Loading...
HomeMy WebLinkAboutProduct Approval (3) r t a MIAMI•DADE MIAMI-DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND'ECONOMIC RESO ER 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION RECEIVE® Miami,Florida 33175-2474 T(7 6)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE NO www.miamidade.gov/economy Sun-Tek Manufacturing,Inc. 10303 General Drive ST. Lue[C-QW11tVi Pefrflitting Orlando,FL 32824 - - - - - SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ)• This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in . the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. 0 DESCRIPTION: ISFG Skylight System APPROVAL DOCUMENT: Drawing No. STI-00000298,titled"ISFG", sheet 1 &2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07,2007, signed and sealed by James D. Wells, Jr., P.E., on October 06, 2017, bearing the Miami-Dade County Product Control Renewal stamp with the Notice of Acceptance number and the LU expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series and the following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a.renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse-of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA#17-1023.22 and consists of this page 1, evidence submitted pages E-1, E-2,E-3 &E4, as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A.Makar,P.EE.,,M.S. MIAMMADE COUNTYyj_,� y2/l'/G� NOA No.18-0716.03 Expiration Date: 10/31/2023 11 jot j�/8 Approval Date: 11/01/2018 / / Page 1 V Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#07-0425.04 A. DRAWINGS 1. Drawing No. STI-00000298-SHTIISHT2, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek Manufacturing, Inc, dated 06104107 with last revision dated 08/07107, signed and sealed by James D. Wells, Jr., P.E. B. TESTS (submitted under NOA# 02-0618.06) 1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of"Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-2760-1, 2 & 3, dated 01122/02, signed and sealed by B. Portnoy, P.E. C. CALCULATIONS 1. Anchor Calculations for attachment of skylight to curbing and curbing to decking, dated 08/13/07, signed and sealed by James D. Wells, Jr., P.E. D. MATERIAL CERTIFICATIONS (submitted under NOA#02-0618.06) 1. Test report on Rate of Burning per ASTMD635 of Geon 87416 White 141 Exterior, 0.137 inch,prepared by Commercial Testing Company, Report No. 01- 11293, dated 11/29101, signed by J. Jackson. 2. Test report on Self Ignition Temperature per ASTMD1929 of Geon 87416 White 141 Exterior,prepared by Commercial Testing Company, Report No. 01-11292, dated 11/29101, signed by J. Jackson. E. STATEMENTS (submitted under NOA#02-0618.06) 1. Code compliance letter issued by Product Technology Corporation. on 09127/02, signed and sealed by R. J. Quiroga P.E. F. OTHER 1. NOA renewal request letter issued by Sun-Tek Manufacturing, Inc., dated 08116107, James Feudner. 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#11-0601.02 A. DRAWINGS 1. Drawing No. STI-00000298-SH7-I/SHT2, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek Manufacturing, Inc, dated August 07, 2007, last revision #A dated October 14, 2011, signed and sealed by James D. Wells, Jr., P.E. W. dlzl� elmy A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No.18-0716.03 Expiration Date: 10/31/2023 Approval Date: 11/01/2018 E-1 Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS 1. Test Addendum for Test Report NCTL 210-2760-1, prepared by national Certified Testing Laboratories, dated October 17, 2011, certifying the interlayer thickness, signed by Mark Bennett, Manager of Testing Services. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Permitting, Environment, and Regulatory Affairs (PEP-4). E. MATERIAL CERTIFICATIONS 1. None. 