Loading...
HomeMy WebLinkAboutProduct Approval v r-- 12 W'WI Professional • / LCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications i contact Us i LCIS SRe Map Unks I Search i bL US r Product Approval IUSER:Public User Product Approval Menu>Product or Aopllcatlon Search>Application Ust>Application Detail FL# FL5444-R13 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer CertainTeed Corporation-Roofing Address/Phone/Email 20 Moores Road Malvern, PA 19355 (610)893-5400 mark.d.harner@saint-gobain.com Authorized Signature Mark Harner mark,d.harner@saint-gobain.com Technical Representative Mark D. Harrier Address/Phone/Email 18 Moores Road Malvern, PA 19355 (610)651-5847 Mark.D.Harner@saint-gobain.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 03/09/2020 Validated By John W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL5444_R1 _M_2018_Q1_M_NIEMINEN pa Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code I Product Approval Method Method 1 Option D Date Submitted 01/24/2018 Date Validated 01/29/2018 Date Pending FBC Approval 01/30/2018 Date Approved 04/10/2018 Date Revised 05/30/2018 Summary of Products FL* Model,Number or Name Description 5444.1 CertainTeed Asphalt Roof Shingles 3-tab,4-tab,strip(no-cut-outs), laminated and architectural asphalt roof shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL5444 R1 _LL2018 U_FjNQL_EELCERTAINTEED ASPHALT Approved for use outside HVHZ: Yes SHINGLES FL5444 R13.odf Impact Resistant: N/A Verified By: Robert Nieminen, PE PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use Evaluation Reports FL5444 R13 AE 2018 01 FINAL_E_R_CERTAINTEED ASPHALT SHINGLES FL5444-R13.pdf Created by Independent Third Party:Yes Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone;850-487-1824 The State of Florida is an AA/EEO employer.=ybht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here_. Product Approval Accepts: M® Will El M Credit Card Safe NEMO I etc. Certificate of Authorization#31455 353 Christian Street, Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT CertainTeed Corporation Evaluation Report 3532.09.05-1114 20 Moores Road FL5444-R13 Malvern,PA 19355 Date of Issuance:09/22/2005 (610)651-5847 Revision 14:01/24/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: CertainTeed Asphalt Roof Shingles. LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOJetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 13. Prepared by: Robert J.M.Nieminen,P.E. i s-,'° OF, i Florida Registration No.59166,Florida DCA ANE1983 �f �_^e'.eT✓�;�' The facsimile seal appearing was authorized by Robert 9 ' cs��;; ;.� Nieminen,P.E.on 01/24/2018. This does not serve as an •,n„..11”o electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOJetc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEW Ietc. nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. NEMO I etc. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: CertainTeed Asphalt Roof Shingles, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the 6`h Edition (2017) Florida Building Code and 6th Edition (2017) Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date UL(TST 1740) ASTM D3161 94NK9632 05/15/1998 UL(TST 1740) ASTM D3161 99NK26506 11/23/1999 UL(TST 1740) ASTM D3161 03CA12702 05/27/2003 UL(TST 1740) ASTM D3161 03CA12702 06/16/2003 UL(TST 1740) ASTM D3161 03NK29847 10/03/2003 UL(TST 1740) ASTM D3161 04CA11329 05/24/2004 UL(TST 1740) ASTM