HomeMy WebLinkAboutProduct Approval (2) ik
F _
BGS Home tog In User Registration Hot Topics i Submit Surcharge Stats&Facts Publications t FBC Staff i SCIS Site Mapr': Links Search
F (1da
Product Approval
' gSER:'Public User
eWtict Ap�rrv-aatt Menu>Product or Application Search>AAnu kation List>Application Detail RECEIVED
*' + i FL# FL9777-R11 NOVt
1
Application Type Revision O3 2018
Code Version 2017
Application Status Approved Hglin Co41myf Permitting
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorn i ng,com
Technical Representative
Address/Phone/Email
ff Tl
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
C Evaluation Report-Hardcopy Received
LLFlorida Engineer or Architect Name who developed the Zachary R.Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
Validation Checklist-Hardcopy Received
Certificate of Independence FL9777 R11 COI OCR14002 8a 2017 FBC Evaluation eepPrt We�Ithe loc
Non-HVHZ.ndfi
Referenced Standard and Year(of Standard) standard Year
ASTM D 1970 2015
ASTM D 226 2009
ASTM G 155 2005
TAS 103 1995
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method I Option D
Date Submitted 10/11(2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
9777.1 Weatherlock G #Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL97.77 B11 IT. QCR140Q2 t3a 2017 FBC Evaluation Resort
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.odf
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure,N/A Created by Independent Third Party:Yes
other;See evaluation report for limits of use. Evaluation Reports
FL9777 R11 A[- OCRI4002.8a-2017 FBC Evaluation Report
Weatherlock Non-HVHZ&df
Created by Independent Third Party:Yes
9777.2 Weatherl-ock G(High Tear) Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use In HVHZ:No F19777 RIIJI.00R140021a-.2017 FBC Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.od
Impact Resistant:N/A Verified By: Zachary R. Priest PE-74021
Design Pressure;N/A Created by Independent Third Party:Yes
other:See evaluation report for limits of use. Evaluation Reports
F0777 1111 AE OCRI4002.8a.,2M.FBC Evaluation.Rei2or
Weatherlock Non-HVHZ.t)d
Created by Independent Third Party:Yes
9777.3 Weatherlock MAT Waterproofing Underiayment
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL9777 gli II OCRI4002.8b 2017 FBC Evaluation Report
Approved for use outside HVHZ:No Weatherlock HVHZ.t)d
Impact Resistant:N/A Verified By, Zachary R.Priest 74021
Design Pressure:N/A i Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FF 277 R11 AE OCR14002,8b 201-7 FBC Evaluation Report
W atherlock HVHZ,i2d
Created by Independent Third Party:Yes
—----------------------
9777.4 Weatherlock�MAT Waterproofing Underilayment
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL9777 R11 .11.,.00 14002,8a-2017 FDL Evaluation Report
Approved for use outside HVHZ.-Yes Weatherlock Non-HVHZ pdf
Impact Resistant:N/A Verified By,Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9 77 1111 AE OCR,14002,8a 2017 FBC Evaluation Report
�ath-erlock Non-HVHZ.r)d
Created by Independent Third Party:Yes
- — ..........
9777.5 WeatherLock Metalitherproofing Underlayment
Limits of Use Installation Instructions
Approved for use In HVHZ:No 1 77 RSI II QCR14002.8p-2M FBC EvaluationReport
Approved for use outside HVHZ,.Yes Weatherlock Non-HVHZ,pdf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other.See evaluation report for limits of use. Evaluation Reports
FL9777 R11 AE OCR140018a 2017 FBC Evaluglijon,Regort
Weatherlock Non-HVHZ.gdf
Created by Independent Third Party:Yes
9777.6 — �eatherLock.Metal Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL9Z77 1111 11 OCR140QZ,8b.2Ql7FBC Evaluation Rel2ort
Approved for use outside HVHZ:No WeatherIQck.HVHZ.pd.
Impact Resistant.N/A i Verified By: Zachary R. Priest PE-74021
Design Pressure:N/A Created by Independent Third Party,Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R11 AE OCRI4002.8b 2017 FBC Evaluation Report
Weatherlock HVHZ.12df
Created by Independent Third Party:Yes
9777.7T'a pecthetLock Specialty Tile&Metal Weatherproofing Undedayment
- —-I
Limits of Use Installation Instructions
Approved for use in HVHZ:No EL9777R1 1 11 QCR14002.6a 2017 E8Q Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.pd
impact Resistant:N/A Verified By: Zachary R.Priest 74021
Design Pressure:+0/-142.5 Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 1111 AE OCRI4002.8a 2017
Weatherio5;k Non-HVHZ,adf
Created by Independent Third Party:Yes
Contact U 2601 Blair Stone Road,Tallahassee Fl.32399 Phone:850-487-18
The State of Florida is an AA/EEO employer.Copyright 2007-2013.State or Florida,::Privacy Statement*:Accessibility SLALem.ent::Refund StateMen
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.if you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida statutes,effective October 1,2012,licensees licensed under Chapter 455.F.S.must provide the Department with an email address if they have
one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.if you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,
please click hff_e.
Product Approval Accepts,
FROM MW
Ard
Certificate of Authorization No. 29824
CREEK
17520 Edinburgh Drive
Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6'EDITION(2017)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11,2017
1 Owens Gaming Parkway
Toledo,OH 43657
(800)438-7465
www.owenscoming.com
Manufacturing Location: Brentwood,NH
Houston,TX
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category; Roofing
Subcategory: Underlayments
Code Sections: 1504.3.1, 1507.1.1
Properties: Physical properties
REFERENCES
EiAth Report No. Standard Year
PRI Construction Materials Technologies(TST5878) NEI-039-02-01 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) NEI-042-02-01REV2 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) NEI-045-02-01 TAS 903 1995
PRI Construction Materials Technologies(TST5878) NEI-045-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST5878) NEI-053-02-01 TAS 103 1995
PRI Construction Materials Technologies(17ST5878) NEI-053-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST5878) NEI-093-02-02 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-213-02-01 ASTM D 1623 2009
PRI Construction Materials Technologies(TST5878) OCF-237-02-01 UL 1897 2012
PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 4798 2001
PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-253-02-02 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-272-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST5878) OCF-296-02-02 ICC-ES AC 188' 2012
ICC-ES AC 48 2012
PRI Construction Materials Technologies(TST5878) OCF-297-02-01.1 ASTM D 1970 2015
PRI Construction Materials Technologies(rST5878) OCF-318-02-01 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-320-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST5878) OCF-320-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST5878) OCF-321-02-01 ASTM D 1623 2009
PRI Construction Materials-Technologies(TST5878) OCF-322-02-01 UL 1897 2012
PRI Construction Materials Technologies(TST5878) OCF-355-02-01 UL 1897 2012
'Determined to be equivalent to ASTM D 226-09,Type I and II
OCR14002 8a FL9777-R11 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock®Self-Sealing Ice&Water Barriers
TECHNICAL SERVICES,LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock@ G WeatherLock@ G is an ASTM D 1970 self-adhesive underlayment constructed from SBS
(Brentwood,NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq.rolls with nominal dimensions of 3-ft x.66.7-ft.
WeatherLock@ G is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock®Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood,NH or SBS modified asphalt with a fiberglass mat reinforcement The product is supplied in 1-
Houston, TJC) sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock®Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock@ Metal WeatherLock@)Metal is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood,NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq.rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock@ Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLock@ WeatherLock@ Specialty Tile & Metal is an ASTM D 1.970 self-adhesive underlayment
Specialty Tile&Metal constructed from SBS modified asphalt and surfaced with a non-woven polyester fabric.
(Brentwood, NH or The product is supplied in 2.14 sq.rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, 7X)
WeatherLock@ Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be used with
adhered clay or concrete file roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.)or TILE BONDTm Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock@ G(High WeatherLock@ G(High Tear)is a self-adhered,underlayment used as an alternative to
Tear) ASTM D 226,Type I or Type I I roofing felt and ASTM D 1970 self-adhering polymer
(Houston, TX) modified bitumen underlayment. The underlayment is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-ft x 65-ft.
WeatherLock@ G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
OCR14002.8a FL9777-Rl l Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
OWENS CORNING ROOFING AND ASPHALT LLC
CREEK WeatherLock@ Self-Sealing Ice&Water Barriers
TECHNICAL SERVICES,LLC
PRODUCT AppucATION
Min.Roof Slope: 2:12 in accordance with the FBC
Application, All undarlayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be chocked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the undertayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck.The undedayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3"side
laps and minimum 6"end laps staggered min.6-ft.from preceding course. Additionally,if
applying WeatherLock@ Specialty Tile & Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 Inches across the width
of the lap.
It is permissible to back nail the undedayment 12-inches on-center as needed(nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
undedayment). Additionally,WeatherLock@ Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min.Application 40°F;Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety.per FBC Section 1504.9.
Underlayment System No.1—WeatherLock Soecialtv Tile&Metal Only
Roof Deck: Min. 15/32-inch C,DX plywood attached to wood supports spaced a maximum 24"o.c.
Underlayment- Weatherl-ock@ Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-inch 0 fin caps spaced 12" o.c. The- applied
underlayment shall be rolledwith a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.8a FL9777-1111 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
OWENS CORNING ROOFING AND ASPHALT LLCCREEK WeatherLockO Self-Sealing lee&Water Barriers
TECHNICAL SERVICES,LLC
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be property ventilated in accordance with the FBC requirements.
6) All side lap seams shall be Installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others In accordance With FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underlayment shall meet, or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building
Code Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
tt%till I III fill,
R p
��`�ti�� �`��
E N
1A, 2017.10«11
74
No 021 1:
09:06:29
-04'00'
4tJ
STATE OF '
Al Zachary R.Priest,P.E.
":";s" -0 R Florida Registration No.740211
0...... Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC;does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation:
Zachary R.Priest,P.E. does not have,nor will acquire,a financial Interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product
END OF REPORT
OCR14002.8a FL9777-R11 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not
specifically addressed herein.