HomeMy WebLinkAboutProduct InformationResidential Electric
Water Professional Classic Water Heaters
1 1
The new degree of comfort.
Professional Classic° electric water heaters are
engineered for longer life - resistored heating
elements and premium grade anode rod
Efficiency
• .90 -.93 UEF
• Isolated tank design reduces
conductive heat loss
• Resistored copper upper element and
resistored Lifeguard"' stainless steel
lower element to prolong anode rod
and tank life
Performance
• FHR: 45 - 67 gallons, based on gallon
capacity
• Recovery: 21 GPH at a 90° F rise
System Sentinel
(Available on selected models)
• Exclusive diagnostic system with
glowing LEDs that verify heating
element operation. LEDs pin point the
exact location of functioning or non-
functioning heating elements
Longer Life
• Premium grade anode rod provides
long-lasting tank protection
Features
• Electric junction box located above
heating elements for easy installation
• Over -temperature protector cuts
off power in excess temperature
situations
• Automatic thermostat keeps water at
desired temperature
Plus...
• Rheemglasa tank lining resists
corrosion and prolongs tank life
• EverKleen" self cleaning device fights
harmful sediment build-up with a
high -velocity spiraling water stream —
helps operating efficiency by saving
energy, money and improving tank life
• Enhanced -flow brass drain valve
• Temperature and pressure relief valve
included
• HUD certified for manufactured
housing and modular construction
• Low lead compliant
Warranty
• 6 -Year limited tank and parts
warranty'
• With ProtectionPlus" the 6 -year limited
tank warranty becomes 10 -year
'See Residential Warranty Certificate for complete
information
Units meet or exceed ANSI requirements and have
been tested according to the AHRI Operations
Manual and D.O.E. procedures. Units meet or
exceed the energy efficiency requirements of
NAECA. ASHRAE standard 90. ICC Code and all
state energy efficiency performance criteria.
Professional Classic
19.9 to 55 -Gallon Capacities
240 Volt AC/Single Phase
Double and Single Element Models
Electric
Af; JJcrnilnlo
See specifications chart on back.
PRIMED IN USA. 05/10 WP FORM NO. PROE RN N R• .0
Residential Electric
' Water I Professional Classic Water Heaters
Professional Classic® Specifications
Unit" Energy Factor and rated galbn capacity based on Department of Energy (DOE) requirements.
DESCRIPTION
FEATURES
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
ENERGY INFO.
T
Y
P
E
NOMINAL
GALLON
CAPACITY
RATEG
GALLON
CAPACITY
MODEL
NUMBER
UEF
MST HOUR
RATING
G.PA.
RECOVERY
IN Gi
By FRURE
TANK
HEWHT
A
HEIGHTTO
WATER CONN.
B
DMMETER
C
APPRGS.
wpm,
CUBS
UNIFORM
ENERGY
FAOFOR
IUEn
Tall
30
27
PROE30 T2 RH951
46
21
47-1/2
50-3/8
19-1/4
92
0.92
Tall
40
36
PROE40 T2 RH961
55
21
60-3/4
63-5/8
19-1/4
109
0.93
Tall
50
45
PROE50 T2 1
63
21
58-5/8
61-5/8
20-1/4
121
0.93
Tall
55
55
PROE55 T2 SH947
72
21
57
59-3/4
22-1/4
128
0.92
Mad.
30
27
PROE30 M2 1
45
21
37-1/2
40-1/2
20-1/4
92
0.90
Med.
40
36
PROE40 M2 RH95'
55
21 1
48.1/4
50-1/2
20-1/4
106
1 0.93
Med.
50
45
PROE50 M2 RH95'
48
50-1/2
23
132
0.93
Shod
19.9
-
PgOE20 S2 RH31-1/2
31-1/2
17
62
-
Shon
28
25
PROE28 S2 RH95
30
31-1/8
23
95
0.92
ShoN
30
27
PROE30 S2 RH95 B--
&4621
30-1/8
32
19-3/4
95
0.92
ShoA
36
33
PROE36 S2 RH95
31-1/2'
33
24-1/4
118
0.92
35
PROE38 S2 RH951
31-1/2
32 -SM
23
10B
0.92
43
PROE47 S2 RH95
32
34
211/4
149
0.93
Unit" Energy Factor and rated galbn capacity based on Department of Energy (DOE) requirements.
I` System Sentinel optional. Add ECt to the end of the model number. System Sentinel not available on single
element models, available on dual element modals only. System Sentinel not available in excess of 5 kW on
208 V models.
" Water heater dimensions pror to instalirg insulator, blanket that is nduded With water healer.
• Hearns tarnished with sh"i 240 vol AC. angle phase Iran-vanulaneous wiring, and 4500 Watt upper and ower ha rutg
elements.
HOI
• N heading elements of different wattages than those shown am demanded by zone requirements, they must be
WATE
specifically requited.
CONNEC
• Single ekme t moose aviv ie on sin i order (601 max.). Substitute'1- for -2' n model number.
• Special Wring Options - A limled number of special wiring options are avasa le. Consul factory for price and ava0aLul4Y
RELIEF
• All models equpped with heat traps.
CONNE
Recovery = wanege/2.42 x f er p, ,TO °F.
Example: 450OW =21 GPH
2.42 x 90°
Recovery calculations used are basic on 4500 wan elements used in non-sinnU aneous opeaticm.
ROD
�— C —►
DIAMETER
i
A 0
B
WATER CONNECTIONS ALL 3/4" N.P.T.
In keeping with its policy of continuous progress and product improvement. Rheem reserves the right to make changes without notice.
Rheem Water Heating • 1115 Northmeadow, Parkway, Suite 100
Roswell, Georgia 30076 • www.rheem.com
PRINTED IN U.S.A. 05/10 WP FORM NO. PAOE RH N Rev. a