D3161 04CA32986 12/03/2004 UL(TST 1740) ASTM D3161 05NK07049 04/15/2005 UL(TST 1740) ASTM D3161 05NK16778 05/12/2005 UL(TST 1740) ASTM D3161 05CA16778 05/12/2005 UL(TST 1740) ASTM D3161 05NK14836 05/22/2005 UL(TST 1740) ASTM D3161 05NK22800 06/22/2005 UL(TST 1740) ASTM D3462 R684 09/21/2005 UL(TST 1740) ASTM D7158 05NK08037 06/28/2006 UL(TST 1740) ASTM D3161&D3462 09CA28873 07/23/2009 UL(TST 1740) ASTM D3462 10CA41303 10/07/2010 UL(TST 1740) ASTM D3161 10CA41303 10/08/2010 UL(TST 1740) ASTM D7158 10CA41303 10/27/2010 UL(TST 1740) ASTM D3161&D3462 10CA44960 11/11/2010 ULLLC(TST 9628) ASTM D3161,D3462&D7158 13CA32897 11/21/2013 UL LLC(TST 9628) ASTM D3161,D3462 TFWZ.R684 04/22/2014 UL LLC(TST 9628) ASTM D7158 TGAH.11684 04/22/2014 ULLLC(TST 9628) ASTM D3161&D3462 4786334434 09/16/2014 ULLLC(TST 9628) ASTM D3161&D3462 4786570826 02/12/2015 ULLLC(TST 9628) ASTM D3161,D3462&D7158 4786570717 12/16/2015 ULLLC(TST 9628) ASTM D3161&D3462 4787195678 02/09/2016 ULLLC(TST 9628) ASTM D3161,D3462&D7158 4787380356 10/26/2016 ULLLC(TST 9628) ASTM D3462 4787380357 10/13/2016 ULLLC(TST 9628) ASTM D7158 4787380357 11/08/2016 ULLLC(TST 9628) ASTM D3161 4787380357 11/09/2016 UL LLC(TST 9628) ASTM D3161,D3462&D7158 4787586427 01/25/2017 ULLLC(TST 9628) ASTM D3161&D3462 4788042412 11/15/2017 UL LLC(QUA 9625) Quality Control Service Confirmation Exp.03/09/2020 NEMO ETC,LLC Evaluation Report 3532.09.05-1114 Certificate of Authorization#31455 6'"EDITION(2017)FOC NON-HVHZ EVALUATION FL5444-1113 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 2 of 13 NEMO I etc. 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 CT20'",XT`25,XT'"30 and XT'"30 IR are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Arcadia'", Belmont®, Belmont® IR, Carriage House Shangle®, Grand Manor Shangle®, Landmark", Landmark" IR, Landmark'" Pro, Landmark'" Premium, Landmark'" TL, Landmark'" Solaris and Landmark'"Solaris IR are fiberglass reinforced,laminated asphalt roof shingles. 4.1.3 NorthGate'"is a fiberglass reinforced,laminated,SBS modified bitumen roof shingle. 4.1.4 Presidential ShakeTM, Presidential Shake'" 1R, Presidential Shake TL'" and Presidential Solaris'" are fiberglass reinforced,architectural asphalt roof shingles. 4.1.5 Hatteras'",Highland SlateT'and Highland Slate'"IR are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.6 Patriot'" is a fiberglass reinforced asphalt roof strip-shingle (with no cut-outs) providing a laminated appearance through an intermittent shadow line with contrasting blend drops for color definition. 4.2 Hip&Ridge Shingles: 4.2.1 Presidential Accessory, Accessory for Hatteras, Shangle Ridge'", Shadow Ridge'", Cedar CreStTM, Cedar Crest'" IR, NorthGate Ridge and NorthGate Accessory are fiberglass reinforced accessory shingles for hip and ridge installation. 4.3 Accessory Starter Strips: 4.3.1 SwiftStart® Starter Shingle is a starter strip for asphalt roof shingles. Its overall size of 15-1/4"x 38-3/4" yields two(2)7-5/8"x 38-3/4"starter pieces per shingle. 4.4 Any of the above listed shingles may be produced in AR(algae resistant)versions. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMOJetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use within FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 All shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for us in all wind zones UP to Vasd = 150 mph (Vit = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 Presidential Accessory, Accessory for Hatteras, Shangle Ridge, Shadow Ridge, Cedar Crest, NorthGate Ridge and NorthGate Accessory hip & ridge shingles have been evaluated in accordance with ASTM D3161,Class F. All except NorthGate Ridge and NorthGate Accessory require use of BASF Sonolastic NP 1 adhesive or Henkel PL® Polyurethane Roof & Flashing Sealant, applied as specified in manufacturer's application instructions, for use in wind zones up to Vasd= 150 mph(Vu,t=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 SwiftStart®Starter Shingle has been evaluated in accordance with ASTM D3161,Class F. Refer to Section 6 for installation requirements to meet this wind rating. 5.4.4 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. NEMO ETC,LLC Evaluation Report 3532.09.05-1134 Certificate of Authorization#31455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION F1.5444-1113 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 3 of 13 ONEMOletc. 5.4.4.1 Analysis in accordance with ASTM D7158 indicates the measured uplift resistance(RT)for the CertainTeed asphalt Roof shingles listed in Section 4.1 through 4.6(except Presidential Solaris'')exceeds the calculated uplift force (FT) at a maximum design wind speed of V.,d = 150 mph (V„It = 194 mph) for residential buildings located in Exposure D conditions with no topographical variations(flat terrain) having a mean roof height less than or equal to 60 feet. The shingles are permissible under Code for installation in these conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum requirements, subject to minimum codified fastening requirements established within any local jurisdiction,which shall take precedence. 5.5 All products in the roof assembly shall have quality assurance audits in accordance with FAC Rule 611320-3. 6. INSTALLATION: 6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.1 Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 611320-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Installation of asphalt shingles shall comply with the CertainTeed Corporation current published instructions, using minimum four(4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6 and the minimum requirements herein. 6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal,use the"Steep Slope"directions. 6.3 CertainTeed asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions. 6.4 SWIFTSTART""STARTER SHINGLE: Fastening: Use four nails, located as shown below 38-3/4'(984 mm) 1 r 1"(25 mm)from edge 1"(25 mm)from edge I 7-5/8" • • • Max 3" (194 mm) (76 mm) 1, tThe inner two fasteners must be placed such that they fall at least 3"(76 mm)from the end joints of the shingle in the succeeding course. NEW ETC,LLC Evaluation Report 3532.09.05-1114 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FLS444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 4 of 13 ONEMOletc. 6.5 t LOW AND STANDARD SLOPE STEEP SLOPE ENGLISH (305" (305" (305" Use four nails and six spots of asphalt roofing cement*for every full F ` shingle(Figure 11-4).Asphalt roofing cement meeting ASTM D4586 "(25mm) —Se lant 1"(25 mm) Type 11 is suggested. 5 5/a"(145 mtl _5112"P�ra --- ———— ——— -* MTMC 131/8" 131/6" f 131/8" pootiny CMnnnt Ul"(�225mm) Sealant 1"(25 mm) Apply 1"(25 nm)spots of asphalt roofing cement — under each lab corner. 61Figure 11-4:Use or nails ands&spots ofaspbalt om mt on steep slq e •CAUTION:Excessive use of roofing cement can cause shingles to blister. figure 11-3:Useforr nailsfor eaery fell sbingie. 