HomeMy WebLinkAboutEngineering FLO A ENGINEERING & TESTING, .INC. Phone: (866)781-6889 •Fax: (866) 784-8550 www.floiidaenginec!ringandtesting.com 250 S.W.13"'A-v enue Pompano Beach,FL 33069 DATE: 10/23/18 JOB ORDER#: 18-4689 CLIENT: All Area Roofing ADDRESS: 3921 S. US Highway 1 Fort Pierce,Florida 34982 PROJECT: Tammy Ogden Residence Integrity Metals 5V Crimp Roof Panel ADDRESS: 204 Smallwood Avenue Fort Pierce,Florida 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS Project Information: Mean Height=Max. 15' Exposure: C Basic/Ultimate Wind Speed: Vuit=165 mph Length= 72' Category: II Nominal Wind Speed: V.d=Vuit*q0.6 Width= 36' Slope: 6/12=26.5° (asd=allowable strength design) Parapet Wall: N/A Residential KZ=0.85,Kzt= 1.0, Kd=0.85 Design Calculations: Velocity Pressure: q= 0.00256*KZKztKdV2 Velocity Pressure (,,It): q=0.00256(0.85)(1.0)(0.85)(165)2] =50.36 psf Velocity Pressure (aid): q=0.00256(0.85)(1.0)(0.85)(165* 0.6)2] =30.21 psf Width of Pressure Coefficient: 0.1(36') = 3.6' 0.4(15') = 6.0' } use: 4'0" Effective Wind Area: <1 W External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP 1 = -0.9 1) GCP; = 0.18 2) GCP2 = -1.7 3) GCP3 = -2.6 Design Pressures Based on Vasd: 1) Field P1 = 3 0.21*[(-0.9)—(0.18)] =-32.6 psf 2) Perimeter P2 = 30.21*[(-1.7)—(0.18)] =-56.8 psf 3) Corners P3 = 30.21*[(-2.6)—(0.18)] =-84.0 psf f V,Q `v Quality' �\3A IV, Page 2,10/23/18,Job Order#18-4689 All Area Roofing F1,0R1X3A Tammy Ogden Residence Integrity Metals 5V Crimp Roof Panel 204 Smallwood Avenue;Fort Pierce,FL: ' Attachment Requirements: Based on the requirements of Florida Product Approval # FL27150.8 with maximum design pressures of -63.5psf (Method 1) and -86psf (Method 2); the following are our recommended fastening patterns to attach the min. 26 ga. 5V Crimp Roof Panels (24" max. coverage) to the min. 15/32", plywood deck (attached to structural supports per product appoval) with # 10 x 1-1/2" HiLo HWH fasteners with weather seal washer at each seam and intermediate rib: Area Field & Perimeter Corner (Method 1) (Method 2) Design Pressure -63.5psf -86psf Fastener Row Spacing 16" O.C. 12"o.c. (Max.) Notes: Corners and perimeter (edge, hip, & ridge) area dimension shall not be less than a = 4'0" (Zone 2: Perimeter (including along ridges) is a 4'0" wide strip, Zone 3: Corners are 410" x 41011) Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty(as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, 2017 FBC, and information provided by client. Client is responsible for verifying existing conditions as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely, `N�Pp%11 I I J I NX El 1p- Al N0. 48202 Mark A. Mesiari�,J;$. Florida Engineer Te§t�MM. Florida Reg.No. Certificate of N-1--, 11/PI1e1%aX