Loading...
HomeMy WebLinkAboutProduct Approval 'r X i-ILE EXTERIOR RESEARCH &DESIGN, LLC. Certificate of Authorization 119503 QOTRINITY 'ERD 353 CHRISTIAN STREET, UNIT OXFORD,CT 06478478 RECEIVED (203)262-9245 EVALUATION REPORT Owens Corning NOV 0 12018 Evaluation Report 037940.02.12-R8 One Owens Corning Parkway FL10674-1113 Toledo,OH 43659 ST. Lucie County, Permitting Date of Issuance:02/06/2012 (740)404-7829 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: 1% - Robert J.M.Nieminen,P.E. .3$�Otiat�,�, The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 ^. �!....�" Nieminen,P.E:on 10/09/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. � `�TRINI-ryj ERD ROOFING SYSTEMS EVALUATION: 1, Scnpc: Product Category: Roofing Sub-Category: Asphalt Shingles ' Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6m Edition (2017) Florida Building [ode and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2' STxwDxnos: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM Q3462 2010 1507l7.1,Re052.6.1 Wind Resistance ASTM Da16z 2016 1507.2.7A,R905.2.6.1 Wind Resistance ASTM D7158 zolz S' RsrsnswcEs: Entity Examination Reference Date ULLLC<csRgs2s> Physicals&Wind Resistance File nz4s3'Vol.s 02/15/2007 oLLLC(csn9o2a) Physicals&Wind Resistance 20120516-R2*53 05/16/2012 ULLLC(TsT96ZD) Physical Properties 06CA20263 04V18/2006 uLLLC(T3T9sZD) Wind Resistance zI[A34308 02/18/2012 ULLLC(T3T9G2O) Physicals QWind Resistance 4786099137 02/01/2014 ULLLC(TST96ZO) Wind Resistance 4786126532 02/10/2014 oLLLC(TsT9628) Physical Properties Classification letter 02/1$2014 ULLLC(TST9aZD) Physical Properties Classification letter 10/02/2015 Miami-Dade(CEn15sz) rDCHVHZCompliance VahousNOA, Various UL LLC <QUA9626> Quality Control Service Confirmation Exp.05/16/2020 4' PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic*and Supreme'are fiberglass reinforced,]-tabasphalt roof shingles. 4.1.2 Berkshire..are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire T11 are fiberglass reinforced,5-tabasphalt roof shingles, 4.1.4 Duration', 7iuDefinit|on^ Duration', Duration' Premium Cool, TruDe�nition~ Duration' Designer Color Collection, TroDe�nition^Oakridge,, Oakridge~ and VVeatherGuard^ HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shingles: 4.2.1 Berkshire' Hip & Ridge Shingles, High Ridge, VVeatherGuard^ HP Hip & Ridge Shingles, PrnE6ge Hip & Ridge Shingles and DuraRidge'm Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4'3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S' L{w/n,T|oNs: 5.1 This is a building code evaluation. NeitherThnity(ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project onwhich this Evaluation Report,orprevious versions thereof,is/was used for permitting ordesign guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FB[HVHZjuhsdictinns. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings ofthis product. Exterior Research and Design,LLC. Evaluation Report o3/y«o.oz.z2-no Certificate Ofx"m"a,"u""#95'o o"EDITION(2on)FSC mom'*vxzEVALUATION ro0674-x13 Owens Corning Asphalt Roof Shingles Revision a:z0/o91zo1, Page zo(u \" ' TRINITY I ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (V,,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd= 150 mph (V„it= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: Berkshire®shingles require minimum five(5) nails per shingle. i WeatherGuarde HP shingles require minimum six(6)nails per shingle. Devonshire'"'shingles require minimum six(6)nails per shingle. Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing–Starter Strip Shingle and Starter Strip Plus: Felt undedayment / Deck Felt undertayment Deck Self-adhered W Self-adheredeatherLockr9undedayment WeatherLocN i underlayment Dripedge Drip— Drip edge Drip— g edge Nails locatedNags located 2't--3"from eave 2'-3'from save Install first Self-sealing adhesive Self sealing adhes ve Starter Strip tnstal first Starter Strip Plus shingle with positioned along gave with V mmoved Positioned olong cave 6"removed " `\ Starter Strip shingle overhangs eaves and rakes'/i'3'i Starter S Plus overhangs eaves and rakes 7/4'-3/4" Exterior Research and Design,I.I.C. a Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 ' a �J\f-RINITY1 ERD 6.2.6 Minimum Nailing—Classic &Supreme: F Mansard or Area pars Normal Mansard or Area parrHigh Wind desvanas y Wind Areas High Wind desvenes y ientos normales Areas vlerrtos tuartes Area para vientos normales Areas viontos tuertes 5 5/8'Exposure n Expositi6n 6.2.7 Minimum Nailing—Berkshires': Sealant Strip sealant strip La lka de s4adar La Li a de sallador f' l"J 1 �• J Standard Fastening Pattern 6-Nail Fastening Pattern Sealant S4 La tks de s0ledar R•�——r s t—s• •�----s s+——s• t"8Yf 8 y 8V 8W s 1" t Asplwkroolmgoetrient Cemeoto de lec de astatto Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118 Certificate oJAuthorization1#9503 6"'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 I fTRINITY�ERD 6.2.8 Minimum Nailing—Devonshire TIM 1" 7" I g„ I 8" t__8L-1 7 1 N gtrvtn Nails 5-5/8'exposure Exposicibn de 5"5/8 ping Sealant locatlDn Ubicac&del sellador s,• ss •R Ten 1'Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern m 6.2.9 Minimum Nailing — Duration°, TruDefinition° Duration, Duration' Premium Cool & Tru Definition Duration"Designer Color Collection: 4-Nall Fastening Pattern 6-Nall Fastening Pattem S,aeNa11A fa!IlMng dna width S—NW!M fastening dna width Nan,Typinal Nan•Typical I; fr Tr r r fr I r it r .p..•.c..ae w.n,r_ r,• -vw .-;..::,a� a..wr•.,•:..�, :s...,v..o..w.q--,-�-:---tw,.a.»w _# •�.v..,,,..w::... ' i �'Yi 1? -{Eat ;s 4"• .4}. i^ t } w a: f- F.. st>e^sem• a ���; �rE�'' tt�:�t. r '.y�_� r vs•dart^ r {.a {{` (,,1�,�. r 't t�i Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 5"'N"faat�Nng—rldd, Nato ryp w r 1r N r 0.fA^S•S2" Y� �'+�V,r .j'4j��].1hf'1' !ri Four 1^Spoh"plWt Rooting C—t Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118 Certificate ofAuthorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 5 of 8 \JTRINITYi ERD 6.2.1 Minimum Nailing—TruDefinition'Oakridge°,Oakridge°: 4 Nail Pattom 6 Nall Pattern Esquema con 4 clavus Esquema con S dams 1' r 6 518"Exposure 5 518"NapsExposure Ezpcsidda ds 6618pufq. Clavas Exparia5n de 6619putg. 5 518"Exposure C�vs 5 6/8'Exposure Erposid6n de 66/8puig. E,tposici6n do 66/8paig. Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 B..N im 1esn ring Man Nrip" 7 ' ..—. .1 z ._ is ' rsv i'spou d A.P t N-5"L.,a.M Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard°HP: �IIXs std side View � fs-- �.`as :{.:'•max'` �'•��� �—___.��-_=� .};r Frrw>I.rTtr:wylt Ilfdl[ii. Cir�iwls,m+rdrl;s fir Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS Certificate ofAuthorization#9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 `,�,I TRINITY ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, WeatherGuard' HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of Duralkidge` Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire'Hip&Ridge and High Ridge: Fig.1 04 Fig.2 <— Pnvdtino Nlnd DiredianT.pViView SideView Nails--� * \ P _TNa1HMIs 4 1 I t —r TaP LarrwaSW t t Race \ A \ qQ I I X, I 1 A I I I j I I Ezprn�ice of VI Iz- 6.3.4 Minimum Nailing—WeatherGuarda HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A 9 4 Top Vbw ProvalliF_Dl=tlonB Yilnd Dlredb n \\ A halls Nalls � A• I I I i I�u � I I Exposure Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118 Certificate ofAuthoriration#9503 6T"EDITION(2017)FBC NON-HVH2 EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 " 4 I a TR1N1TY 1 ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Standard Prevailing Fastening Wind Direction Sealant Strip Pattern 6'Exposure ty 1 Sealant Fasten 71h' Vit' 6'Exposure Cover Expotud 1 Fasteners with I Roof Cement 6.3.6 Minimum Nailing—DuraRidge'" Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Top Yew Prmifng Wird Dirwdan Vue en plan - Dir.Ciondornimntudurnt II. Vlsosuperlor I•I Dimcd.bn del rionte pradtrnironto . 2 I!ti4.';.'k iOiNe_Iu Corning SUteNti_d't�_ aa.o y Qaror� Y I 11 �Iag I 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8