HomeMy WebLinkAboutProduct Approval 17101813 - 8' NOA 50-60M1AMFDADE MIAMI -DARE COUNTY
- c PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/econmnv
DAB Door Company, Inc.
12195 NW 98' Avenue
hialeah Gardens, FL 33018
,SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In
Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined
by Mian; Dade County Product Control Section that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has beer. designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: hurricane Master Model 824/811 Steel Sectional Garage Door up to 9'-4" Wide w/
Window Lite Option (DP +50.0,-60.0 PSF)
APPROVAL DOCUMENT: Drawing No. 01-09 REV L, titled "Sectional Garage Door", sheets 1 through
5 of 5, dated 02/01/2001 and last revised on OCT 05, 2017, prepared by Al-Farooq Corporation, signed and
sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp with the
Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: A permanent label with the manufacturer's name or logo, manufacturing address, model
number, the positive and negative design pressure rating, indicate impact rated if applicable, installation
instruction drawing reference number, approval number (NOA), the applicable test standards, and the
statement reading `Miami -Dade County Product Control Approved' is to be located on the door's side track,
bottom angle, or inner surface of a panel.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NCA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 16-0330.02 and consists of this page 1 and evidence pages Irl. E-2 and Er3, as
well as approval document mentioned above.
The submitted documentation was reviewed by Ishaq I. Chanda, P.E.
NOA No. 17-1018.13
Expiration Date: August 9, 2021
Approval Date: December 14, 2017
Page 1
DAB Door Company, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBNHTTED
1. Evidence submitted in previous files
1. Drawing No. 01-09, titled "Sectional Garage Door", sheets 1 through 5 of 5, dated
02/01/2001, with last revision K dated 03/21/2016, prepared by Al-Farooq Corporation,
signed and sealed by Javad Ahmad, P.E.
B. TESTS "Submitted under NOA # 09-0128.04"
1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
4) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94
along with marked -up drawings and installation diagram. of a DAB 824 24 GA
Sectional Garage Door with Fixed Windows, prepared by Hurricane Engineering &
Testing, Inc, Test Reports No. HETI-08-2149AM, dated 06/27/2008, signed and
sealed by Candido F. Font, P.E.
"Submitted under NOA # 09-0128.04"
2. Test report of Tensile Test per ASTM E 8, Report No. HETI 08-T182, prepared by
Hurricane Engineering & Testing, Inc., dated 12/23/2008, signed and sealed by
Candido F. Font, P.E.
"Submitted under NOA # 01-0515.03"
3. Test report of large missile impact test per PA 201 and cyclic wind pressure test per
PA 203 on "Sectional Residential Garage Door", prepared by Hurricane Engineering
& Testing, Inc., Report No. HETI 01-974A, dated 01/29/2001, signed and sealed by
Hector M. Medina, P.E.
4. Test report of Uniform Static Air Pressure Test per PA 202 and Force Entry
Resistance Test on "Sectional Residential Garage Door", prepared by Hurricane
Engineering & Testing, Inc., Report No. HETI 01-969, dated 01/18/2001, signed and
sealed by Hector M. Medina, P.E.
5. Test report on Salt Spray (Corrosion) Test per ASTM B 117 of a painted G-40 steel
panels, prepared by Celotex Corporation, Test Report No. 258592, dated 08/17/1998,
signed by W. A. Jackson, P.E.
Isbaq I. Chanda, P.E.
Product Control Examiner
NOA No. 17-1018.13
Expiration Date: August 9, 2021
Approval Date: December 14, 2017
E-1
DAB Door Companv, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
C. CALCULATIONS "Submitted under NOA # 14-0814.04"
1. Anchor verification calculations prepared by Al-Farooq Corporation, dated 09/22/2014 and
07/24/2014, signed and sealed by Javad Ahmad, P.E.
"Submitted under NOA # 09-0128.04"
2. Anchor verification calculations prepared by Al-Farooq Corporation, complying with F.B.0
2007, dated 12/19/2008, signed and sealed by Humayoun Farooq, P.E.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 15-0915.08, issued to SABIC Innovative Plastics, for their Lexan
Polycarbonate Sheet Products, approved on 12/10/2015 and expiring on 07/17/2018.
2. Notice of Acceptance No. 14-0311.08, issued to Insulfoam, LLC, for their
Insulfoam Expanded Polystyrene Insulation, approved on 08/14/2014 and expiring on
11/29/2017.
3. Notice of Acceptance No. 11-0926.07, issued to Dyplast Products, LLC, for their Expanded
Polystyrene Block Type Insulation, approved on 11/10/2011 and expiring on 01/11/2017.