6.5.1 Hip&Ridge for CT2011,XT'"25,XT'"30,XT"30 IR: Cut Shingles 1 .1�- -.{ I—2"(50 n1m) HPmove J� (25mm )f 1, ter ~`-T 5„ 12°(305 mm) Fast I} V&\ — — 1y — — —1� 12" (125 nen) — `� �das Cap — Cap _ — Cap �) Shingle Shingle Shingle ��$1 Figure I1-24:Cut tabs,then h*n back to make c4p sbin#m \1145 Dov Np1� (Fnglisb dimensions sboum). Figure 11-25.'Installation of cwps along the hips and ridges. 6.5.1.1 For ASTM D3161, Class F performance use BASF "Sonolastic® NPI" adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. 6.6 ARCADIA": LOW AND STANDARD SLOPE STEEP SLOPE Use SIX nail,for every hill shingle located as shown below. Use SIX nails and FOUR spots of asphalt roofing cement for even,hill shingle as shown below.Apply asphalt roofing cement 1"(25 nun) from edge of shingle.Asphalt roofing cement meeting A517M D 4586 Type fl is suggested. f-1'(25 mm) I'(25 mm)—� Nail Line Nail Nail Line — �-1'(25mm) 1'(25 mm)� r LL Figure 2:Use sk rails for eiv-0,fir/l sbingle. `' `'L `r 1j, Figura 3:Isesix nails and four spots of asphalt roofing cement on stckp slopes. NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate ofAuthorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1113 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 5 of 13 ONEMOletc. 6.6.1 Hip&Ridge for Arcadia'": Cedar Crest'",Cedar Crest—IR Use two (2), minimum 1%-inch long fasteners per shingle. For the starter shingle, place fastener 1-inch from each side edge and about 2-inch up from the starter shingle's exposed butt edge,ensuring minimum %-inch embedment into the deck,or full penetration through the deck. For each full Cedar Crest shingle, place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each side edge. For ASTM D3161,Class F performance use BASF"Sonolastic®NPI""adhesive or Henkel"PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements,to hand-seal Cedar Crest shingles. Apply NP 1 or PL adhesive from the middle of the shingle's raised overlay on the top piece and extending approximately 4-inch along the sides of the headlap along a line%to 1-inch from each side of the shingle's headlap. Immediately align and apply the overlying shingle,gently pressing tab sides into the adhesive,and install nails. To secure the other side,apply a 1-inch diameter spot of NP 1 or PL adhesive between the shingle layers. Hand-sealing adhesive 4" p03 mm) I✓(305 mm) - --------- 1/4" +- I���Sure-T f is'019b 3/4" --► Ir ✓`2 9 mm\ V Dab of asphalt cement between shingle layers " 6.7 • OR Low and Standard Slope Steep Slope(greater than 21:12): (2:12 to 21:12): Use SEVEN nails and EIGHT spots of Use FIVE nails for every full Belmont shingle, asphalt roofing cement*"for every full located as shown below. Belmont shingle.Apply asphalt roofing cement 1"(25mm)from edge of shingle. 11/2'138mm1 or las See below.Asphalt roofing cement meeting +� 1•(25Man) 1'(25mm)--i -- ASTM D4586 Type II is suggested. 518'(16 mm) 8 8. 1220I mm) 11/2'(38 mm) 1 of less o Additional nails if required 1—1-(25 mm) 1'(25 rrrn)—I I 5!8'06 mm) 8518' (220 mm) 1'(25 Roofing Cement------- NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate of Authorization#32455 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 6 of 13 NEMO I etc. 6.7.1 Hip&Ridge for Belmont®or Belmont®IR: 6.7.1.1 Option 1: For Belmont®,refer to instructions herein for Cedar Crest'"or Cedar Crest`"IR hip and ridge shingles. For Belmont®IR,refer to instructions herein for Cedar Crest'"IR hip and ridge shingles. 