AAMA
(Validator Operations Administrator) CERTIFICATION PROGRAM
AUTHORIZATION FOR PRODUCT CERTIFICATION
- Simonton Windows
1 Cochrane Dr.
Pennsboro,WV 26415
i
Attn: Tina Seese
This authorization is based on the successful completion of tests, and the reporting to the AAMA Validator of the results of the tests by an
AAMA Accredited Laboratory.The product information below will be added to the next update of the AAMA Certified Products Directory.
SPECIFICATIONS
AAMA/WDMA/CSA 101fi.S.2/A440-08 RECORD OF PRODUCT TESTED
R-PG55-1346x1930(53x76)-H AAMA 506
Negative Design,Pressure=-60 psf
i
COMPANY AND CODE Missile Level:D CPD SERIES MODEL-&PRODUCT MAXIMUM SIZE TESTED
Rating:+55/-60,53x76
NO. DESCRIPTION
Wind Zone:4
07-09107-20
Rating above conforms STORMBREAKER PLUS DH
Simonton Windows to the requirements of: (PVC)(X/X)(OG) FRAME SASH fmm)
11730 1346 X 1993030 1267 X946
Code:SIM ASTM E1886 (INS 0.105„ PVB LAM GL)
and E1996 (MODIF)(REINF)(TILT) (4'S”x 6'4'� (4'2"x Ti
(ASTM)
This Certificatiori will expire November 6,2022(extended from November 6,2017 per AAMA 103-15)and requires validation
until then by continued listing in the current AAMA Certified Products Directory.
Structural Test&Report By: Missile Impact Test&Report By:
Architectural Testing,Inc. Architectural Testing,Inc.,
Report No: D0965.01-501-47 Report No: D8120.01-109-47;ref.D0964.01-501-47
Date of Report: November 15,2013 Date of Report: June 10,2014;November 15,2013
'
Evaluated for Certification: April 26,2017
h, 4-4-
Tolcited Laboratories,Inc.
Authorized for Certification: Aprf126,2017
JGS/JTS 0
..�`J �"`�
ACP-14 (Rev.6/16) Ame n Architectural Manufacturers Association
)EL DESIGNATION: Simonton Double Hun 07-10 07-20 Vin Impact `4,����410RE11 �� � REVISIONS: REVISED BYDATE
Hung Series 07-09 / yl Window r( 411/3/2017 6 UDPATEO SIZES PER NEW TESTING, T.D.D. 12/17/13
SIMUM OVERALL NOMINAL SIZE: See Size Chart �"rG:'ykC B'MB>'•:PP LUCAS A. TURNER, P.E. 7 UOPATEO FOR MULTIPLE SUBSTRATE TYPES L.A.T. 9/15/14
^ t Tgb 5820.1 A"r FL PE $8201 8 ADDED 93X79 SIZE OP80 L.A,7, 6/30/19
;ICN PRESSURE RATING@ See Size Chart LUCa$ :*; {*: TURNER ENGINEERING &
.#, CONSULTING, INC. 9 ADDED TEST REPORT NUMBER TO NOTE 15, LMH 4/16/17
,BLE CONFIGURATIONS: Turner 1.,03 rirx (COA # 29779) 10 REMOVED PRE-DflILLEO HOLES LMH fo/27/f7
2017-11-03 r�13% 8TATE 01- :41 1239 JABARA AVE.