4. Notice of Acceptance No. 11-0926.06, issued to Dyplast Products, LLC, for their
Dyplast ISO -Ci Polyisocyanurate Insulation, approved on 11/10/2011 and expiring on
01/11/2017.
5. Notice of Acceptance No. 15-1203.04, issued to Cellofoam North America hic, for
their. Expanded Polystyrene Block Insulation, approved on 03/17/2016 and
expiring on 02/24/2021.
"Submitted under NOA # 03-0228.02"
6. Test Report on Accelerated Weathering Using Xenon Arc Light Apparatus Test per
ASTM G155 of "PVC Extrusion Material", prepared by Hurricane Engineering &
Testing, Inc., Report No. IIETI 04-A002, dated 09/27/2004, signed and sewed by Rafael E.
Droz-Seda, P.E.
7. Test Reports on Tensile Test per ASTM D638 of "PVC Extrusion Material', prepared by
Hurricane Engineering & Testing Inc., Report No. HETI 04-T251, dated 11/29/2004 signed
and sealed by I. Ghia, P.E.
8. Test Report on Self -Ignition Temperature Test, Rate of Burn Test and Smoke Density
Test of "REHAU non -foam PVC extrusion material', prepared by ETC Laboratories,
Report No. 04-761-15019.0, dated 05/06/2004, signed and sealed by J. L. Doldan, P.E.
F. STATEMENTS
1. Statement letter of code conformance to the 5' edition (2014) FBC and of no financial interest
issued by AI-Farooq Corporation, dated 03/21/2016, signed and sealed by Javad Ahmad, P.E.
Ishaq L Chanda, P.E.
Product Control Examiner
NOA No. 17-1018.13
Expiration Date: Aueust 9, 2021
Approval Date: December 14, 2017
E -2
DAB Door Company, inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUB
2. New Evidence submitted.
A. DRAWINGS
1. Drawing No. 01-09 REV L, titled "Sectional Garage Door", sheets 1 through 5 of 5, dated
02/01/2001 and last revised on OCT 05, 2017, sheets 1 through 5 of 5, prepared by Al-
Farooq Corporation, signed and sealed by Javad Ahmad, P.E.
Note: This revision consist of editorial changes to comply with FBC 2017.
B. CALCULATIONS
1. None
C. QUALITY ASSURANCE
1. Miami Dade Department of Regulatory and Economic Resources (RER).
D. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 17-0221.06, issued to Insulfoam, LLC, for their
Insrufoam Expanded Polystyrene Insulation, expiring on 11/29/2022.
2. Notice of Acceptance No. 15-1108.04, issued to Dypiast Products, LLC, for their Dyplast
ISO -C1 Polyisocyanurate Insulation, expiring on 01/11/2022.
3. Notice of Acceptance No. 15-1203.04, issued to Cellofoam North America Inc, for their
Expanded Polystyrene Block Insulation, expiring on 02/24/2021.
4. Notice of Acceptance No. 15-0915.08, issued to SABIC Innovative Plastics, for their Lexan Sheet
Products, expiring on 07/17/2018.
E. STATEi4'IENTS
l . Statement letter of conformance to FBC 2014 (5'-b Edition) and FBG 2017 (6" Edition),,
prepared by Al Farooq Corporation, dated 10/05;17, signed and sealed by Javad Ahmad,
P.E.
F. OTHER
1. This NOA revises NOA # 16-0330.02, expiring 08/09/21.
Ishaq I. Chapala, P.E.
