Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online' Page 1 of 2 8CIS Home Log In User Registration Hot Topics I Submit Surcharge Stats&facts Publications ( FBC Staff { BCtS Site Map Links.! Search.i Florida (iibi Product Approval USER:Public User Product Approval Menu>P_roduct or Appticatfon Search>Aootication Lisle>Application Detail. FL# FL18355-114 • Application Type Revision Code Version 2017 7`' Application Status Approved RECEIVED Comments Ai Archived Ell NO Yn1/ ?018 1 ST, WCiq Gqunt:yt PrArmitting Product Manufacturer TAMKO Building Produc , Address/Phone/Email PO Box 1404 Joplin,MO 54602 (417)624-6644 Ext 2305 k6rri_eden@tamko.com Authorized Signature Kerri Eden 4 kerri_eden@tamko.com l Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (4171624-6644 Ext 2305 kerr i_eden@t6mko.com Quality Assurance Representative Address/Phone/Emali Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer CL L�1. Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R.Priest the Evaluation Report _ Florida License PE-74021 Quality Assurance Entity UL L1.0 Quality Assurance Contract Expiration Date 01/07/2019 Validated By Locke Bowden R Validation Checklist-Hardcopy Received Certificate of Independence FLIS355 R4 COI TBP15001 4 2017 FBC Eva[Report Shingles final.12d Referenced Standard and Year(of Standard) Standard Year ASTM D 3161 2016 ASTM D 3462 2010 ASTMD D 7158 2011 TAS 100 1495 Equivalence of Product Standards Certified By Approved Testing Lab' FL18355 R4 Eguly UL letter for standards for FBC 2017.odf Sections from the Code hgsJ/www.floridabuilding.org/pr/prYapp dtl.aspx?param=wGEVXQwtDquvosrHazGXQ... 1/3/2018 -Florida Building Code Online JL dgL,Z U.I. Product Approval Method Method I Option D Date Submitted 09/25/2017 Date Validated 09/27/2017 Date Pending FBC Approval 10/08/2017 Date Approved 12/12/2017 Summary of Products FL# Model,,Number or Name Description 18355.1 _.Glass-Seal,Elite Glass-Seal, ASTM D 3462 asphalt shingles and hfp and ridge shingles Heritage,Heritage Premium, Heritage Woodgate,Heritage Vintage,Hip.and Ridge,and Vintage Hip and Ridge Shingles Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL18355 R4 11 TBP15001.4 2017 FBC Eva]Report Shingles Approved for use outside HVHZ-•Yes final.pd Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluatiorf report for limits of use. Evaluation Reports FL183SS R4 AE TQP15001.4 2017 FBC Eva[Report Shinales final.0 Created by Independent Third Party:Yes Back F----], Contact US:!2601 Blair Stone Road,Tallahassee Fl-32399 Phone:950-487-1824 The State of Florida is an WEED employer.Copyright 2007-2013 State of Florida,::Privacy Statement::Accessibility Statement Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mall address released In response to,a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone orty,traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls,provided may be used for official communication with the licensee:However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available do the public.To determine If you are a licensee under Chapter 455,F.S.,please dick hgM_, Product Approval Accepts. Credit Card Safe https://www.floridabuilding.org/pr/pr, 'a-pi)—dtl.aspx?param=wGEVXQwtDquvosrHazGXQ... 1/3/2018 iff'lar Ceftificate ofAuthorization No.29824 CREEM 17520 Edinburgh Dr Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BuILDING CODE,Sr"EDITION(2017) Manufacturer: TAMKO BUILDING PRODUCTS issued September 25,2017 220 West 4""Street Joplin, MO 64801 (417)624-6644 Manufacturing Plants: Joplin, MO Phillipsburg, KS Frederick,MD Dallas,TX Tuscaloosa,AL Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory; Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1,1523.6.5.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES Enti Report No. Standard Year PRI Construction Materials,Technologies(TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction- Materials Technologies(TST5878) TAP-05"2-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies chnologies(TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials.Technologies(TST5878) TAP-317-02-01 TAS 100 1995 UL LLC(TST9628) 02NK9507 ASTM D 3161 2016 UL LLC(TST9628) 04NK24366 ASTM D 3462 2010A UL LLC(TST9528) 05NK28006 ASTM D 6381 2008(2013)e1 UL 2390 ASTM D 7158 2011 UL LLC..(TST9628) 06NK03898 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 08CA59132 ASTM D 3161 2016 UL LLC(TST9628) 09NK07896 ASTM 1)3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 10CA50498 ASTM 0 3462 2010A UL LLC(TST9628) I0CA64882 ASTM D 3161 2016 UL LLC(TST9628) 11 NK14014 ASTM D 3161 2016 ASTM D-3462 2010A UL LLC(TST9628) 12CA24551 ASTM D 3161 2016 UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)el UL LLC(TST9628) 4787043752 ASTM D 3161 2016 UL LLC(TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC(ANEI 1669) TBP15001.3 Calculations 2017 TBP15001.4 FL18855-R4 Page 1 of i1 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. ���� TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC w PRODUCT DESCRIPTION- Elite Glass-Seal® 12=1/4"x 36",ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab j (Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with i Tuscaloosa) ceramic granules complying with ASTM D 3462. I Glass-Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. i Glass-Seal 12-1/4"x 36',ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. i 7 He13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass .(Dalfas,:Fsederick,., reinforced, laminated architectural asphalt shingle surfaced with mineral granules Jbplin Phillipsburg-& complying with ASTM D 3462. ! "r Tuscaloosa) Heritage®Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, I (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®.Vintage® 17-1/2"x40 ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ,ASTM D 3462. Heritage(D Woodgate 13-1/4" x 39-3/8", ASTM D 31.61, Class F and ASTM D 7158, Class H fiberglass (Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules Complying with ASTM D 3462. Heritage@)Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. i Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt } (Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage@ Hip and Ridge 12" x 12", ASTM D 3161, Class F'fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.4 FL18355-R4 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout-the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS CREEK Asphalt Shingles TECHNICAL SERvicEs,LLC INSTALLATION Elite Glass4eal@ Basic Wind Speed(Vit): Max. 194 mph (Frederick,Joplin& Basic Wind Speed(Vasd): Max. 150 mph Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min, 19/32 in. plywood or wood plank for Glass-Seal new construction; Min. 15/32 in_ plywood existing (Frederick,,Joplin(Non- construction., HVHZ)&Tuscaloosa) Deck(Noriml-IVI-1Z): In accordance with FBC requirements* Solidly sheathed min.on;Min.7/16 i 15/32in. plywood or wood plank for new construction; n.QSB existing construction. cti Underlayment: In accordanZwith FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published.installation instructions. Shingles shall be attached using "6 Nail Pattern' detailed below. Installation (Non-HVHZ): Installed with 5-1/5-inch exposure in accordance with FBC requirements and manufactur6r's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAiLS ........... ........ ............ Nailing - ------ 6-718° Area Butt Edge- Figure 1. Elite Glass-Seal&Glass-Seal 4 Nail Pattern(Non-HVHZ only) NAILS Nailing%—: ......................... ................................. 6-7/8 Area Butt Edge Figure 2. Elite Glass-Seal&Glass-Seal 6 Nail Pdftern TBP15001.4 FL18855-R4 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Service-§,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are,not specifically addressed herein. ����� TAMKO BUILDING PI20DUCTS Asphalt Shingles i I TECHNICAL SERVICES,LLC Heritage@ Basic Wind Speed(Vut): Max. 194 mph (Dallas, Frederick,.Joplin, Basic Wind Speed(Vega): Max. 150 mph Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for HeritageO Premium new construction; Min. 15/32 in. plywood existing (Dallas, Frederick construction. Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 15/32 in. plywood or wood plank for Heritage®Woodgatenew construction; Min.7/16 in.OSB existing construction. j (Dallas&Frederick) Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. ! Installation(HVHZ): Installed with 5-518 in. exposure in accordance with RAS 115 and manufacturers published in instructions. Shingles shall be attached using "B Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in,accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. FASTENERS NAIL ZON E COMMON BOND I EXPOSURE 5-618" 12-112 12-318" 12-112"-� -1" 'I Figure 1 HeritageO, Heritage@ Premium,and Heritage@ Woodgate(Dallas) 4 Nail Pattern (non-HVHZ only) i FASTENERS NAIL ZONE COMMON BOND 6-1� E3+�O7— SURE 5-518" ' 1=-►I �t7-112'=►�+1-7-112"-�-7-318"-�-7-112"-►�-7 1/2"-►� hl-1" Figure 4. Heritage@&Heritage@ Premium 6 Nail Pattern TBP15001.4 FL18355-R4 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed.herein. TAMKO BUILDING PRODUCTS CREEK 1. Asphalt Shingles TECHNICAL SERVICES, L LC i NAIL ZONE! STENERSCOiUlN10N BOND ; EXP(ISURE 5 518" 1" �7-1/2'+7-'U2'+7-3I8+-1/2 7-1/2&� �—V Figure 6. Heritage®Woodgate 6 Nail Pattern j ->l1"i1"—12-1/2" i i i i i i � Common Bond FASTENERS J ; 6 ` cb LOO r T — Figure 6. Heritage®,Heritage®Premium,&Heritage®Woodgate Alternate 6 Nail Pattern PAINT r CINE,, -7f8" a-NAIL ZONE 6-1f8." EDGE OF COMMON BOND EXPOSURE ra-5f8"" ACCEPTABLE. FASTENER LOCATION CO NOT FASTEN ALONG-EDGE OF. -- --- COMMON'B.OND -PREFERRED .FASTENER LOCATION Figure 7. Heritage®(Tuscaloosa) Expanded Nail Zone Nail pafferhs from Figures 3,4,and 6 may be placed in the nail zone as described above TBP15001.4 FL18355-R4 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS CREEK Asphalt Shingles TEckNICAL SIERVICES,LLC Heritage®Ppenfiurn Basic Wind Speed(Vwi): Max. 194 mph (Frederick) Basic Wind Speed(Vasd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in- Plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Undedayment: In accordance with FBC requirements Min.slope-, 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12.. Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published' installation instructions. ,Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published 'installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"ii Nail Pattern"detailed below. NAIL ZONE/ FASTENERS Ct3itttMON BOND T_ 112FP11 5 La 0 SQRE I 1 12 Figure 8. Heritage@ Premium(Frederick) 4 Nail Pattern(non-HVHZ only) NAIL ZONE/ FASTENERS COMMON BOM 7 RE 5" Figure 9. Heritage@ Premium (Frederick) 6 Nail Pattern TBP15001.4FL18265-R4 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLG of any product changes or quality assurance changes throughout the duration for which.this report is valid. This eval6ation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. PRODUCTS 014CREEK TAMKO BUILDINGAsphalt Shingles TECHNICAL SERVICES,LLC Heritage@ Woodgate Basic Wind Speed(Vint): Max. 194 mph (Frederick) Basic Wind Speed(Vasd): Max. 150 mph Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/16.1n.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing thingles at slopes greater than 21:12. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either 44 Nail Paftem"or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS T COMMON BOND T EXPOSURE + 11'. 12-3N' Figure 10. Heritage@ Woodgate(Frederick) 4 Nail Pattern (non-HVHZ only) NAfLZONFJ FASTENERS COMMON BOND Joe �EXPOSURES` Figure 11. Heritage®'Woodgate(Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance Changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS CREEK Asphalt Shingles TECHNICAL SeRvicEs,LLC Heritage(D VintageO. Basic Wind Speed(Vua): Max. 194 mph (Phillipsburg) Basic Wind Speed(Vasil): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. f Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7116 in.0S13 existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBG requirements, Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): 'Installed with 5 in. exposure in accordance with'RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturers published installation instructions. Shingles shall be attached using either"5 Nail Pattern"or"6 Nail Pattern"detailed below. 40' M U9~t -2 IT &posure T Notch 17-V21 V Expcsure Figure 12. Heritage@)Vintage® 6 Nail Pattern(non-HVHZ only) Notch TI Fast*mm N*11 Zone t yrTero - -11(1104 Figure 13. Heritage®Vintage 6 Nail Pattern TBP15001.4 FL18355-R4 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changesthroughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS 11CREEK Asphalt Shingles TF-cHNICAL SERVIcEs,LLC Hip&Ridge Basic Wind Speed(Vtt)* Max. 194 mph (Frederick&Joplin) Basic Wind Speed(Vase): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction;Min.7/16 in.0S13 existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturers published installation-instructions. The direction of the exposed end shall be away from the prevailing wind. Direction of prevailing wind Start 5-1/8" exposure here— Start here Star Figure 1 5-1/8"exposure Fastener Fastener-F Figure 2 Figure'3 Figure 14. Hip&Ridge(Frederick&Joplin) TBP150011.4 FL18355-R4 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule,61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BULDING PRODUCTS CREEK Asphalt'Shingles! TECHNICAL SERVICES,LLC Vintage®Hip 8.Ridge Basic Wind Speed(Vwt): Max. 194 mph (Phillipsburg) Basic Wind Speed(V,,d): Max. 150 mph Deck(HVHZ): 'In accordance with FBC requirements; Solidly sheathed min. 19/32 in, plywood or wood plank for new construction;- Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly'sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/16 in.-OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in,accordance with FBC requirements. Installation: Installed with 5 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction of prevailing wind Start 51' exposure here— Satart here 51' exposure Figure I lot Fastener astener 5-1/2" 1/211 Figure 2 1/4P Figure 3 Figure 16, Vintage®Hip&Ridge(Phillipsburg) TBP15001.4 FL18355-R4 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes Or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply Warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. DING PRODUCTS CREEK TAMKO BUILDING tShingles TECHNICAL SERVICES,LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) rhe mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 60-ft or less. 5) Deck-substrates shall be.clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 611320-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. %J11111111111 R, .-*\GEN& 2017.09.25 1 No 74021 1 :31 :41 U -10 t . -04'00' STATE OF 4U Al Zachary R.Priest, P.E. IS, Florida Registration No.74021 Organization No.ANE1 1669 CERTIFicknom OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor Will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC.is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.'Priest, P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP15001.4 FL18355-R4 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC:of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein.