HomeMy WebLinkAboutProduct Approval 17101812 - 16' NOA 36-44`Ktesta t, M,7 D y 1 1 1 1CO"TTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F (7W 3li-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/eeouomv DAB Door Company, Inc. 12195 NW 98' Avenue Hialeah Gardens, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Hurricane Master® Model 824/811 Steel Sectional Garage Door 16'-2" Wide with Window Lite Option (DP +036.0,44.0 PSF) APPROVAL DOCUMENT: Drawing No. 02-21 Rev L, titled 1124 GA. Roll Formed Steel Sectional Garage Door", dated 09/10/2002 and last revised on OCT 05, 2017, sheets 1 through 5 of 5, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo, manufacturing address, model/series number, the positive and negative design pressure rating, indicate impact rated if applicable, installation instruction drawing reference number, approval number (NOA), the applicable test standards, and the statement reading `Miami -Dade County Product Control Approved' is to be located on the door's side track, bottom angle, or inner surface of a panel. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 15-0304.01 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq 1. Chanda, P.E. NOA No. 17-1018.12 Expiration Date: July 21, 2020 Approval Date: December 14, 2017 Page 1 DAB Door Companv, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted in previous files A. DRAWINGS 1. Drawing No. 02-21, titled "24 GA. Roll Formed Steel Sectional Garage Door", dated 09/10/2002, with last revision K dated 03/09/2015, sheets I through 5 of 5, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS "Submitted under NOA # 11-0414.12" 1. Test Report on Uniform Static Air Pressure Test, Loading and Forced Entry Test per FBC, TAS 202-94, of "DAB 824 Sectional Residential Garage Door" prepared by Hurricane Engineering & Testing Inc., Report No. HETI-07-4200, dated 05/02/2007, signed and sealed by Candido F. Font, P.E. 2. Test Report on Large Missile Impact Test per FBC, TAS 201-94 and Cyclic Wind Pressure Test per FBC, TAS 203-94, of "DAB 824 Sectional Residential Garage Door", prepared by Hurricane Engineering & Testing Inc., Report No. HETI-11-3204, dated 01/20/2011, signed and sealed by Candido F. Font, P.E. 3. Test Report on Tensile Test per ASTM E8-08 of "Sectional Residential Door (skin)", prepared by Hurricane Engineering & Testing Inc, Report No. HETI-11-T100, dated 01/21/2011, signed and sealed by Candido F. Font, P.E. "Submitted under NOA # 05-0228.02" 4. Test Report on Large Missile Impact Test and Cyclic Wind Pressure Test, of "Sectional Residential Door with Windows", prepared by Hurricane Engineering & Testing Inc., Report No. HETI 03-1328, dated 07/15/2003, signed and sealed by Rafael E. Droz-Seda, P.E. 5. Test Report on Uniform Static Air Pressure Test, of "Sectional Residential Door" prepared by Hurricane Engineering & Testing Inc., Report No. HETI 03-1329, dated 07/15/2003, signed and sealed by Rafael E. Droz-Seda, P.E. 6. Test Report on Tensile Test per ASTM E-8 of "Sectional Residential Door (skin)", prepared by Hurricane Engineering & Testing Inc, Report No. HETI 03-T078, dated 10/31/2003, signed and sealed by Rafael E. Droz-Seda, P.E. "Submitted under NOA # 03-0210.04" 7. Test report on Salt Spray (Corrosion) Test per ASTM B 117 of a painted G-40 steel panels, prepared by Celotex Corporation, Test Report No. 258592, dated 08/17/1998, signed by W. A. Jackson, P.E. C. CALCULATIONS "Submitted under NOA # 14-0814.10" 1. Anchor verification calculations prepared by Al-Farooq Corporation, dated 09/22/2014 and 07/24/2014, signed and sealed by Javad Ahmad, P.E. C,L,.fl\.CkoW �� Ishaq I. Chanda, P.E. Product Control Examiner NOA No. 17-1018.12 Expiration Date: July 21, 2020 Approval Date: December 14, 2017 E-1 DAB Door Companv, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS (Cont.) "Submitted under NOA # 11-0414.12" 2. Anchor verification calculations prepared by Al-Farooq Corporation, complying with F.B.0 2007, dated 04/07/2011, signed and sealed by Javad Ahmad, P.E. 3. Anchor verification calculations prepared by Al-Farooq Corporation, complying with F.B.0 2007, dated 12/19/2008, signed and sealed by Humayoun Farooq, P.E. "Submitted under NOA # 09-0128.02" D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 13-0717.01, issued to SABIC Innovative Plastics, for their Lexan Sheet Products, approved on 11/28/2013 and expiring on 07/17/2018. 2. Notice of Acceptance No. 14-0311.08, issued to Insulfoam, LLC, for their Insulfoam Expanded Polystyrene Insulation, approved on 08/14/2014 and expiring on 11/29/2017. 3. Notice of Acceptance No. 11-0926.07, issued to Dyplast Products, LLC, for their Expanded Polystyrene Block Type Insulation, approved on 11/10/2011 and expiring on 01/11/2017. 4. Notice of Acceptance No. 11-0926.06, issued to Dyplast Products, LLC, for their Dyplast ISO -C1 Polyisocyanurate Insulation, approved on 11/10/2011 and expiring on 01/11/2017. 5. Notice of Acceptance No. 10-1129.04, issued to Cellofoam North America Inc, for their Expanded Polystyrene Block Insulation, approved on 02/24/2011 and expiring on 02/24/2016. "Submitted under NOA # 05-0228.02" 6. Test Report on Accelerated Weathering Using Xenon Are Light Apparatus Test per ASTM G155 of "PVC Extrusion Material', prepared by Hurricane Engineering & Testing, Inc., Report No. HETI 04-A002, dated 09/27/2004, signed and sealed by Rafael E. Droz-Seda, P.E. 7. Test Reports on Tensile Test per ASTM D638 of "PVC Extrusion Material', prepared by Hurricane Engineering & Testing Inc., Report No. HETI 04-T251, dated 11/29/2004 signed and sealed by I. Ghia, P.E. 8. Test Report on Self -Ignition Temperature Test, Rate of Burn Test and Smoke Density Test of "REHAU non -foam PVC extrusion material', prepared by ETC Laboratories, Report No. 04-761-15019.0, dated 05/06/2004, signed and sealed by J. L. Doldan, P.E. F. STATEMENTS "Submitted under NOA # 14-0814.10" 1. Statement letter of code conformance to the 5m edition (2014) FBC and no financial interest issued by Al-Farooq Corporation, dated 05/13/2014, signed and sealed by Javad Ahmad, P.E. Ishaq I. Chanda, P.E. Product Control Examiner NOA No. 17-1018.12 Expiration Date: July 21, 2020 Approval Date: December 14, 2017 E -2 DAB Door Company, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUB 2. New Evidence submitted. A. DRAWINGS 1. Drawing No. 02-21 Rev L, titled "24 GA. Roll Formed Steel Sectional Garage Door", dated 09/10/2002 and last revised on OCT 05, 2017, sheets 1 through 5 of 5, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. Note: This revision consist of editorial changes to comply with FBC 2017. B. CALCULATIONS 1. None C. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). D. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0221.06, issued to Insulfoam, LLC, for their Insulfoam Expanded Polystyrene Insulation, expiring on 11/29/2022. 2. Notice of Acceptance No. 16-1108.04, issued to Dyplast Products, LLC, for their Dyplast ISO -C1 Polyisocyanurate Insulation, expiring on 01/11/2022. 3. Notice of Acceptance No. 15-1203.04, issued to Cellofoam North America Inc, for their Expanded Polystyrene Block Insulation, expiring on 02/24/2021. 4. Notice of Acceptance No. 15-0915.08, issued to SABIC Innovative Plastics, for their Lexan Sheet Products, expiring on 07/17/2018. E. STATEMENTS 1. Statement letter of conformance to FBC 2014 (5th Edition) and FBC 2017 (61h Edition), prepared by Al Farooq Corporation, dated 10/05/17, signed and sealed by Javad Ahmad, P.E. F. OTHER 1. This NOA revises NOA 415-0304.01, expiring 07/21/20. `4thfj \. L\, Ishaq I. Chanda, P.E. Product Control Examiner NOA No. 17-1018.12 Expiration Date: July 21, 2020 Approval Date: December 14, 2017 E -3 p 7-1/2" X 2-1/4" X 18 GA. ------Pu! GALV. STEEL CENTER HINGE ` O W/ (4) #14 X 5/8" SMS WITHOUT DELRON SLEEVE (STD.) p 7-1/2" X 3" X .071" GALV. STEEL I 00 END ROLLER HINGE II 00 W/ (6) #14 X 5/8" SMS WITHOUT DELRON SLEEVE (STD.) i WITH DELRON SLEEVE (OPTIONAL) 7-1/2" X 2-1/4" X .071" LOCK GALV. STEEL CENTER HINGE 0 W/ (4) #14 X 5/8" SMS 2/ DOOR O WITH DELRON SLEEVE (OPTJ.GMI O I 1" W X .15 THK. LATCH I I CENTER HINGE STANDARD LOCK SPRING LOADED SLIDE BOLT (BOTH SIDES FASTENED W/ (4) #14 X 1/2" S.M.S. 5/8" MIN. LOCK ENGAGEMENT CONFORMS TO SECTION 1008 REGARDING GARAGE DOORS ------ `\- _ .158 DIA. GALV. AIRCRAFT TYPE CABLE & NICO -PRESS SLEEVE W/ MIN. 5 TO 1 SAFETY FACTOR / I O+ 711 71 I 2-3/4"W X 5-5/8"H X .090" THK.77 JLOWIZ STEEL PLATE, 1-3/8" DEEWITH (3) #14 X 3/4SELF DRILLING SCREWSBRACKETBRACKETSTD. LIFT DOOR HEADROOM OR OPTION DOOR HEIGHT CONSISTS OF TOTAL # OF 'U' BARS AT EACH DOOR 6'-6" 2 SECTIONS 18" 2 SECTIONS 21" p o o a 0 m 6'-9" 1 SECTION 18" 3 SECTIONS 21" 7' 4 SECTIONS 21" - 7'-3" 7'-6" 5 SECTIONS 18" - 7'-9" 4 SECTIONS 18" 1 SECTION 21" 8' 13 SECTIONS 18" 2 SECTIONS 21" 8'-3" 2 SECTIONS 18" 3 SECTIONS 21" 8'-6" 1 SECTION 18" 4 SECTIONS 21" 8'-9" 5 SECTIONS 21" - 9' 6 SECTIONS 18" - 9'-3" 5 SECTIONS 18" 1 SECTION 21" 9'-6" 4 SECTIONS 18" 2 SECTIONS 21" 9'-9" 3 SECTIONS 18" 3 SECTIONS 21" 10' 2 SECTIONS 18" 4 SECTIONS 21" 10'-3" 1 SECTION 18" 5 SECTIONS 21" 10'-6" 16 SECTIONS 21" - 10'-9" 6 SECTIONS 18" 1 SECTION 21" 11' 5 SECTIONS 18" 2 SECTIONS 21" 11'-3" 4 SECTIONS 18" 3 SECTIONS 21" 11'-6" 3 SECTIONS 18" 4 SECTIONS 21" 11'-9" 2 SECTIONS 18" 5 SECTIONS 21" 12' 1 SECTIONS 18" 6 SECTIONS 21" 12'-3" 7 SECTIONS 21" - 12'-6" 6 SECTIONS 18" 2 SECTIONS 21" 12'-9" 5 SECTIONS 18" 3 SECTIONS 21" 13' 4 SECTIONS 18" 4 SECTIONS 21" 3 SECTIONS 18" 5 SECTIONS 21" 13'-6" 2 SECTIONS 18" 6 SECTIONS 21" 13'-9" 1 SECTION 18" 7 SECTIONS 21" 14' 8 SECTIONS 21" - 14'-3" 6 SECTIONS 18" 3 SECTIONS 21" 14'-6" 5 SECTIONS 18" 4 SECTIONS 21" 14'-9" 4 SECTIONS 18" 5 SECTIONS 21" 15' 3 SECTIONS 18" 6 SECTIONS 21" 15'-3" 2 SECTIONS 18" 17 SECTIONS 21" 15'-6" 1 SECTION 18" 18 SECTIONS 21" 15'-9" 19 SECTIONS 21 16' 16 SECTIONS 18" 4 SECTIONS 21- G 7-7/8" X 3-1/8" X .010" STEEL PLATE WITH (4) #14 X 3/4" SDS NUT TOP FIXTURE 5-1/2" X 2-3/4" X 0.1" STEEL PLATE WITH ONE 5/16-18 MS W/ NUT �FASTENED TO END STILE WITH (6) #14 X 3/4" SELF DRILLING SCREWS SEE SHEEP 3 FOR TOP BRACKET OPTIONS CENTER STILES OPTIONAL DOOR VIEWER TO BE INSTALLED AT ANY CENTER STILE7 it; -2 THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT QL INSIDE ELEVATION BUILDING DINGOR SCODE, TASTED IN -202, TAS 201 & TASNCE WITH THE -2 203 EFORTHVOZ AND IDA RAISED PANEL EMBOSSED DOOR ASTM E7886-05/ASTM E1996-09. END STILE JLOCK BAR GUIDES INSTALLED ON END STILE WITH (4) #14 X 5/8" SMS .18T X .6W LOCK BAR ENGAGES IN TRACK ON EACH SIDE OF DOOR OUTSIDE KEYED LOCK OPTIONAL LOCK BAR LOCKING SHOWN ALTERNATE TO SPRING LOADED SLIDE BOLT LOCKS SHOWN ABOVE g'-0" TO 9'-10" DOOR WIDTHS STILES DAB DOORS INC. Hurricane Master® Model 824/811 Max. Size 16'-2" X 16'-0" High With Window Lite Option DESIGN PRESSURE RATING = + 36.0 PSF — 44.0 PSF SCHEDULE 'A' CENTER STILES CONFIGURATION DOOR WIDTHS # OF CENTER STILES 8'-0" TO 9'-10" 2 10'-0" TO 11'-10" 2 12'-0" TO 13'-10" 3 14'-0" TO 15'-10" 4 15'-11" TO 16'-2" 5 I r0711 LOPTIONAL VENTS �OPTIONAL FLUSH FACE OPNG. AREA NOT TO EXCEED 120 SO. IN. MAX. DOOR WIDTH WOOD GRAIN DESIGN A it; -2 THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT QL INSIDE ELEVATION BUILDING DINGOR SCODE, TASTED IN -202, TAS 201 & TASNCE WITH THE -2 203 EFORTHVOZ AND IDA RAISED PANEL EMBOSSED DOOR ASTM E7886-05/ASTM E1996-09. END STILE JLOCK BAR GUIDES INSTALLED ON END STILE WITH (4) #14 X 5/8" SMS .18T X .6W LOCK BAR ENGAGES IN TRACK ON EACH SIDE OF DOOR OUTSIDE KEYED LOCK OPTIONAL LOCK BAR LOCKING SHOWN ALTERNATE TO SPRING LOADED SLIDE BOLT LOCKS SHOWN ABOVE g'-0" TO 9'-10" DOOR WIDTHS STILES DAB DOORS INC. Hurricane Master® Model 824/811 Max. Size 16'-2" X 16'-0" High With Window Lite Option DESIGN PRESSURE RATING = + 36.0 PSF — 44.0 PSF SCHEDULE 'A' CENTER STILES CONFIGURATION DOOR WIDTHS # OF CENTER STILES 8'-0" TO 9'-10" 2 10'-0" TO 11'-10" 2 12'-0" TO 13'-10" 3 14'-0" TO 15'-10" 4 15'-11" TO 16'-2" 5 GENERAL NOTES 1. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2014 (5TH EDITION)/2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 2. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 3. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. 4. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2014/2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS. 5. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ErC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL 6. MANUFACTURER'S LABEL SHALL BE LOCATED ON A READILY VISIBLE LOCATION IN ACCORDANCE WITH SECTION 1709.9.3 OF FLORIDA BUILDING CODE. LABELING TO COMPLY WITH SECTION 1709.9.2. ® ® ® ® ® ® MAY BE3USEDSELF DRILLING SCREWS IN LIEU OF #14 X 5/8" SMS 14'-0" TO 15-10" _ `- DOOR WIDTHS 1—II I��I � ILII Ir ��I 7 • • • uwn rnuino my ftU Z M r 0� Mw 2 N W � Q J N JL Q 6 d'oo`m a�W it O F O�0'h >M Cf 0 paoo.I OIg UI N� Q W M IO J N �^ LL W 0 0 KOES QwmE� A)E OR=��\ (( drawing no. ®!1®?e ��°.�� 02-21 X 2-1/4" X 3/4" X 2" uALv. STEEL U.BAR REINFORCING TRUSS ® BOTTOM OF PANEL TRUSS FASTENED TO VERTICAL INTERMEDIATE STILES W/ TWO #14 X 5/8" S.M.S. AND TO END STILE W/ FOUR #14 X 3/4" SELF DRILLING S. IST SECTION (BOTTOM) STEEL TRACK BRACKET FASTENED TO WOOD JAMB WITH 5/16" X 1-5/8" LAG SCREW (FULLY THREADED) HEX WASHER HEAD TYPE A ONE PER BRACKET SOUTHERN PINE ...- 0.55 S. 1 I 1.9" X 2.19" X 3.3" X .090" STEEL TRACK BRACKETS - SEE SHEET 3 FOR SPACING INTERMEDIATE SECTION OPTIONAL STOP MOULDING BY DOOR INSTALLER # 14 X 5/8" SMS 6 PER HINGE TOP SECTION 4DIST 1/2" X 1-3/4" X .058" FORMED STEEL GLUED TO PANEL AND SECURED TO END STILE WITH (4) 3/16" POP RIVETS 1-7/8" X 2-5/8" X .049" STEEL CENTER STILE, GLUED AND RIVETED TO PANEL W/ (4) 3/16" RIVETS 3/16" POP RIVETS r4/1 HINGE4 X /8" S.M.S. / STEEL TRACK 14 GA. X 2-1/8" X 1" (STANDARD) 12 GA. X 3-5/16" X 1-1/2" (OPTIONAL) FASTENED TO TRACK PLATES W/ 1/4-20 X 5/8" TRUSS HD. SLOTTED M.S. & LOCK NUT i 7-1/2" X .050" GALV. STEEL _ CENTER HINGE INTERIOR SIDE 7/8" PUSHNUT INSTALLED ON ROLLER SHAFT SECTION B -B 24 GA. STEEL PANEL yI_1r�:7:17�1ty�/� 7 1/2" PUNCHED HOLES ® 4" O.C. 0. 3/16" POP RIVETS J AT 4" O.C. (6) FOR 21" STILES (5) FOR 18" STILES END STILE ftmavc at w. Q with tie ! AtmWEAce No 17 -toll. 12- F�iM#oe. qtr O Product G SOLID BRASS DOOR VIEWER PANELS WITH BY 'SCHLAGE SECURITY HARDWARE' END STILE, CONNECT TO PANE 3/4" x 2" x 2-1/2" X STEEL INSTALLED IN 9/16" DIA. HOLES IN CENTER STILE FLAPS AND (5) OR (6) 3/16" ALUM RIVETS POSITIONED AT EYE LEVEL SEE DETAIL ABOVE 7-1/2" X .071"-J\x END ROLLER HINGE —,)//\ 1.82" DIA. X .50" STEEL ROLLERS (STD.) 1.82" DIA. X .50" NYLON ROLLERS (OPTIONAL) 2.75" DIA. X .50" STEEL ROLLERS (OPTIONAL) 2.75" DIA. X .50" NYLON ROLLERS (OPTIONAL) WITH 5" STEM 1/4-20 SS BOLTn e & NUTEOF - y�U Z go m Z N W Q d C N O OJO`a CL N F Tai. 0 O N opui� O'OZM O d O0CN 003Lulr O N Q W 7 LL N {LZM -O O2 ro zM Q woi� r 11=1. 0 0 0 drawing no. 02-21 sheet 2of 5 ANCHORS AT TRACK BRACKET: EDGE r DISTANCE A) 3/8" DIA, POWER -BOLT BY 'POWERS' 2" MIN. EMBED INTO CONCRETE (3000 PSI MIN.) 2" MIN. EDGE DISTANCE 3/8" DIA, HLC SLEEVE BY 'HILT] B) 1-1/4" MIN. EMBED INTO CONCRETE OR FILLED BLOCK 2-1/4" MIN. EDGE DISTANCE INTO CONCRETE 4" MIN. EDGE DISTANCE INTO FILLED BLOCK CONCRETE fVc = 3000 PSI MIN. i(l) C-90 GROUT FILLED BLOCK f'm = 2000 PSI MIN. ANCHOR TYPE A OR B PER BRACKET B4IIE4/�® SEE SHEET 3 FOR BRACKET SPACING 0�9\4 7-1/2" X .071"-J\x END ROLLER HINGE —,)//\ 1.82" DIA. X .50" STEEL ROLLERS (STD.) 1.82" DIA. X .50" NYLON ROLLERS (OPTIONAL) 2.75" DIA. X .50" STEEL ROLLERS (OPTIONAL) 2.75" DIA. X .50" NYLON ROLLERS (OPTIONAL) WITH 5" STEM 1/4-20 SS BOLTn e & NUTEOF - y�U Z go m Z N W Q d C N O OJO`a CL N F Tai. 0 O N opui� O'OZM O d O0CN 003Lulr O N Q W 7 LL N {LZM -O O2 ro zM Q woi� r 11=1. 0 0 0 drawing no. 02-21 sheet 2of 5 POP RIVETS 2-3/4" X 5-1/2" X 3" X .104" GALV. STEEL TOP ROLLER BRACKET ON EACH SIDE FASTENED W/ (6) # 14 X 5/8" S.M.S. 14 GA. GALV. STEEL ADJUSTABLE SLIDE FASTENED TO BRACKET W/ 5/16-18 X 3/4" HEX HEAD M. SCREWS & NUTS. 'nmv) TOP BRACKET (OPTIONAL) LOW HEADROOM DOOR HORIZONTAL REINFORCEMENT 1 /7" X 1-3/4" X .058" FORMED STEEL D TO PANEL AND FASTENED TO CAL STILES WITH 2" X 5-1/2" X .104" i/16' POP RIVETS GALV. STEEL FASTENED W/ (4) # 14 X 5/8" S.M.S. TOP ROLLER BRACKET FOR LOW HEADROOM DOOR OPTION HORIZONTAL REINFORCEMENT 1/2" X 1-3/4" X .058" FORMED STEEL GLUED TO PANEL AND FASTENED TO VERTICAL STILES WITH (2) 3/16" POP RIVETS J W ( 1-5/8" LAG SCREWS INTO WOOD OR 5/16" SLEEVE ANCHORS WITH 1-1/4" EMBED INTO MASONRY 3 PER BRACKET /2" X 4-1/4" X 13 GA. STEEL PLATES TO 1-1/2" X 1-1/2" X 14 GA. ANGLE FASTENED TO TRACK WITH (4) 1/4-20 SS. BOLT & NUTS 5/16" MEETING RIB PLASTIC/STEEL ROLLERS 1.82" DIA. X .50" W/ .44 DIA. X 4-1/4" STEM SECTION A -A SEE SHEET 2 FOR LOCATION OF REINFORCING TRUSSES OPTIONAL INSULATIONS: BY 'DYPLAST PRODUCTS LLC' ISO -25 POLY—ISOCYANURATE DENSITY = 2.0 PCF N.O.A. #16-1108.04 OR BY 'CELLOFOAM NORTH AMERICA' DENSITY = 1.03 PCF N.O.A. #15-1203.04 OR BY 'INSULFOAM LLC' DENSITY = 0.92 PCF N.O.A. #17-0221.06 14 GA. GALV. STEEL ROLLER HINGES FASTENED W/ (6) # 14 X 5/8" SMS MIN. .024" ROLL FORMED STEEL PANEL DRAWING QUALITY G-40 MIN. YIELD STRENGTH = 39 KSI WITH PRIMER AND BAKED—ON POLYSTER PAINTED TOP COAT APPLIED TO BOTH SIDES OF STEEL 12 GA. GALV. STEEL BOTTOM BRACKET FASTENED W/ (4) If 14 X 5/8" SMS BOTTOM SEAL OPTIONS SEE SHEET 5 HORIZ. TRACK SUPPORT, CENTER SUPPORT READ. ON DOORS EXREEDING 8 FT. IN HEIGHT II II A —� II A—I = OPENING HEIGHT PLUS 12" 14 GA. GALV. STEEL TRACK 1-1/2" X 1/2" X 1/8" HORIZ. ANGLE FOR DOOR HEIGHTS UPTO 8 FT. WITHOUT INSULATION OR WINDOWS, 2" X 2" X 1/8" HORIZ. ANGLE FOR DOOR HEIGHTS ABOVE 8 FT. OR DOORS WITH INSULATION OR WINDOWS SPOT WELDED TO HORIZ. TRACK WITH TWO WELDS AT 1-1/2" APART FIRST AT 3" O.C., REST AT 9" O.C. CONNECTED TO FLAG BRACKET ANGLE W/ 3/8-16 X 3/4" BOLT & NUT AND TO SPRING SHAFT GUIDE WITH (2) 1/4-20 X 5/8" BOLT & NUT VERTICAL TRACK_ 2-1/8" X 1" X .080" SECTION A -A DOOR * SECTION HEIGHTS BRACKET PLACEMENTS HEIGHT 1ST 2ND 3RD 4TH 5TH Bt B2 B3 B4 B5 86 B7 B8 6'-0" 18" 18" 18" 18" N/A 1" TO 2" 11-3/4" 23" 34" 45" 56" 67" — 6'-6" 21" 18" 18" 21" N/A 1" TO 2" 11-3/4" 23" 34" 45" 56" 67" — 7'-0" 21" 21" 21" 21" N/A 1" TO 2"11-3/4" 23" 34" 45" 56" 67" — 7'-6" 18" 18" 18" 18" 18" 1" TO 2" 11-3/4" 23" 34" 45" 56" 67" 78-1/4" 8'-0" 21" 18" 18" 18" 21" 1" TO 2" 11-3/4" 23" 34" 45" 56" 67" 78-1/4" *—SECTIONS ARE NUMBERED STARTING AT THE BOTTOM FOR DOORS MORE THAN 8 FT. HIGH, USE ADDITIONAL TRACK BRACKETS AT 10" O.C. rl II 1.9" X 2.19" X 3.3" X .090" STEEL TRACK BRACKETS m 2-3/16" HIGH CONNECTED TO TRACK WITH 1/4" BOLTS & NUTS. m r, TRACK CONFIGURATION VERTICAL LIFT REVISM ylog with the Fkwwb nR Cade Acceplasce Na — 6 U14 p tt DYtf SAO rode" caffitAw HIGH LIFT STANDARD LIFT AVAILABLE TRACK OPTIONS i _ c LOW HEADROOM DOUBLE TRACK '°A#14f'// .7 51,92 TA ®R (0y"U U1= N 0 0 0 o I � T � a O V t drawing no. 02-21 sheet 3 of OPTION 'A' OPTION 'B' WOOD BUCK CONNECTION TO WOOD SUBSTRATE (WOOD SPECIFIC GRAVITY SG=0.55 MIN.) THE INSTALLATION METHODS SHOWN ABOVE SHOWS 2X6 SYP WOOD BUCK ATTACHMENT TO WOOD STRUCTURES. IF THESE METHODS ARE FOLLOWED NO ADDITIONAL CALCULATIONS/DESIGN WILL BE REQUIRED FOR DESIGN OF GARAGE DOOR ANCHORAGE. FOR DOOR REPLACEMENT APPLICATIONS WITH NO ENGINEER OF RECORD, INSTALLATION MAY BE VERIFIED AND APPROVED BY THE BUILDING OFFICIAL UPON INSPECTION. 