Product Control Examiner
NOA No. 17-101813
Expiration Date: Angust 9, 2021
Approval Date: December 14, 2017
E -3
DOOR HEIGHT
CONSISTS OF
6'-6"
2 SECTIONS 18" 2 SECTIONS 21"
6'-9"
1 SECTION 18" 3 SECTIONS 21"
7'
4 SECTIONS 21" -
7'-3"
-
7'-6"
5 SECTIONS 18" -
7'-9"
4 SECTIONS 18" 1 SECTION 21"
8'
3 SECTIONS 18" 2 SECTIONS 21"
8'-3"
2 SECTIONS 18" 3 SECTIONS 21"
8'-6"
1 SECTION 18" 4 SECTIONS 21"
8'-9"
5 SECTIONS 21" -
9'
6 SECTIONS 18" -
9'-3"
5 SECTIONS 18" 1 SECTION 21"
9'-6"
4 SECTIONS 18" 2 SECTIONS 21"
9'-9"
3 SECTIONS 18",3 SECTIONS 21"
10'
2 SECTIONS 18" 4 SECTIONS 21"
10'-3"
1 SECTION 18" 5 SECTIONS 21"
10'-6"
6 SECTIONS 21" -
10'-9"
6 SECTIONS 18" 1 SECTION 21"
11'
5 SECTIONS 18" 2 SECTIONS 21"
11'-3"
4 SECTIONS 18" 3 SECTIONS 21"
11'-6"
3 SECTIONS 18" 4 SECTIONS 21"
11'-9"
2 SECTIONS 18" 5 SECTIONS 21"
12'
1 SECTIONS 18" 6 SECTIONS 21"
12'-3"
7 SECTIONS 21" -
12'-6"
6 SECTIONS 18" 2 SECTIONS 21"
12'-9"
5 SECTIONS 18-13 SECTIONS 21-
13'
4 SECTIONS 18"14 SECTIONS 21"
13'-3"
3 SECTIONS 18" 5 SECTIONS 21"
13'-6"
2 SECTIONS 18" 6 SECTIONS 21"
13,-9"
1 SECTION 18" 7 SECTIONS 21"
14'
8 SECTIONS 21" -
14'-3"
6 SECTIONS 18" 3 SECTIONS 21"
14'-6"
5 SECTIONS 18" 4 SECTIONS 21"
14'-9"
4 SECTIONS 18" 5 SECTIONS 21"
15'
3 SECTIONS 18" 6 SECTIONS 21"
2 SECTIONS 18" 7 SECTIONS 21"
1 SECTION 18" 8 SECTIONS 21"
15'-9"
9 SECTIONS 21" -
16'
6 SECTIONS 18-J4 SECTIONS 21"
[y
7-1/2" X 3" X .071" GALV. STEEL
END ROLLER HINGE
W/ (6) #14 X 5/8" SMS
WITHOUT DELRON SLEEVE (STD.)
WITH DELRON SLEEVE (OPTIONAL)
p
7-1/2" X 2-1/4" X .071"
\\ p GALV. STEEL CENTER HINGE IF
\ W/ (4) #14 X 5/8" SMS
�\ WITH DELRON SLEEVE (OPTIONAL) B
\ LOCK
2/ DOOR
o \
j I 1" W X .15° THK. LATCH
I I I\
\ STANDARD LOCK
`\ SPRING LOADED SLIDE BOLT (BOTH SIDES) �.
\� FASTENED W/ (4) #14 X 1/2" S.M.S.
-- 5/8" MIN. LOCK ENGAGEMENT '
CONFORMS TO SECTION 1008 REGARDING GARAGE DOORS
.158 DIA. GALV. AIRCRAFT TYPE
CABLE & NICO -PRESS SLEEVE
W/ MIN. 5 TO 1 SAFETY FACTOR
6"X3"X0.1"
STEEL PLATE
WITH (2) #14 X 5/8" SMS
BRACKET BRACKET
STD. LIFT DOORLOW HEADROOM
DOOR OPTION
7-7/8" X 3-1/8" X .010"
STEEL PLATE
WITH (4) #14 X 3/4" SDS
STILE
J\I LOCK BAR GUIDES
`L INSTALLED ON END STILE
WITH (4) #14 X 5/8" SMS
.18T X .6W LOCK BAR
ENGAGES IN TRACK
ON EACH SIDE OF DOOR
OUTSIDE KEYED LOCK (OPTIONAL)
LOCK BAR LOCKING SHOWN
ALTERNATE TO SPRING LOADED SLIDE BOLT
LOCKS SHOWN ABOVE
TOP FIXTURE 5-1/2" X 2-3/4" X 0.1"
STEEL PLATE WITH ONE 5/16-18 MS W/ NUT
FASTENED TO END STILE WITH
(6) #14 X 3/4" SELF DRILLING SCREWS
CENTER STILE
OPTIONAL DOOR VIEWER
TO BE INSTALLED AT
CENTER STILE
r—A
1111 p I III////
D
4. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT
♦♦1`®
♦ �.
Ga°G�i /
o
�
I
FM-Nj
B
=
w
x
o °
a w_
� �i
I
'
REQUIREMENTS OF THE 2014/2017 FLORIDA BLDG. CODE &ADOPTED STANDARDS. _
1,1GBNSLF
In
z
5. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION
OPTIONAL DOOR VIEWER
TO BE INSTALLED AT
CENTER STILE
r—A
OPTIONAL VENT L — A
(3) 5 WIDE AT 7" O.C. MAX.
OPENING AREA NOT TO EXCEED
120 SQ. IN. COLONIAL DESIGN
MAX. DOOR WIDTH
9' -4 -
INSIDE ELEVATION
RAISED PANEL EMBOSSED DOOR
#14 X 3/4" SELF DRILLING SCREWS MAY BE USED
IN LIEU OF #14 X 5/8" SMS
GENERAL NOTES
1. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE
REQUIREMENTS OF THE 2014 (5TH EDITION)/2017 (6TH EDITION) FLORIDA
BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ).
2. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS
AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE
MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO.
OPTIONAL FLUSH FACE
WOOD GRAIN DESIGN
DAD DOORS INC.
Hurricane Master® Model 824/811
Max. Size 9'-4" X 16'-0" High
With Window Lite Option
DESIGN PRESSURE RATING = + 50.0 PSF
— 60.0 PSF
DOOR TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF FLORIDA
BUILDING CODE, TAS -202, TAS -201 & TAS -203 FOR HVHZ AND
ASTM E1886-05/ASTM E1996-09.
THIS PRODUCT IS RATED FOR LARGE MISSILEIMPACT
Z M r
OZ MN
QW
� z"
0 a n
-1
Cq
aN
0
(
/V p LU ri
v ¢Mm0
0 0.0cppi
0 Ny�m
O
aW�U�
1ZN -O
jz¢w
QwTEr
N
N
m
I
N
� M
OU D
O o
0 C O
Li — M
Q
Cf O Q
E
-1 00 o
Q U 0) 0O N
Z
O � �i o
UO Z O N
Lf)
p o
m rn 0 �
Q N = F
;V
-3. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY.
1111 p I III////
D
4. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT
♦♦1`®
♦ �.
Ga°G�i /
o
�
I
B
=
w
x
o °
a w_
� �i
I
'
REQUIREMENTS OF THE 2014/2017 FLORIDA BLDG. CODE &ADOPTED STANDARDS. _
1,1GBNSLF
In
z
5. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION
Y 592
°
O
0
° O
FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY
pReau,C fREV, _
'
O
p41-
U O
W
nO
OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR
6. 74e
vi
.
v
;
FOR CONNECTION OF WOOD BUCK
TO MASONRY SEE NOTE ON SHEET 4
SOUTHERN PINE
0.55 S.G. EDG DIST:.
1-3/16"
1.9" X 2.19" X 3.3" X .102"
STEEL TRACK BRACKETS
SEE SHEET 3 FOR SPACING
ffili'limSIIQ!
STEEL TRACK BRACKET FASTENED SOLID BRASS DOOR VIEWER
TO WOOD JAMB WITH BY 'SCHLAGE SECURITY HARDWARE'
5/16" X 1-5/8" LAG SCREW INSTALLED IN 9/16" DIA. HOLES IN CENTER STILE
(FULLY THREADED)
ONE PER BRACKET POSITIONED AT EYE LEVEL
OPTIONAL STOP MOULDING
BY DOOR INSTALLER
#14 X G SMS
HINGE
6 PER HING3/4" X 2" X 2-1/2" X 18 GA. STEEL
E END STILE, CONNECT TO PANELS WITH
1/2" X 1-3/4" X .059" FORMED STEEL FLAPS AND 3/16" ALUM RIVETS
GLUED TO PANEL AND SECURED TO SEE DETAIL ABOVE
END STILE WITH 3/16" POP RIVETS ® 12" O.C.
7/16" PUSHNUT
INSTALLED ON ROLLER SHAFT
STEEL TRACK
14 GA. X 2-1/8" X 1" (STANDARD)
12 GA. X 3-5/16" X 1-1/2" (OPTIONAL)
FASTENED TO TRACK PLATES
W/ 1/4-20 X 5/8" TRUSS HD.
SLOTTED M.S. & LOCK NUT
1-7/8" X 2-5/8" X .045" STEEL
CENTER STILE, GLUED AND RIVETED
TO PANEL W/ (4) 3/16" RIVETS
#14 X 5/8" S.M.S.
4/ HINGE
7-1/2" X .071" GALV. STEEL J
CENTER HINGE
SECTION B -B
INTERIOR SIDE
POP RIVETS
7-1/2" X 3" X .071
END ROLLER HINGE
24 GA. S
3/16" ALU
FLAPS BENT OVER PANEL
1/2" PUNCHED HOLES
0 4" O.C.
ANCHORS AT TRACK BRACKET:
A) 3/8" DIA, POWER—BOLT BY 'POWERS'
2" MIN. EMBED INTO CONCRETE
1-7/8" MIN. EDGE DISTANCE
B) 3/8" DIA. HLC SLEEVE BY 'HILTI'
1-1/4" MIN. EMBED INTO CONCRETE OR FILLED
1-5/8" MIN. EDGE DISTANCE INTO CONCRETE
4" MIN. EDGE DISTANCE INTO FILLED BLOCK
EDGE CONCRETE Vc = 3000 PSI MIN.