6.7.1.2 Option 2: For Belmont®: Shangle®Ridge 18, Remove tape 12• Exposure from the right side 81 and fasten r SECOND Fasten the Remove left Side 85�8�./ RIGHT This Tape FIRST l LEFT UIT Figure 17-19.'Installation of Sbangle@ Ridge sbingles Figure 17-18.'Sbangk*Ridge. on bips and ridges. 6.7.1.3 For ASTM D3161,Class F performance use BASF"Sonolastic®NPI1"adhesive or Henkel"PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. 6.8 CARRIAGE HOUSE SHANGLEO AND GRAND MANOR SHANGLE'�': LOW AND STEEP SLOPE STANDARD SLOPE Ilse seven nails and three spots of asphalt roofing cement for every full Grand Manor Shangle.Ilse five nails and three spots of asphalt l!se five nails for every full Shangle. roofing cement for every full Carriage(louse Shangle and Centennial Slue.Apply asphalt roofing cement 1"(25 mm)from edge of shingle (Figure 17-5).Asphalt roofing cement meeting ASM 04586 Type 11 1" T' is suggested. 1--(25 mm) (25 mm) ' 11/2' 5/8" 85/B" (38 mm) 116 mm) 101, (220 mm) or (25 mm). (25 mm) Figure 17-4:Use fpie nailsfir erery full Grand Manor Shangle, 5/81, 8 556' Carriage/louse.Sbangle,orCentennial Slate. (16mm)+i �� (220 mm) (25 mm) Roof*ComoM Figure 17-5:Wben installing Grand htanor.ibangles on steep slopes, use seeea nails and tbree spots of aspbaN roofing cement. 6.8.1 Hip&Ridge for Carriage House Shangle®and Grand Manor Shangle:Refer to instructions herein for Shangle®Ridge hip and ridge shingles NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate of Authorization#32455 6`"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 7 of 13 ONEMOjetc. 6.9 LANDMARK'" LANDMARK'" IR, LANDMARK'" PRO, LANDMARK'" PREMIUM, LANDMARK" TL, LANDMARK" SOLARIS, LOW AND STANDARD SLOPE LANDMARK n METRIC DIMENSIONS x+(343 mm)---(330 mm)—]—(343 mm)—H 12" 143/4" 17' 1"(25 mm) 1"(25 mm)— 1--(305 mm)—I--(375 mm)---(305 mm)—►� I� - -�- I I—1"(25 mm) fielea a Tape 1"(25 mm)� FA M M 1112" NailableT . Area figure I;;-4:Use fora nails for ererl•full sbiugle. NorthGate: WIDE NNlVO t2' 14 3-4' 12• AREA I+ (305 mm) +r ;375 mm --1305 mm}--j Nair:-r,;s ---V(25 mm) uppe•nallno r:25•n^r— ac } Nailing areas for low and standard slopes(tom 2:12 to 21'121 Nal oetaeen upper d bae'Fes as s•�oan aDo•:e. STEEP SLOPE Use six nails and four spots of aspludi roofing cement for every full LANDMARK n laminated shingle.See below.Asphalt roofing cement should meet KSTM D45861\•pe 11.Apply 1"spots of asphalt roofing cement uncle each corner and at about 12"to 1:3"in from each edge. 131/2" 13" 13112" (313 mm) (330 mm) (343 mm) METRIC DIMENSIONS �1"(25 mm) 1110 mm)--&j I I 143/4" 12 (305 mm) (375 mm) (305 mm) (25 mm) ———— (25 mm) i;iuti�-,;, a^a-t>�cv3. s= �_-sc pRooling Cement 1'(25 mm) ReleaseTape 1"(25 mm) Nail Area For Steep T Figure 13-5:use sir nails and four spots of asphalt mq/ingcement on steep slopes. I (25 mm) ———— (25 mm; Rooting Cement NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate of Authori:ation#32455 6"EDITION(2017)FBC NON-HVH2 EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 8 of 13 NEMO etc. NorthGate: STEEP 12" 14-3!4" 12' SLOPE +(305 mm)—j—(375 mm)-- +(305 mm}--j NAILING ) Nailin Imils AREA 1 Y 1'(25 mm betwee�t.�rtver nal nes, ( ) { oof—Ing ement Nailing areas for steep slopes(greater than 21:12) and"Storm-Nailing" Nail between lower 2 nail lines as shown above. 6.9.1 Hip&Ridge for Landmark'",Landmark'"IR,Landmark—Pro,Landmark'"'Premium,Landmark'"TL, Landmark'"Solaris,Landmark'"Solaris IR,NorthGate: 6.9.1.1 Option 1: Shadow Ridge"or NothGate Accessory 12' 97/g' (305mm) (250mm) Er 6, 415/16"T125mrn) 415H6' (150mm) (i50mm) (125mm Notch for Notch for Gntering Centering 17 131/4' (305mm) Notchas for Alignment to (337mm) des for Alignment to the Top Edge of the Previous 7 the Top Edge of the Previous 7518' Capfor5'(t25mm)Exposure(1 m) Captor55/8'(141mm)EKP_( ) English Dimension !Metric Dbnmion Shadow Ridge'" Shadow Ridge- 9 27:32' (268 mm) 415.16'(125 mm( 131/8" II-..e--(333 mm)� Comenng Notch I6 sl8`►I-6 5/e'► I (168 mm)I 168 mm 131 14' / 1 (337 mm) \ Align thea / ? Centering — rotches to lop 7 S. 13 1/4' Notch edge u' (194 mm) (337 mm) Align these previous course notches to to 7 5/ P edge of ( mm m) previous course. NorthGate Ridge NorthGate Accessory NEMO ETC,LLC Evaluation Report 3532.09.05-R34 Certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 9 of 13 (305a'a') Laying Notch ONEMOletc. I I I � I I Figure 13-20.-Use laying notches to center shhrglss on hips and ridges,and to locate the correct exposure. 6.9.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic® NP7"" adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. 6.9.1.3 Option 2: Refer to instructions herein for Cedar Crest`,Cedar Crest`"IR hip and ridge shingles. t PRESIDENTIAL SHAKE'",PRESIDENTIAL SHAKE'"IR,PRESIDENTIAL SHAKE TLTm,PRESIDENTIAL SOLARIS'm: LOW AND STANDARD SLOPE: STEEP SLOPE: For low and standard slopes,use five nails for each fall Presldenlial For steep slopes,use nine nails for each full Presidential shingle and shingle as shown below. apply 1'diameter spots of asphalt roofing cement under each shingle tab. After applying 5 nails in between the nailing guide lines,apply 4 nabs 1' Nailing 40' +I above tab cutouts making certain tabs of overlying shingle corer nails Guide Lines (1016 mm) 51/4' (133 mn) • • • • 141/4" IL- 11/2' 38 mm) (362 mm) NOTE:Apply nails on painted guideline. Figure 16-6•Fastening Ptnsiden"and Presidenttat TL Shake V diameter asphalt roofing cement shingles on low and standard slopes. Figure 16-7 Fastening Presidential and Presidential TIL Shake Shingles on steep slopes. 6.10.1 Hip&Ridge for Presidential Shake",Presidential Shake'"IR,Presidential Shake TLT",Presidential Solaris": 6.10.1.1 Option 1:Presidential Accessory PRESIDENTIAL ACCESSORY Presidential accessory shingles can be used for covering hips and ridges.Apply shingles up to the ridge (expose no more than 7'from the bottom edge of the"tooth."Fasten each accessory with two fas- teners.The fasteners must be 13/4'long or longer,so they penetrate either 3/4'into the deck or completely through the deck.Presidential accessory comes in two different sizes:Accessory produced in Birmingham,AL is 12'x 12';Portland,OR produces 97/8"x 131/4' accessory. 6.10.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic® NPI"" adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 10 of 13 ONEMOjetc. 6.10.1.3 Option 2:Refer to instructions herein for Cedar Crest'",Cedar Crest"IR hip and ridge shingles. 