5/16" X 1-5/8" LAG SCREWS AT 12" O.C. WOOD BUCK CONNECTION TO MASONRY ° PRESSURE TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO GROUTED REINFORCED MASONRY BLOCK WALL OR CONC. COLUMN WITH 1/4" ULTRACON BY 'ELCO' WITH SPACING OF 12" O.C. INTO GROUT FILLED BLOCK WALL, WITH 2-1/4" MIN. EMBED 13" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 2-1/2" MIN. EDGE DISTANCE I 1-1/2- 1/4" TAPPER BY 'POWERS' WITH SPACING OF 11" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/2" MIN. EMBED 13" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 3" MIN. EDGE DISTANCE 3/8" CONFLEX BY 'ELCO' OR 3/8" LOT BY 'ITW' WITH SPACING OF 23" O.C. INTO 3000 PSI CONCRETE, WITH 2-1/2" MIN. EMBED 3" MIN. EDGE DISTANCE CONTINUOUS ANGLE TRACK 3/8" HLC SLEEVE BY 'HILTI' WITH SPACING OF TO WOOD BUCK 10" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/4" MIN. EMBED, 4" MIN. EDGE DIST. 15" O.C. INTO 3000 PSI CONCRETE, WITH 1-1/4" MIN. EMBED AND 2-1/2" MIN. EDGE DISTANCE PREPARATION OF JAMBS BY OTHERS FOR NEW CONSTRUCTION ENGINEER OF RECORD OR ARCHITECT TO VERIFY ADEQUACY OF SUPPORTING STRUCTURE TO SUPPORT LOADS IMPOSED BY DOOR SYSTEM. FOR DOOR REPLACEMENT IN RETROFIT BUILDINGS WITH NO ENGINEER OF RECORD, DOOR INSTALLATION MAY BE REVIEWED AND APPROVED BY BUILDING OFFICIAL UPON INSPECTION. MAXIMUM EXTERIOR(+) LOAD PER JAMB = (16.16' X 62 PSF)/2 = 291 Lbs per Ft. MAXIMUM INTERIOR(-) LOAD PER JAMB = (16.16' X 44 PSF)/2 = 355.5 Lbs per Ft. 1/16" X 2 -1/2 - FILLET WELDS AT 12" O.C. MAX. W'STRIP ADAPTER ALUMINUM RUBBER W'STRIPPING STEEL STRUCTURE BY OTHERS MUST SUPPORT THE LOADS IMPOSED BY DOOR SYSTEM 1-1 REVERSE TRACK TO STEEL 224 050�/�'� \� LC21.534 ��1.750—iII � 5/16" DIA. BOLTS WITH WASHER & NUT AT 12" O.C. MAX. ALTERNATE TRACK INSTALLATION REINFORCEMENT 1/2" X 1-3/4" X .058" FORMED STEEL #8 X 1" SELF DRILLING SCREWS OR 3/16" 'RIVER' STEEL RIVETS MULTIGRIP W/ DOME HEAD AT 48" O.C. O W'STRIP ADAPTER STEEL .040 700 .348 1.790 BOTTOM SEAL OPTIONS W'STRIPPING PROI-f UCfREV6$ m tv PIyiflg with the FJwWb boating Code AMPlance No Espi ate ANCHOR SPACING N r W � DIST. #8 X 1- w Z EMBED 1-1/2" MIN. EDGE DIST. SELF DRILLING SCREWSOR CONC. 1-i/4" 8" 2" 3/8- CONFLEX BY 'ELCO' FILLED BLOCK 2" DIST. o 3-3 4" m 3/16" 'RIVER' STEEL RIVETS o� C) m m 1-1 2" iv 2-1/2" a MULTIGRIP W/ DOME HEAD 3 N \_ w 2" 7GE \_ 2" a AT 48" O.C. 860 CONC. 1-1 2" p N0+ N p w C Ib0 � p N REINFORCEMENT C) � 0 1/2" X 1-3/4" X .058" O Z D N U FORMED STEEL 2BY 1/4" DIA. LAG SCREWS 2BY ro 1 1/4" DIA. LAG SCREWS WOOD I AT 6" FROM ENDS WOOD BUCk AT 6" FROM ENDS AND 15" O.C. MAX. I AND 15" O.C. MAX. OPTION 'A' OPTION 'B' WOOD BUCK CONNECTION TO WOOD SUBSTRATE (WOOD SPECIFIC GRAVITY SG=0.55 MIN.) THE INSTALLATION METHODS SHOWN ABOVE SHOWS 2X6 SYP WOOD BUCK ATTACHMENT TO WOOD STRUCTURES. IF THESE METHODS ARE FOLLOWED NO ADDITIONAL CALCULATIONS/DESIGN WILL BE REQUIRED FOR DESIGN OF GARAGE DOOR ANCHORAGE. FOR DOOR REPLACEMENT APPLICATIONS WITH NO ENGINEER OF RECORD, INSTALLATION MAY BE VERIFIED AND APPROVED BY THE BUILDING OFFICIAL UPON INSPECTION. 5/16" X 1-5/8" LAG SCREWS AT 12" O.C. WOOD BUCK CONNECTION TO MASONRY ° PRESSURE TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO GROUTED REINFORCED MASONRY BLOCK WALL OR CONC. COLUMN WITH 1/4" ULTRACON BY 'ELCO' WITH SPACING OF 12" O.C. INTO GROUT FILLED BLOCK WALL, WITH 2-1/4" MIN. EMBED 13" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 2-1/2" MIN. EDGE DISTANCE I 1-1/2- 1/4" TAPPER BY 'POWERS' WITH SPACING OF 11" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/2" MIN. EMBED 13" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 3" MIN. EDGE DISTANCE 3/8" CONFLEX BY 'ELCO' OR 3/8" LOT BY 'ITW' WITH SPACING OF 23" O.C. INTO 3000 PSI CONCRETE, WITH 2-1/2" MIN. EMBED 3" MIN. EDGE DISTANCE