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#12-1011.15 A. DRAWINGS 1. , Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek Manufacturing, Inc, dated August 07, 2007, last revision #A dated May 03, 2012, signed and sealed by James D. Wells, Jr., P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. OTHERS 1. A compliance letter, issued by J&L Wells Consulting LLC, dated 04/25/2012, certify compliance with FBC 2010 edition, signed&sealed by James D. Wells, Jr., P.E. 2. Verification testing to be performed per letter from National Certified Testing Laboratories, dated September 18, 2012, signed by Christopher Bennett. Helmy A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No. 18-0716.03 Expiration Date: 10/31/2023 Approval Date: 11/01/2018 E-2 r ' "i Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#13-1028.05 A. DRAWINGS 1. Drawing No. STI-00000298, titled "ISFG", sheet I & 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07, 2007, last revision #A dated August 15, 2013, signed and sealed by James D. Wells, Jr., P.E., on February 07, 2014. B. TESTS 1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of"Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-3915-01, dated 08/27/2013, signed and sealed by Gerard Ferrara, P.E. C. CALCULATIONS 1. Anchor Calculations for attachment of skylight Model ISFG to Decking, dated 1010312013, signed and sealed by James D. Wells, Jr., P.E. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. Bill of Material and Components Die Drawings. 5. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#15-0513.10 A. DRAWINGS 1. Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07, 2007, last revision #A dated May 04, 2015, signed and sealed by James D. Wells, Jr., P.E., on May 04, 2015. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. V" 1� C,MeImy A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No. 18-0716.03 Expiration Date: 10/31/2023 Approval Date: 11/01/2018 E-3 Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 6. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL# 17-1023.22 A. DRAWINGS 1. Drawing No. STI-00000298, titled "ISFG", sheet I & 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07, 2007, signed and sealed by James D. Wells, Jr., P.E., on October 06, 2018. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. 7. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. None. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. OTHERS 1. A compliance letter, prepared by J&L Wells Consulting LLC, dated June 20, 2018, certify compliance with FBC 2017 edition, signed & sealed by James D. Wells, Jr., P.E. C-Aelmy A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No.18-0716.03 Expiration Date: 10/31/2023 Approval Date: 11/01/2018 E-4 rs PART NAME'ISFG SKYLIGHT ASSEMBLY Z!kDMMVVG\ACAD 2000 DRAWINGS\DADE COUNTY ISrG STI.ODO00298-Si SHEET 12E2 DWG.NO.STI-00000296-SHTI STI-215 DECO COVER 0.075 6063 T6 ALUM �) 17/3211 GLASS BITE 118"OUTBOARD DSB TEMPERED STI 214 DECO RING MITERED AND SILICONE BEDDING(CONTINUOUS) r-116'•INBOARD GLASS DSBTEMPERED WRAP AROUND 0.050 6063 T6 ALUM. STI-6 GLASS GASKET EPDM STI-205 CMG FRAME 0.060 MITERED (CONTINUOUS) S! Co INSULATED AIR SPACE AND WELDED 6063 T6 ALUM. ARGON GAS FILLED 7 STI-401 WOOD LINER 1.16x0.936' (CONTINUOUS) SWIGGLE SPACER(O.6 *8-32 PHILLIPS PAN HD SCREW AND HEX NUT 7 PER LONG SIDE 7 PER SHORT SIDE SILICONE SEAL TOP AND BOTTOM .177 POLYCARSONATE-1HEEr (CONTINUOUS) PALRAM PALSUN U- BUTYL 3 RINGS OF SEALANT STI-300 PVC LINER STI-207 HSF SUB-FRAME MITERED AND BENEATH FLANGE(CONTINUOUS) GEON 87416 WHITE WELDED 0.075 6063 T6 ALUM. I. AROUND PERIMETER OF:FLANGE 141 EXTERIOR "ou CI REVISED up (CONTINUOUS)AND ON TOP OF EACH &1;c0w lyiq.with the Florida L) FLANGE SCREW AIR SPACE OR B?,!ijdii �,C', 3-' ZE DADE COUNTY APPROVED : X 1"PHILLIPS PAN HEAD vii SHINGLES EXPANDED