ckness 13:23+20:00 NORTH PORT, FL 34288
IERAL DESCRIPTION:
through whiThe head, ch the anchol, and side roscrewrpe penetrates 1smbe ore extruded Va minimumC. The )of10.070 i*FS+ A; PH. 941-380-1574
SUBSTRATE MIN. EMBED.,
INSTALLATION BY OTHERS SEE TSL 1,
6° --^{-8" EE TgDGE SHTf 2 — FASTENER, c-N SHT 2
`D SEE TABLE 1, 2m�= INSTALLATION SILICONE CAULK
SHEET 2 W In N FASTENER 1/4" MAX, SHIM
'^ SEE TABLE 1,
SUBSTRATE SHEET 2 INTERIOR
a BY OTHERS w - 04 =
�6 N4l J I— / —
SILICONE CAULK171NTER�I�CR
SILICONE CAULK
�8� ��'
1/4" MAX. SHIM
v 3
SILICONE CAULK
w i SIZE CHART 1 HEAD T JAMB
�d n OVERALL SIZE
TH HEIGHT DP RATING
"H"
53" 76" f50 PSF
53'r76" t55 PSF
37" 84" t60 PSF
M 37" 76" f65 PSF *SPACER
GLAZING COMPOUND
GLORA 898-HIS)
INTERIOR
2 1/8"ANNEALED
OSOLUTIA) (EASTMAN/
1/4" MAX, SHIM 1/a"ANNEALED
SILICONE CAULK�` SILICONE CAULK
SUBSTRATE ❑ —AIR SPACE
BY OTHERS 1/8•ANNEALED
{
—j+'- ' 2 SILL
1" INSULATED ANNEALED IMPACT GLASS
a to WITH 0.105" PVB INTERLAYER
�----"W" MAX. OVERALL FRAME WIDTH
DISCLOSURETATpM NT �SIMON'I ON' B IN0364 10
Thin document is the property of Simonton Windows,which Dimensional Tolerances w I 1n n R' 4 0 B. TE:
M alne all pr rotary and other rights to its sua)wt matter, Unless Otherwise Specified T.D.D. 11/13 Ofi
This dawmonl b provided to the reelplant an the expressed I C001mne Avenue C EO Y: A
dltlon that it Is not to be disclosed,reproduced N whole Pemsboro.WV 261 L5
port,nor used M eon)unetlon oih the tlaslgp mmuracture or Decimals Angles SCAtE: HEEY: APPR D B, DATE:
repair of goods for myons other than Slmonlon Windows
-"- - - - xithaut its consant. This rsolrictian does not limit the RINPA& - - X d:-03 - FIT- - 1 of 2
1plent's rights to ufilire information contained in this XX d: 01 0• 30 min. S fl
document which Is properly obtained lrom another source. INI., TR N T: •XXX t.005 07-09 07-10 07-20 IMPACT DOUBLE HUNG
nTLE:
FlI£:IN0384 ELEYAnON,INSTALLATION DETAILS,STND.GLAZING DETAIL
++*{1Ut=ltilllll �� REV. REVISIONS: REVISED B DATE:
ES: ++,+�1yORE4/•l(✓4�i 11/3/2017 8 UDPATED SIZES PER NEW TESTING. T.D.D. 12/17/13
Is Installation has been evaluated for use In locations adhering to the Texas 8 Florida Building Codes and where pressure requirements �$0--.';•{'CSNS •.;�C�L LUCAS A. TURNER, RE. 7 UOPATED FOR MULTIPLE SUBSTRATE TYPES LA.T. 9/18/14
a determined by ASCE 7 Minimum Design Loads for Buildings and Other Structures do not exceed the design pressure ratings herein,for Ar No $9201 •�� FL PE # 58201
;e outside the H.V.H.Z. TURNER ENGINEERING & e ADDED 53%7e sTZE DPeG L.A.T. 8/30/15
Interior and exterior perimeter surfaces of the window must be caulked. # CONSULTING, INC. s ADDED TEST REPORT NUMBER TO NOTE 15. LMH 4/16/17
Ichor type,size,spacing,and embedment shall be as specified In these drawings. S7A7F OFai. (CoA # 29779) 1O REMOVED_ - LMH tD/z7/n
y 1239 JABARA AVE. 17 AAMA 800,
ichor embedment to substrate shall be beyond wall dressing or stucco.For concrete/CMU openings embedment shall be beyond wood �yOK;a,a V" Zw; NORTH PORT, FL 34288
icks,if used,and Into substrate.Installations to solid concrete-or grout-filled CMU may Include but do not require 1x wood bucks between Q.......�'¢',+` pH, 941-380-1574
•oduct and substrate. Installations to hollow CMU require the use of 1x bucks between product and substrate. <+y �ONpH{ ++`
ood or masonry openings,bucks,and buck fasteners,by othere,shall be properly designed and Installed to transfer wind loads to the
ss
:ructure. Substrates shall meet the minimum strength requirements as shown in Table 1,this sheet. Concrete or masonry substrates
fall not be cranked, I�
Ia responsibility for selection of Simonton products to moot any applicable local laws,building codes,ordinanres,or other safety
qulrements rests solely with the architect,building owner,or contractor. .500"
Ilms are required where gaps of greater than 1/16"exist between opening and frame.Max,shim stark Is 1/4". Shims shall be GLASS BITE GLAZING COMPOUND
ad-bearing and capable of transferring loads to the substrate. (PECORA 898-HIS)
nen used In areas requiring Impact protection,this product DOES NOT REQUIRE the use of approved Impact resistant shutters orother 1/8"ANNEALED
PV8 EASTMAN/SOLUTIA
demo protection. 0.105 ( )
laling end flashing by others should be applied using the ASTM E2112 methodology appropriate for the opening Into which the door is r� 1/8'ANNEALED
aing Installed. Overall water penetration resistance of the Installed product is the responsibility of others.
dazing shall comply with ASTM E 1300 ❑ a (� �—AIR SPACE
or Installatlon to metal substrates,anchors shall be long enough to be fully threaded through the metal thickness with an additional 3/16" t� 1/8"TEMPERED
In. mce beyond.
minimum center-to-renter spacing of 1-1/4"shall be maintained between all Eire Ultracons in any direction.
