF Q^ 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION OF TH #10 PAN HEAD INE r pp1.17 0.75' MAXIMUM SIZE LISTED. EXTERIOR CHANNEL W )pP.• ��L`� 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF±1/2 INCH THE DEPICTED LOCATION&SPACING IN THE ANCHOR LAYOUT WOOD:MIN.SG=0.55 #10 FLAT HEAD IN THE 'S, O O 1.5' 0.76' DETAILS(I.E.,WITHOUT CONSIDERATION OFTOLERANCES).TOLERANCESARE NOTCUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEM. IN7ERIORCHANNEL Idp YORecb+�E FLORIDA P.E.No 73770 BMDNO DROPS INC 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S).MAXIMUM ALLOWABLE SHIM STACK TO BE 3/8 INCH.SHIM AHO PAN HEAD IN pEN3ETRATON BMIN 0.50' 389°AIM A BEACH BLVD. L W1 338WHERE SPACE OF 1/16 INCH OR GREATER OCCURS.SHIM(S)SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. EXTERIOR CHANNEL E METAL:18 GAUGE Steel, METAL RIPE CERT.OF AUTIOMZATON No M578 5. FOR MASONRY OR CONCRETE OPENINGS,IX WOOD BUCK MAY BE USED(OPTIONAL AS LONG AS THE MINIMUM EMBEDMENTAND EDGE MIN.Fy=33K51 3 THREADS MIN FL#: #IN FLAT HEAD IN THE PENETRATION BEYOND 0.60' F L 14911 DISTANCE REQUIREMENTS ARE STILL MET WITHIN THE CORRESPONDING HOST SUBSTRATE.SEE GENERAL NOTE#3 ON SHEET 1 FOR MORE INTERIOR CHANNEL INFORMATION. METAL $ THROUGH FRAME 3/16'RVJ TAPCON 6. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES,INCLUDING BUT NOT LIMITED TO STUCCO,FOAM,BRICK VENEER,AND FLAT HEAD IN INTERIOR 1.26' 1.75' DATE: 01,23.18 SIDING. CONCRETE:fG3000PSI CHANNEL HEX HEAD IN EXTERIOR 125' 1.76• 3/16'ITWTAPCON DING.YY: CHK.BY 7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT CHANNEL COATING. 3/IB'frWTAPCON SCALE: NTS 8. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK,DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS.EDGE DISTANCE IS MEASURED FLATHEAD IN INTERIOR 1.25• +.76• DWG.#: SW D050 eL MASONRY:CMU Pet ASrHE-EZE CHANNEL FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. CSD MIN.2000 PSI SHEET: TAPCON 9. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS EXTERIOR 1.25' 1.75• SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. NEL 10. FOR INSTALLATION ANCHORS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK,USE FLATHEAD ANCHORS. OF 5