~DISTANCE C-90 GROUT FILLED BLOCK f'm = 2000 PSI MIN.
Ducf REV
theF
Amcom,e No t7^d6 `•62y
to 2
4
ANCHOR TYPE A OR B
(1) PER BRACKET
SEE SHEET 3 FOR BRACKET SPACING
1.82" DIA. X .50" STEEL ROLLERS (STD.)
1.82" DIA. X .50" NYLON ROLLERS (OPTIONAL)
2.75" DIA. X .50" STEEL ROLLERS (OPTIONAL)
2.75" DIA. X .50" NYLON ROLLERS (OPTIONAL)
WITH 5" STEM
1/4-20 SS BOLT & NUT
c.70592
_.° S ITE OF
�f
� 0
0
I
�m o
m
� H w
O Z M N
W
Q 2 . N 0
IL a
p ° �q a
wN
Lu
O�io1m
V ❑f cl
crSKM o
C d in aiapl
0 °� C
Nm
O
N
Q W LL N
3 Z 02 m
CI O Q w
Q wmi r
arowing no.
01-09
rn
I
N
�
M
O
O
U
0 o
w
_
j
7
Q
0_
Q Q
Ll
O
a
oz)
Q
0 a
N
z
O_
0 u^
0LLI z
0 N
N
0 to
0 O
m6°�
Q V
..
_ �2
D
arowing no.
01-09
2 X 2 X 1/8" HORIZ. ANGLE r' m
2" POP RIVETS 5/16" X 1-5/8" LAG SCREWS INTO WOOD OR HORIZ. TRACK SUPPORT, SPOT WELDED TO HORIZ. TRACK U
2-3/4" X 5-1/2" X 3" X .104" 5/16" SLEEVE ANCHORS CENTER SUPPORT READ. ON DOORS WITH TWO WELDS AT 1-1/2" APART rn
GALV. STEEL / o
TOP ROLLER BRACKET ON EACH SIDE WITH 1-1/4" EMBED INTO MASONRY EX�yEEDING 8 FT. IN HEIGHT FIRST AT 3" O.C.
3 PER BRACKET II A REST AT 9" O.C.
FASTENED W/ (6) # 14 X 5/8" S.M.S. _ _ o
CONNECTED TO FLAG BRACKET ANGLE
.090 THK. GALV. STEEL ADJUSTABLE W/ 3/8-16 X 3/4" BOLT & NUT C F M
SLIDE FASTENED TO BRACKET 2-1/2" X 4-1/4" X 13 GA. STEEL PLATES AND TO SPRING SHAFT GUIDE WITH 2 a
W/ 5/16-18 X 3/4" HEX HEAD _ _ WELDED TO 1-1/2" X 1-1/2" X 14 GA. ANGLE -- A J (2) 1/4-20 X 5/8" BOLT & NUT f W to <
M. SCREWS & NUTS. FASTENED TO TRACK - - a 2 � N 0
+ TOP BRACKET WITH (4) 1/4-20 SS. BOLT & NUTS - -- HORIZ. TRACK LENGTH = OPENING HEIGHT PLUS 12" O wW> N M
(STANDARD) a W cq
w
TOP BRACKET
LOW HEADROOMDOOR
VERTICAL TRACK w M
x 14 GA. GALV. STEEL TRACK 2-1/8" X 1" X .080" pri
N SECTION A—A C O— M o
w HORIZONTAL REINFORCEMENT C lY o
om x 1/2" X 1-3/4" X .059" FORMED STEEL 2" X 5-1/2" X .104" a p p ��Q
w GLUED TO PANEL AND FASTENED TO GALV. STEEL C P
o� d VERTICAL STILES WITH FASTENED W/ (4) # 14 X 5/8" S.M.S. O: C 100 OJ N
(2) 3/16" POP RIVETS TOP ROLLER BRACKET FOR Q w u ,�
LOW HEADROOM DOOR OPTION LuUO) - °m
HORIZONTAL REINFORCEMENT J Z (0 a w
1/2" X 1-3/4" X .059" FORMED STEEL Q w m i H
GLUED TO PANEL AND FASTENED TO
VERTICAL STILES WITH
(2) 3/16" POP RIVETS
5/16" MEETING RIB °J
N
F' *-SECTIONS ARE NUMBERED STARTING AT THE BOTTOM n
_ 1.82" DIA. X .50" ROLLERS x �- �
FOR DOORS MORE THAN 8 FT. HIGH, USE ADDITIONAL TRACK BRACKETS AT 10" O.C.
