HomeMy WebLinkAboutProduct Approval-FL1654_R22_2017 Building Code EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 Christian Street
Oxford, CT 06478
(203) 262-9245
EVALUATION REPORT
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 89408
(570) 384-1230
Evaluation Report P9290.02.08-R20
FL1654-R22
Date of Issuance: 02/11/2008
Revision 20: 09/12/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 6th Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity|ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words “Trinity | ERD Evaluated” may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6, plus a 58-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 09/12/2017. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity | ERD does not have, nor does it intend to acquire or will it acquire, a financial interest
in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity | ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval proc ess of the
product.
5. This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
Exterior Research and Design, LLC. Evaluation Report P9290.02.08-R20
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-R22
Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017
Page 2 of 6
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Modified Bitumen Roof Systems
Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems, as produced by Polyglass USA,
Inc., have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind FM 4474 2011
1504.3.1 Wind UL 1897 2012
1504.7 Impact FM 4470 2012
1507.11.2 Physical Properties ASTM D6162 2008
1507.11.2 Physical Properties ASTM D6163 2008
1507.11.2 Physical Properties ASTM D6164 2011
1507.11.2 Physical Properties ASTM D6222 2011
1507.11.2 Physical Properties ASTM D6509 2009
3. REFERENCES:
Entity Examination Reference Date
ERD (TST6049) Physical Properties P10490.10.08-2 10/30/2008
ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009
ERD (TST6049) FM 4470/4474 P13770.09.09 09/10/2009
ERD (TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009
ERD (TST6049) FM 4470/4474 P30550.12.09 12/02/2009
ERD (TST6049) Physical Properties P33960.12.10 12/30/2010
ERD (TST6049) FM 4470/4474 P33970.03.11 03/15/2011
ERD (TST6049) Physical Properties P37590.03.13-3A 03/06/2013
ERD (TST6049) FM 4470/4474 P39680.03.13 03/04/2013
ERD (TST6049) Physical Properties P37590.03.13-1-R1 06/26/2013
ERD (TST6049) Physical Properties P37590.03.13-2-R1 07/01/2013
ERD (TST6049) Physical Properties P37590.07.13-2 07/01/2013
ERD (TST6049) Physical Properties P37590.03.13-5-R1 07/01/2013
ERD (TST6049) Physical Properties P37590.07.13-1 07/02/2013
ERD (TST6049) FM 4470/4474 P41630.08.13 08/06/2013
ERD (TST6049) Physical Properties P45940.09.13 09/04/2013
ERD (TST6049) Physical Properties P44370.10.13 10/04/2013
ERD (TST6049) Physical Properties P39520.09.14-2 09/11/2014
ERD (TST6049) FM 4470/4474 SC6160.11.14 11/10/2014
ERD (TST6049) Physical Properties PLYG-P45440SC.03.15-1 03/31/2015
ERD (TST6049) Physical Properties SC5170.05.15 05/08/2015
ERD (TST6049) FM 4474 SC8085.05.15 05/19/2015
ERD (TST6049) Physical Properties SC5170.12.15 12/29/2015
ERD (TST6049) FM 4470/4474 SC9455.15 04/01/2016
ERD (TST6049) FM 4470/4474 PLYG-SC8905.05.16-1 05/17/2016
ERD (TST6049) FM 4470/4474 PLYG-SC8905.05.16-2 05/17/2016
ERD (TST6049) FM 4470/4474 PLYG-SC10815.07.16-R1 09/23/2016
ERD (TST6049) UL 1897 PLYG-SC12025.10.16 10/12/2016
ERD (TST6049) FM 4470/4474 PLYG-SC11475.16 11/17/2016
ERD (TST6049) FM 4470/4474/UL1897 PLYG-SC13235.01.17 01/17/2017
ERD (TST6049) FM 4474/UL1897/TAS 114 PLYG-SC13920.05.17 05/30/2017
ERD (TST11294) FM 4474/UL1897/TAS 114 PLYG-CTL13945.05.17-1 05/30/2017
Exterior Research and Design, LLC. Evaluation Report P9290.02.08-R20
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-R22
Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017
Page 3 of 6
Entity Examination Reference Date
ERD (TST11294) FM 4474/UL1897/TAS 114 PLYG-CTL13945.05.17-3 05/30/2017
ERD (TST6049) FM 4474/UL1897 PLYG-SC13945.05.17 05/30/2017
ERD (TST6049) FM 4474/TAS 114 PLYG-SC15760.09.17 09/11/2017
FM Approvals (TST1867) FM 4470 2W7A7.AM 08/04/1994
FM Approvals (TST1867) FM 4470 0D3A3.AM 04/04/1997
FM Approvals (TST1867) FM 4470 2D0A0.AM 12/23/1998
FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999
FM Approvals (TST1867) FM 4470 3006646 01/04/2000
FM Approvals (TST1867) FM 4470 3001334 01/25/2000
FM Approvals (TST1867) FM 4470 3001334 02/15/2000
FM Approvals (TST1867) FM 4470 3000857 01/12/2000
FM Approvals (TST1867) FM 4470 3004091 01/12/2000
FM Approvals (TST1867) FM 4470 3006115 05/02/2001
FM Approvals (TST1867) FM 4470 3012321 07/29/2002
FM Approvals (TST1867) FM 4470 3014692 08/05/2003
FM Approvals (TST1867) FM 4470 3014751 08/27/2003
FM Approvals (TST1867) FM 4470 3007170 01/13/2004
FM Approvals (TST1867) FM 4470 3019317 06/30/2004
FM Approvals (TST1867) FM 4470 3020703 07/30/2004
FM Approvals (TST1867) FM 4470/4474 3018332 01/31/2006
FM Approvals (TST1867) FM 4470/4474 3023368 03/20/2006
FM Approvals (TST1867) FM 4470/4474 3024594 05/23/2006
FM Approvals (TST1867) FM 4470/4474 3023458 07/18/2006
FM Approvals (TST1867) FM 4470/4474 3030668 09/12/2007
FM Approvals (TST1867) FM 4470/4474 3032172 06/12/2009
FM Approvals (TST1867) FM 4470/4474 3049631 04/21/2014
FM Approvals (TST1867) FM 4470/4474 3057029 02/02/2017
PRI (TST5878) Physical Properties PUSA-062-02-01 12/04/2007
PRI (TST5878) Physical Properties PUSA-061-02-02 01/28/2008
PRI (TST5878) Physical Properties PUSA-064-02-02 02/27/2008
PRI (TST5878) Physical Properties PUSA-062-02-02 12/04/2008
PRI (TST5878) TAS 114 PUSA-188-02-01 02/08/2017
PRI (TST5878) TAS 114 PUSA-188-02-02 02/08/2017
PRI (TST5878) TAS 114 PUSA-188-02-03 02/08/2017
PRI (TST5878) TAS 114 PUSA-202-02-01 05/17/2017
PRI (TST5878) TAS 114 PUSA-202-02-02 05/17/2017
Miami-Dade (CER1592) HVHZ Compliance Various NOAs Various
Miami-Dade (CER1592) Proposal for Review 10-0823 10/12/2010
UL LLC (QUA9625) Quality Control Service Confirmation, R14571 Exp. 10/06/2018
4. PRODUCT DESCRIPTION:
This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA,
Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass
membranes make up the subject systems.
TABLE 1: ROLL-GOODS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS
Type Product Specification
Reference Grade Type
Base Sheets
Polyglass G2 Base ASTM D4601 N/A II
Polyflex SA Base ASTM D4601 N/A II
Polyglass APP Base ASTM D6509 N/A N/A
Exterior Research and Design, LLC. Evaluation Report P9290.02.08-R20
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-R22
Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017
Page 4 of 6
TABLE 1 (CONTINUED): ROLL-GOODS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS
Type Product Specification
Reference Grade Type
SBS Membranes
Polyglass HT Base 650 ASTM D6162 S III
Elastobase ASTM D6163 S I
Elastoflex V ASTM D6163 S I
Elastoflex SA V Base ASTM D6163, Table 2 S I
Elastoflex SA V FR Base ASTM D6163, Table 2 S I
Elastoflex SA V Plus ASTM D6163 S I
Elastoflex SA V Plus FR ASTM D6163 S I
Elastobase Poly ASTM D6164 S I
Elastoflex S6 ASTM D6164 S I
Elastoflex S6 Type II ASTM D6164 S II
Elastoflex VG ASTM D6163 G I
Elastoflex VG FR ASTM D6163 G I
SBS Membranes
Elastoflex S6 G ASTM D6164 G I
Elastoflex S6 G FR ASTM D6164 G I
Polyfresko G SBS (sand or poly-film backed) ASTM D6164 G I
Polyfresko G SBS FR (sand or poly-film backed) ASTM D6164 G I
Elastoshield TS G ASTM D6164 G I
Elastoshield TS G FR ASTM D6164 G I
Elastoflex SA P ASTM D6164 G I
Elastoflex SA P FR ASTM D6164 G I
Polyreflect ASTM D6164 S I
APP Membranes
Polyflex ASTM D6222 S I
Polyflex G ASTM D6222 G I
Polyflex G FR ASTM D6222 G I
Polyfresko G ASTM D6222 G I
Polyfresko G FR ASTM D6222 G I
Polybond ASTM D6222 S I
Polybond G ASTM D6222 G I
Polyflex SA P ASTM D6222 G I
Polyflex SA P FR ASTM D6222 G I
Polyfresko G SA ASTM D6222 G I
Polykool ASTM D6222 S I
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product.
5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance
with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply.
5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural
members shall be in accordance with FBC requirements to the satisfaction of the Authority Having
Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511.
Exterior Research and Design, LLC. Evaluation Report P9290.02.08-R20
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-R22
Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017
Page 5 of 6
5.7 For mechanically attached insulation or membrane or strip-bonded insulation, the maximum design pressure
for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with
FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design
professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS
137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected
assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No
rational analysis is permitted for these systems.
5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the
existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison
to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI
FX-1 or Testing Application Standard TAS 105.
5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the
existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If
any surface conditions exist that bring system performance into question, field uplift testing in accordance
with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS
124 shall be conducted on mock-ups of the proposed new roof assembly.
5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof
system shall be capable of resisting project design pressures on its own merit to the satisfaction of the
Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM
Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with
FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard
RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or
1609.3(3).
5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3.
6. INSTALLATION:
6.1 Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA, Inc. published
installation instructions, subject to the Limitations / Conditions of Use noted herein.
6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. ”MDP” = Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects
the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been
applied). Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, LLC. Evaluation Report P9290.02.08-R20
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-R22
Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017
Page 6 of 6
6.3 Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect
on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated
with coating usage.
PG200 Non-Fibered Roof Coating;
PG300 Fibered Roof Coating;
PG600 Non-Fibered Aluminum Roof Coating;
PG650 Fibered Aluminum Roof Coating;
PG700 High Quality Elastomeric Roof Coating or KM Acryl 25;
PG700QS (Quick-Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (over granule-surfaced
APP or SBS only);
PG800 Asphalt Emulsion Roof Coating;
Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
Polyplus 65 Premium Fibered Aluminum Roof Coating;
Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15;
Polybrite 70QS (Quick-Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (over granule-
surfaced APP or SBS only);
Polybrite 90 High Solids Silicone Roof Coating;
Polybrite 95 Silicone Roof Coating.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA
requirements
9. QUALITY ASSURANCE ENTITY:
UL LLC – QUA9625; (314) 578-3406, k.chancellor@us.ul.com
- THE 58-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT -
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 1 of 58
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table Deck Application Type Description Page
1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 5
1B-1 Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9
1B-2 Wood New, Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-11
1C Wood New, Reroof (Tear-Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 11
1D Wood New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 12-13
1E Wood New, Reroof (Tear-Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14-15
1F-1 Wood New or Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 16-18
1F-2 Wood New, Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 19-21
1G Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 21
2A Steel or Structural concrete New, Reroof (Tear-Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22-24
2B Steel or Structural concrete New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 25-28
2C Steel or Structural concrete New, Reroof (Tear-Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 29-31
3A Structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 32-40
3B Structural concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 40
4A LWIC New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 41-42
4B LWIC New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 43
4C LWIC New or Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 44-46
5A CWF New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 47
5B CWF New, Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 48
5C CWF New, Reroof (Tear-Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 49
5D CWF New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 49
5E CWF New, Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 49
6A Gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 50-52
6B Gypsum Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 52
6C Gypsum Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 53
6D Gypsum Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 53
7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 54-58
7B Various Recover F Non-Insulated, Bonded Base Sheet, Bonded Roof Cover 58
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
Wood: Minimum 0.75-inch penetration.
Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer’s published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral-wool roof board that meets the QA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 2 of 58
4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically atta ched base sheet, bonded roof cover), whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions.
Hot asphalt (HA): Full coverage at 25-30 lbs/square.
Dow INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.
Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
Millennium PG-1 Pump Grade Adhesive (M-PG1): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced.
OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c.
Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered.
Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick)
Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP -157.5 psf (Min. 0.5-inch thick)
OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi-Max FA-3)
OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL)
OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3)
OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II)
ICP Adhesives & Sealants CR-20: MDP -117.5 psf (Min. 1.0-inch thick)
8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches.
For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 3 of 58
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
TABLE 1: POLYGLASS ROOF COVERS
Reference Layer Material Application
BP-AA
(Base and Ply sheets, Asphalt-
Applied)
Base Ply One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II Hot Asphalt at 20-40
lbs/square Ply One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
Note: Asphalt-applied sheets or insulation shall not be applied to poly-film surfaced membranes.
SBS-CA1
Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 Type II, Polyglass HT Base 650 PG350 at 1.5-2.0
gal/square Cap Ply Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield
TS-G FR, Polyfresko G SBS (sand-backed), Polyfresko G SBS FR (sand-backed)
SBS-CA2
Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 Type II Polyplus 35 at 1.5-2.0
gal/square Cap Ply Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield
TS-G FR, Polyfresko G SBS (sand-backed), Polyfresko G SBS FR (sand-backed)
SBS-AA
(SBS, Asphalt-Applied)
Base Ply or Ply One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex
S6 Type II, Polyglass HT Base 650 Hot Asphalt at 20-40
lbs/square Cap Ply Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G,
Elastoshield TS-G FR, Polyfresko G SBS (sand-backed), Polyfresko G SBS FR (sand-backed)
Note: Asphalt-applied sheets or insulation shall not be applied to poly-film surfaced membranes.
SBS-TA
(SBS, Torch-Applied)
Base Ply or Ply One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 Type II, Polyglass HT Base
650 Torch-Applied
Cap Ply Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G,
Elastoshield TS-G FR, Polyfresko G SBS (poly-film backed), Polyfresko G SBS FR (poly-film backed)
SBS-SA
(SBS, Self-Adhering)
Base Ply One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR
Self-Adhering Cap Ply Elastoflex SA P, Elastoflex SA P FR, Polyreflect
Note: Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein,
Elastobase (poly/sand) or Elastobase (poly/poly).
APP-CA1 Cap Ply Polyflex G FR PG350 at 1.5-2.0
gal/square
APP-TA
(APP, Torch-Applied)
Base Ply or Ply One or more plies Polyglass APP Base, Polyflex, Polybond Torch-Applied Cap Ply Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR
APP-SA
(APP, Self-Adhering)
Cap Ply Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool
Self-Adhering Note: Unless otherwise noted, permissible membrane substrates for APP-SA are limited to the SBS-SA Base Ply options herein,
Elastobase (poly/sand) or Elastobase (poly/poly).
16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings
associated with coating usage.
PG200 Non Fibered Roof Coating;
PG300 Fibered Roof Coating;
PG600 Non-Fibered Aluminum Roof Coating;
PG650 Fibered Aluminum Roof Coating;
PG700 High Quality Elastomeric Roof Coating or KM Acryl 25;
PG700QS (Quick Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (for granule-surfaced APP or SBS only);
PG800 Asphalt Emulsion Roof Coating;
Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
Polyplus 65 Premium Fibered Aluminum Roof Coating;
Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15;
Polybrite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (for granule-surfaced APP or SBS only);
Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 4 of 58
17. Dens Deck shall be field-primed with PG100 prior to self-adhering membrane application. Refer to tables herein for other priming requirements.
18. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A
applies:
VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; ADHERED INSULATION PER TABLE 3A
Option # Primer Vapor Barrier Insulation Adhesive MDP (psf) Type Attach
VB-1. PG100 Elastoflex SA V Plus Self-Adhering Inta-Stik or CR-20, 12-inch o.c. -60.0
VB-2. PG100 Polyglass APP Base Torch-applied Inta-Stik or CR-20, 12-inch o.c. -75.0
VB-3. PG100 Elastoflex SA P Self-Adhering Insta-Stik, 12-inch o.c. -75.0
VB-4. PG100 Elastoflex SA P Self-Adhering Millennium One Step Foamable Adhesive, 12-inch o.c. -157.5
VB-5. PG100 Elastoflex SA P Self-Adhering CR-20, 12-inch o.c. -270.0
VB-6. PG100 Elastoflex SA V Base, Elastoflex SA V FR Base,
Elastoflex SA V Plus, Elastoflex SA V Plus FR Self-Adhering Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20, 12-inch o.c. -290.0
19. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 5 of 58
TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
SELF-ADHERING BASE PLY:
W-1 Min. 15/32-
inch plywood
Min. 1.5-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, ENRGY-3, Polytherm H, H-Shield, H-
Shield CG, Multi-Max FA3
D-IS, M-OSFA,
OB500 or CR-20
(Optional) additional
layers(s) of base insulation
D-IS, M-OSFA,
OB500 or CR-20 SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -52.5
W-2 Min. 15/32-
inch plywood
Min. 1.5-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, ENRGY-3, Polytherm H, H-Shield, H-
Shield CG, Multi-Max FA3
D-IS, M-OSFA,
OB500 or CR-20
(Optional) additional
layers(s) of base insulation
D-IS, M-OSFA,
OB500 or CR-20
Polyflex SA
Base (Optional) APP-TA APP-TA -52.5
TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Type Attach Base
Ply Ply Cap Ply
ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY:
W-3
Min.
15/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap
9-inch o.c. at 2-inch
lap and 18-inch o.c.
in two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.75-inch Fesco
Board (homogeneous) or
min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation
Hot
asphalt
BP-AA
or SBS-
AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
W-4
Min.
15/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap
9-inch o.c. at 2-inch
lap and 18-inch o.c.
in two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
W-5
Min.
15/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap
9-inch o.c. at 2-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.75-inch Fesco
Board (homogeneous) or
min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation
Hot
asphalt
BP-AA
or SBS-
AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA,
APP-TA
-52.5
W-6
Min.
15/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap
9-inch o.c. at 2-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 6 of 58
TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Type Attach Base
Ply Ply Cap Ply
W-7
Min.
19/32-inch
plywood
Polyglass G2 Base,
Elastobase,
Elastobase P
(sanded-top),
CertainTeed
Glasbase, Firestone
MB Base, JM Perma-
Ply 28, Tamko Glass
Base or GAFGLAS #75
32 ga., 1-5/8-
inch diameter
tin caps with
11 ga. annular
ring shank nails
8-inch o.c. in 4-inch
lap and 8-inch o.c. in
three (3), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
Polytherm G, ACFoam
III, ENRGY-3, Polytherm
H, H-Shield, H-Shield
CG, Multi-Max FA3
Hot asphalt
Min. 0.75-inch Fesco
Board (homogeneous) or
min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation
Hot
asphalt
BP-AA
or SBS-
AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA,
APP-TA
-60.0
W-8
Min.
19/32-inch
plywood
Polyglass G2 Base,
Elastobase,
Elastobase P
(sanded-top),
CertainTeed
Glasbase, Firestone
MB Base, JM Perma-
Ply 28, Tamko Glass
Base or GAFGLAS #75
32 ga., 1-5/8-
inch diameter
tin caps with
11 ga. annular
ring shank nails
8-inch o.c. in 4-inch
lap and 8-inch o.c. in
three (3), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
Polytherm G, ACFoam
III, ENRGY-3, Polytherm
H, H-Shield, H-Shield
CG, Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
W-9
Min.
19/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap Fasteners
12-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.75-inch Fesco
Board (homogeneous) or
min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation
Hot
asphalt
BP-AA
or SBS-
AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA,
APP-TA
-60.0
W-10
Min.
19/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap Fasteners
12-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
W-11
Min.
15/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
32 ga., 1-5/8-
inch diameter
tin caps with
12 ga. annular
ring shank nails
8-inch o.c. in 4-inch
lap and 8-inch o.c. in
four (4), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-67.5
W-12
Min.
15/32-inch
plywood
Polyglass G2 Base Simplex MAXX
Cap
9-inch o.c. in 4-inch
lap and 9-inch o.c. in
four (4), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-82.5
W-13
Min.
15/32-inch
plywood
Polyglass G2 Base,
Elastobase,
Elastobase P
(sanded-top)
32 ga., 1-5/8-
inch diameter
tin caps with
12 ga. annular
ring shank nails
6-inch o.c. in 4-inch
lap and 6-inch o.c. in
five (5) equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-90.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 7 of 58
TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Type Attach Base
Ply Ply Cap Ply
W-14
Min.
15/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap
6-inch o.c. at 2-inch
lap and 6-inch o.c. in
two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-90.0
W-15
Min.