.11 fasteners penetrating Into pressure treated wood shall be capable of preventing corrosion due to reaction with pressure treatment SPACER
nemlcals. Any dissimilar materials that come Into contact shall be protected to prevent reactions In accordance with code requirements.
,wind load duration factor Cd=1.6 was used for the analysis of wood screws only. 1" INSULATED TEMPERED/ANNEALED IMPACT CLASS
Jlndows shall be constructed as Specified In test reports A8088.01-50147-r0,A9235.01-50b47-r0.A9261.01-501.47-r1, WITH 9,105"PVB INTERLAYER
7745.01-10947-r0,D0296.01-501-47-b,D0862.01-5501-47-r0, D0963.01-50147-r0,00964.01-501-474,D8119.01-109-47-rO, 37" x 76" AND 83" x 76" DOUBLE HUNG (op-nONAL)
0295.01-501-47-b,D8118.01-10947-r0,D8120.01-109.47.and D0965.01-501-47-rO by Architectural Testing,Inc and 7259-10 by
arabaugh Engineering&Testing inc.
Ise 100%pure silicone caulk compliant with AAMA 806 Section 5-Sealant Specifications for use with Arrhitertural Fenestration
roducts. Make sure surfaces are completely free from all old caulk,damaged wood,wood fibers,grease,oil dirt,rust,mold or similar o
Dntaminants.Vacuum and Clean opening surfaces completely.A fully primed surface Is recommended,but not required.Cleaning of all
arfaces should be done the same day of which the silicone caulk is to applied.For more details visit Simonton,com. 500"
Sulk application:recommended air and surface temperatures at the time of application are to be between 40 and 90 degrees F. Insure all GLASS SITE GLAZING COMPOUND
intact surfaces are clean and dry Including the new window(s). Use a backer rod on all Joints>3/4"deep and/or wider than 1/4". (PECORA 896-HIS)
nlshed caulkjolnt should be a minimum of 3/8"deep and make full contact with both the new window and structural opening surfaces. 1/8'ANNEALED
Ilicone caulk should be famed Into Joint or compressed to assure full contact on Toth surfaces and to expel any air pockets. C7 0.090 PVB(EASTMAN/SOLUTIA)
rte-1/8'ANNEALED
1BLE 1: INSTALLATION FASTENERS TABLE
SUBSTRATE - MIN. EMBED MIN, EDGE DIST. AIR SPACE
CONCRETE 2.85 KSI MIN, 3 16" ELCO LILTRACON 1" 1" t—� 1/e"TEMPERED
OL R - 3/16" ELCO ULTRACON 1-1/4" 2 1/2"
ASTM C90
2X MIN. SOUTHERN PINE WOOD 3/16" ELCO ULTRACON 1-3/8" 3/4" SPACER
G=0.55
( SOUTHERN PINE WOOD #10 WOOD SCREW 1-3/8" 3/4°
G MIN.=0.55 1" INSULATED TEMPERED/ANNEALED IMPACT GLASS
G
16 GAUGE 0,060 MIN. STEEL #10-16 IIW ILK5SEE NOTE 11 1/2" WITH 0.090" PVB INTERLAYER
UD 33KSI YIELD SELF-DRILLING SCREW 37" X 84" DOUBLE HUNG (OPTIONALI
1 B ALUM, 6063-T MIN, OR 10 GRADE SEL -TAPPING SEE NOTE 11 1/Z"
1 8" STEEL 36 KSI MIN. DRILLING SC EW
DISCLOSURE STATEMENT �gI1YlONTON" B IN0354 10
This document Is the property.of Simonton Wind-v,which S FlNISF: Dimensional Tolerances {v DR B, q
retells all proprblory and other rights to Its subject matter. ��p Unlace Otherwlee Spealfied w I .• n a w' s n iJ oa
This da 01,PI l is provided to the recipient on the expressed a �MPER: - I Coehnme Avm. T.D.D.T.UMCKa: A :
condition that it N not to be dWdm.A reproduead In whole or Peonsiwm.WV 26115
part,nor used In con)unctlon with the das n,manufacture or Decimals Angles
repel•of goods for an o Other than S Manton Windows SCALE SHEET: PPR D BY:DATE:
wCIL t Ito conaant. This r.utrictF..doe.not limit the - _ - - - X t.D3 FIT __ _2 of 2
re-tont'.rights to utilize idor—tion-,tamed in 01. A A°
document which Is properly obtained from another source. IIS TR NEN: %X t D' 30 min,
%%%t,00055 e7-08 07-10/07-20 IMPACT DOUBLE HUNG
.
TI LE:
FlLE:IN0384 NOTES,ANCHOR TABLE, &OPTIONAL GLAZING DETAILS