CONTINUOUS ANGLE TRACK 3/8" HLC SLEEVE BY 'HILTI' WITH SPACING OF TO WOOD BUCK 10" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/4" MIN. EMBED, 4" MIN. EDGE DIST. 15" O.C. INTO 3000 PSI CONCRETE, WITH 1-1/4" MIN. EMBED AND 2-1/2" MIN. EDGE DISTANCE PREPARATION OF JAMBS BY OTHERS FOR NEW CONSTRUCTION ENGINEER OF RECORD OR ARCHITECT TO VERIFY ADEQUACY OF SUPPORTING STRUCTURE TO SUPPORT LOADS IMPOSED BY DOOR SYSTEM. FOR DOOR REPLACEMENT IN RETROFIT BUILDINGS WITH NO ENGINEER OF RECORD, DOOR INSTALLATION MAY BE REVIEWED AND APPROVED BY BUILDING OFFICIAL UPON INSPECTION. MAXIMUM EXTERIOR(+) LOAD PER JAMB = (16.16' X 62 PSF)/2 = 291 Lbs per Ft. MAXIMUM INTERIOR(-) LOAD PER JAMB = (16.16' X 44 PSF)/2 = 355.5 Lbs per Ft. 1/16" X 2 -1/2 - FILLET WELDS AT 12" O.C. MAX. W'STRIP ADAPTER ALUMINUM RUBBER W'STRIPPING STEEL STRUCTURE BY OTHERS MUST SUPPORT THE LOADS IMPOSED BY DOOR SYSTEM 1-1 REVERSE TRACK TO STEEL 224 050�/�'� \� LC21.534 ��1.750—iII � 5/16" DIA. BOLTS WITH WASHER & NUT AT 12" O.C. MAX. ALTERNATE TRACK INSTALLATION REINFORCEMENT 1/2" X 1-3/4" X .058" FORMED STEEL #8 X 1" SELF DRILLING SCREWS OR 3/16" 'RIVER' STEEL RIVETS MULTIGRIP W/ DOME HEAD AT 48" O.C. O W'STRIP ADAPTER STEEL .040 700 .348 1.790 BOTTOM SEAL OPTIONS W'STRIPPING PROI-f UCfREV6$ m tv PIyiflg with the FJwWb boating Code AMPlance No Espi ate ANCHOR SPACING N r W � ANCHORS STRUCTURE EMBED I SPACING EDGE DIST. 3/8" HLC SLEEVE BY 'HILTI' CONC. 1-i/4" 8" 2" 3/8- CONFLEX BY 'ELCO' FILLED BLOCK 2" 8" 3-3 4" 3/8" DYNABOLT BY 'ITW' CONC. 1-1 2" 8" 2-1/2" 3/8" POWER -BOLT BY 'POWERS' CONC. 2" 8" 2" 3/8" SLEEVE -ALL BY 'SIMPSONS' CONC. 1-1 2" p CONCRETE Vc = 3000 PSI MIN. C-90 GROUT FILLED BLOCK Vm = 2000 PSI MIN. 1-1/4" X 2-1/2" X 14 GA CONT. STEEL ANGLE 12 GA. GALV. STEEL FLAT BRACKETS f3" LONG AT 12" O.C. IN DOOR OPNG. AT 18" O.C. ABOVE DOOR OPNG. CONNECTED TO CONT. ANGLE W/ (3) SPOT WELDS AT EACH SIDE EDGE DIST. 1-1/2" 2-1/8" X 1" X 14 GA. GALV. STEEL TRACK FASTENED TO TRACK PLATES W/ (2) 1/4-20X5/8" TRUSS HD. SLOTTED M.S. & LOCK NUT CONTINUOUS ANGLE TRACK TO CONCRETE AND FILLED BLOCK Pp A�Af N� 1,®GAN Sg ®. 0562 ST E OF� (0 4"U Zm A Z N QIL ?" IL 00°c+`m j N 1IQ-u F CUNT �% �We a¢mllo 0ILO<N NNO jLLW maNyzU)_ 02 JZM awmi � � � N r W � N m I N � M z o0..,. 0 L5 o v - rt x rt LE Q w O Ll a p S E� N p w C Ib0 � p N � C) � 0 n O Z D N U O D Lno 0] 0)Q ro Q N.0 N O 4 DOOR PANEL 24 GA. (.024) STEEL MIN. 7/16" DIA. WASHER O \1 #8 X 3/4" SMS ® 3/8- FROM ENDS AND 7" O.C. MAX. (4) #8 X 3/4" SMS @ 1-3/8" FROM ENDS AND 6-1/2" O.C. MAX. .175 X .062 DEEP GROOVE 1/4" POLYCARBONATE LEXAN BY 'SABIC INNOVATIVE PLASTICS' NOA #15-0915.08 .175 X .062 DEEP GROOVE (4) #8 X 3/4" SMS ® 1-3/8" FROM ENDS AND 6-1/2" O.C. MAX. #8 X 3/4" SMS ® 3/8" FROM ENDS AND 7" O.C. MAX. 7/16" DIA. WASHER DOOR PANEL 24 GA. (.024) STEEL MIN. i * PLASTIC COMPLIES WITH CHAPTER 26 OF FBC SEE EVIDENCE PAGE INSIDE ELEVATION RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS PRODUCf&EVISM � a+rl•g r itb the Fvwi WINDOW LITES CAN BE IN ANY LOCATION IN DOOR SECTION beAingC'Wa #8 X 3/4" SMS O A epfaacc NG '-' O "/ ® 3/8" FROM ENDS .175 X .062 DEEP AND 4-1/2" O.C. MAX.] GROOVE _ \ DOOR PANEL 24 GA. (.024) STEEL MIN. 15/16" MIN. 019Pi•]2A591111a EXTERIOR D.L. OPG. 0592 . Q TATE OF 0 0 N 0 I 0 0 T = 0 � � a° Lmj-` o drawing no 02-21