19/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
32 ga., 1-5/8-
inch diameter
tin caps with
12 ga. annular
ring shank nails
6-inch o.c. in 4-inch
lap and 6-inch o.c. in
four (4), equally
spaced, staggered
center rows
Min. 2-inch Polytherm,
ACFoam II, III,
Polytherm H, H-Shield,
H-Shield CG, Multi-Max
FA3 or ENRGY-3
D-IS, OB500,
CR-20 or M-
OSFA, atop
fastener rows,
7-inch o.c.
Min. 0.25-inch Dens
Deck, Dens Deck Prime or
SECUROCK Gypsum-Fiber
Roof Board
D-IS,
OB500,
CR-20 or
M-OSFA
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0*
SELF-ADHERING BASE PLY:
W-16
Min.
15/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap
9-inch o.c. at 2-inch
lap and 18-inch o.c.
in two, equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber
Roof Board
Hot
asphalt SBS-SA
(Optional)
SBS-SA, SBS-
TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-45.0*
W-17
Min.
15/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap
9-inch o.c. at 2-inch
lap and 18-inch o.c.
in two, equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber
Roof Board
Hot
asphalt
Polyflex
SA Base
(Optional)
APP-TA APP-TA -45.0*
W-18
Min.
15/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap
9-inch o.c. at 2-inch
lap and 12-inch o.c.
in two, equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber
Roof Board
Hot
asphalt SBS-SA
(Optional)
SBS-SA, SBS-
TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-52.5
W-19
Min.
15/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap
9-inch o.c. at 2-inch
lap and 12-inch o.c.
in two, equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber
Roof Board
Hot
asphalt
Polyflex
SA Base
(Optional)
APP-TA APP-TA -52.5
W-20
Min.
19/32-inch
plywood
Polyglass G2 Base,
Elastobase,
Elastobase P
(sanded-top),
CertainTeed
Glasbase, Firestone
MB Base, JM Perma-
Ply 28, Tamko Glass
Base or GAFGLAS #75
32 ga., 1-5/8-
inch diameter
tin caps with
11 ga. annular
ring shank nails
8-inch o.c. in 4-inch
lap and 8-inch o.c. in
three (3), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
Polytherm G, ACFoam
III, ENRGY-3, Polytherm
H, H-Shield, H-Shield
CG, Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber
Roof Board
Hot
asphalt SBS-SA
(Optional)
SBS-SA, SBS-
TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-60.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 8 of 58
TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Type Attach Base
Ply Ply Cap Ply
W-21
Min.
19/32-inch
plywood
Polyglass G2 Base,
Elastobase,
Elastobase P
(sanded-top),
CertainTeed
Glasbase, Firestone
MB Base, JM Perma-
Ply 28, Tamko Glass
Base or GAFGLAS #75
32 ga., 1-5/8-
inch diameter
tin caps with
11 ga. annular
ring shank nails
8-inch o.c. in 4-inch
lap and 8-inch o.c. in
three (3), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
Polytherm G, ACFoam
III, ENRGY-3, Polytherm
H, H-Shield, H-Shield
CG, Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber
Roof Board
Hot
asphalt
Polyflex
SA Base
(Optional)
APP-TA APP-TA -60.0
W-22
Min.
19/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap Fasteners
12-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber
Roof Board
Hot
asphalt SBS-SA
(Optional)
SBS-SA, SBS-
TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-60.0
W-23
Min.
19/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap Fasteners
12-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber
Roof Board
Hot
asphalt
Polyflex
SA Base
(Optional)
APP-TA APP-TA -60.0
W-24
Min.
15/32-inch
plywood
Polyglass G2 Base,
Elastobase,
Elastobase P
(sanded-top)
32 ga., 1-5/8-
inch diameter
tin caps with
12 ga. annular
ring shank nails
8-inch o.c. in 4-inch
lap and 8-inch o.c. in
four (4), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
Polyflex
SA Base
(Optional)
APP-TA APP-TA -67.5
W-25
Min.
15/32-inch
plywood
Polyglass G2 Base Simplex MAXX
Cap
9-inch o.c. in 4-inch
lap and 9-inch o.c. in
four (4), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
Polyflex
SA Base
(Optional)
APP-TA APP-TA -82.5
W-26
Min.
15/32-inch
plywood
Polyglass G2 Base,
Elastobase,
Elastobase P
(sanded-top)
32 ga., 1-5/8-
inch diameter
tin caps with
12 ga. annular
ring shank nails
6-inch o.c. in 4-inch
lap and 6-inch o.c. in
five (5) equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
Polyflex
SA Base
(Optional)
APP-TA APP-TA -90.0
W-27
Min.
15/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
Simplex MAXX
Cap
6-inch o.c. at 2-inch
lap and 6-inch o.c. in
two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
Polyflex
SA Base
(Optional)
APP-TA APP-TA -90.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 9 of 58
TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Type Attach Base
Ply Ply Cap Ply
W-28
Min.
19/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
32 ga., 1-5/8-
inch diameter
tin caps with
12 ga. annular
ring shank nails
6-inch o.c. in 4-inch
lap and 6-inch o.c. in
four (4), equally
spaced, staggered
center rows
Min. 2-inch Polytherm,
ACFoam II, III,
Polytherm H, H-Shield,
H-Shield CG, Multi-Max
FA3 or ENRGY-3
D-IS, OB500,
CR-20 or M-
OSFA, atop
fastener rows,
7-inch o.c.
(Optional) Additional
layers of base insulation
D-IS,
OB500,
CR-20 or
M-OSFA
SBS-SA
(Optional)
SBS-SA, SBS-
TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-60.0*
W-29
Min.
19/32-inch
plywood
Elastobase,
Elastobase P
(sanded-top)
32 ga., 1-5/8-
inch diameter
tin caps with
12 ga. annular
ring shank nails
6-inch o.c. in 4-inch
lap and 6-inch o.c. in
four (4), equally
spaced, staggered
center rows
Min. 2-inch Polytherm,
ACFoam II, III,
Polytherm H, H-Shield,
H-Shield CG, Multi-Max
FA3 or ENRGY-3
D-IS, OB500,
CR-20 or M-
OSFA, atop
fastener rows,
7-inch o.c.
(Optional) Additional
layers of base insulation
D-IS,
OB500,
CR-20 or
M-OSFA
Polyflex
SA Base
(Optional)
APP-TA APP-TA -60.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 10 of 58
TABLE 1B-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap Ply
ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY:
W-30
Min. 15/32-
inch
plywood
Polyglass G2
Base,
Elastobase,
Elastobase P
(sanded-top)
Dekfast Hex (aka, Dekfast
PLT-H-2-7/8) with Dekfast
#14, OMG 3” Round Metal
Plate with OMG HD, OMG
Flat Bottom Plate (Accutrac)
with Roofgrip #14 or Trufast
3” Metal Insulation Plate
with Trufast HD.
10-inch o.c. in 4-inch
lap and 10-inch o.c.
in three (3), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot
asphalt
Min. 0.25-inch Dens
Deck, Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof
Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
W-31
Min. 19/32-
inch
plywood
Elastobase,
Elastobase P
(sanded-top)
OMG Flat Bottom Plates
(square) with Roofgrip #12
12-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot
asphalt
Min. 0.75-inch Fesco
Board (homogeneous)
or min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation
Hot
asphalt
BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA,
APP-TA
-60.0
W-32
Min. 19/32-
inch
plywood
Elastobase,
Elastobase P
(sanded-top)
OMG Flat Bottom Plates
(square) with Roofgrip #12
12-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot
asphalt
Min. 0.25-inch Dens
Deck, Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof
Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
W-33
Min. 15/32-
inch
plywood
Polyglass G2
Base,
Elastobase,
Elastobase P
(sanded-top)
Dekfast Hex (aka, Dekfast
PLT-H-2-7/8) with Dekfast
#14, OMG 3” Round Metal
Plate with OMG HD, OMG
Flat Bottom Plate (Accutrac)
with Roofgrip #14 or Trufast
3” Metal Insulation Plate
with Trufast HD.
9-inch o.c. in 4-inch
lap and 9-inch o.c. in
four (4), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot
asphalt
Min. 0.25-inch Dens
Deck, Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof
Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-82.5
SELF-ADHERING BASE PLY:
W-34
Min. 15/32-
inch
plywood
Polyglass G2
Base,
Elastobase,
Elastobase P
(sanded-top)
Dekfast Hex (aka, Dekfast
PLT-H-2-7/8) with Dekfast
#14, OMG 3” Round Metal
Plate with OMG HD, OMG
Flat Bottom Plate (Accutrac)
with Roofgrip #14 or Trufast
3” Metal Insulation Plate
with Trufast HD.
10-inch o.c. in 4-inch
lap and 10-inch o.c.
in three (3), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot
asphalt
Min. 0.25-inch Dens
Deck, Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof
Board
Hot
asphalt
Polyflex SA
Base
(Optional)
APP-TA APP-TA -52.5
W-35
Min. 19/32-
inch
plywood
Elastobase,
Elastobase P
(sanded-top)
OMG Flat Bottom Plates
(square) with Roofgrip #12
12-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot
asphalt
Min. 0.25-inch Dens
Deck, Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof
Board
Hot
asphalt SBS-SA
(Optional)
SBS-SA, SBS-
TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-60.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 11 of 58
TABLE 1B-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap Ply
W-36
Min. 19/32-
inch
plywood
Elastobase,
Elastobase P
(sanded-top)
OMG Flat Bottom Plates
(square) with Roofgrip #12
12-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot
asphalt
Min. 0.25-inch Dens
Deck, Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof
Board
Hot
asphalt
Polyflex SA
Base
(Optional)
APP-TA APP-TA -60.0
W-37
Min. 15/32-
inch
plywood
Polyglass G2
Base,
Elastobase,
Elastobase P
(sanded-top)
Dekfast Hex (aka, Dekfast
PLT-H-2-7/8) with Dekfast
#14, OMG 3” Round Metal
Plate with OMG HD, OMG
Flat Bottom Plate (Accutrac)
with Roofgrip #14 or Trufast
3” Metal Insulation Plate
with Trufast HD.
9-inch o.c. in 4-inch
lap and 9-inch o.c. in
four (4), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
Polytherm, ACFoam II,
ENRGY-3, Polytherm H,
H-Shield, H-Shield CG,
Multi-Max FA3
Hot
asphalt
Min. 0.25-inch Dens
Deck, Dens Deck
Prime, SECUROCK
Gypsum-Fiber Roof
Board
Hot
asphalt
Polyflex SA
Base
(Optional)
APP-TA APP-TA -82.5
TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Base Ply Ply Cap Ply
ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY:
W-38 Min. 19/32-
inch plywood
Min. 1.5-inch ENRGY
3, H-Shield or
Polytherm
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #12 or Trufast 3”
Metal Insulation Plate with Trufast
DP
1 per
1.33 ft2
Min. 0.75-inch Fesco Board
(homogeneous) or min. 0.5-inch
Structodek High Density Fiberboard
Roof Insulation
Hot
asphalt
(Optional if
using AA Ply)
BP-AA, SBS-AA
(Optional if using AA
Base) BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
W-39 Min. 15/32-
inch plywood
Min. 2-inch Polytherm,
ACFoam II, ENRGY-3,
EnergyGuard Polyiso
Insulation, H-Shield or
Multi-Max FA3
Dekfast #14 with Dekfast Hex (aka,
Dekfast PLT-H-2-7/8), OMG #14 HD
with OMG 3” Galvalume Steel Plates
or Trufast HD with Trufast 3-inch
Insulation Plates
1 per 1
ft2
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum Fiber Roof Board
Hot
asphalt
SBS-AA, SBS-
TA, APP-TA
(Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-75.0
SELF-ADHERING BASE PLY:
W-40 Min. 15/32-
inch plywood
Min. 2-inch Polytherm,
ACFoam II, ENRGY-3,
EnergyGuard Polyiso
Insulation, H-Shield or
Multi-Max FA3
Dekfast #14 with Dekfast Hex (aka,
Dekfast PLT-H-2-7/8), OMG #14 HD
with OMG 3” Galvalume Steel Plates
or Trufast HD with Trufast 3-inch
Insulation Plates
1 per 1
ft2
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum Fiber Roof Board
Hot
asphalt
Polyflex SA
Base (Optional) APP-TA APP-TA -75.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 12 of 58
TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Ply Cap Ply
ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY:
W-41 Min. 15/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Dekfast #14, OMG 3” Round Metal Plate with
OMG HD, OMG Flat Bottom Plate (Accutrac) with
Roofgrip #14 or Trufast 3” Metal Insulation Plate
with Trufast HD.
1 per 2 ft2
BP-AA, SBS-
AA, SBS-TA,
APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -30.0
W-42 Min. 15/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-
2-7/8), OMG #14 HD with OMG 3” Galvalume Steel
Plates or Trufast HD with Trufast 3-inch Insulation
Plates
1 per 1.78
ft2
SBS-AA, SBS-
TA, APP-TA
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA, SBS-
TA, APP-TA -45.0
W-43 Min. 15/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-
2-7/8), OMG #14 HD with OMG 3” Galvalume Steel
Plates or Trufast HD with Trufast 3-inch Insulation
Plates
1 per 1 ft2 SBS-AA, SBS-
TA, APP-TA
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA, SBS-
TA, APP-TA -75.0
W-44 Min. 19/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation or
min. 0.25-inch Dens Deck, Dens Deck
Prime or SECUROCK Gypsum-Fiber
Roof Board
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Dekfast #12 DP
1 per 1.33
ft2
(Optional if
using AA Ply)
BP-AA, SBS-
AA
(Optional if using
AA Base) BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA, SBS-
TA, APP-TA -82.5
SELF-ADHERING BASE PLY:
W-45 Min. 15/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch Polytherm, ACFoam II,
H-Shield or Polytherm
Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-
2-7/8), OMG #14 HD with OMG 3” Galvalume Steel
Plates or Trufast HD with Trufast 3-inch Insulation
Plates
1 per 2.67
ft2 SBS-SA
(Optional) SBS-
SA, SBS-TA, APP-
TA
SBS-SA, APP-
SA, SBS-TA,
APP-TA
-30.0
W-46 Min. 15/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch Polytherm, ACFoam II,
H-Shield or Polytherm
Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-
2-7/8), OMG #14 HD with OMG 3” Galvalume Steel
Plates or Trufast HD with Trufast 3-inch Insulation
Plates
1 per 2.67
ft2
Polyflex SA
Base
(Optional) APP-
TA APP-TA -30.0
W-47 Min. 15/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Dekfast #14, OMG 3” Round Metal Plate with
OMG HD, OMG Flat Bottom Plate (Accutrac) with
Roofgrip #14 or Trufast 3” Metal Insulation Plate
with Trufast HD.
1 per 2 ft2 SBS-SA
(Optional) SBS-
SA, SBS-TA, APP-
TA
SBS-SA, APP-
SA, SBS-TA,
APP-TA
-30.0
W-48 Min. 15/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Dekfast #14, OMG 3” Round Metal Plate with
OMG HD, OMG Flat Bottom Plate (Accutrac) with
Roofgrip #14 or Trufast 3” Metal Insulation Plate
with Trufast HD.
1 per 2 ft2 Polyflex SA
Base
(Optional) APP-
TA APP-TA -30.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 13 of 58
TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Ply Cap Ply
W-49 Min. 15/32-
inch plywood
(Optional for recover)
One or more layers, any
combination, min. 1-
inch, loose laid
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board optionally primed
with WB-3000
Polygrip #14 with Polygrip Hex Plate or Dekfast
#14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or
Dekfast Galvalume Steel 3” Round (aka, Dekfast
PLT-R-3) or OMG #14 Roofgrip with OMG 3 in.
Round Metal Plate, OMG 3 in. Ribbed Galvalume
Plate (Flat) or Accutrac Flat Bottom Plate or
Trufast #14 HD Fasteners with Trufast 3” Metal
Insulation Plate
1 per 2 ft2 SBS-SA None SBS-SA -45.0
W-50 Min. 15/32-
inch plywood
(Optional for recover)
One or more layers, any
combination, min. 1-
inch, loose laid
Min. 0.25-inch Dens Deck Prime
optionally primed with WB-3000
Polygrip #14 with Polygrip Hex Plate or Dekfast
#14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or
OMG #14 Roofgrip with OMG 3 in. Round Metal
Plate or Accutrac Flat Bottom Plate or Trufast #14
HD Fasteners with Trufast 3” Metal Insulation
Plate
1 per 2 ft2 SBS-SA None SBS-SA -45.0
W-51 Min. 15/32-
inch plywood
(Optional for recover)
One or more layers, any
combination, min. 1-
inch, loose laid
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board optionally primed
with WB-3000
Polygrip #14 with Polygrip Hex Plate or Dekfast DF-
#14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or
OMG #14 Roofgrip with OMG 3 in. Round Metal
Plate or Accutrac Flat Bottom Plate or Trufast #14
HD Fasteners with Trufast 3” Metal Insulation
Plate
1 per 1.78
ft2 SBS-SA
(Optional when
using torch-
applied Cap Ply)
SBS-TA, APP-TA
SBS-SA, APP-
SA, SBS-TA or
APP-TA
-45.0
W-52 Min. 15/32-
inch plywood
(Optional for recover)
One or more layers, any
combination, min. 1-
inch, loose laid
Min. 0.25-inch Dens Deck Prime
optionally primed with WB-3000
OMG #14 Roofgrip with OMG 3 in. Round Metal
Plate or Trufast #14 HD Fasteners with Trufast 3”
Metal Insulation Plate
1 per 1.78
ft2 SBS-SA
(Optional when
using torch-
applied Cap Ply)
SBS-TA, APP-TA
SBS-SA, APP-
SA, SBS-TA or
APP-TA
-45.0
W-53 Min. 15/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-
2-7/8), OMG #14 HD with OMG 3” Galvalume Steel
Plates or Trufast HD with Trufast 3-inch Insulation
Plates
1 per 1.78
ft2
Polyflex SA
Base
(Optional) APP-
TA APP-TA -45.0
W-54 Min. 15/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Mat Roof Board or
SECUROCK Gypsum-Fiber Roof Board
Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-
2-7/8), OMG #14 HD with OMG 3” Galvalume Steel
Plates or Trufast HD with Trufast 3-inch Insulation
Plates
1 per 1 ft2 SBS-SA (Optional) SBS-
TA, APP-TA SBS-TA, APP-TA -60.0
W-55 Min. 19/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ENRGY 3, H-Shield or
Polytherm
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Dekfast #12 DP or Trufast 3” Metal Insulation Plate
with Trufast DP
1 per 1.33
ft2 SBS-SA
(Optional) SBS-
SA, SBS-TA, APP-
TA
SBS-SA, APP-
SA, SBS-TA,
APP-TA
-82.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 14 of 58
TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No. Deck (Note 1) Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Attach Type Fasten Attach Base Ply Cap Ply
ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY:
W-56 Min. 19/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached
Elastobase, Elastobase P,
Polyglass G2 Base, CertainTeed
Glasbase, Firestone MB Base,
JM Perma-Ply 28, Tamko Glass
Base or GAFGLAS #75
OMG Flat Bottom Plates (square) with
Roofgrip #14, Dekfast Hex (aka, Dekfast PLT-
H-2-7/8) with Dekfast #14 or Trufast 3”
Metal Insulation Plate with Trufast HD
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two (2), equally spaced,
staggered center rows
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA, APP-TA -52.5
W-57 Min. 19/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Elastobase or Elastobase P OMG Flat Bottom Plates (square) with
Roofgrip #12
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two (2), equally spaced,
staggered center rows
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA, APP-TA -60.0
W-58 Min. 15/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached
Polyglass G2 Base, Elastobase,
Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Dekfast #14, OMG 3” Round Metal Plate
with OMG HD, OMG Flat Bottom Plate
(Accutrac) with Roofgrip #14 or Trufast 3”
Metal Insulation Plate with Trufast HD.
10-inch o.c. in 4-inch lap and 10-
inch o.c. in three (3), equally
spaced, staggered center rows
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA, APP-TA -75.0
W-59 Min. 15/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Polyglass APP Base
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Dekfast #14, OMG 3” Round Metal Plate
with OMG HD, OMG Flat Bottom Plate
(Accutrac) with Roofgrip #14 or Trufast 3”
Metal Insulation Plate with Trufast HD.
10-inch o.c. in 4-inch lap and 10-
inch o.c. in three (3), equally
spaced, staggered center rows
(Optional) APP-TA APP-TA -75.0
W-60 Min. 15/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached
Polyglass G2 Base, Elastobase,
Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Dekfast #14, OMG 3” Round Metal Plate
with OMG HD, OMG Flat Bottom Plate
(Accutrac) with Roofgrip #14 or Trufast 3”
Metal Insulation Plate with Trufast HD.
9-inch o.c. in 4-inch lap and 9-inch
o.c. in four (4), equally spaced,
staggered center rows
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA, APP-TA -90.0
W-61 Min. 15/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Polyglass APP Base
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Dekfast #14, OMG 3” Round Metal Plate
with OMG HD, OMG Flat Bottom Plate
(Accutrac) with Roofgrip #14 or Trufast 3”
Metal Insulation Plate with Trufast HD.
9-inch o.c. in 4-inch lap and 9-inch
o.c. in four (4), equally spaced,
staggered center rows
(Optional) APP-TA APP-TA -90.0
W-62 Min. 15/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Elastobase, Elastobase P Trufast #12 DP or Trufast #14 HD with
Trufast 3” Metal Insulation Plates
6-inch o.c. at 4-inch lap and 6-inch
o.c. in three (3), equally spaced,
staggered center rows
(Optional) BP-AA
or SBS-AA SBS-AA -90.0
W-63 Min. 15/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Elastobase, Elastobase P
OMG #12 Standard Roofgrip or OMG #14
Heavy Duty with OMG 3” Round Metal
Plates or OMG Flat Bottom Metal Plates
6-inch o.c. at 4-inch lap and 6-inch
o.c. in three (3), equally spaced,
staggered center rows
(Optional) BP-AA,
SBS-AA, SBS-TA,
APP-TA
SBS-AA, SBS-
TA or APP-TA -90.0
W-64 Min. 15/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Polyglass APP Base
OMG #12 Standard Roofgrip or OMG #14
Heavy Duty with OMG 3” Round Metal
Plates or OMG Flat Bottom Metal Plates
6-inch o.c. at 4-inch lap and 6-inch
o.c. in three (3), equally spaced,
staggered center rows
(Optional) APP-TA APP-TA -90.0
W-65 Min. 15/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Elastobase, Elastobase P Trufast #12 DP or Trufast #14 HD with
Trufast 3” Metal Insulation Plates
6-inch o.c. at 4-inch lap and 6-inch
o.c. in five (5), equally spaced,
staggered center rows
(Optional) BP-AA
or SBS-AA SBS-AA -120.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 15 of 58
TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No. Deck (Note 1) Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Attach Type Fasten Attach Base Ply Cap Ply
W-66 Min. 15/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Elastobase, Elastobase P
OMG #12 Standard Roofgrip or OMG #14
Heavy Duty with OMG 3” Round Metal
Plates or OMG Flat Bottom Metal Plates
6-inch o.c. at 4-inch lap and 6-inch
o.c. in five (5), equally spaced,
staggered center rows
(Optional) BP-AA,
SBS-AA, SBS-TA,
APP-TA
SBS-AA, SBS-
TA or APP-TA -120.0
W-67 Min. 15/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Polyglass APP Base
OMG #12 Standard Roofgrip or OMG #14
Heavy Duty with OMG 3” Round Metal
Plates or OMG Flat Bottom Metal Plates
6-inch o.c. at 4-inch lap and 6-inch
o.c. in five (5), equally spaced,
staggered center rows
(Optional) APP-TA APP-TA -120.0
SELF-ADHERING BASE PLY:
W-68 Min. 19/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached
Elastobase, Elastobase P (poly-
film top)
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Dekfast #14 or Trufast 3” Metal Insulation
Plate with Trufast HD
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two, equally spaced,
staggered center rows
SBS-SA
SBS-SA, APP-
SA, SBS-TA or
APP-TA
-52.5*
W-69 Min. 19/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached
Elastobase, Elastobase P (poly-
film top)
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Dekfast #14 or Trufast 3” Metal Insulation
Plate with Trufast HD
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two, equally spaced,
staggered center rows
Polyflex SA Base APP-TA -52.5*
W-70 Min. 19/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached
Elastobase, Elastobase P (poly-
film top)
OMG Flat Bottom Plates (square) with
Roofgrip #12
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two, equally spaced,
staggered center rows
SBS-SA
SBS-SA, APP-
SA, SBS-TA or
APP-TA
-60.0*
W-71 Min. 19/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached
Elastobase, Elastobase P (poly-
film top)
OMG Flat Bottom Plates (square) with
Roofgrip #12
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two, equally spaced,
staggered center rows
Polyflex SA Base APP-TA -60.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 16 of 58
TABLE 1F-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER
System
No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Cap Ply
NO BASE PLY:
W-72 Min. 15/32-
inch plywood Elastobase, Elastobase P Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two
(2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-
TA -45.0*
W-73 Min. 15/32-
inch plywood Elastobase, Elastobase P Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-
TA -52.5
W-74 Min. 15/32-
inch plywood Elastobase, Elastobase P Original Simplex Cap Nails (1-inch metal head diameter,
11 gauge x min. 1.25-inch long annular grooved shank)
6-inch o.c. at 3-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-
TA -52.5
W-75 Min. 15/32-
inch plywood
Elastobase, Elastobase P (poly-film
top)
Original Simplex Cap Nails (1-inch metal head diameter,
11 gauge x min. 1.25-inch long annular grooved shank)
6-inch o.c. at 3-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows None SBS-SA, APP-SA -52.5
W-76 Min. 15/32-
inch plywood Polyglass APP Base Original Simplex Cap Nails (1-inch metal head diameter,
11 gauge x min. 1.25-inch long annular grooved shank)
6-inch o.c. at 3-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows None APP-TA -52.5
W-77 Min. 19/32-
inch plywood
Elastobase, Elastobase P, Polyglass
G2 Base, CertainTeed Glasbase,
Firestone MB Base, JM Perma-Ply
28, Tamko Glass Base or GAFGLAS
#75
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
8-inch o.c. in 4-inch lap and 8-inch o.c. in three
(3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-
TA -60.0
W-78 Min. 19/32-
inch plywood
Elastobase, Elastobase P (poly-film
top)
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
8-inch o.c. in 4-inch lap and 8-inch o.c. in three
(3), equally spaced, staggered center rows None SBS-SA, APP-SA -60.0
W-79 Min. 15/32-
inch plywood
Polyglass G2 Base, Elastobase,
Elastobase P
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
8-inch o.c. in 4-inch lap and 8-inch o.c. in four
(4), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-
TA -67.5
W-80 Min. 15/32-
inch plywood Polyglass APP Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
8-inch o.c. in 4-inch lap and 8-inch o.c. in four
(4), equally spaced, staggered center rows None APP-TA -67.5
W-81 Min. 15/32-
inch plywood
Polyglass G2 Base, Elastobase,
Elastobase P Simplex MAXX Cap
10-inch o.c. in 4-inch lap and 10-inch o.c. in
three (3), equally spaced, staggered center
rows
None SBS-AA, SBS-TA, APP-
TA -75.0
W-82 Min. 15/32-
inch plywood Polyglass APP Base Simplex MAXX Cap
10-inch o.c. in 4-inch lap and 10-inch o.c. in
three (3), equally spaced, staggered center
rows
None APP-TA -75.0
W-83 Min. 15/32-
inch plywood
Polyglass G2 Base, Elastobase,
Elastobase P Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four
(4), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-
TA -90.0
W-84 Min. 15/32-
inch plywood Polyglass APP Base Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four
(4), equally spaced, staggered center rows None APP-TA -90.0
W-85 Min. 15/32-
inch plywood Elastobase, Elastobase P Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two
(2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-
TA -90.0
W-86 Min. 19/32-
inch plywood
Elastobase, Elastobase P (poly-film
top)
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails.
4-inch o.c. in 4-inch lap and 4-inch o.c. in four
(4), equally spaced, staggered center rows None SBS-SA, APP-SA -97.5
W-87 Min. 15/32-
inch plywood Elastobase, Elastobase P Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three
(3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-
TA -105.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 17 of 58
TABLE 1F-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER
System
No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Cap Ply
W-88 Min. 19/32-
inch plywood Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
6-inch o.c. in 4-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-
TA -112.5
W-89 Min. 19/32-
inch plywood
Elastobase, Elastobase P (poly-film
top)
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails. Note: Tin caps are to be primed with
PG100 or ASTM D41 primer.
6-inch o.c. in 4-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows None SBS-SA, APP-SA -112.5
ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY:
W-90 Min. 15/32-
inch plywood Elastobase, Elastobase P Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two
(2), equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -45.0*
W-91 Min. 15/32-
inch plywood Elastobase, Elastobase P Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -52.5
W-92 Min. 15/32-
inch plywood Elastobase, Elastobase P Original Simplex Cap Nails (1-inch metal head diameter,
11 gauge x min. 1.25-inch long annular grooved shank)
6-inch o.c. at 3-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -52.5
W-93 Min. 15/32-
inch plywood Polyglass APP Base Original Simplex Cap Nails (1-inch metal head diameter,
11 gauge x min. 1.25-inch long annular grooved shank)
6-inch o.c. at 3-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows APP-TA APP-TA -52.5
W-94 Min. 19/32-
inch plywood
Elastobase, Elastobase P, Polyglass
G2 Base, CertainTeed Glasbase,
Firestone MB Base, JM Perma-Ply
28, Tamko Glass Base or GAFGLAS
#75
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
8-inch o.c. in 4-inch lap and 8-inch o.c. in three
(3), equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -60.0
W-95 Min. 15/32-
inch plywood
Polyglass G2 Base, Elastobase,
Elastobase P
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
8-inch o.c. in 4-inch lap and 8-inch o.c. in four
(4), equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -67.5
W-96 Min. 15/32-
inch plywood Polyglass APP Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
8-inch o.c. in 4-inch lap and 8-inch o.c. in four
(4), equally spaced, staggered center rows APP-TA APP-TA -67.5
W-97 Min. 15/32-
inch plywood
Polyglass G2 Base, Elastobase,
Elastobase P Simplex MAXX Cap
10-inch o.c. in 4-inch lap and 10-inch o.c. in
three (3), equally spaced, staggered center
rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -75.0
W-98 Min. 15/32-
inch plywood Polyglass APP Base Simplex MAXX Cap
10-inch o.c. in 4-inch lap and 10-inch o.c. in
three (3), equally spaced, staggered center
rows
APP-TA APP-TA -75.0
W-99 Min. 15/32-
inch plywood
Polyglass G2 Base, Elastobase,
Elastobase P Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four
(4), equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -90.0
W-100 Min. 15/32-
inch plywood Polyglass APP Base Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four
(4), equally spaced, staggered center rows APP-TA APP-TA -90.0
W-101 Min. 15/32-
inch plywood Elastobase, Elastobase P Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two
(2), equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -90.0
W-102 Min. 15/32-
inch plywood Elastobase, Elastobase P Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three
(3), equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -105.0
W-103 Min. 19/32-
inch plywood Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
6-inch o.c. in 4-inch lap and 6-inch o.c. in four
(3), equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -112.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 18 of 58
TABLE 1F-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER
System
No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Cap Ply
SELF-ADHERING BASE PLY:
W-104 Min. 15/32-
inch plywood
Elastobase, Elastobase P (poly-film
top)
Original Simplex Cap Nails (1-inch metal head diameter,
11 gauge x min. 1.25-inch long annular grooved shank)
6-inch o.c. at 3-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-
TA, APP-TA -52.5
W-105 Min. 15/32-
inch plywood
Polyglass APP Base, Elastobase,
Elastobase P (poly-film top)
Original Simplex Cap Nails (1-inch metal head diameter,
11 gauge x min. 1.25-inch long annular grooved shank)
6-inch o.c. at 3-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows Polyflex SA Base APP-TA -52.5
W-106 Min. 19/32-
inch plywood
Elastobase, Elastobase P (poly-film
top)
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
8-inch o.c. in 4-inch lap and 8-inch o.c. in three
(3), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-
TA, APP-TA -60.0
W-107 Min. 19/32-
inch plywood
Elastobase, Elastobase P (poly-film
top)
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
8-inch o.c. in 4-inch lap and 8-inch o.c. in three
(3), equally spaced, staggered center rows Polyflex SA Base APP-TA -60.0
W-108 Min. 19/32-
inch plywood
Elastobase, Elastobase P (poly-film
top)
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails.
4-inch o.c. in 4-inch lap and 4-inch o.c. in four
(4), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-
TA, APP-TA -97.5
W-109 Min. 19/32-
inch plywood
Elastobase, Elastobase P (poly-film
top)
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails.
4-inch o.c. in 4-inch lap and 4-inch o.c. in four
(4), equally spaced, staggered center rows Polyflex SA Base APP-TA -97.5
W-110 Min. 19/32-
inch plywood
Elastobase, Elastobase P (poly-film
top)
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails. Note: Tin caps are to be primed with
PG100 or ASTM D41 primer.
6-inch o.c. in 4-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows
Elastoflex SA V Plus,
Elastoflex SA V Plus
FR
SBS-SA, APP-SA, SBS-
TA, APP-TA -112.5
W-111 Min. 19/32-
inch plywood
Elastobase, Elastobase P (poly-film
top)
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails. Note: Tin caps are to be primed with
PG100 or ASTM D41 primer.
6-inch o.c. in 4-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows Polyflex SA Base APP-TA -112.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 19 of 58
TABLE 1F-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER
System
No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Cap
NO BASE PLY:
W-112 Min. 19/32-
inch plywood
Elastobase, Elastobase P,
Polyglass G2 Base,
CertainTeed Glasbase,
Firestone MB Base, JM
Perma-Ply 28, Tamko Glass
Base or GAFGLAS #75
OMG Flat Bottom Plates (square) with Roofgrip #14,
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
or Trufast 3” Metal Insulation Plate with Trufast HD
12-inch o.c. in 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-
TA -52.5
W-113 Min. 19/32-
inch plywood Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-
TA -60.0
W-114 Min. 15/32-
inch plywood
Polyglass G2 Base,
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14,
OMG 3” Round Metal Plate with OMG HD, OMG Flat
Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3”
Metal Insulation Plate with Trufast HD.
10-inch o.c. in 4-inch lap and 10-inch o.c. in three
(3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-
TA -75.0
W-115 Min. 15/32-
inch plywood Polyglass APP Base
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14,
OMG 3” Round Metal Plate with OMG HD, OMG Flat
Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3”
Metal Insulation Plate with Trufast HD.
10-inch o.c. in 4-inch lap and 10-inch o.c. in three
(3), equally spaced, staggered center rows None APP-TA -75.0
W-116 Min. 15/32-
inch plywood
Polyglass G2 Base,
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14,
OMG 3” Round Metal Plate with OMG HD, OMG Flat
Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3”
Metal Insulation Plate with Trufast HD.
9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4),
equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-
TA -90.0
W-117 Min. 15/32-
inch plywood Polyglass APP Base
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14,
OMG 3” Round Metal Plate with OMG HD, OMG Flat
Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3”
Metal Insulation Plate with Trufast HD.
9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4),
equally spaced, staggered center rows None APP-TA -90.0
W-118 Min. 15/32-
inch plywood Elastobase, Elastobase P Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal
Insulation Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3),
equally spaced, staggered center rows None SBS-AA -90.0
W-119 Min. 15/32-
inch plywood Elastobase, Elastobase P
OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with
OMG 3” Round Metal Plates or OMG Flat Bottom Metal
Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3),
equally spaced, staggered center rows None SBS-AA, SBS-TA or
APP-TA -90.0
W-120 Min. 15/32-
inch plywood Polyglass APP Base
OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with
OMG 3” Round Metal Plates or OMG Flat Bottom Metal
Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3),
equally spaced, staggered center rows None APP-TA -90.0
W-121 Min. 15/32-
inch plywood Elastobase, Elastobase P Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal
Insulation Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5),
equally spaced, staggered center rows None SBS-AA -120.0
W-122 Min. 15/32-
inch plywood Elastobase, Elastobase P
OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with
OMG 3” Round Metal Plates or OMG Flat Bottom Metal
Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5),
equally spaced, staggered center rows None SBS-AA, SBS-TA or
APP-TA -120.0
W-123 Min. 15/32-
inch plywood Polyglass APP Base
OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with
OMG 3” Round Metal Plates or OMG Flat Bottom Metal
Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5),
equally spaced, staggered center rows None APP-TA -120.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 20 of 58
TABLE 1F-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER
System
No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Cap
ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY:
W-124 Min. 19/32-
inch plywood
Elastobase, Elastobase P,
Polyglass G2 Base,
CertainTeed Glasbase,
Firestone MB Base, JM
Perma-Ply 28, Tamko Glass
Base or GAFGLAS #75
OMG Flat Bottom Plates (square) with Roofgrip #14,
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
or Trufast 3” Metal Insulation Plate with Trufast HD
12-inch o.c. in 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -52.5
W-125 Min. 19/32-
inch plywood Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -60.0
W-126 Min. 15/32-
inch plywood
Polyglass G2 Base,
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14,
OMG 3” Round Metal Plate with OMG HD, OMG Flat
Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3”
Metal Insulation Plate with Trufast HD.
10-inch o.c. in 4-inch lap and 10-inch o.c. in three
(3), equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -75.0
W-127 Min. 15/32-
inch plywood Polyglass APP Base
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14,
OMG 3” Round Metal Plate with OMG HD, OMG Flat
Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3”
Metal Insulation Plate with Trufast HD.
10-inch o.c. in 4-inch lap and 10-inch o.c. in three
(3), equally spaced, staggered center rows APP-TA APP-TA -75.0
W-128 Min. 15/32-
inch plywood
Polyglass G2 Base,
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14,
OMG 3” Round Metal Plate with OMG HD, OMG Flat
Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3”
Metal Insulation Plate with Trufast HD.
9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4),
equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -90.0
W-129 Min. 15/32-
inch plywood Polyglass APP Base
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14,
OMG 3” Round Metal Plate with OMG HD, OMG Flat
Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3”
Metal Insulation Plate with Trufast HD.
9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4),
equally spaced, staggered center rows APP-TA APP-TA -90.0
W-130 Min. 15/32-
inch plywood Elastobase, Elastobase P Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal
Insulation Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3),
equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -90.0
W-131 Min. 15/32-
inch plywood Elastobase, Elastobase P
OMG #12 Standard Roofgrip or OMG #14 Heavy Duty
(min. 1-5/8-inch long) with OMG 3” Round Metal Plates or
OMG Flat Bottom Metal Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3),
equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -90.0
W-132 Min. 15/32-
inch plywood Polyglass APP Base
OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with
OMG 3” Round Metal Plates or OMG Flat Bottom Metal
Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3),
equally spaced, staggered center rows APP-TA APP-TA -90.0
W-133 Min. 15/32-
inch plywood Elastobase, Elastobase P Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal
Insulation Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5),
equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -120.0
W-134 Min. 15/32-
inch plywood Elastobase, Elastobase P
OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with
OMG 3” Round Metal Plates or OMG Flat Bottom Metal
Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5),
equally spaced, staggered center rows
BP-AA, SBS-AA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
AA, SBS-TA, APP-TA -120.0
W-135 Min. 15/32-
inch plywood Polyglass APP Base
OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with
OMG 3” Round Metal Plates or OMG Flat Bottom Metal
Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5),
equally spaced, staggered center rows APP-TA APP-TA -120.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 21 of 58
TABLE 1F-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER
System
No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Cap
SELF-ADHERING BASE PLY:
W-136 Min. 19/32-
inch plywood
Elastobase, Elastobase P
(poly-film top)
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
or Trufast 3” Metal Insulation Plate with Trufast HD
12-inch o.c. in 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-
TA, APP-TA -52.5*
W-137 Min. 19/32-
inch plywood
Elastobase, Elastobase P
(poly-film top)
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
or Trufast 3” Metal Insulation Plate with Trufast HD
12-inch o.c. in 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows Polyflex SA Base APP-TA -52.5*
W-138 Min. 19/32-
inch plywood
Elastobase, Elastobase P
(poly-film top) OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-
TA, APP-TA -60.0*
W-139 Min. 19/32-
inch plywood
Elastobase, Elastobase P
(poly-film top) OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows Polyflex SA Base APP-TA -60.0*
TABLE 1G: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System
No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Joint Treatment Base Ply Ply Cap Ply
W-140 Min. 15/32-
inch plywood None None SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
TA, APP-TA -90.0
W-141 Min. 15/32-
inch plywood (Optional) PG100 None Polyflex SA Base (Optional) APP-TA APP-TA -90.0
W-142 Min. 15/32-
inch plywood PG100 None SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
TA, APP-TA -97.5
W-143 Min. 15/32-
inch plywood (Optional) PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
place to create continuous bond.
Elastoflex SA V Base or
Elastoflex SA V FR Base
(Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
TA, APP-TA -97.5
W-144 Min. 15/32-
inch plywood WB-3000 None SBS-SA (Optional) SBS-SA, APP-SA, SBS-
TA, APP-TA -105.0
W-145 Min. 15/32-
inch plywood (Optional) PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
place to create continuous bond.
Elastoflex SA V Plus or
Elastoflex SA V Plus FR
(Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA, SBS-
TA, APP-TA -135.0
W-146 Min. 15/32-
inch plywood (Optional) PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
place to create continuous bond. Polyflex SA Base (Optional) APP-TA APP-TA -135.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 22 of 58
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Base Ply Ply Cap Ply
SELF-ADHERING BASE:
SC-1.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per 4
ft2
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Mat Roof Board or
SECUROCK Gypsum-Fiber Roof Board
PRIMER: WB-3000
D-IS SBS-SA None
SBS-CA1,
SBS-CA2,
APP-CA1
-30.0*
SC-2.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per
1.6 ft2
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Mat Roof Board or
SECUROCK Gypsum-Fiber Roof Board
PRIMER: WB-3000
D-IS SBS-SA None
SBS-CA1,
SBS-CA2,
APP-CA1
-45.0
SC-3.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per 4
ft2
Min. 0.25-inch Dens Deck, Dens Deck
Prime, DEXcell FA Glass Mat Roof
Board, SECUROCK Gypsum-Fiber Roof
Board or SECUROCK Glass-Mat Roof
Board, min. 7/16-inch DEXcell
Cement Roof Board or min. 0.5-inch
SECUROCK Cement Roof Board
PRIMER: WB-3000
M-OSFA
or M-PG1 SBS-SA None
SBS-CA1,
SBS-CA2,
APP-CA1
-30.0*
SC-4.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per
1.6 ft2
Min. 0.25-inch Dens Deck, Dens Deck
Prime, DEXcell FA Glass Mat Roof
Board, SECUROCK Gypsum-Fiber Roof
Board or SECUROCK Glass-Mat Roof
Board, min. 7/16-inch DEXcell
Cement Roof Board or min. 0.5-inch
SECUROCK Cement Roof Board
PRIMER: WB-3000
M-OSFA
or M-PG1 SBS-SA None
SBS-CA1,
SBS-CA2,
APP-CA1
-45.0
SC-5.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per 4
ft2
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Matg Roof Board or
SECUROCK Gypsum-Fiber Roof Board
PRIMER: WB-3000
OB500 SBS-SA None
SBS-CA1,
SBS-CA2,
APP-CA1
-30.0*
SC-6.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per
1.6 ft2
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Matg Roof Board or
SECUROCK Gypsum-Fiber Roof Board
PRIMER: WB-3000
OB500 SBS-SA None
SBS-CA1,
SBS-CA2,
APP-CA1
-45.0
SC-7.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per 4
ft2
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
PRIMER: WB-3000
CR-20 SBS-SA None
SBS-CA1,
SBS-CA2,
APP-CA1
-30.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 23 of 58
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Base Ply Ply Cap Ply
SC-8.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per
1.6 ft2
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
PRIMER: WB-3000
CR-20 SBS-SA None
SBS-CA1,
SBS-CA2,
APP-CA1
-45.0
ASPHALT-APPLIED BASE:
SC-9.
Min. 22 ga., type
B, Grade 33 steel
or min. 2,500 psi
structrual
concrete
Min. 1.5-inch Polytherm,
ACFoam II, ENRGY 3, H-
Shield or Polytherm
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, Trufast 3”
Metal Insulation Plate with Trufast
HD or OMG 3-inch Galv Plate with
OMD HD
1 per 2
ft2
Min. 0.75-inch Fesco Board
(homogeneous) or min. 0.5-inch
Structodek High Density Fiberboard
Roof Insulation
Hot
asphalt
(Optional if
using AA
Ply) BP-AA,
SBS-AA
(Optional if using
AA Base) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
SC-10.
Min. 22 ga., type
B, Grade 33 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3, H-
Shield or Polytherm
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, Trufast 3”
Metal Insulation Plate with Trufast
HD or OMG 3-inch Galv Plate with
OMD HD
1 per 4
ft2
Min. 0.75-inch Fesco Board
(homogeneous) or min. 0.5-inch
Structodek High Density Fiberboard
Roof Insulation
Hot
asphalt
(Optional if
using AA
Ply) BP-AA,
SBS-AA
(Optional if using
AA Base) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
SC-11.
Min. 22 ga., type
B, Grade 33 steel
or min. 2,500 psi
structrual
concrete
Min. 1.5-inch ENRGY 3, H-
Shield or Polytherm
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14 or Trufast 3”
Metal Insulation Plate with Trufast
HD
1 per
1.33 ft2
Min. 0.75-inch Fesco Board
(homogeneous) or min. 0.5-inch
Structodek High Density Fiberboard
Roof Insulation
Hot
asphalt
(Optional if
using AA
Ply) BP-AA,
SBS-AA
(Optional if using
AA Base) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-90.0
SC-12.
Min. 22 ga., type
B, Grade 33 steel
or min. 2,500 psi
structrual
concrete
Min. 1.5-inch ENRGY 3, H-
Shield or Polytherm
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14 or Trufast 3”
Metal Insulation Plate with Trufast
HD
1 per
1.33 ft2
Min. 0.75-inch Fesco Board
(homogeneous) or min. 0.5-inch
Structodek High Density Fiberboard
Roof Insulation
Hot
asphalt
BP-AA, SBS-
AA (Top
surface
primed with
PG100
primer)
SBS-SA, SBS-TA or
APP-TA
SBS-SA,
APP-SA,
SBS-TA or
APP-TA
-90.0
COLD-APPLIED BASE:
SC-13.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per 4
ft2
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Mat Roof Board or
SECUROCK Gypsum-Fiber Roof Board
D-IS SBS-CA1,
SBS-CA2
(Optional) SBS-CA1,
SBS-CA2
SBS-CA1,
SBS-CA2,
APP-CA1
-30.0*
SC-14.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per
1.6 ft2
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Mat Roof Board or
SECUROCK Gypsum-Fiber Roof Board
D-IS SBS-CA1,
SBS-CA2
(Optional) SBS-CA1,
SBS-CA2
SBS-CA1,
SBS-CA2,
APP-CA1
-45.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 24 of 58
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Base Ply Ply Cap Ply
SC-15.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per 4
ft2
Min. 0.25-inch Dens Deck, Dens Deck
Prime, DEXcell FA Glass Mat Roof
Board, SECUROCK Gypsum-Fiber Roof
Board or SECUROCK Glass-Mat Roof
Board, min. 7/16-inch DEXcell
Cement Roof Board or min. 0.5-inch
SECUROCK Cement Roof Board
M-OSFA
or M-PG1
SBS-CA1,
SBS-CA2
(Optional) SBS-CA1,
SBS-CA2
SBS-CA1,
SBS-CA2,
APP-CA1
-30.0*
SC-16.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per
1.6 ft2
Min. 0.25-inch Dens Deck, Dens Deck
Prime, DEXcell FA Glass Mat Roof
Board, SECUROCK Gypsum-Fiber Roof
Board or SECUROCK Glass-Mat Roof
Board, min. 7/16-inch DEXcell
Cement Roof Board or min. 0.5-inch
SECUROCK Cement Roof Board
M-OSFA
or M-PG1
SBS-CA1,
SBS-CA2
(Optional) SBS-CA1,
SBS-CA2
SBS-CA1,
SBS-CA2,
APP-CA1
-45.0
SC-17.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per 4
ft2
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Matg Roof Board or
SECUROCK Gypsum-Fiber Roof Board
OB500 SBS-CA1,
SBS-CA2
(Optional) SBS-CA1,
SBS-CA2
SBS-CA1,
SBS-CA2,
APP-CA1
-30.0*
SC-18.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per
1.6 ft2
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Matg Roof Board or
SECUROCK Gypsum-Fiber Roof Board
OB500 SBS-CA1,
SBS-CA2
(Optional) SBS-CA1,
SBS-CA2
SBS-CA1,
SBS-CA2,
APP-CA1
-45.0
SC-19.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per 4
ft2
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-CA1,
SBS-CA2
(Optional) SBS-CA1,
SBS-CA2
SBS-CA1,
SBS-CA2,
APP-CA1
-30.0*
SC-20.
Min. 22 ga., type
B, Grade 40 steel
or min. 2,500 psi
structrual
concrete
Min. 2-inch Polytherm,
ACFoam II, ENRGY 3,
EnergyGuard Polyiso
Insulation, Polytherm H, H-
Shield or Multi-Max FA3
Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) with Dekfast #14, OMG 3”
Galvalume Ribbons Plates with OMG
#14 Roofgrip or Trufast 3” Metal
Insulation Plate with Trufast HD
1 per
1.6 ft2
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-CA1,
SBS-CA2
(Optional) SBS-CA1,
SBS-CA2
SBS-CA1,
SBS-CA2,
APP-CA1
-45.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 25 of 58
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Ply Cap Ply
SELF-ADHERING BASE:
SC-21.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
(Optional) One or
more layers, any
combination, loose
laid
Min. 1.5-inch Polytherm,
ACFoam II, H-Shield or
Polytherm
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP
(steel only) or Dekfast #14, OMG AccuTrac Flat Bottom
Plate with #12 Roofgrip (steel only) or OMG #14 Heavy
Duty, Trufast 3” Metal Insulation Plate with Trufast #12 DP
(steel only) or Trufast #14 HD
1 per
2.67 ft2 SBS-SA (Optional) SBS-SA,
SBS-TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-30.0
SC-22.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
(Optional) One or
more layers, any
combination, loose
laid
Min. 1.5-inch Polytherm,
ACFoam II, H-Shield or
Polytherm
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP
(steel only) or Dekfast #14, OMG AccuTrac Flat Bottom
Plate with #12 Roofgrip (steel only) or OMG #14 Heavy
Duty, Trufast 3” Metal Insulation Plate with Trufast #12 DP
(steel only) or Trufast #14 HD
1 per
2.67 ft2
Polyflex SA
Base (Optional) APP-TA APP-TA -30.0
SC-23.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination, min.
1-inch, loose laid
Min. 0.25-inch Dens Deck
Prime optionally primed
with WB-3000
Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or
Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast
PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with
OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast
#15 EHD Fasteners with Trufast 3” Metal Insulation Plate
1 per
2.67 ft2 SBS-SA (Optional) SBS-SA,
SBS-TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-37.5*
SC-24.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination, min.
1-inch, loose laid
Min. 0.25-inch Dens Deck
Prime optionally primed
with WB-3000
Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or
Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast
PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with
OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast
#15 EHD Fasteners with Trufast 3” Metal Insulation Plate
1 per
2.67 ft2
Polyflex SA
Base (Optional) APP-TA APP-TA -37.5*
SC-25.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination, min.
1-inch, loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
optionally primed with
WB-3000
Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or
Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast
PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with
OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate
or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast
3” Metal Insulation Plate
1 per
2.67 ft2 SBS-SA (Optional) SBS-SA,
SBS-TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-37.5*
SC-26.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination, min.
1-inch, loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
optionally primed with
WB-3000
Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or
Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast
PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with
OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate
or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast
3” Metal Insulation Plate
1 per
2.67 ft2
Polyflex SA
Base (Optional) APP-TA APP-TA -37.5*
SC-27.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination, min.
1-inch, loose laid
Min. 0.25-inch DEXcell FA
Glass Mat Roof Board
optionally primed with
WB-3000
Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or
Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast
PLT-H-2-7/8), isofast PLT-S-2-3/4X2-3/4 or Dekfast
Galvalume Steel 3” Round (aka, Dekfast PLT-R-3) or OMG
#14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal
Plate or Accutrac Flat Bottom Plate or Trufast #14 HD or
Trufast #15 EHD Fasteners with Trufast 3” Metal Insulation
Plate
1 per
2.67 ft2 SBS-SA (Optional) SBS-SA,
SBS-TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-37.5*
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 26 of 58
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Ply Cap Ply
SC-28.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination, min.
1-inch, loose laid
Min. 0.25-inch DEXcell FA
Glass Mat Roof Board
optionally primed with
WB-3000
Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or
Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast
PLT-H-2-7/8), isofast PLT-S-2-3/4X2-3/4 or Dekfast
Galvalume Steel 3” Round (aka, Dekfast PLT-R-3) or OMG
#14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal
Plate or Accutrac Flat Bottom Plate or Trufast #14 HD or
Trufast #15 EHD Fasteners with Trufast 3” Metal Insulation
Plate
1 per
2.67 ft2
Polyflex SA
Base (Optional) APP-TA APP-TA -37.5*
SC-29.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
(Optional) One or
more layers, any
combination, loose
laid
Min. 1.5-inch H-Shield or
Polytherm
OMG AccuTrac Flat Bottom Plate with #12 Roofgrip (steel
only) or OMG #14 Heavy Duty, Trufast 3” Metal Insulation
Plate with Trufast #12 DP (steel only) or Trufast #14 HD
1 per 2
ft2 SBS-SA (Optional) SBS-SA,
SBS-TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-45.0*
SC-30.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
(Optional) One or
more layers, any
combination, loose
laid
Min. 1.5-inch H-Shield or
Polytherm
OMG AccuTrac Flat Bottom Plate with #12 Roofgrip (steel
only) or OMG #14 Heavy Duty, Trufast 3” Metal Insulation
Plate with Trufast #12 DP (steel only) or Trufast #14 HD
1 per 2
ft2
Polyflex SA
Base (Optional) APP-TA APP-TA -45.0*
SC-31.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination,
loose laid
Min. 0.25-inch Dens Deck
Prime or SECUROCK
Gypsum-Fiber Roof Board
optionally primed with
WB-3000
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14,
OMG 3” Galvalume Ribbed Plates with OMG #14 RoofGrip
or Trufast 3” Metal Insulation Plates with Trufast #14 HD
Fasteners
1 per 2
ft2 SBS-SA None
SBS-CA1,
SBS-CA2,
APP-CA1
-45.0*
SC-32.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination,
loose laid
Min. 0.25-inch Dens Deck
Prime or SECUROCK
Gypsum-Fiber Roof Board
optionally primed with
WB-3000
OMG 3 in. Galvalume Plate (non-ribbed) with #12 Roofgrip
(steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka,
Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel only) or
Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast
#12 DP (steel only) or Trufast #14 HD
1 per 2
ft2 SBS-SA (Optional) SBS-SA,
SBS-TA or APP-TA
SBS-SA,
APP-SA,
SBS-TA or
APP-TA
-45.0*
SC-33.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination, min.
1-inch, loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
optionally primed with
WB-3000
Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast
Galvalume Steel 3” Round (aka, Dekfast PLT-R-3) or OMG
#14 Roofgrip with OMG 3 in. Round Metal Plate, OMG 3 in.
Ribbed Galvalume Plate (Flat) or Accutrac Flat Bottom Plate
or Trufast #14 HD Fasteners with Trufast 3” Metal
Insulation Plate
1 per 2
ft2 SBS-SA None SBS-SA -45.0
SC-34.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination, min.
1-inch, loose laid
Min. 0.25-inch Dens Deck
Prime optionally primed
with WB-3000
Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14
Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat
Bottom Plate or Trufast #14 HD Fasteners with Trufast 3”
Metal Insulation Plate
1 per 2
ft2 SBS-SA None SBS-SA -45.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 27 of 58
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Ply Cap Ply
SC-35.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination, min.
1-inch, loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
optionally primed with
WB-3000
Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or
Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast
PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with
OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate
or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast
3” Metal Insulation Plate
1 per
1.78 ft2 SBS-SA
(Optional when
using torch-applied
Cap Ply) SBS-TA,
APP-TA
SBS-SA,
APP-SA,
SBS-TA or
APP-TA
-45.0
SC-36.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination, min.
1-inch, loose laid
Min. 0.25-inch Dens Deck
Prime optionally primed
with WB-3000
OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round
Metal Plate or Trufast #14 HD or Trufast #15 EHD Fasteners
with Trufast 3” Metal Insulation Plate
1 per
1.78 ft2 SBS-SA
(Optional when
using torch-applied
Cap Ply) SBS-TA,
APP-TA
SBS-SA,
APP-SA,
SBS-TA or
APP-TA
-45.0
SC-37.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
(Optional) One or
more layers, any
combination, loose
laid
Min. 1.5-inch H-Shield or
Polytherm
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP
(steel only) or Dekfast #14
1 per 2
ft2 SBS-SA (Optional) SBS-SA,
SBS-TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-60.0
SC-38.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination,
loose laid
Min. 0.25-inch Dens Deck
Prime or SECUROCK
Gypsum-Fiber Roof Board
optionally primed with
WB-3000
OMG 3 in. Galvalume Plate (non-ribbed) with #12 Roofgrip
(steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka,
Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel only) or
Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast
#12 DP (steel only) or Trufast #14 HD
1 per
1.6 ft2 SBS-SA (Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -60.0
SC-39.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination,
loose laid
Min. 0.25-inch Dens Deck
Prime or SECUROCK
Gypsum-Fiber Roof Board
optionally primed with
WB-3000
OMG 3 in. Galvalume Plate (non-ribbed) with #12 Roofgrip
(steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka,
Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel only) or
Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast
#12 DP (steel only) or Trufast #14 HD
1 per
1.33 ft2 SBS-SA (Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -72.5
SC-40.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
(Optional) One or
more layers, any
combination, loose
laid
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board OMG 3-inch Galvalume Steel Plate with OMG #14 HD 1 per
1.78 ft2 SBS-SA (Optional) SBS-TA SBS-TA -75.0
SC-41.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
(Optional) One or
more layers, any
combination, loose
laid
Min. 1.5-inch ENRGY 3, H-
Shield or Polytherm
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12
(steel only) or #14 or Trufast 3” Metal Insulation Plate with
Trufast DP (steel only) or HD
1 per
1.33 ft2 SBS-SA (Optional) SBS-SA,
SBS-TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-82.5
SC-42.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination, min.
1-inch, loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
optionally primed with
WB-3000
Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or
Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast
PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with
OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate
or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast
3” Metal Insulation Plate
1 per 1
ft2 SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA,
APP-TA -90.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 28 of 58
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Ply Cap Ply
SC-43.
Min. 22 ga., type B,
Grade 40 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination, min.
1-inch, loose laid
Min. 0.25-inch Dens Deck
Prime optionally primed
with WB-3000
Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or
Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast
PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with
OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast
#15 EHD Fasteners with Trufast 3” Metal Insulation Plate
1 per 1
ft2 SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA,
APP-TA -97.5
ASPHALT-APPLIED BASE:
SC-44.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
One or more layers,
any combination,
loose laid
Min. 0.75-inch JM Fesco
Board (homogeneous) or
min. 1.5-inch JM Fesco
Board (laminated)
OMG AccuTrac Plate or OMG 3 in. Ribbed Galvalume Plate
with #12 Roofgrip (steel only) or OMG #14 Heavy Duty,
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP
(steel only) or Dekfast #14, Trufast 3” Metal Insulation Plate
with Trufast #12 DP (steel only) or Trufast #14 HD
1 per 2
ft2
(Optional if
using AA Ply)
BP-AA, SBS-
AA
(Optional if using
AA Base) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
SC-45.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
One or more layers,
any combination,
loose laid
Min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation or G-P
FiberBase HD or HD Excel
OMG AccuTrac Plate or OMG 3 in. Ribbed Galvalume Plate
with #12 Roofgrip (steel only) or OMG #14 Heavy Duty,
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP
(steel only) or Dekfast #14, Trufast 3” Metal Insulation Plate
with Trufast #12 DP (steel only) or Trufast #14 HD
1 per 4
ft2
(Optional if
using AA Ply)
BP-AA, SBS-
AA
(Optional if using
AA Base) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
SC-46.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
One or more layers,
any combination,
loose laid
Min. 0.25-inch Dens Deck
Prime or SECUROCK
Gypsum-Fiber Roof Board
OMG AccuTrac Plate or OMG 3 in. Ribbed Galvalume Plate
with #12 Roofgrip (steel only) or OMG #14 Heavy Duty,
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP
(steel only) or Dekfast #14, Trufast 3” Metal Insulation Plate
with Trufast #12 DP (steel only) or Trufast #14 HD
1 per 4
ft2
(Optional if
using AA Ply)
BP-AA, SBS-
AA
(Optional if using
AA Base) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
SC-47.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
(Optional) One or
more layers, any
combination, loose
laid
Min. 2-inch H-Shield WF
OMG AccuTrac Plate or OMG 3 in. Ribbed Galvalume Plate
with #12 Roofgrip (steel only) or OMG #14 Heavy Duty,
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP
(steel only) or Dekfast #14, Trufast 3” Metal Insulation Plate
with Trufast #12 DP (steel only) or Trufast #14 HD
1 per 4
ft2
(Optional if
using AA Ply)
BP-AA, SBS-
AA
(Optional if using
AA Base) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
SC-48.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
(Optional) One or
more layers, any
combination, loose
laid
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board OMG 3-inch Galvalume Steel Plate with OMG #14 HD 1 per
1.78 ft2
(Optional if
using AA Ply)
BP-AA, SBS-
AA
(Optional if using
AA Base) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-75.0
SC-49.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
One or more layers,
any combination,
loose laid
Min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation or min.
0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12
(steel only) or #14 or Trufast 3” Metal Insulation Plate with
Trufast DP (steel only) or HD
1 per
1.33 ft2
(Optional if
using AA Ply)
BP-AA, SBS-
AA
(Optional if using
AA Base) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-82.5
COLD-APPLIED BASE:
SC-50.
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structrual
concrete
(Optional for recover)
One or more layers,
any combination,
loose laid
Min. 0.25-inch Dens Deck
Prime or SECUROCK
Gypsum-Fiber Roof Board
Dekfast Galvalume Steel Hex with Dekfast #14, OMG 3”
Galvalume Ribbed Plates with OMG #14 RoofGrip or Trufast
3” Metal Insulation Plates with Trufast #14 HD Fasteners
1 per 2
ft2
SBS-CA1, SBS-
CA2
(Optional) SBS-CA1,
SBS-CA2
SBS-CA1,
SBS-CA2,
APP-CA1
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 29 of 58
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
NOTE: INSULATION IS OPTIONAL FOR RECOVER APPLICATIONS
System
No.
Deck
(Note 1)
Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Attach Type Fasten Attach Base Ply Cap Ply
SC-51.
Min. 22 ga., type B, 40 ksi
steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached
Elastoflex S6 (film
surfaced) Trufast #14 HD with Trufast 2” Barbed Seam Plates
18-inch o.c. within the 4-inch
wide, torch-sealed or heat-
welded side laps
(Optional) SBS-
TA SBS-TA -30.0
SC-52.