POLYSTYRENE INSULATION Expimi on 0 SCREW, (9)PER SIDE (SEE NOTE qnci\ tte11111111111 Fly, mJ4 )a act Corthrol ism! ROOF DECK rnin+thick DESIGN PRESSURE RATING-/-80 PSF. LARGE MISSILE IMPACT RESISTANCE Engineer of Record .,Ukk SATE OF James D.Wells,Jr.,P.E. j.. Professional Engineer No.53616 NOTE: All(1)ALL ROOFING DETAILS SHALL COMPLY WITH CHAPTER 15 OF THE FLORIDA BUILDING CODE 2017 edition kf,/ Vo C k. //; AL Wells Consulting LLC (2)4"M INIMU M DISTANCE FROM ANGLE LIP TO ROOF 1453 Arbitus Circle SURFACE IS FOR SHINGLE OR B.U.R.WITHOUT wft, 11 Oviedo,Fl.32765 INSULATION.FOR INSULATION AND TILE ROOF A.DD CIP& V 03 TILE HEIGHT AND INSULATION THICKNESS TO 4' (407)495-5489 (3)ANCHORS 70 BE MADE FROM NON-CORROSIVE MATERIAL E*Arption Certificate of Authorization COMPATIBLE WITH ALUMINUM, RAFTER OR TRUSS ,A (4)NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED. to wa No.27162 (5)TESTED TO TAS 201,TAS 202 AND TAS 203. fly REMSONWSIOJREVISION' DUCT NAME: RN MADE ON S4T 2 CF 2 ISFG SUN- EK MANUFACTURING, INC. BY: BSD [DATE: OMM? 11T 1M JDAW 8/1512013 11 DRAWN BY: Awi DATE:08115/201 DWG,No.STI-00000298-SHTI REV. A 10303 GENERAL DRIVE ORLANDO,FL 32824 PART NAME: 'SKYLIGHT PLAN VIEW FILE ME:ZADWG\DVvWCAD 2000 DRAV\ANGS\DADE COUNTY ISFG STI-000 SHEET 2 OF 2 DWG.NO.STI-00000293-SHT2 tl^t54.6 SII-214 DECO RING MITERED AND WRAPPED tip to 5tip 0. AROUNDO.050 6063T6ALUM 4.000 ,8126 4=0--- c, SILICONE BEDDING(CONTINUOUS) STI-216 DECO COVER 0,075 6063 TSALUM 5.8J25 1 58125 ST"GLASS GASKETEPDM OUTBOARD DSB TEMPERED 25 (CONTINUOUS') QSTI-401 WOOD LINER SMGGLESPACrR(062&1 (CONTINUOUS) .2 ARGON GAS FILLED 5.8125 WELDED CORNERS 6083T6 ALUM C, #8-32 X J!"PHILLIPS PAN HD SCREW oG Z AND HEX NUT(7)PER SIDE C:1 A OCINICARD GLASS OSS TEMPERED FASTENERS SKYLIGHT SILICONE SEAL TOP AND BOTTOM(CONTINUOUS) TO DECK#8 X 1-(9)PER SIDE E. STI.207 HSF SUB-FRAME MITERED .'77 POLYCARBONATESHEEr VC� AND WELDED CORNERS 0.075 FALRAM PALSUN ~ '0 2- 6063 TG ALUM 0-1 ISFG 4949 X 0 3 RINGS OF BUTYL SEALANT AIR SPACE OR to BENEATH FLANGE(CONTINUOUS) DADE COUNTY APPROVED < E t, NTINUOUS)AND ON TOP OF EACH in SHINGLES x SYMEfICAL I w FLANGE SCREW C! r— (SEE NO a F4,00 (0 (CC)AROUND PERIMETER OF FLANGE M No 53616 FASTENER 118 X 11 PHILPS PA SUB-FRAME TO FRAME S SCREW(9)PER IO E At'min.protrusion 1 Z) 0Ar E B ROOF DEC m inihickne— OF J RAFTER OR TRUSS FASTENER SCHEDULE SKYLIGHT To(5my 1 tCHEDULE r'MININU[vl LIP TO A 118 X t"PAN HEAD iffl.PAT AM ME TO FRE C. ROOF SURFACE SCREWS 118.32 X 3/4"WITH HEX NUTS DESIGN PRESSURE RATING+1-80 PSF. tip to lip MODEL PER PER PER PER LONG SI DE SHORT SIDE LONG SIDE SHORT SIDE LARGE MISSILE IMPACT RESISTANCE NEngineer of Record �45.54.6 4949 9 9 7 7 NOTE: James D.Wells,Jr.,P.E. $1.5.51$ 4646 a a 7 7 39-5.x6 3349 9 6 7 5 (1)ALL ROOFING DETAILS SHALL COMPLY Professional Engineer No.53616 39-5.306 3333 6 6 5 5 CHAPTER 15 OF THE FLORIDA BUILDING CODE 2017 edition I5M51614 3046 8 6 7 5 (2)4"MINIMUM DISTANCE FROM ANGLE LIP TO ROOF 35.5.36-6 3030 6 6 5 5 SURFACE IS FOR SHINGLE OR B.U.R.VMTHOUT J&Wells Consulting LLC 39.9.5+.5 2649 1 9 5 7 4 1311.5.30S 2533 6 5 5 4 INSULATION.FOR INSULATION AND TILE ROOF ADD 1453 Arbitus Circle 2M5.305 2525 5 5 4 4 TILE HEIGHT AND INSULATION THICKNESS TO 4'. Oviedo, Ff.32765 N2715dIA 2246 8 5 7 4 (3)ANCHORS TO BE MADE FROM NON-CORROSIVE MATERIAL (407)496-5489 27.5.366 2230 6 5 5 4 COMPATIBLE WITH ALUMINUM, 17.6.27.5 2222 5 5 4 4 Certificate of Authorization ZZW43 1 1742 9 4 7 3 (4)NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USE 4 5 (5)TESTED TO TAS 201,TAS 202 AND TAS 203. No.27162 3 19_5.5t6 1 1446 a 4 7 3 155.]5.51 1430 U 4 5 11 3 REVISION DUCT NAME; ISFG SUN-TEK MANUFACTURING, INC. BY, JVw_ DATE. C8119113 By: DAT E: DRAWN BY: JVVF I DATE:10/14/2010 DWG.NO.STI-00000298-SHT2 REV. A 10303 GENERAL DRIVE ORLANDO,FL 32824