W/ .44 DIA. X 4-1/4" STEM w cxa O 00 o
U
z O DUC f B£Vi CD �; ai io
OPTIONAL INSULATIONS: a °� cumpiy%g with the Figs % < C Q
0 m 1.9" X 2.19" X 3.3" X .090" O L
BY 'DYPLAST PRODUCTS LLC' HSTEEL TRACK BRACKETS ng Gedt in-iQ t>`�A C¢.D p•L
i- ISO -25 POLY-ISOCYANURATE W w
2-3/16" HIGH Atct ance Na 00 m
DENSITY = 2.0 PCF m th wteT _ -T 0 0
N w N.O.A. #16-1108.04 CONNECTED TO TRACK WITH I y Z U N
0 = OR ) 1/4" BOLTS &NUTS. 1 iL• ' �t O
w BY 'CELLOFOAM NORTH AMERICA' m "et U O Z O N
m a DENSITY = 1.03 PCF LLI p t o
d N.O.A. #15-1203.04 u, m
OR N p]�-
BY 'INSULFOAM LLC' m Q N
DENSITY = 0.92 PCF _
N.OA. #17-0221.06 m O
M o
m w
O o
14 GA. GALV. STEEL. � a U
ROLLER HINGES FASTENED
W/ (4) #14 X 5/8" SMS m N E Q
O ¢
MIN. .024" ROLL FORMED STEEL PANEL 1 1
o z N o F
DRAWING QUALITY G-40 c z a
MIN. YIELD STRENGTH = 34 KSI o
WITH PRIMER AND BAKED -ON TRACK CONFIGURATION m o 0 o N a
POLYSTER PAINTED TOP COAT
F-
APPLIED TO BOTH SIDES OF STEEL
N W in < in m
o = VERTICAL LIFT HIGH LIFT STANDARD LIFT LOW HEADROOM .`4 0 o
w DOUBLE TRACK > =
o
a - AVAILABLE TRACK OPTIONS `0
12 GA. GALV. STEEL - XX`e®11111eBB/y®'®
BOTTOM BRACKET FASTENED
W/ (4) #14 X 5/8" SMS a ��.•° tc��s�.�� �A o 0
592
BOTTOM SEAL
O SEE SHEET 4 OPTIONS
O
®®'•. S4 OF �ryY� drawing no.
01-09
SECTION A—A
DOOR * SECTION HEIGHTS
BRACKET PLACEMENTS
HEIGHT 1ST
2ND
3RD 4TH 5TH
Bt 82 B3 B4
B5 B6
B7
BS
6'-0" 18"
18"
18" 18" N/A
1" TO 2" 11-3/4" 23" 34"
45" 56"
67"
—
6'-6" 21"
18"
18" 21" N/A
1" TO 2" 11-3/4" 23" 34"
45" 56"
67"
—
7'-O" 21"
21"
21" 21" N/A
1" TO 2" 11-3/4" 23" 34"
45" 56"
67"
-
7'-6" 18"
18"
18" 18" 18"
1" TO 2" 11_3/4" 23" 34"
45" 56"
67"
78_1/4'•
8'-0" 21"
18"
18" 18" 21"
1" TO 2" 11_3/4,• 23" 34"
45" 56"
67"
78_1/4„
F Z 1-1/2" MIN.
N
3N W
I
IA. LAG
WOOD BU I I —1/4"
FROM ENDS SCREWS WOOD
AND 19" O.C. MAX.
OPTION 'A'
OPTION 'B'
1/4" DIA. LAG SCREWS
AT 6" FROM ENDS
AND 19" O.C. MAX.
WOOD BUCK CONNECTION TO WOOD SUBSTRATE (WOOD SPECIFIC GRAVITY SG=0.55 MIN.)
THE INSTALLATION METHODS SHOWN ABOVE SHOWS 2X6 SYP WOOD BUCK ATTACHMENT
TO WOOD STRUCTURES. IF THESE METHODS ARE FOLLOWED NO ADDITIONAL CALCULATIONS/DESIGN
WILL BE REQUIRED FOR DESIGN OF GARAGE DOOR ANCHORAGE.
FOR DOOR REPLACEMENT APPLICATIONS WITH NO ENGINEER OF RECORD, INSTALLATION MAY BE
VERIFIED AND APPROVED BY THE BUILDING OFFICIAL UPON INSPECTION.
5/16" X 1-5/8"
LAG SCREWS
AT 12' O.C.