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached
Polyglass HT Base
650
Trufast #15 EHD (steel only) or Trufast #14 HD
(concrete only) with Trufast 2.4” Barbed Metal Seam
Plates, Trufast 2.4” Scoop Seam Plates or Trufast
2.75” Barbed Metal Seam Plates or Dekfast #15 with
Dekfast Galvalume Steel 1-1/2” x 2-3/4” Oval Barbed
Plate (aka, Dekfast PLT-O2-3/4-12B) or Dekfast
Galvalume Steel 2-3/8” Round Barbed Plate (aka,
Dekfast PLT-R-2-3/8-6B)
18-inch o.c. within the 5-inch
wide, torch-sealed or heat-
welded side laps
(Optional) SBS-
TA SBS-TA -37.5
SC-53.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached
Elastobase,
Elastobase P or JM
Perma-Ply 28
Roofgrip #14 with OMG Flat Bottom Plates (square),
Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) or Trufast #14 HD with Trufast 3” Metal
Insulation Plate
12-inch o.c. at 4-inch lap and
18-inch o.c. at two, equally
spaced, staggered center rows
(Optional) BP-
AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA, APP-TA -45.0*
SC-54.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Loose
laid Elastobase Trufast #12 DP (steel only), #14 HD or #15 EHD with
Trufast 3” Metal Insulation Plate
12-inch o.c. at 4-inch lap and
12-inch o.c. at one staggered
center row
(Optional) SBS-
CA1, SBS-CA2
SBS-CA1, SBS-
CA2, APP-CA1 -45.0*
SC-55.
Min. 22 ga., type B, 33 ksi
steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached Elastoflex S6
Trufast #15 EHD (steel only) or Trufast #14 HD
(concrete only) with Trufast 2.4” Scoop Seam Plates
or Trufast 2.75” Barbed Metal Seam Plates
12-inch o.c. within the 5-inch
wide, torch-sealed or heat-
welded side laps
(Optional) SBS-
TA SBS-TA -45.0
SC-56.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached
Elastobase,
Elastobase P,
Polyglass G2 Base,
CertainTeed
Glasbase, Firestone
MB Base, JM Perma-
Ply 28, Tamko Glass
Base or GAFGLAS #75
Roofgrip #14 with OMG Flat Bottom Plates (square),
Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) or Trufast #14 HD with Trufast 3” Metal
Insulation Plate
12-inch o.c. at 4-inch lap and
12-inch o.c. at two, equally
spaced, staggered center rows
(Optional) BP-
AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA, APP-TA -52.5
SC-57.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached
Elastobase or
Elastobase P with
poly top surface
Roofgrip #14 with OMG Flat Bottom Plates (square),
Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) or Trufast #14 HD with Trufast 3” Metal
Insulation Plate
12-inch o.c. at 4-inch lap and
12-inch o.c. at two, equally
spaced, staggered center rows
SBS-SA
SBS-SA, APP-
SA, SBS-TA or
APP-TA
-52.5*
SC-58.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached
Elastobase or
Elastobase P with
poly top surface
Roofgrip #14 with OMG Flat Bottom Plates (square),
Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) or Trufast #14 HD with Trufast 3” Metal
Insulation Plate
12-inch o.c. at 4-inch lap and
12-inch o.c. at two, equally
spaced, staggered center rows
Polyflex SA
Base APP-TA -52.5*
SC-59.
Min. 22 ga., type B, 33 ksi
steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached Elastoflex S6
Trufast #15 EHD (steel only) or Trufast #14 HD
(concrete only) with Trufast 2.75” Barbed Metal Seam
Plates
6-inch o.c. within the 5-inch
wide, torch-sealed or heat-
welded side laps
(Optional) SBS-
TA SBS-TA -60.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 30 of 58
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
NOTE: INSULATION IS OPTIONAL FOR RECOVER APPLICATIONS
System
No.
Deck
(Note 1)
Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Attach Type Fasten Attach Base Ply Cap Ply
SC-60.
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached Elastoflex S6 Type II
Trufast #15 EHD (steel only) or Trufast #14 HD
(concrete only) with Trufast 2.75” Barbed Metal Seam
Plates
18-inch o.c. within the 5-inch
wide, torch-sealed or heat-
welded side laps
(Optional) SBS-
TA
SBS-TA
(D6164 only) -60.0
SC-61.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached
Elastobase or
Elastobase P
Roofgrip #12 (steel only) or #14 with OMG Flat
Bottom Plates (square)
12-inch o.c. at 4-inch lap and
12-inch o.c. at two, equally
spaced, staggered center rows
(Optional) BP-
AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA, APP-TA -60.0
SC-62.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached
Elastobase or
Elastobase P with
poly top surface
Roofgrip #12 (steel only) or #14 with OMG Flat
Bottom Plates (square)
12-inch o.c. at 4-inch lap and
12-inch o.c. at two, equally
spaced, staggered center rows
SBS-SA
SBS-SA, APP-
SA, SBS-TA or
APP-TA
-60.0*
SC-63.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached
Elastobase or
Elastobase P with
poly top surface
Roofgrip #12 (steel only) or #14 with OMG Flat
Bottom Plates (square)
12-inch o.c. at 4-inch lap and
12-inch o.c. at two, equally
spaced, staggered center rows
Polyflex SA
Base APP-TA -60.0*
SC-64.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Loose
laid Elastobase Trufast #12 DP (steel only), #14 HD or #15 EHD with
Trufast 3” Metal Insulation Plate
12-inch o.c. at 4-inch lap and
12-inch o.c. at two, equally
spaced, staggered center rows
(Optional) SBS-
CA1, SBS-CA2
SBS-CA1, SBS-
CA2, APP-CA1 -67.5
SC-65.
Min. 22 ga., type B, 33 ksi
steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached Elastoflex S6 Type II
Trufast #15 EHD (steel only) or Trufast #14 HD
(concrete only) with Trufast 2.75” Barbed Metal Seam
Plates
12-inch o.c. within the 5-inch
wide, torch-sealed or heat-
welded side laps
(Optional) SBS-
TA
SBS-TA
(D6164 only) -82.5
SC-66.
Min. 22 ga., type B, 33 ksi
steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached
Polyglass HT Base
650
Trufast #15 EHD (steel only) or Trufast #14 HD
(concrete only) with Trufast 2.4” Barbed Metal Seam
Plates, Trufast 2.4” Scoop Seam Plates or Trufast
2.75” Barbed Metal Seam Plates or Dekfast #15 with
Dekfast Galvalume Steel 1-1/2” x 2-3/4” Oval Barbed
Plate (aka, Dekfast PLT-O2-3/4-12B) or Dekfast
Galvalume Steel 2-3/8” Round Barbed Plate (aka,
Dekfast PLT-R-2-3/8-6B)
12-inch o.c. within the 5-inch
wide, torch-sealed or heat-
welded side laps
(Optional) SBS-
TA
SBS-TA
(D6164 only) -82.5
SC-67. Min. 22 ga., type B, Grade
80 steel
One or more
layers, any
combination
Prelim.
Attached Polyflex Dekfast #15 HS with Dekfast Galvalume Steel 2-3/8”
Round Barbed Plate (aka, Dekfast PLT-R-2-3/8-6B)
12-inch o.c. within the 5-inch
wide, torch-sealed side lap
(Optional) APP-
TA
SBS-TA, APP-
TA -82.5
SC-68.
Min. 22 ga., type B, Grade
80 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached Polybond or Polyflex
Trufast #15 EHD (steel only) or Trufast #14 HD
(concrete only) with Trufast 2.4 in. Barbed Seam
Plates
12-inch o.c. within the 6-inch
wide, torch-sealed side lap
(Optional) APP-
TA
SBS-TA, APP-
TA -82.5
SC-69.
Min. 22 ga., type B, 40 ksi
steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached Elastoflex S6 Type II
Trufast #15 EHD (steel only) or Trufast #14 HD
(concrete only) with Trufast 2.75” Barbed Metal Seam
Plates
6-inch o.c. within the 5-inch
wide, torch-sealed or heat-
welded side laps
(Optional) SBS-
TA
SBS-TA
(D6164 only) -97.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 31 of 58
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
NOTE: INSULATION IS OPTIONAL FOR RECOVER APPLICATIONS
System
No.
Deck
(Note 1)
Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Attach Type Fasten Attach Base Ply Cap Ply
SC-70.
Min. 22 ga., type B, 40 ksi
steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached
Polyglass HT Base
650
Trufast #15 EHD (steel only) or Trufast #14 HD
(concrete only) with Trufast 2.4” Barbed Metal Seam
Plates, Trufast 2.4” Scoop Seam Plates or Trufast
2.75” Barbed Metal Seam Plates or Dekfast #15 with
Dekfast Galvalume Steel 1-1/2” x 2-3/4” Oval Barbed
Plate (aka, Dekfast PLT-O2-3/4-12B) or Dekfast
Galvalume Steel 2-3/8” Round Barbed Plate (aka,
Dekfast PLT-R-2-3/8-6B)
6-inch o.c. within the 5-inch
wide, torch-sealed or heat-
welded side laps
(Optional) SBS-
TA
SBS-TA
(D6164 only) -97.5
SC-71.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached Polybond, Polyflex Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-
7/8) or OMG Roofgrip #14 OMG Flat Bottom Plates
12-inch o.c. at the 4-inch lap
and 18-inch o.c. at two, equally
spaced, staggered center rows
(Optional) BP-
AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA, APP-TA -112.5
SC-72.
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached Elastoflex S6 Type II
Trufast #15 EHD (steel only) or Trufast #14 HD
(concrete only) with Trufast 2.75” Barbed Metal Seam
Plates
6-inch o.c. within the 5-inch
wide, torch-sealed or heat-
welded side laps
(Optional) SBS-
TA
SBS-TA
(D6164 only) -135.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 32 of 58
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 18
System
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
SELF-ADHERING BASE WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE:
C-1 Structural
concrete
(Optional)
PG100 Min. 1.5-inch H-Shield or Multi-Max FA3 D-IS (Optional) additional layers(s) of
base insulation D-IS SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -67.5
C-2 Structural
concrete
(Optional)
PG100 Min. 1.5-inch H-Shield or Multi-Max FA3 D-IS (Optional) additional layers(s) of
base insulation D-IS Polyflex SA
Base (Optional) APP-TA APP-TA -67.5
C-3 Structural
concrete None Min. 1.5-inch Polytherm H, H-Shield D-IS (Optional) additional layers(s) of
base insulation D-IS
SBS-SA or
Polyflex SA
Base
(Optional) SBS-TA, APP-TA SBS-TA, APP-TA -122.5
C-4 Structural
concrete
(Optional)
PG100 Min. 1.5-inch Polytherm, ACFoam II or ENRGY 3 D-IS (Optional) additional layers(s) of
base insulation D-IS SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -135.0
C-5 Structural
concrete
(Optional)
PG100 Min. 1.5-inch Polytherm, ACFoam II or ENRGY 3 D-IS (Optional) additional layers(s) of
base insulation D-IS Polyflex SA
Base (Optional) APP-TA APP-TA -135.0
C-6 Structural
concrete None Min. 1.5-inch, min. 1.5 pcf Insulfoam D-IS (Optional) additional layers of
base insulation D-IS SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -157.5
C-7 Structural
concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, Polytherm H or H-Shield D-IS
(Optional) additional layers of
base insulation
PRIMER: PG100
D-IS
Polyflex SA
Base primed
with PG100
None SBS-SA, APP-SA -170.0
C-8 Structural
concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 (Optional) additional layers of
base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -120.0
C-9 Structural
concrete None Min. 1.5-inch Polytherm, ACFoam II OB500 (Optional) additional layers(s) of
base insulation OB500
SBS-SA or
Polyflex SA
Base
(Optional) SBS-TA, APP-TA SBS-TA, APP-TA -122.5
C-10 Structural
concrete None Min. 1.5-inch ENRGY 3 OB500 (Optional) additional layers(s) of
base insulation OB500 SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -127.5
C-11 Structural
concrete None Min. 1.5-inch ENRGY 3 OB500 (Optional) additional layers(s) of
base insulation OB500 Polyflex SA
Base (Optional) APP-TA APP-TA -127.5
C-12 Structural
concrete None Min. 1.5-inch Polytherm H or H-Shield OB500 (Optional) additional layers(s) of
base insulation OB500 SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -150.0
C-13 Structural
concrete None Min. 1.5-inch Polytherm H or H-Shield OB500 (Optional) additional layers(s) of
base insulation OB500 Polyflex SA
Base (Optional) APP-TA APP-TA -150.0
C-14 Structural
concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, Polytherm H or H-Shield OB500
(Optional) additional layers of
base insulation
PRIMER: PG100
OB500
Polyflex SA
Base primed
with PG100
None SBS-SA, APP-SA -170.0
C-15 Structural
concrete None Min. 1.5-inch Polytherm, ACFoam II, Polytherm
G, ACFoam III, Polytherm H, H-Shield
M-OSFA or
M-PG1
(Optional) additional layers(s) of
base insulation
M-OSFA or
M-PG1
SBS-SA or
Polyflex SA
Base
(Optional) SBS-TA, APP-TA SBS-TA, APP-TA -122.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 33 of 58
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 18
System
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
C-16 Structural
concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, Polytherm H or H-Shield
M-OSFA or
M-PG1
(Optional) additional layers of
base insulation
PRIMER: PG100
M-OSFA or
M-PG1
Polyflex SA
Base primed
with PG100
None SBS-SA, APP-SA -170.0
C-17 Structural
concrete None Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3,
H-Shield or Multi-Max FA3 M-OSFA (Optional) additional layers(s) of
base insulation M-OSFA SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -232.5
C-18 Structural
concrete None Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3,
H-Shield or Multi-Max FA3 M-OSFA (Optional) additional layers(s) of
base insulation M-OSFA Polyflex SA
Base (Optional) APP-TA APP-TA -232.5
C-19 Structural
concrete None
Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, EnergyGuard Polyiso Insulation,
ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL,
Multi-Max FA3, RESISTA or UltraMax.
M-OSFA or
M-PG1
(Optional) additional layers(s) of
base insulation, optionally
primed with WB-3000
M-OSFA or
M-PG1 SBS-SA None SBS-CA1, SBS-
CA2 -290.0
C-20 Structural
concrete None Min. 1.5-inch Polytherm, ACFoam II, Polytherm
H, H-Shield CR-20 (Optional) additional layers(s) of
base insulation CR-20
SBS-SA or
Polyflex SA
Base
(Optional) SBS-TA, APP-TA SBS-TA, APP-TA -122.5
C-21 Structural
concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, Polytherm H or H-Shield CR-20
(Optional) additional layers of
base insulation
PRIMER: PG100
CR-20
Polyflex SA
Base primed
with PG100
None SBS-SA, APP-SA -170.0
C-22 Structural
concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 (Optional) additional layers of
base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -240.0
C-23 Structural
concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H
or H-Shield
OB Classic
(full-
coverage)
(Optional) additional layers(s) of
base insulation
OB Classic
(full-
coverage)
SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -270.0
C-24 Structural
concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H
or H-Shield
OB Classic
(full-
coverage)
(Optional) additional layers(s) of
base insulation
OB Classic
(full-
coverage)
Polyflex SA
Base (Optional) APP-TA APP-TA -270.0
C-25 Structural
concrete PG100
Min. 1.5-inch Polytherm, ACFoam II, Polytherm
G, ACFoam III, ENRGY 3, Polytherm H, H-Shield,
H-Shield CG or Multi-Max FA3
Hot
asphalt
(Optional) additional layers(s) of
base insulation
Hot
asphalt SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -480.0
C-26 Structural
concrete PG100
Min. 1.5-inch Polytherm, ACFoam II, Polytherm
G, ACFoam III, ENRGY 3, Polytherm H, H-Shield,
H-Shield CG or Multi-Max FA3
Hot
asphalt
(Optional) additional layers(s) of
base insulation
Hot
asphalt
Polyflex SA
Base (Optional) APP-TA APP-TA -480.0
SELF-ADHERING BASE WITH BASE INSULATION AND COVERBOARD:
C-27 Structural
concrete None Min. 1.5-inch Multi-Max FA3 D-IS
Min. 0.25-inch Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof
Board
D-IS SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -67.5
C-28 Structural
concrete None Min. 1.5-inch Multi-Max FA3 D-IS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board D-IS Polyflex SA
Base (Optional) APP-TA APP-TA -67.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 34 of 58
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 18
System
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
C-29 Structural
concrete None
Min. 1.5-inch, min. 2.0 pcf Insulfoam,
Polytherm, ACFoam II, ENRGY 3, Polytherm H or
H-Shield
D-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5
C-30 Structural
concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch Dens Deck, Dens
Deck Prime D-IS SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -120.0
C-31 Structural
concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch Dens Deck, Dens
Deck Prime D-IS Polyflex SA
Base (Optional) APP-TA APP-TA -120.0
C-32 Structural
concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, Polytherm H or H-Shield D-IS
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Mat Roof Board
or SECUROCK Gypsum-Fiber Roof
Board
PRIMER: PG100
D-IS
Polyflex SA
Base primed
with PG100
None SBS-SA, APP-SA -172.5
C-33 Structural
concrete None Min. 2-inch Polytherm, ACFoam II, ENRGY-3,
Polytherm H or H-Shield D-IS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board D-IS SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -247.5
C-34 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield D-IS Min. 0.25-inch Dens Deck Prime
optionally primed with WB-3000 D-IS SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -282.5
C-35 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield D-IS
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board or
DEXcell FA Glass Mat Roof Board
optionally primed with WB-3000
D-IS
SBS-SA or
Polyflex SA
Base
(Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5
C-36 Structural
concrete None Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3,
H-Shield or ISO 95+GL OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5
C-37 Structural
concrete None Min. 1.5-inch ENRGY 3 OB500 Min. 0.25-inch Dens Deck, Dens
Deck Prime OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -127.5
C-38 Structural
concrete None Min. 1.5-inch ENRGY 3 OB500 Min. 0.25-inch Dens Deck, Dens
Deck Prime OB500 Polyflex SA
Base (Optional) APP-TA APP-TA -127.5
C-39 Structural
concrete None Min. 1.5-inch Polytherm, ACFoam II, H-Shield or
ISO 95+GL OB500 Min. 0.25-inch Dens Deck, Dens
Deck Prime OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -150.0
C-40 Structural
concrete None Min. 1.5-inch Polytherm, ACFoam II, H-Shield or
ISO 95+GL OB500 Min. 0.25-inch Dens Deck, Dens
Deck Prime OB500 Polyflex SA
Base (Optional) APP-TA APP-TA -150.0
C-41 Structural
concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, Polytherm H or H-Shield OB500
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Mat Roof Board
or SECUROCK Gypsum-Fiber Roof
Board
PRIMER: PG100
OB500
Polyflex SA
Base primed
with PG100
None SBS-SA, APP-SA -172.5
C-42 Structural
concrete None Min. 2-inch Polytherm, ACFoam II, ENRGY-3,
Polytherm H or H-Shield OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -247.5
C-43 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -282.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 35 of 58
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 18
System
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
C-44 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield OB500
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board or
DEXcell FA Glass Mat Roof Board
OB500
SBS-SA or
Polyflex SA
Base
(Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5
C-45 Structural
concrete None Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3,
H-Shield or Multi-Max FA3 M-OSFA Min. 0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5
C-46 Structural
concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, Polytherm H or H-Shield
M-OSFA or
M-PG1
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Mat Roof Board
or SECUROCK Gypsum-Fiber Roof
Board
PRIMER: PG100
M-OSFA or
M-PG1
Polyflex SA
Base primed
with PG100
None SBS-SA, APP-SA -172.5
C-47 Structural
concrete None Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3,
H-Shield or Multi-Max FA3 M-OSFA Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -232.5
C-48 Structural
concrete None Min. 2-inch Polytherm, ACFoam II, ENRGY-3,
Polytherm H or H-Shield M-OSFA Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -247.5
C-49 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield
M-OSFA or
M-PG1 Min. 0.25-inch Dens Deck Prime M-OSFA or
M-PG1 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -282.5
C-50 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield
M-OSFA or
M-PG1
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board or
DEXcell FA Glass Mat Roof Board
M-OSFA or
M-PG1
SBS-SA or
Polyflex SA
Base
(Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5
C-51 Structural
concrete None
Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 2-
inch Polytherm, ACFoam II, min. 1.5-inch Ultra-
Max or Multi-Max FA-3, min. 1.3-inch
Polytherm G, ACFoam III or min. 1.0-inch ISO
95+GL, Polytherm H, H-Shield, H-Shield CG or
ENRGY 3
CR-20 Min. 0.25-inch Dens Deck, Dens
Deck Prime CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5
C-52 Structural
concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, Polytherm H or H-Shield CR-20
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Mat Roof Board
or SECUROCK Gypsum-Fiber Roof
Board
PRIMER: PG100
CR-20
Polyflex SA
Base primed
with PG100
None SBS-SA, APP-SA -172.5
C-53 Structural
concrete None
Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 1.5-
inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch
Polytherm G, ACFoam III or min. 1.0-inch ISO
95+GL, Polytherm H, H-Shield, H-Shield CG or
ENRGY 3
CR-20 Min. 0.25-inch Dens Deck, Dens
Deck Prime CR-20 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -240.0
C-54 Structural
concrete None
Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 1.5-
inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch
Polytherm G, ACFoam III or min. 1.0-inch ISO
95+GL, Polytherm H, H-Shield, H-Shield CG or
ENRGY 3
CR-20 Min. 0.25-inch Dens Deck, Dens
Deck Prime CR-20 Polyflex SA
Base (Optional) APP-TA APP-TA -240.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 36 of 58
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 18
System
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
C-55 Structural
concrete None
Min. 1.5-inch Ultra-Max or Multi-Max FA-3,
min. 1.3-inch Polytherm G, ACFoam III or min.