6.11 HATTERAS": LOV4 STANDARD AND STEEP SLOPE: 7 —q 7 e (230 mm) 1730 mm) (230 mm) (230 mm) I. (230 mm) 1230 mm) (230 mm) (230 mm) I i f - �(25m_) _ __25mm)-1 r—(25 mm) _ __(25 mm)+I [240mm) 0��� t L- - -Rodiap Cemenl�, --- ^1 (240 mm) I figure 15-1.Frcuenng Hnffrms.Shingles on.uerp.Vo/ws For sleep slolics.nx•Gr nails and eight spots of asiph:Ji roofing Figure 15-1 hislening Hatteras 3bifgles on cesanin for each fill tlaneras shingle as shown above-apple I' Lore and.4lanelard.Vopes (LSnun)diameter spots of roofing cement(Atirhi D 1586 Ape n For ba and slandnrd slopes,use fire RAS for each(n0 suggested)under each tab corner.Press shingle into Place;(to na Ilmtenis shinglez shorcn above. expose cement, CAUTION:Too much roofing cement can cause shingles to blister. 6.11.1 Hip&Ridge for Hatteras'": 6.11.1.1 Option 1: Accessory for Hatteras Fasten both sides 1 Rimini WROAM t I ` 1 1 2 Figure 15-14:18 tbreepiece units separate to make 54 Hatteras Accessory sbingi tes. 6.11.1.2 Option 2: Cut Hatteras Shingles 9,— (230 mm)I m 1a� Fos»` I 8" 1g"(460 m ) goit� (203 Tim) �� S`d 25mc�1 -- ------ -- 4fi0mm) ��, Cap Cap Cap Cap Shingle Shingle Shingle Shingle �93� �2 Figure 15-20.•Cut Hatteras shingles to make cover cap. Figure 15-21:InstaWion of caps atong bips and ridges. 6.11.1.3 For ASTM D3161,Class F performance use BASF "Sonolastico NPVM"adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. NEMO ETC,LLC Evaluation Report 3532.09.05-R34 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 11 of 13 NEMO I etc. 6.12 HIGHLAND SLATE",HIGHLAND SLATE'"IR: LOW AND STANDARD SLOPE: STEEP SLOPE: q r r r Use FIVE nalls and EIGHT spots of asphalt roofing cement*for each 00 PC—) a>o.ea VM ml fon HlghLwd Slate shingle.For Miami-Dade,SIX sails are required. Apply f'diameter spots of asphalt roofing cement under each tab corner.Asphalt roofing cement meeting ASTM D4586 Type E is suggested. Izao.4 asmml Rs'�.., Manu-Oade requrec SIX nail.(hm nate — in.telkEover cenMr ax abut ea 9 ). 1fam.DeaerpWee ,.Rs,n„) as m.l inYebtl a.er miler alai a.eho.nt -- Roei,p Caeati Figure 11-3.-Use FM nails for every M&vd Stale sbingle. Ffgwe I1-3rt:Use FIVE nads and elgbt spots ofasp"l roofing caumt wdereacb fab cornea 'CAUTION:Excessive use of roofing cement can cause shingles to blister. 6.12.1 Hip&Ridge for Highland Slate'",Highland Slate'"IR:Refer to instructions herein for Cedar Crest'",Cedar Crest'"IR or Shangle Ridge`" hip and ridge shingles. 6.13 • LOW AND STANDARD SLOPE STEEP SLOPE Use FOUR nails for every full shingle localed as shown Mom% Use FOUR oaiL+and four spots of asphalt roofing cement for every full shingle as shaven below.;1sph:dl roolutg cenieni nic"ing ASf M 0-1586 TvI)e II is sugg"ed.Apply 1'(25 nnn)spots of asphall roofing Sealant cement:U Shown. CAUTION:Excescivt use of roofing cement can cause shingles to blWer. �V(25mn) 1'(25 mr)-►' (156 mm) 13-11- --f-- ,�,r �{- �, ------- -- 1333-r) (333:mj (lump) tali manj I'115 i 1156 mN�. .T -- JR••il•p Cement 1—(12-1,1' --I— Nam) 'l' (M) � (AWTO 6.13.1 Hip & Ridge for Patriot": Refer to instructions herein for Cedar Crest'", Cedar Crest" IR, Shadow Ridge'", NorthGate or Shangle Ridge"hip and ridge shingles. 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/11905.2.6.1. NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 12 of 13 NEMO I etc. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 611320-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmann@us.ul.com -END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 3532.09.05-1134 Certificate of Authorizotion#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1113 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 13 of 13