WOOD BUCK CONNECTION TO MASONRY
PRESSURE TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO
GROUTED REINFORCED MASONRY BLOCK WALL OR CONC. COLUMN WITH
1/4" ULTRACON BY 'ELCO' WITH SPACING OF
Id
16" O.C. INTO GROUT FILLED BLOCK WALL, WITH 2-1/4" MIN. EMBED
16" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED
STRUCTURE I
2-1/2" MIN. EDGE DISTANCE11-1/2"
SPACING
1/4" TAPPER BY 'POWERS' WITH SPACING OF
3/8" HLC SLEEVE BY 'HILTI'
14" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/2" MIN. EMBED
1-1/4"
16" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED
1/16" X 2-1/2'
3" MIN. EDGE DISTANCE
FILLET WELDS
3/8" CONFLEX BY 'ELCO' OR
AT 12" O.C. MAX.
3/8" LDT BY 'ITW' WITH SPACING OF
3Z8" DYNABOLT BY ',TW,
24" O.C. INTO 3000 PSI CONCRETE, WITH 2-1/2" MIN. EMBED
1-1/2"
2" MIN. EDGE DISTANCE
CONTINUOUS ANGLE TRACK
3/8" HLC SLEEVE BY HILTI' WITH SPACING OF
TO WOOD BUCK
8" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/4" MIN. EMBED, 4" MIN.
EDGE DIST.
18" O.C. INTO 3000 PSI CONCRETE, WITH 1-1/4" MIN. EMBED AND
3/8" POWER—BOLT BY 'POWERS'
2-1/2" MIN. EDGE DISTANCE
2"
PREPARATION OF JAMBS BY OTHERS
FOR NEW CONSTRUCTION ENGINEER OF RECORD OR ARCHITECT TO VERIFY
ADEQUACY OF SUPPORTING STRUCTURE TO SUPPORT LOADS IMPOSED
BY DOOR SYSTEM.
FOR DOOR REPLACEMENT IN RETROFIT BUILDINGS WITH NO ENGINEER OF
RECORD, DOOR INSTALLATION MAY BE REVIEWED AND APPROVED BY
BUILDING OFFICIAL UPON INSPECTION.
MAXIMUM EXTERIOR(+) LOAD PER JAMB = (9.33' X 50 PSF)/2 = 233.3 Lbs per Ft.
MAXIMUM INTERIOR(—) LOAD PER JAMB = (9.33' X 60 PSF)/2 = 279.9 Lbs per Ft.
#8X 1"
SELF DRILLING SCREWS
OR
3/16" 'RIVER' STEEL RIVETS
MULTIGRIP W/ DOME HEAD
AT 48" O.C.
REINFORCEMENT
1/2" X 1-3/4" X .058"
FORMED STEEL
W'STRIP
CEME
X 1-3/-3/NT
X 14 X .058"
.D STEEL
#8 X 1"
SELF DRILLING SCREWS
OR
3/16" 'RIVEX' STEEL RIVETS
MULTIGRIP W/ DOME HEAD
AT 48" O.C.
O
W'STRIP ADAPTER
STEEL
RUBBER W'STRIPPING--/ DRUBBER W'STRIPPING
050"��� ,040
.224 W IS J� .534 .700
.348
1.750 1.790 ! uDliCf RE6RSM
as a ptyiny with the Fkwkh
BOTTOM SEAL OPTIONS b0dinK Ctwk
Acceptance Nn )iy 0( I.("
ExpinWem Due
STEEL STRUCTURE BY OTHERS
MUST SUPPORT THE LOADS IMPOSED
BY DOOR SYSTEM
ANCHOR SPACING
ANCHORS
STRUCTURE I
EMBED
SPACING
EDGE DIST.
3/8" HLC SLEEVE BY 'HILTI'
CONC. 1
1-1/4"
8"
1 1-5/8"
3/8- HLC SLEEVE BY 'HILTI'
FILLED BLOCK
1-1 4"
8"
4"
3Z8" DYNABOLT BY ',TW,
CONC.
1-1/2"
8"
2"
3/8- DYNABOLT BY T'W'
FILLED BLOCK
1-1 2"
8"
2-1/4"
3/8" POWER—BOLT BY 'POWERS'
CONC.
2"
8"
1-7/8"
3/8" SLEEVE—ALL BY 'SIMPSONS'
CONC.
1-1/2"
8"
1-7/8"
CONCRETE Vc = 3000 PSI MIN.
5/16" DIA. BOLTS C-90 GROUT FILLED BLOCK f'm = 2000 PSI MIN.
WITH WASHER & NUT
AT 12" O.C. MAX. EDGE
I
— 1-1/4 X 2-1/2" X 14 GA
1-1/2" CONT. STEEL ANGLE 1 1-1/2"
12 GA. GALV. STEEL
FLAT BRACKETS t3" LONG
AT 12" O.C. IN DOOR OPNG.
AT 18" O.C. ABOVE DOOR OPNG.