1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-
Shield CG or ENRGY 3
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -240.0
C-56 Structural
concrete None
Min. 1.5-inch Ultra-Max or Multi-Max FA-3,
min. 1.3-inch Polytherm G, ACFoam III or min.
1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-
Shield CG or ENRGY 3
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 Polyflex SA
Base (Optional) APP-TA APP-TA -240.0
C-57 Structural
concrete None Min. 2-inch Polytherm, ACFoam II, ENRGY-3,
Polytherm H or H-Shield CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -247.5
C-58 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -282.5
C-59 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield CR-20
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board or
DEXcell FA Glass Mat Roof Board
CR-20
SBS-SA or
Polyflex SA
Base
(Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5
C-60 Structural
concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H
or H-Shield
OB Classic
(full-
coverage)
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
OB Classic
(full-
coverage)
SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -350.0
C-61 Structural
concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H
or H-Shield
OB Classic
(full-
coverage)
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
OB Classic
(full-
coverage)
Polyflex SA
Base (Optional) APP-TA APP-TA -350.0
C-62 Structural
concrete PG100
Min. 1.5-inch Polytherm, ACFoam II, Polytherm
G, ACFoam III, ENRGY 3, Polytherm H, H-Shield,
H-Shield CG or Multi-Max FA3
Hot
asphalt
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -350.0
C-63 Structural
concrete PG100
Min. 1.5-inch Polytherm, ACFoam II, Polytherm
G, ACFoam III, ENRGY 3, Polytherm H, H-Shield,
H-Shield CG or Multi-Max FA3
Hot
asphalt
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
Polyflex SA
Base (Optional) APP-TA APP-TA -350.0
ASPHALT OR TORCH APPLIED BASE:
C-64 Structural
concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H
or H-Shield D-IS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board D-IS BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0
C-65 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield D-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -282.5
C-66 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield D-IS
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board or
DEXcell FA Glass Mat Roof Board
D-IS SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5
C-67 Structural
concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H
or H-Shield OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0
C-68 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -282.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 37 of 58
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 18
System
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
C-69 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield OB500
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board or
DEXcell FA Glass Mat Roof Board
OB500 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5
C-70 Structural
concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H
or H-Shield
M-OSFA or
M-PG1
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
M-OSFA or
M-PG1 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0
C-71 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield
M-OSFA or
M-PG1 Min. 0.25-inch Dens Deck Prime M-OSFA or
M-PG1 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -282.5
C-72 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield
M-OSFA or
M-PG1
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board or
DEXcell FA Glass Mat Roof Board
M-OSFA or
M-PG1 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5
C-73 Structural
concrete None
Min. 1.5-inch Ultra-Max or Multi-Max FA-3,
min. 1.3-inch Polytherm G, ACFoam III or min.
1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-
Shield CG or ENRGY 3
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0
C-74 Structural
concrete None
Min. 1.5-inch Ultra-Max or Multi-Max FA-3,
min. 1.3-inch Polytherm G, ACFoam III or min.
1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-
Shield CG or ENRGY 3
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 APP-TA (Optional) APP-TA APP-TA -232.5
C-75 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -282.5
C-76 Structural
concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, Polytherm H, H-Shield CR-20
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board or
DEXcell FA Glass Mat Roof Board
CR-20 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5
C-77 Structural
concrete None (Optional) Min. 2-inch Polytherm, ACFoam II,
Polytherm H or H-Shield
OB Classic
(full-
coverage)
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
OB Classic
(full-
coverage)
BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0
C-78 Structural
concrete None (Optional) Min. 2-inch Polytherm, ACFoam II,
Polytherm H or H-Shield
OB Classic
(full-
coverage)
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
OB Classic
(full-
coverage)
APP-TA (Optional) APP-TA APP-TA -232.5
C-79 Structural
concrete PG100
Min. 1.5-inch Polytherm, ACFoam II, Polytherm
G, ACFoam III, ENRGY 3, Polytherm H, H-Shield,
H-Shield CG or Multi-Max FA3
Hot
asphalt
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0
C-80 Structural
concrete PG100
Min. 1.5-inch Polytherm, ACFoam II, Polytherm
G, ACFoam III, ENRGY 3, Polytherm H, H-Shield,
H-Shield CG or Multi-Max FA3
Hot
asphalt
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt APP-TA (Optional) APP-TA APP-TA -232.5
C-81 Structural
concrete PG100 Min. 0.75-inch Fesco Board (homogeneous) Hot
asphalt None N/A
(Optional if
using AA Ply)
BP-AA, SBS-AA
(Optional if using AA Base)
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-TA,
APP-TA -277.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 38 of 58
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 18
System
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
C-82 Structural
concrete PG100
Min. 1.5-inch Polytherm, ACFoam II, Polytherm
G, ACFoam III, ENRGY 3, Polytherm H, H-Shield,
H-Shield CG or Multi-Max FA3
Hot
asphalt
Min. 0.75-inch Fesco Board
(homogeneous)
Hot
asphalt
(Optional if
using AA Ply)
BP-AA, SBS-AA
(Optional if using AA Base)
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-TA,
APP-TA -290.0
C-83 Structural
concrete PG100 Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
Hot
asphalt None N/A
(Optional if
using AA Ply)
BP-AA, SBS-AA
(Optional if using AA Base)
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-TA,
APP-TA -285.0
C-84 Structural
concrete PG100
Min. 1.5-inch Polytherm, ACFoam II, Polytherm
G, ACFoam III, ENRGY 3, Polytherm H, H-Shield,
H-Shield CG or Multi-Max FA3
Hot
asphalt
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
Hot
asphalt
(Optional if
using AA Ply)
BP-AA, SBS-AA
(Optional if using AA Base)
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-TA,
APP-TA -480.0
C-85 Structural
concrete PG100
Min. 1.5-inch Polytherm, ACFoam II, Polytherm
G, ACFoam III, ENRGY 3, Polytherm H, H-Shield,
H-Shield CG or Multi-Max FA3
Hot
asphalt Min. 0.25-inch Dens Deck Prime Hot
asphalt
(Optional if
using AA Ply)
BP-AA, SBS-AA
(Optional if using AA Base)
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-TA,
APP-TA -480.0
C-86 Structural
concrete PG100 Min. 0.25-inch Dens Deck Prime Hot
asphalt None N/A
(Optional if
using AA Ply)
BP-AA, SBS-AA
(Optional if using AA Base)
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-TA,
APP-TA -510.0
COLD-APPLIED BASE:
C-87 Structural
concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, ENRGY 3, Polytherm H or H-Shield D-IS
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Mat Roof Board
or SECUROCK Gypsum-Fiber Roof
Board
D-IS SBS-CA1, SBS-
CA2
(Optional) SBS-CA1, SBS-
CA2
SBS-CA1, SBS-
CA2, APP-CA1 -120.0
C-88 Structural
concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, Polytherm H or H-Shield D-IS
Min. 0.25-inch Dens Deck Prime
or DEXcell FA Glass Mat Roof
Board
D-IS SBS-CA1 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
C-89 Structural
concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, Polytherm H or H-Shield D-IS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board D-IS SBS-CA1, SBS-
CA2 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
C-90 Structural
concrete None Min. 1-inch ENRGY 3, Polytherm H or H-Shield D-IS
Min. 0.25-inch Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof
Board
D-IS SBS-CA1, SBS-
CA2 None SBS-CA1, SBS-
CA2 -232.5
C-91 Structural
concrete None
Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, EnergyGuard Polyiso Insulation,
ENRGY 3, Polytherm H, H-Shield ISO 95+ GL,
Multi-Max FA3, RESISTA or UltraMax or min. 2-
inch DECKMATE Plus or DECKMATE Plus FA
M-OSFA,
M-PG1
Min. 0.25-inch Dens Deck, Dens
Deck Prime, DEXcell FA Glass
Mat Roof Board, SECUROCK
Gypsum-Fiber Roof Board or
SECUROCK Glass-Mat Roof
Board, min. 7/16-inch DEXcell
Cement Roof Board or min. 0.5-
inch SECUROCK Cement Roof
Board
M-OSFA or
M-PG1
SBS-CA1, SBS-
CA2
(Optional) SBS-CA1, SBS-
CA2
SBS-CA1, SBS-
CA2, APP-CA1 -120.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 39 of 58
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 18
System
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
C-92 Structural
concrete None
Min. 1-inch Polytherm or ACFoam II, Polytherm
G, ACFoam III, EnergyGuard Polyiso Insulation,
ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL,
Multi-Max FA3, RESISTA or UltraMax or min. 2-
inch DECKMATE Plus or DECKMATE Plus FA
M-OSFA,
M-PG1
Min. 0.25-inch Dens Deck Prime
or DEXcell FA Glass Mat Roof
Board, min. 7/16-inch DEXcell
Cement Roof Board or min. 0.5-
inch SECUROCK Cement Roof
Board
M-OSFA,
M-PG1 SBS-CA1 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
C-93 Structural
concrete None
Min. 1-inch Polytherm or ACFoam II, Polytherm
G, ACFoam III, EnergyGuard Polyiso Insulation,
ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL,
Multi-Max FA3, RESISTA or UltraMax or min. 2-
inch DECKMATE Plus or DECKMATE Plus FA
M-OSFA,
M-PG1
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
M-OSFA,
M-PG1
SBS-CA1, SBS-
CA2 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
C-94 Structural
concrete None
Min. 1-inch Polytherm or ACFoam II, Polytherm
G, ACFoam III, EnergyGuard Polyiso Insulation,
ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL,
Multi-Max FA3, RESISTA or UltraMax or min. 2-
inch DECKMATE Plus or DECKMATE Plus FA
M-OSFA,
M-PG1
Min. 0.25-inch Dens Deck, Dens
Deck Prime, DEXcell FA Glass
Mat Roof Board, SECUROCK
Gypsum-Fiber Roof Board or
SECUROCK Glass-Mat Roof
Board, min. 7/16-inch DEXcell
Cement Roof Board or min. 0.5-
inch SECUROCK Cement Roof
Board
M-OSFA,
M-PG1
SBS-CA1, SBS-
CA2 None SBS-CA1, SBS-
CA2 -232.5
C-95 Structural
concrete None
Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, ENRGY 3, Polytherm H, H-Shield or
Multi-Max FA3
OB500
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Mat Roof Board
or SECUROCK Gypsum-Fiber Roof
Board
OB500 SBS-CA1, SBS-
CA2
(Optional) SBS-CA1, SBS-
CA2
SBS-CA1, SBS-
CA2, APP-CA1 -120.0
C-96 Structural
concrete None
Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, ENRGY 3, Polytherm H, H-Shield or
Multi-Max FA3
OB500
Min. 0.25-inch Dens Deck Prime
or DEXcell FA Glass Mat Roof
Board
OB500 SBS-CA1 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
C-97 Structural
concrete None
Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, ENRGY 3, Polytherm H, H-Shield or
Multi-Max FA3
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS-
CA2 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
C-98 Structural
concrete None Min. 1-inch Polytherm, ACFoam II, ENRGY 3 or
Multi-Max FA3 OB500
Min. 0.25-inch Dens Deck Prime,
DEXcell FA Glass Mat Roof Board
or SECUROCK Gypsum-Fiber Roof
Board
OB500 SBS-CA1, SBS-
CA2 None SBS-CA1, SBS-
CA2 -232.5
C-99 Structural
concrete None
Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, ENRGY 3, Polytherm H, H-Shield or
Multi-Max FA3
CR-20
Min. 0.25-inch Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof
Board
CR-20 SBS-CA1, SBS-
CA2
(Optional) SBS-CA1, SBS-
CA2
SBS-CA1, SBS-
CA2, APP-CA1 -120.0
C-100 Structural
concrete None
Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, ENRGY 3, Polytherm H, H-Shield or
Multi-Max FA3
CR-20
Min. 0.25-inch Dens Deck Prime
or DEXcell FA Glass Mat Roof
Board
CR-20 SBS-CA1 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 40 of 58
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 18
System
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
C-101 Structural
concrete None
Min. 1-inch Polytherm, ACFoam II, Polytherm G,
ACFoam III, ENRGY 3, Polytherm H, H-Shield or
Multi-Max FA3
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-CA1, SBS-
CA2 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
C-102 Structural
concrete None Min. 1-inch ENRGY 3, Polytherm H, H-Shield,
Multi-Max FA3 CR-20
Min. 0.25-inch Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof
Board
CR-20 SBS-CA1, SBS-
CA2 None SBS-CA1, SBS-
CA2 -232.5
TABLE 3B: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply
C-103 Structural concrete None SBS-CA1 None SBS-CA1, SBS-CA2, APP-CA1 -105.0
C-104 Structural concrete PG100 Polyflex SA Base primed with PG100 None SBS-SA, APP-SA -117.5
C-105 Structural concrete PG100 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -315.0
C-106 Structural concrete PG100 Polyflex SA Base (Optional) APP-TA APP-TA -315.0
C-107 Structural concrete PG100 (Optional) SBS-TA (Optional) SBS-TA SBS-TA -495.0
C-108 Structural concrete PG100 BP-AA (Optional if using asphalt applied Ply) (Optional if using asphalt applied Base) BP-AA, SBS-
AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -622.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 41 of 58
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight
Concrete (Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
SELF-ADHERING BASE WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE:
LWC-1 Structural
concrete
Min. 200 psi, min
2-inch Elastizell Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 (Optional) Additional layers
of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -120.0
LWC-2 Structural
concrete
Min. 200 psi, min
2-inch Elastizell
Min. 1.5-inch Polytherm, ACFoam II, ENRGY
3, ISO 95+ GL, Polytherm H or H-Shield OB500 (Optional) Additional layers
of base insulation OB500 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -225.0
LWC-3 Structural
concrete
Min. 200 psi, min
2-inch Elastizell
Min. 1.5-inch Polytherm, ACFoam II, ENRGY
3, ISO 95+ GL, Polytherm H or H-Shield OB500 (Optional) Additional layers
of base insulation OB500 Polyflex SA
Base (Optional) APP-TA APP-TA -225.0
LWC-4 Structural
concrete
Min. 200 psi, min.
2-inch Elastizell Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 (Optional) Additional layers
of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -180.0
LWC-5 Structural
concrete
Min. 200 psi, min.
2-inch Elastizell
Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3, ISO 95+
GL, Polytherm H, H-Shield, H-Shield CG,
Multi-Max FA3
CR-20 (Optional) Additional layers
of base insulation CR-20 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -180.0
LWC-6 Structural
concrete
Min. 200 psi, min.
2-inch Elastizell
Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3, ISO 95+
GL, Polytherm H, H-Shield, H-Shield CG,
Multi-Max FA3
CR-20 (Optional) Additional layers
of base insulation CR-20 Polyflex SA
Base (Optional) APP-TA APP-TA -180.0
LWC-7 Structural
concrete
Min. 200 psi, min.
2-inch Celcore or
Mearlcrete
Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 (Optional) Additional layers
of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -222.5
LWC-8 Structural
concrete
Min. 200 psi, min.
2-inch Celcore or
Mearlcrete
Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3, ISO 95+
GL, Polytherm H, H-Shield, H-Shield CG,
Multi-Max FA3
CR-20 (Optional) Additional layers
of base insulation CR-20 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -222.5
LWC-9 Structural
concrete
Min. 200 psi, min.
2-inch Celcore or
Mearlcrete
Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3, ISO 95+
GL, Polytherm H, H-Shield, H-Shield CG,
Multi-Max FA3
CR-20 (Optional) Additional layers
of base insulation CR-20 Polyflex SA
Base (Optional) APP-TA APP-TA -222.5
SELF-ADHERING BASE WITH BASE INSULATION AND COVERBOARD:
LWC-10 Structural
concrete
Min. 200 psi, min
2-inch Elastizell Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -120.0
LWC-11 Structural
concrete
Min. 200 psi, min
2-inch Elastizell Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 Polyflex SA
Base (Optional) APP-TA APP-TA -120.0
LWC-12 Structural
concrete
Min. 200 psi, min
2-inch Elastizell
Min. 1.5-inch Polytherm, ACFoam II, ENRGY
3, ISO 95+ GL, Polytherm H or H-Shield OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -225.0
LWC-13 Structural
concrete
Min. 200 psi, min
2-inch Elastizell
Min. 1.5-inch Polytherm, ACFoam II, ENRGY
3, ISO 95+ GL, Polytherm H or H-Shield OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 Polyflex SA
Base (Optional) APP-TA APP-TA -225.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 42 of 58
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight
Concrete (Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
LWC-14 Structural
concrete
Min. 200 psi, min.
2-inch Elastizell
Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3, ISO 95+
GL, Polytherm H, H-Shield, H-Shield CG,
Multi-Max FA3 or min. 2.0 pcf Insulfoam
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -180.0
LWC-15 Structural
concrete
Min. 200 psi, min.
2-inch Elastizell
Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3, ISO 95+
GL, Polytherm H, H-Shield, H-Shield CG,
Multi-Max FA3 or min. 2.0 pcf Insulfoam
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 Polyflex SA
Base (Optional) APP-TA APP-TA -180.0
LWC-16 Structural
concrete
Min. 200 psi, min.
2-inch Celcore or
Mearlcrete
Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3, ISO 95+
GL, Polytherm H, H-Shield, H-Shield CG,
Multi-Max FA3 or min. 2.0 pcf Insulfoam
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -222.5
LWC-17 Structural
concrete
Min. 200 psi, min.
2-inch Celcore or
Mearlcrete
Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3, ISO 95+
GL, Polytherm H, H-Shield, H-Shield CG,
Multi-Max FA3 or min. 2.0 pcf Insulfoam
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 Polyflex SA
Base (Optional) APP-TA APP-TA -222.5
ASPHALT OR TORCH APPLIED BASE:
LWC-18 Structural
concrete
Min. 200 psi, min
2-inch Elastizell
Min. 1.5-inch Polytherm, ACFoam II, ENRGY
3, ISO 95+ GL, Polytherm H or H-Shield OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 BP-AA, SBS-
AA, APP-TA
(Optional) BP-AA, SBS-
AA, SBS-TA or APP-TA
SBS-AA, SBS-TA,
APP-TA -225.0
LWC-19 Structural
concrete
Min. 200 psi, min.
2-inch Elastizell
Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3, ISO 95+
GL, Polytherm H, H-Shield, H-Shield CG,
Multi-Max FA3 or min. 2.0 pcf Insulfoam
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 BP-AA, SBS-
AA, APP-TA
(Optional) BP-AA, SBS-
AA, SBS-TA or APP-TA
SBS-AA, SBS-TA,
APP-TA -180.0
LWC-20 Structural
concrete
Min. 200 psi, min.
2-inch Celcore or
Mearlcrete
Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3, ISO 95+
GL, Polytherm H, H-Shield, H-Shield CG,
Multi-Max FA3 or min. 2.0 pcf Insulfoam
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 BP-AA, SBS-
AA, APP-TA
(Optional) BP-AA, SBS-
AA, SBS-TA or APP-TA
SBS-AA, SBS-TA,
APP-TA -222.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 43 of 58
TABLE 4B: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No. Deck (Note 1)
Lightweight
Concrete
(Note 14)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap Ply
LWC-21
Min. 22 ga.,
Type B, vented
steel at max. 5 ft
spans
Min. 300 psi
Approved
cellular LWC
GAFGLAS
#75
OMG CR
BSF
7-inch o.c. at 4-
inch lap and 7-
inch o.c. in two,
equally spaced
center rows
(Optional) Min. 1.5-
inch Polytherm,
ACFoam II, Polytherm
H, H-Shield, Multi-
Max FA3 or
Polytherm
HA
Min. 1.5-inch Thermaroof
Composite, Polytherm
Composite, or min. 0.5-inch
Structodek High Density
Fiberboard Roof Insulation or
min. 0.75-inch Fesco Board
(homogeneous)
HA
(Optional if
using AA
Ply) BP-AA,
SBS-AA
(Optional if
using AA
Base) BP-AA,
SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
LWC-22
Min. 22 ga.,
Type B, vented
steel at max. 5 ft
spans
Min. 300 psi
Approved
cellular LWC
GAFGLAS
#75
OMG CR
BSF
7-inch o.c. at 4-
inch lap and 7-
inch o.c. in two,
equally spaced
center rows
Min. 1.5-inch
Polytherm, ACFoam
II, Polytherm H, H-
Shield, Multi-Max
FA3 or Polytherm
HA None N/A SBS-SA
(Optional)
SBS-SA, SBS-
TA, APP-TA
SBS-SA,
APP-SA,
SBS-TA,
APP-TA
-45.0
LWC-23
Min. 22 ga.,
Type B, vented
steel at max. 5 ft
spans
Min. 300 psi
Approved
cellular LWC
GAFGLAS
#75
OMG CR
BSF
7-inch o.c. at 4-
inch lap and 7-
inch o.c. in two,
equally spaced
center rows
Min. 1.5-inch
Polytherm, ACFoam
II, Polytherm H, H-
Shield, Multi-Max
FA3 or Polytherm
HA None N/A Polyflex SA
Base
(Optional)
APP-TA APP-TA -45.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 44 of 58
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet (Note A below) Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Cap Ply
‘GENERIC’ CELLULAR LIGHTWEIGHT INSULATING CONCRETE:
LWC-24 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
cellular LWC. Note: To qualify the
LWIC under this assembly, an OMG
CR BPF shall achieve an average
withdrawal of 53 lbf when tested per
TAS 105 or ANSI/SPRI FX-1
B3 OMG CR BPF
7-inch o.c. in a 3-inch lap and 7-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
(Optional) BP-
AA, SBS-AA
SBS-AA, APP-
TA -45.0
CELCORE CELLULAR LIGHTWEIGHT INSULATING CONCRETE:
LWC-25
Min. 0.0179-inch Tensilform S-75
or min. 0.0205-inch Tensilform
75 at max. 5 ft spans or
structural concrete
Min. 200 psi, min. 2-inch thick
Celcore B1, B2, B3 or B7 Trufast FM-90
or OMG CR BPF
8-inch o.c. in a 3-inch lap and 16-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
BP-AA, SBS-AA SBS-AA -37.5
LWC-26 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 200 psi, min. 2-inch thick
Celcore B1 through B12 Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 3-inch lap and 7-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
BP-AA, SBS-AA SBS-AA -45.0
LWC-27 Min. 26 ga., type HF steel at max
5 ft spans or structural concrete
Min. 225 psi, min. 2-inch thick
Celcore MF
B1, B2, B3, B4, B7,
B8, B10, B11 or
B12
OMG CR BPF
9-inch o.c. in a 3-inch lap and 9-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
BP-AA, SBS-AA SBS-AA -45.0
LWC-28 Min. 22 ga., type B steel at max 6
ft spans or structural concrete
Min. 225 psi, min. 2-inch thick
Celcore MF
B1, B2, B3, B4, B7,
B8, B10, B11 or
B12
OMG CR BPF
7-inch o.c. in a 3-inch lap and 14-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
BP-AA, SBS-AA SBS-AA -45.0
LWC-29 Min. 22 ga., type B steel at max 6
ft spans or structural concrete
Min. 225 psi, min. 2-inch thick
Celcore MF
B1, B2, B3, B4, B7,
B8, B10, B11 or
B12
OMG CR BPF
9-inch o.c. in a 3-inch lap and 9-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
BP-AA, SBS-AA SBS-AA -45.0
LWC-30 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 225 psi, min. 2-inch thick
Celcore MF B1 or B2 Trufast Twin
Loc-Nail
9-inch o.c. in a 4-inch lap and 18-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA, or APP-TA -45.0
LWC-31 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 225 psi, min. 2-inch thick
Celcore MF
B2 (with poly-film
top surface)
Trufast Twin
Loc-Nail
9-inch o.c. in a 4-inch lap and 18-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
SBS-SA, SBS-TA
or APP-TA
SBS-SA, APP-
SA, SBS-TA or
APP-TA
-45.0
LWC-32 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 225 psi, min. 2-inch thick
Celcore MF
B2 (with poly-film
top surface)
Trufast Twin
Loc-Nail
9-inch o.c. in a 4-inch lap and 18-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
Polyflex SA Base APP-TA -45.0
LWC-33 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Celcore MF B2 Trufast FM-90 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three
equally spaced, staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA, or APP-TA -60.0
LWC-34 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Celcore MF
B2 (with poly-film
top surface) Trufast FM-90 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three
equally spaced, staggered center rows
SBS-SA, SBS-TA
or APP-TA
SBS-SA, APP-
SA, SBS-TA or
APP-TA
-60.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 45 of 58
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet (Note A below) Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Cap Ply
LWC-35 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Celcore MF
B2 (with poly-film
top surface) Trufast FM-90 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three
equally spaced, staggered center rows Polyflex SA Base APP-TA -60.0
LWC-36 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Celcore B1 through B12 Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 3-inch lap and 7-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
BP-AA, SBS-AA,
SBS-TA, APP-TA
SBS-AA, APP-
TA -75.0
LWC-37 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Celcore MF Elastobase P Trufast FM-290 10-inch o.c. in a 4-inch lap and 10-inch o.c. in three
equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-
TA, APP-TA -90.0
ELASTIZELL CELLULAR LIGHTWEIGHT INSULATING CONCRETE:
LWC-38
Min. 0.0179-inch Tensilform S-75
or min. 0.0205-inch Tensilform
75 at max. 5 ft spans or
structural concrete
Min. 200 psi, min. 2-inch thick
Elastizell Range II B1 through B12 Trufast FM-90
or OMG CR BPF
7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
BP-AA, SBS-AA,
SBS-TA, or APP-
TA
SBS-AA, SBS-
TA, or APP-TA -30.0
LWC-39
Min. 0.0179-inch Tensilform S-75
or min. 0.0205-inch Tensilform
75 at max. 5 ft spans or
structural concrete
Min. 200 psi, min. 2-inch thick
Elastizell Range II
B2 (with poly-film
top surface)
Trufast FM-90
or OMG CR BPF
7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
SBS-SA, SBS-TA
or APP-TA
SBS-SA, APP-
SA, SBS-TA or
APP-TA
-30.0
LWC-40 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 200 psi, min. 2-inch thick
Elastizell Range II B1 through B12 Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 3-inch lap and 7-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
BP-AA, SBS-AA,
SBS-TA, or APP-
TA
SBS-AA, SBS-
TA, or APP-TA -45.0
LWC-41 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 200 psi, min. 2-inch thick
Elastizell Range II
B2 (with poly-film
top surface)
Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 3-inch lap and 7-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
SBS-SA, SBS-TA
or APP-TA
SBS-SA, APP-
SA, SBS-TA or
APP-TA
-45.0
LWC-42 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 200 psi, min. 2-inch thick
Elastizell Range II
B2 (with poly-film
top surface)
Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 3-inch lap and 7-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
Polyflex SA Base APP-TA -45.0
LWC-43
Min. 22 ga., type B vented steel
at max 5 ft spans or structural
concrete
Min. 350 psi, min. 2-inch thick
Elastizell with Zell-Crete Fibers,
supplemental attached with Roofgrip
#21 and 3-inch plates at 1 per 8 ft2
Elastobase P (with
poly-film top
surface)
Trufast FM-290
8-inch o.c. in a 4-inch lap and 8-inch o.c. in three,
equally spaced, staggered rows in the field of the
sheet
(Optional) BP-
AA, SBS-AA, SBS-
TA, or APP-TA
SBS-AA, SBS-
TA, or APP-TA -52.5
LWC-44 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 350 psi, min. 2-inch thick
Elastizell with Zell-Crete Fibers,
supplemental attached with Roofgrip
#21 and 3-inch plates at 1 per 8 ft2
B2
Trufast Twin
Loc-Nails (min.
1.8-inch)
6-inch o.c. in a 4-inch lap and 6-inch o.c. in three,
equally spaced, staggered rows in the field of the
sheet
BP-AA or SBS-AA
SBS-AA, SBS-
TA, SBS-SA,
APP-TA or
APP-SA
-60.0
LWC-45 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 350 psi, min. 2-inch thick
Elastizell with Zell-Crete Fibers,
supplemental attached with Roofgrip
#21 and 3-inch plates at 1 per 8 ft2
B2 (with poly-film
top surface)
Trufast Twin
Loc-Nails (min.
1.8-inch)
6-inch o.c. in a 4-inch lap and 6-inch o.c. in three,
equally spaced, staggered rows in the field of the
sheet
SBS-SA, SBS-TA
or APP-TA
SBS-SA, APP-
SA, SBS-TA or
APP-TA
-60.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 46 of 58
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet (Note A below) Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Base Ply Cap Ply
LWC-46 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 350 psi, min. 2-inch thick
Elastizell with Zell-Crete Fibers,
supplemental attached with Roofgrip
#21 and 3-inch plates at 1 per 8 ft2
B2 (with poly-film
top surface)
Trufast Twin
Loc-Nails (min.
1.8-inch)
6-inch o.c. in a 4-inch lap and 6-inch o.c. in three,
equally spaced, staggered rows in the field of the
sheet
Polyflex SA Base APP-TA -60.0
MEARLCRETE CELLULAR LIGHTWEIGHT INSULATING CONCRETE:
LWC-47 Min. 24 ga., type B steel at max 5
ft spans or structural concrete
Min. 200 psi, min. 2-inch thick
Mearlcrete B1 through B12 Trufast FM-90
or OMG CR BPF
7.5-inch o.c. in a 3-inch lap and 10-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
BP-AA, SBS-AA SBS-AA -30.0
LWC-48 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Mearlcrete B1, B2 or B12 Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 4-inch lap and 7-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
BP-AA, SBS-AA,
SBS-TA, or APP-
TA
SBS-AA, SBS-
TA, or APP-TA -45.0
LWC-49 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Mearlcrete
B2 (with poly-film
top surface)
Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 4-inch lap and 7-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
SBS-SA, SBS-TA
or APP-TA
SBS-SA, APP-
SA, SBS-TA or
APP-TA
-45.0
LWC-50 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Mearlcrete
B2 (with poly-film
top surface)
Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 4-inch lap and 7-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
Polyflex SA Base APP-TA -45.0
LWC-51 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Mearlcrete
B1, B2, B3, B7 or
B11
Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 4-inch lap and 7-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
BP-AA, SBS-AA,
SBS-TA, or APP-
TA
SBS-AA, SBS-
TA, or APP-TA -52.5
LWC-52 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Mearlcrete
B2 (with poly-film
top surface)
Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 4-inch lap and 7-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
SBS-SA, SBS-TA
or APP-TA
SBS-SA, APP-
SA, SBS-TA or
APP-TA
-52.5
LWC-53 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Mearlcrete
B2 (with poly-film
top surface)
Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 4-inch lap and 7-inch o.c. in two,
equally spaced, staggered rows in the field of the
sheet
Polyflex SA Base APP-TA -52.5
A. Base Sheets options in Table 4C are coded as follows:
B1: Polyglass G2 Base; B2: Elastobase or Elastobase P; B3: GAFGLAS #75; B4: GAFGLAS Stratavent Nailable Venting Base Sheet; B5: GAFGLAS Ply 4; B6: GAFGLAS FlexPly 6; B7: JM Perma Ply No. 28; B8: JM Vensulation; B9: JM
GlasPly IV; B10: JM GlasPly Premier; B11: Tamko Glass-Base; B12: Tamko Vapor-Chan
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 47 of 58
TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap Ply
CWF-1 Min. 2.5-inch Tectum
Plank or Tectum LS Plank
Min. 1.5-inch Polytherm, ACFoam
II, ISO 95+GL, Polytherm H, H-
Shield, Polytherm, ENRGY-3
D-IS or
OB500
Min. 0.25-inch Dens Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber Roof Board or min.
0.5-inch Structodek High Density Fiberboard
Roof Insulation
D-IS or OB500 BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
CWF-2 Min. 2.5-inch Tectum
Plank or Tectum LS Plank
Min. 1.5-inch Polytherm, ACFoam
II, ISO 95+GL, Polytherm H, H-
Shield, Polytherm, ENRGY-3
D-IS or
OB500
Min. 0.25-inch Dens Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber Roof Board D-IS or OB500 SBS-TA, SBS-SA or
APP-TA
(Optional) SBS-TA,
SBS-SA or APP-TA
SBS-TA, SBS-
SA, APP-TA,
APP-SA
-45.0
CWF-3 Min. 2.5-inch Tectum
Plank or Tectum LS Plank
Min. 1.5-inch Polytherm, ACFoam
II, ISO 95+GL, Polytherm H, H-
Shield, Polytherm, ENRGY-3
D-IS or
OB500
Min. 0.25-inch Dens Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber Roof Board D-IS or OB500 Polyflex SA Base (Optional) APP-TA APP-TA -45.0
CWF-4 Min. 2.5-inch Tectum
Plank or Tectum LS Plank
Min. 1.5-inch Polytherm, ACFoam
II, ISO 95+GL, Polytherm H, H-
Shield, Polytherm, ENRGY-3
CR-20
Min. 0.25-inch Dens Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber Roof Board or min.
0.5-inch Structodek High Density Fiberboard
Roof Insulation
CR-20 BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
CWF-5 Min. 2.5-inch Tectum
Plank or Tectum LS Plank
Min. 1.5-inch Polytherm, ACFoam
II, ISO 95+GL, Polytherm H, H-
Shield, Polytherm, ENRGY-3
CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-TA, SBS-SA or
APP-TA
(Optional) SBS-TA,
SBS-SA or APP-TA
SBS-TA, SBS-
SA, APP-TA,
APP-SA
-52.5
CWF-6 Min. 2.5-inch Tectum
Plank or Tectum LS Plank
Min. 1.5-inch Polytherm, ACFoam
II, ISO 95+GL, Polytherm H, H-
Shield, Polytherm, ENRGY-3
CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber Roof Board CR-20 Polyflex SA Base (Optional) APP-TA APP-TA -52.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 48 of 58
TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap Ply
CWF-7
Min. 2.5-inch
Tectum Plank
or Tectum LS
Plank
Elastobase,
Elastobase P,
Polyglass G2
Base
Trufast
Inuldek
Loc-Nail
9-inch o.c. in 4-inch
lap and 12-inch o.c.
in two, equally
spaced, staggered
center rows
Min. 1.5-inch Polytherm,
ACFoam II, Polytherm G,
ACFoam III, ISO95+GL,
Polytherm H, H-Shield,
ENRGY 3, Polytherm or
Multi-Max FA3,
Hot
asphalt
Min. 0.25-inch Dens Deck,
Dens Deck Prime, SECUROCK
Gypsum-Fiber Roof Board,
Min. 0.75-inch Fesco Board
(homogeneous) or min. 0.5-
inch Structodek High Density
Fiberboard Roof Insulation
Hot
asphalt
BP-AA,
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA,
APP-TA
-30.0*
CWF-8
Min. 2.5-inch
Tectum Plank
or Tectum LS
Plank
Elastobase,
Elastobase P,
Polyglass G2
Base
Trufast
Inuldek
Loc-Nail
9-inch o.c. in 4-inch
lap and 12-inch o.c.
in two, equally
spaced, staggered
center rows
Min. 1.5-inch Polytherm,
ACFoam II, Polytherm G,
ACFoam III, ISO95+GL,
Polytherm H, H-Shield,
ENRGY 3, Polytherm or
Multi-Max FA3,
Hot
asphalt
Min. 0.25-inch Dens Deck,
Dens Deck Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
SBS-TA,
SBS-SA or
APP-TA
(Optional) SBS-
TA, SBS-SA or
APP-TA
SBS-TA,
SBS-SA,
APP-TA,
APP-SA
-30.0*
CWF-9
Min. 2.5-inch
Tectum Plank
or Tectum LS
Plank
Elastobase,
Elastobase P,
Polyglass G2
Base
Trufast
Inuldek
Loc-Nail
9-inch o.c. in 4-inch
lap and 12-inch o.c.
in two, equally
spaced, staggered
center rows
Min. 1.5-inch Polytherm,
ACFoam II, Polytherm G,
ACFoam III, ISO95+GL,
Polytherm H, H-Shield,
ENRGY 3, Polytherm or
Multi-Max FA3,
Hot
asphalt
Min. 0.25-inch Dens Deck,
Dens Deck Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
Polyflex
SA Base
(Optional) APP-
TA APP-TA -30.0*
CWF-10
Min. 2.5-inch
Tectum Plank
or Tectum LS
Plank
Elastobase,
Elastobase P,
Polyglass G2
Base
Trufast
Twin Loc-
Nail
9-inch o.c. in 4-inch
lap and 18-inch o.c.
in two, equally
spaced, staggered
center rows
Min. 1.5-inch Polytherm,
ACFoam II, Polytherm G,
ACFoam III, ISO95+GL,
Polytherm H, H-Shield,
ENRGY 3, Polytherm or
Multi-Max FA3,
Hot
asphalt
Min. 0.25-inch Dens Deck,
Dens Deck Prime, SECUROCK
Gypsum-Fiber Roof Board,
Min. 0.75-inch Fesco Board
(homogeneous) or min. 0.5-
inch Structodek High Density
Fiberboard Roof Insulation
Hot
asphalt
BP-AA,
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
CWF-11
Min. 2.5-inch
Tectum Plank
or Tectum LS
Plank
Elastobase,
Elastobase P,
Polyglass G2
Base
Trufast
Twin Loc-
Nail
9-inch o.c. in 4-inch
lap and 18-inch o.c.
in two, equally
spaced, staggered
center rows
Min. 1.5-inch Polytherm,
ACFoam II, Polytherm G,
ACFoam III, ISO95+GL,
Polytherm H, H-Shield,
ENRGY 3, Polytherm or
Multi-Max FA3,
Hot
asphalt
Min. 0.25-inch Dens Deck,
Dens Deck Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
SBS-TA,
SBS-SA or
APP-TA
(Optional) SBS-
TA, SBS-SA or
APP-TA
SBS-TA,
SBS-SA,
APP-TA,
APP-SA
-45.0*
CWF-12
Min. 2.5-inch
Tectum Plank
or Tectum LS
Plank
Elastobase,
Elastobase P,
Polyglass G2
Base
Trufast
Twin Loc-
Nail
9-inch o.c. in 4-inch
lap and 18-inch o.c.
in two, equally
spaced, staggered
center rows
Min. 1.5-inch Polytherm,
ACFoam II, Polytherm G,
ACFoam III, ISO95+GL,
Polytherm H, H-Shield,
ENRGY 3, Polytherm or
Multi-Max FA3,
Hot
asphalt
Min. 0.25-inch Dens Deck,
Dens Deck Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
Polyflex
SA Base
(Optional) APP-
TA APP-TA -45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 49 of 58
TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten Attach Type Attach Base Ply Ply Cap Ply
CWF-13
Min. 2.5-inch Tectum
Plank or Tectum LS
Plank
Min. 2-inch H-
Shield or
Polytherm
OMG Polymer GypTec Plate with
Polymer GypTec or Trufast TL 3
in. Plate with TL Fastener
1 per 4 ft2
Min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation
Hot
asphalt
(Optional if
using AA Ply)
BP-AA, SBS-AA
(Optional if using AA
Base) BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
TABLE 5D: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten Attach Base Ply Ply Cap Ply
CWF-14
Min. 2.5-inch
Tectum Plank or
Tectum LS Plank
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck, Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board or min.
0.5-inch Structodek High Density Fiberboard
Roof Insulation
Trufast Twin Loc-Nails
(min. 1-inch
embedment)
1 per 2 ft2
(Optional if
using AA Ply)
BP-AA, SBS-AA
(Optional if using AA
Base) BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
TABLE 5E: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten Attach Base Ply Cap Ply
CWF-15
Min. 2.5-inch Tectum
Plank or Tectum LS
Plank
Elastobase, Elastobase P, Polyglass G2 Base Trufast Inuldek Loc-Nail 9-inch o.c. in 4-inch lap and 12-inch o.c. in two,
equally spaced, staggered center rows
(Optional) BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA,
SBS-TA,
APP-TA
-30.0*
CWF-16
Min. 2.5-inch Tectum
Plank or Tectum LS
Plank
Elastobase, Elastobase P, Polyglass G2 Base Trufast Twin Loc-Nails 9-inch o.c. in 4-inch lap and 18-inch o.c. in two,
equally spaced, staggered center rows
(Optional) BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 50 of 58
TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
SELF-ADHERING BASE:
G-1
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, Polytherm H or H-Shield or min.
2.0 pcf, Insulfoam
OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -72.5
G-2
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch min. 2.0 pcf, Insulfoam OB500 (Optional) additional layers(s) of base
insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -112.5
G-3
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, Polytherm H or H-Shield OB500 (Optional) additional layers(s) of base
insulation OB500 SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -112.5
G-4
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, Polytherm H or H-Shield OB500 (Optional) additional layers(s) of base
insulation OB500 Polyflex SA
Base (Optional) APP-TA APP-TA -112.5
G-5
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, Polytherm H or H-Shield or min.
2.0 pcf, Insulfoam
OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board OB500 SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -112.5
G-6
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, Polytherm H or H-Shield or min.