CONNECTED TO CONT. ANGLE
W/ (3) SPOT WELDS AT EACH SIDE
REVERSE TRACK
TO STEEL
ALTERNATE TRACK INSTALLATION
1"X 14 GA.
CONTINUOUS ANGLE TRACK
TO CONCRETE AND FILLED BLOCK
tOX5/8°" TRUSS HD.
& LOCK NUT
Z co
t.m
ZM N
F W Z !D
Q E N
a B
0 C4
CUNT
v > m
�mm" o
pacoN
O (n UU)0 m
m z J N
i W a N
WU1 . 0
.1 ZMaw
Q W m r
INi �
0
w
Of
0_
0
J
Z
O
H
U
W
In
c
®�® °•, T OR �2�e
drawing no.
DOOR PANEL
24 GA. (.024) STEEL MIN.
7/16" DIA. WASHER
M ISI m
#8 X 3/4" SMS
0 3/8" FROM ENDS
AND 7" O.C. MAX.
7/16" DIA. WASHER
DOOR PANEL
24 GA. (.024) STEEL MIN.
#8 X 3/4" SMS
3/8" FROM ENDS
AND 4-1/2" O.C. MAX.
DOOR PANEL
24 GA. (.024) STEEL MIN.
* PLASTIC COMPLIES WITH
CHAPTER 26 OF FBC
SEE EVIDENCE PAGE
a
.500 250 a
o
1 I
o
m Q
n Qw
O Z M N K
r W Z N
7.765 1.725 dQ d Q
It ON 0
1.144 a cl
W
F0F.. F
0
L
I ci p>m
ns �.fio° 0 a o o
* EXTERIOR FRAME * INTERIOR FRAME
0
RIGID PVC ONE PIECE INJECTION RIGID PVC ONE PIECE INJECTIONQ w z LL N
LL z N - M
J�
CID Qj
Q LU
INSIDE ELEVATION
RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS
OWINDOW LITES CAN BE IN ANY LOCATION IN DOOR SECTION
.175 X .062 DEEP
GROOVE I
6" MIN.
WINDOW WIDTH
EXTERIOR
D.L. OPG.
P'RODUC f REVISED
m camplylog with the
budding Cuda
Aaeptmce No 117-16
r ate
R
e ri
0 0
o = o
j N H
70592 e s a
d s
D
UE OF =1�Zp drawing no.
01-09
#8 X 3/4" SMS
I 0 3/8" FROM ENDS
II
O
11
I:
III ! II AND Y' O.C. MAX.
I.
I
LII I (4) #8 X 3/4" SMS
@ 1-3/8" FROM ENDS
III! I N AND 6-1/2" O.C. MAX.
1
L
I 1 I
jli i
IIII
IIII .175 X .062 DEEP
GROOVE
I'I
Ijll
IIII
I!I! 1/4" POLYCARBONATE LEXAN
BY 'SABIC INNOVATIVE PLASTICS'
NOA #15-0915.08
of
O
a
O Ld
w
0Ld
I
I j l i
IIII
IIII
ISI!
III II
IIII
IIII
Ii
Ij li .175 X .062 DEEP
GROOVE
(4) #8 X 3/4" SMS
_----AND 6-1/2" D.C. MAX.
M ISI m
#8 X 3/4" SMS
0 3/8" FROM ENDS
AND 7" O.C. MAX.
7/16" DIA. WASHER
DOOR PANEL
24 GA. (.024) STEEL MIN.
#8 X 3/4" SMS
3/8" FROM ENDS
AND 4-1/2" O.C. MAX.
DOOR PANEL
24 GA. (.024) STEEL MIN.
* PLASTIC COMPLIES WITH
CHAPTER 26 OF FBC
SEE EVIDENCE PAGE
a
.500 250 a
o
1 I
o
m Q
n Qw
O Z M N K
r W Z N
7.765 1.725 dQ d Q
It ON 0
1.144 a cl
W
F0F.. F
0
L
I ci p>m
ns �.fio° 0 a o o
* EXTERIOR FRAME * INTERIOR FRAME
0
RIGID PVC ONE PIECE INJECTION RIGID PVC ONE PIECE INJECTIONQ w z LL N
LL z N - M
J�
CID Qj
Q LU
INSIDE ELEVATION
RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS
OWINDOW LITES CAN BE IN ANY LOCATION IN DOOR SECTION
.175 X .062 DEEP
GROOVE I
6" MIN.
WINDOW WIDTH
EXTERIOR
D.L. OPG.
P'RODUC f REVISED
m camplylog with the
budding Cuda
Aaeptmce No 117-16
r ate
R
e ri
0 0
o = o
j N H
70592 e s a
d s
D
UE OF =1�Zp drawing no.
01-09