2.0 pcf, Insulfoam
OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board OB500 Polyflex SA
Base (Optional) APP-TA APP-TA -112.5
G-7
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA Min. 0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -72.5
G-8
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA
(Optional) additional layers(s) of base
insulation and/or min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
M-OSFA SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -202.5
G-9
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA
(Optional) additional layers(s) of base
insulation and/or min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
M-OSFA Polyflex SA
Base (Optional) APP-TA APP-TA -202.5
G-10
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch, min. 2.0 pcf EPS insulation
board, Polytherm, ACFoam II, Polytherm
G, ACFoam III, ENRGY 3, Polytherm H, H-
Shield, H-Shield CG or Multi-Max FA3
CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -72.5
G-11
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 (Optional) additional layers of base
insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA -240.0
G-12
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board CR-20 SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -240.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 51 of 58
TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
G-13
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board CR-20 Polyflex SA
Base (Optional) APP-TA APP-TA -240.0
G-14
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3,
Polytherm H, H-Shield, H-Shield CG or
Multi-Max FA3
CR-20
(Optional) additional layers(s) of base
insulation and/or min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
CR-20 Polyflex SA
Base (Optional) APP-TA APP-TA -257.5
G-15
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1.5-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3,
Polytherm H, H-Shield, H-Shield CG or
Multi-Max FA3
CR-20
(Optional) additional layers(s) of base
insulation and/or min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
CR-20 SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -257.5
ASPHALT-APPLIED BASE:
G-16
Existing, sound
poured gypsum or
gypsum plank deck
Min. 0.25-inch Dens Deck, Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof
Board
CR-20 None N/A
(Optional if
using AA Ply)
BP-AA, SBS-AA
(Optional if using AA Base)
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-TA,
APP-TA -245.0
COLD APPLIED BASE:
G-17
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, EnergyGuard
Polyiso Insulation, ENRGY 3, Polytherm H,
H-Shield ISO 95+ GL, Multi-Max FA3,
RESISTA or UltraMax or min. 2-inch
DECKMATE Plus or DECKMATE Plus FA
M-OSFA
Min. 0.25-inch Dens Deck, Dens Deck Prime,
DEXcell FA Glass Mat Roof Board, SECUROCK
Gypsum-Fiber Roof Board or SECUROCK
Glass-Mat Roof Board, min. 7/16-inch
DEXcell Cement Roof Board or min. 0.5-inch
SECUROCK Cement Roof Board
M-OSFA SBS-CA1, SBS-
CA2
(Optional) SBS-CA1, SBS-
CA2
SBS-CA1, SBS-
CA2, APP-CA1 -120.0
G-18
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1-inch Polytherm or ACFoam II,
Polytherm G, ACFoam III, EnergyGuard
Polyiso Insulation, ENRGY 3, Polytherm H,
H-Shield, ISO 95+ GL, Multi-Max FA3,
RESISTA or UltraMax or min. 2-inch
DECKMATE Plus or DECKMATE Plus FA
M-OSFA
Min. 0.25-inch Dens Deck Prime or DEXcell
FA Glass Mat Roof Board, min. 7/16-inch
DEXcell Cement Roof Board or min. 0.5-inch
SECUROCK Cement Roof Board
M-OSFA SBS-CA1 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
G-19
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1-inch Polytherm or ACFoam II,
Polytherm G, ACFoam III, EnergyGuard
Polyiso Insulation, ENRGY 3, Polytherm H,
H-Shield, ISO 95+ GL, Multi-Max FA3,
RESISTA or UltraMax or min. 2-inch
DECKMATE Plus or DECKMATE Plus FA
M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board M-OSFA SBS-CA1, SBS-
CA2 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
G-20
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1-inch Polytherm or ACFoam II,
Polytherm G, ACFoam III, EnergyGuard
Polyiso Insulation, ENRGY 3, Polytherm H,
H-Shield, ISO 95+ GL, Multi-Max FA3,
RESISTA or UltraMax or min. 2-inch
DECKMATE Plus or DECKMATE Plus FA
M-OSFA
Min. 0.25-inch Dens Deck, Dens Deck Prime,
DEXcell FA Glass Mat Roof Board, SECUROCK
Gypsum-Fiber Roof Board or SECUROCK
Glass-Mat Roof Board, min. 7/16-inch
DEXcell Cement Roof Board or min. 0.5-inch
SECUROCK Cement Roof Board
M-OSFA SBS-CA1, SBS-
CA2 None SBS-CA1, SBS-
CA2 -202.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 52 of 58
TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
G-21
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3,
Polytherm H, H-Shield or Multi-Max FA3
OB500
Min. 0.25-inch Dens Deck Prime, DEXcell FA
Glass Mat Roof Board or SECUROCK
Gypsum-Fiber Roof Board
OB500 SBS-CA1, SBS-
CA2
(Optional) SBS-CA1, SBS-
CA2
SBS-CA1, SBS-
CA2, APP-CA1 -112.5
G-22
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3,
Polytherm H, H-Shield or Multi-Max FA3
CR-20 Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-CA1, SBS-
CA2
(Optional) SBS-CA1, SBS-
CA2
SBS-CA1, SBS-
CA2, APP-CA1 -120.0
G-23
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3,
Polytherm H, H-Shield or Multi-Max FA3
CR-20 Min. 0.25-inch Dens Deck Prime or DEXcell
FA Glass Mat Roof Board CR-20 SBS-CA1 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
G-24
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1-inch Polytherm, ACFoam II,
Polytherm G, ACFoam III, ENRGY 3,
Polytherm H, H-Shield or Multi-Max FA3
CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board CR-20 SBS-CA1, SBS-
CA2 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
G-25
Existing, sound
poured gypsum or
gypsum plank deck
Min. 1-inch ENRGY 3, Polytherm H, H-
Shield, Multi-Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-CA1, SBS-
CA2 None SBS-CA1, SBS-
CA2 -232.5
TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap Ply
G-26
Existing, sound
poured gypsum
or gypsum
plank deck
Elastobase,
Elastobase
P, Polyglass
G2 Base
Trufast FM-75
or FM-90 or
Twin Loc-Nails
9-inch o.c. in 4-
inch lap and 18-
inch o.c. in two,
equally spaced,
staggered center
rows
Min. 1.5-inch Polytherm,
ACFoam II, Polytherm G,
ACFoam III, ISO95+GL,
Polytherm H, H-Shield,
ENRGY 3, Polytherm or
Multi-Max FA3
Hot
asphalt
Min. 0.25-inch Dens Deck, Dens Deck
Prime, SECUROCK Gypsum-Fiber Roof
Board, Min. 0.75-inch Fesco Board
(homogeneous) or min. 0.5-inch
Structodek High Density Fiberboard
Roof Insulation
Hot
asphalt
BP-AA,
SBS-AA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 53 of 58
TABLE 6C: GYPSUM DECKS – REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten Attach Base Ply Ply Cap Ply
G-27
Existing sound
poured gypsum or
gypsum plank deck
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck, Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch
Structodek High Density Fiberboard Roof Insulation
Trufast Twin Loc-
Nails (min. 1-inch
embedment)
1 per 2
ft2
(Optional if
using AA Ply)
BP-AA, SBS-AA
(Optional if using AA Base)
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
TABLE 6D: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten Attach Base Ply Cap Ply
G-28 Existing sound poured gypsum
or gypsum plank deck
Elastobase, Elastobase P,
Polyglass G2 Base
Trufast FM-75 or FM-90
or Twin Loc-Nails
9-inch o.c. in 4-inch lap and 18-inch o.c. in
two, equally spaced, staggered center rows
(Optional) BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-TA,
APP-TA -45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 54 of 58
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
SELF-ADHERING BASE:
R-1 Existing asphaltic roof Min. 1.5-inch Multi-Max FA3 D-IS
(Optional) additional layers(s) of base insulation
and/or min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board or Dens Deck Prime
D-IS SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -67.5
R-2 Existing asphaltic roof Min. 1.5-inch Multi-Max FA3 D-IS
(Optional) additional layers(s) of base insulation
and/or min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board or Dens Deck Prime
D-IS Polyflex SA
Base (Optional) APP-TA APP-TA -67.5
R-3 Existing asphaltic roof
Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3 or Multi-Max FA3 or min. 2.0 pcf
Insulfoam
D-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -72.5
R-4 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam D-IS (Optional) additional layers(s) of base insulation D-IS SBS-SA (Optional) SBS-SA SBS-SA -90.0
R-5 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board D-IS SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -90.0
R-6 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board D-IS Polyflex SA
Base (Optional) APP-TA APP-TA -90.0
R-7 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II or
ENRGY 3 D-IS
(Optional) additional layers(s) of base insulation
and/or min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
D-IS SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -90.0
R-8 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II or
ENRGY 3 D-IS
(Optional) additional layers(s) of base insulation
and/or min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
D-IS Polyflex SA
Base (Optional) APP-TA APP-TA -90.0
R-9
Existing smooth- or
granule-surfaced asphalt
built-up roof or SBS
modified bitumen or
existing granule-surfaced
APP modified bitumen
(Optional) Min. 1-inch Polytherm,
ACFoam II, Polytherm G, ACFoam III,
Polytherm H or H-Shield
D-IS
Min. 0.25-inch Dens Deck Prime, DEXcell FA
Glass Mat Roof Board or SECUROCK Gypsum-
Fiber Roof Board
PRIMER: PG100
D-IS
Polyflex SA
Base primed
with PG100
None SBS-SA, APP-SA -93.8
R-10 Existing asphaltic roof
Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, Polytherm H or H-Shield or min.
2.0 pcf Insulfoam
OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -72.5
R-11
Existing smooth- or
granule-surfaced asphalt
built-up roof or SBS
modified bitumen or
existing granule-surfaced
APP modified bitumen
(Optional) Min. 1-inch Polytherm,
ACFoam II, Polytherm G, ACFoam III,
Polytherm H or H-Shield
OB500
Min. 0.25-inch Dens Deck Prime, DEXcell FA
Glass Mat Roof Board or SECUROCK Gypsum-
Fiber Roof Board
PRIMER: PG100
OB500
Polyflex SA
Base primed
with PG100
None SBS-SA, APP-SA -93.8
R-12 Existing asphaltic roof Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 (Optional) additional layers of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0
R-13 Existing asphaltic roof Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board OB500 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -120.0
R-14 Existing asphaltic roof Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board OB500 Polyflex SA
Base (Optional) APP-TA APP-TA -120.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 55 of 58
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
R-15 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, Polytherm H or H-Shield OB500
(Optional) additional layers(s) of base insulation
and/or min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -127.5
R-16 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, Polytherm H or H-Shield OB500
(Optional) additional layers(s) of base insulation
and/or min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500 Polyflex SA
Base (Optional) APP-TA APP-TA -127.5
R-17 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA Min. 0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -72.5
R-18
Existing smooth- or
granule-surfaced asphalt
built-up roof or SBS
modified bitumen or
existing granule-surfaced
APP modified bitumen
(Optional) Min. 1-inch Polytherm,
ACFoam II, Polytherm G, ACFoam III,
Polytherm H or H-Shield
M-OSFA
or M-PG1
Min. 0.25-inch Dens Deck Prime, DEXcell FA
Glass Mat Roof Board or SECUROCK Gypsum-
Fiber Roof Board
PRIMER: PG100
M-OSFA
or M-PG1
Polyflex SA
Base primed
with PG100
None SBS-SA, APP-SA -93.8
R-19 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA
(Optional) additional layers(s) of base insulation
and/or min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
M-OSFA SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -157.5
R-20 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA
(Optional) additional layers(s) of base insulation
and/or min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
M-OSFA Polyflex SA
Base (Optional) APP-TA APP-TA -157.5
R-21 Existing asphaltic roof
Min. 1.5-inch min. 2.0 pcf Insulfoam,
Min. 2-inch Polytherm, ACFoam II, min.
1.5-inch Ultra-Max or Multi-Max FA-3,
min. 1.3-inch Polytherm G, ACFoam III or
min. 1.0-inch ISO 95+GL, Polytherm H, H-
Shield, H-Shield CG or ENRGY 3
CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -72.5
R-22
Existing smooth- or
granule-surfaced asphalt
built-up roof or SBS
modified bitumen or
existing granule-surfaced
APP modified bitumen
(Optional) Min. 1-inch Polytherm,
ACFoam II, Polytherm G, ACFoam III,
Polytherm H or H-Shield
CR-20
Min. 0.25-inch Dens Deck Prime, DEXcell FA
Glass Mat Roof Board or SECUROCK Gypsum-
Fiber Roof Board
PRIMER: PG100
CR-20
Polyflex SA
Base primed
with PG100
None SBS-SA, APP-SA -93.8
R-23 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam CR-20 (Optional) additional layers(s) of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA -240.0
R-24 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board CR-20 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -240.0
R-25 Existing asphaltic roof
Min. 1.5-inch Ultra-Max or Multi-Max FA-
3, min. 1.3-inch Polytherm G, ACFoam III
or min. 1.0-inch ISO 95+GL, Polytherm H,
H-Shield, H-Shield CG or ENRGY 3
CR-20
(Optional) additional layers(s) of base insulation
and/or min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
CR-20 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -240.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 56 of 58
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
R-26 Existing asphaltic roof
Min. 1.5-inch Ultra-Max or Multi-Max FA-
3, min. 1.3-inch Polytherm G, ACFoam III
or min. 1.0-inch ISO 95+GL, Polytherm H,
H-Shield, H-Shield CG or ENRGY 3
CR-20
(Optional) additional layers(s) of base insulation
and/or min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
CR-20 Polyflex SA
Base (Optional) APP-TA APP-TA -240.0
R-27 Existing asphaltic roof Min. 2-inch Polytherm, ACFoam II,
ENRGY-3, Polytherm H or H-Shield CR-20
(Optional) additional layers(s) of base insulation
and/or min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
CR-20 SBS-SA (Optional) SBS-SA, SBS-
TA, APP-TA
SBS-SA, APP-SA,
SBS-TA, APP-TA -247.5
R-28 Existing asphaltic roof Min. 2-inch Polytherm, ACFoam II,
ENRGY-3, Polytherm H or H-Shield CR-20
(Optional) additional layers(s) of base insulation
and/or min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
CR-20 Polyflex SA
Base (Optional) APP-TA APP-TA -247.5
ASPHALT OR TORCH APPLIED BASE:
R-29 Existing asphaltic roof Min. 1.5-inch Multi-Max FA3 D-IS Min. 0.25-inch Dens Deck, Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board D-IS
BP-AA, SBS-
AA, SBS-TA,
APP-TA
(Optional) BP-AA, SBS-
AA, SBS-TA or APP-TA
SBS-AA, SBS-TA
or APP-TA -67.5
R-30 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II or
ENRGY 3 or min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch Dens Deck, Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board D-IS
BP-AA, SBS-
AA, SBS-TA,
APP-TA
(Optional) BP-AA, SBS-
AA, SBS-TA or APP-TA
SBS-AA, SBS-TA,
or APP-TA -90.0
R-31 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, H-Shield or ISO 95+GL OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board OB500
BP-AA, SBS-
AA, SBS-TA,
APP-TA
(Optional) BP-AA, SBS-
AA, SBS-TA or APP-TA
SBS-AA, SBS-TA,
or APP-TA -127.5
R-32 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II,
ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board M-OSFA
BP-AA, SBS-
AA, SBS-TA,
APP-TA
(Optional) BP-AA, SBS-
AA, SBS-TA or APP-TA
SBS-AA, SBS-TA,
or APP-TA -157.5
R-33 Existing asphaltic roof
Min. 1.5-inch Ultra-Max or Multi-Max FA-
3, min. 1.3-inch Polytherm G, ACFoam III
or min. 1.0-inch ISO 95+GL, Polytherm H,
H-Shield, H-Shield CG or ENRGY 3 or min.
2.0 pcf Insulfoam
CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board CR-20 BP-AA, SBS-
AA
(Optional) BP-AA, SBS-
AA SBS-AA -225.0
R-34 Existing asphaltic roof
Min. 1.5-inch Ultra-Max or Multi-Max FA-
3, min. 1.3-inch Polytherm G, ACFoam III
or min. 1.0-inch ISO 95+GL, Polytherm H,
H-Shield, H-Shield CG or ENRGY 3 or min.
2.0 pcf Insulfoam
CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board CR-20 APP-TA (Optional) APP-TA APP-TA -232.5
COLD APPLIED BASE:
R-35 Existing asphaltic roof
(Optional) Min. 1-inch Polytherm,
ACFoam II, Polytherm G, ACFoam III,
ENRGY 3, Polytherm H or H-Shield
D-IS
Min. 0.25-inch Dens Deck Prime, DEXcell FA
Glass Mat Roof Board or SECUROCK Gypsum-
Fiber Roof Board
D-IS SBS-CA1,
SBS-CA2
(Optional) SBS-CA1,
SBS-CA2
SBS-CA1, SBS-
CA2, APP-CA1 -90.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 57 of 58
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
R-36 Existing asphaltic roof
(Optional) Min. 1-inch Polytherm,
ACFoam II, Polytherm G, ACFoam III,
EnergyGuard Polyiso Insulation, ENRGY 3,
Polytherm H, H-Shield ISO 95+ GL, Multi-
Max FA3, RESISTA or UltraMax or min. 2-
inch DECKMATE Plus or DECKMATE Plus
FA
M-OSFA,
M-PG1
Min. 0.25-inch Dens Deck, Dens Deck Prime,
DEXcell FA Glass Mat Roof Board, SECUROCK
Gypsum-Fiber Roof Board or SECUROCK Glass-
Mat Roof Board, min. 7/16-inch DEXcell Cement
Roof Board or min. 0.5-inch SECUROCK Cement
Roof Board
M-OSFA
or M-PG1
SBS-CA1,
SBS-CA2
(Optional) SBS-CA1,
SBS-CA2
SBS-CA1, SBS-
CA2, APP-CA1 -120.0
R-37 Existing asphaltic roof
(Optional) Min. 1-inch Polytherm or
ACFoam II, Polytherm G, ACFoam III,
EnergyGuard Polyiso Insulation, ENRGY 3,
Polytherm H, H-Shield, ISO 95+ GL, Multi-
Max FA3, RESISTA or UltraMax or min. 2-
inch DECKMATE Plus or DECKMATE Plus
FA
M-OSFA,
M-PG1
Min. 0.25-inch Dens Deck Prime or DEXcell FA
Glass Mat Roof Board, min. 7/16-inch DEXcell
Cement Roof Board or min. 0.5-inch SECUROCK
Cement Roof Board
M-OSFA,
M-PG1 SBS-CA1 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
R-38 Existing asphaltic roof
(Optional) Min. 1-inch Polytherm or
ACFoam II, Polytherm G, ACFoam III,
EnergyGuard Polyiso Insulation, ENRGY 3,
Polytherm H, H-Shield, ISO 95+ GL, Multi-
Max FA3, RESISTA or UltraMax or min. 2-
inch DECKMATE Plus or DECKMATE Plus
FA
M-OSFA,
M-PG1
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
M-OSFA,
M-PG1
SBS-CA1,
SBS-CA2 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
R-39 Existing asphaltic roof
(Optional) Min. 1-inch Polytherm or
ACFoam II, Polytherm G, ACFoam III,
EnergyGuard Polyiso Insulation, ENRGY 3,
Polytherm H, H-Shield, ISO 95+ GL, Multi-
Max FA3, RESISTA or UltraMax or min. 2-
inch DECKMATE Plus or DECKMATE Plus
FA
M-OSFA,
M-PG1
Min. 0.25-inch Dens Deck, Dens Deck Prime,
DEXcell FA Glass Mat Roof Board, SECUROCK
Gypsum-Fiber Roof Board or SECUROCK Glass-
Mat Roof Board, min. 7/16-inch DEXcell Cement
Roof Board or min. 0.5-inch SECUROCK Cement
Roof Board
M-OSFA,
M-PG1
SBS-CA1,
SBS-CA2 None SBS-CA1, SBS-
CA2 -157.5
R-40 Existing asphaltic roof
(Optional) Min. 1-inch Polytherm,
ACFoam II, Polytherm G, ACFoam III,
ENRGY 3, Polytherm H, H-Shield or Multi-
Max FA3
OB500
Min. 0.25-inch Dens Deck Prime, DEXcell FA
Glass Mat Roof Board or SECUROCK Gypsum-
Fiber Roof Board
OB500 SBS-CA1,
SBS-CA2
(Optional) SBS-CA1,
SBS-CA2
SBS-CA1, SBS-
CA2, APP-CA1 -120.0
R-41 Existing asphaltic roof
(Optional) Min. 1-inch Polytherm,
ACFoam II, Polytherm G, ACFoam III,
ENRGY 3, Polytherm H, H-Shield or Multi-
Max FA3
OB500 Min. 0.25-inch Dens Deck Prime or DEXcell FA
Glass Mat Roof Board OB500 SBS-CA1 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
R-42 Existing asphaltic roof
(Optional) Min. 1-inch Polytherm,
ACFoam II, Polytherm G, ACFoam III,
ENRGY 3, Polytherm H, H-Shield or Multi-
Max FA3
OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board OB500 SBS-CA1,
SBS-CA2 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 58 of 58
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
R-43 Existing asphaltic roof
(Optional) Min. 1-inch Polytherm,
ACFoam II, Polytherm G, ACFoam III,
ENRGY 3, Polytherm H, H-Shield or Multi-
Max FA3
CR-20 Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-CA1,
SBS-CA2
(Optional) SBS-CA1,
SBS-CA2
SBS-CA1, SBS-
CA2, APP-CA1 -120.0
R-44 Existing asphaltic roof
(Optional) Min. 1-inch Polytherm,
ACFoam II, Polytherm G, ACFoam III,
ENRGY 3, Polytherm H, H-Shield or Multi-
Max FA3
CR-20 Min. 0.25-inch Dens Deck Prime or DEXcell FA
Glass Mat Roof Board CR-20 SBS-CA1 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
R-45 Existing asphaltic roof
(Optional) Min. 1-inch Polytherm,
ACFoam II, Polytherm G, ACFoam III,
ENRGY 3, Polytherm H, H-Shield or Multi-
Max FA3
CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board CR-20 SBS-CA1,
SBS-CA2 None SBS-CA1, SBS-
CA2, APP-CA1 -127.5
R-46 Existing asphaltic roof (Optional) Min. 1-inch ENRGY 3,
Polytherm H, H-Shield, Multi-Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-CA1,
SBS-CA2 None SBS-CA1, SBS-
CA2 -232.5
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE F: NON-INSULATED, BONDED BASE SHEET, BONDED ROOF COVER
System No. Substrate
(Notes 1 & 12) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply
R-47 Existing asphaltic
roof PG100 BP-AA (Optional if using asphalt applied Ply) (Optional if using asphalt applied Base) BP-AA, SBS-
AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0