Archived
it
Product Manufacturer Tri-Built Materials Group,LLC ,
Address/Phone/Email PO Box 70 i' t,p t...-
•Rutherford,NJ 07070 .i
(800)516-1485 I' 1p
. david.ruiz@tribuiltmg.com
L6.1
Authorized Signature David Ruiz - l'
• - • david.ruiz@tribuiltmg.com . ' lI
• Technical Representative I'
Address/Phone/Email ll
. • 1,
Quality Assurance Representative
Address/Phone/Email it -
Category Roofing -
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report-Hardcopy Received
•
Florida Engineer or Architect Name who developed Zachary R.Priest I
• . Report the Evaluation
Florida License • PE-74021 .
Quality Assurance Entity • . Intertek Testing Services NA,Inc. -QA Entity
Quality Assurance Contract Expiration Date 12/31/2020 �.
Validated By - . Locke Bowden P.E.
• 10 Validation Checklist-Hardcopy Received •
• ,i
Certificate of Independence • E121553 R1 COI TBM16Q01,1 2Q1LFBC Eval UaderleyyrLen ipal p iif j
1j •
Referenced Standard and Year(of Standard) Standard Year '
ASTM D 226 2009 - ;I
.
ASTM D 4533 '2015 11
Equivalence of Product Standards ,
Certified By; '
•I
I
Sections from the Code I,
•
•
Product Approval Method Method 1 Option D ' . '
•
••
•
•
Date Submitted 02/21/2018
• Date Validated 02/21/2018 • If
Date Pending FBC Approval 03/13/2018
Date Approved 06/12/2018
• Summary of Products
FL# Model,Number or Name • Description
21553.1 . Tri-Built Materials Synthetic Mechanically attached,woven polypropylene underlayments
Underlayments used as alternatives to ASTM D 226,Type I and Type II.
Limits of Use Installation Instructions •
Approved for use in HVHZ:Yes FL21553 R1 II TBM16001:1 2017 FBC Eva!Underlaymeat
Approved for use outside HVHZ:Yes final.odf
Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021 it • .
•
Design Pressure:N/A Created by Independent Third Party:Yes .
Other:See evaluation report for limits of use. Evaluation Reports
0,2.1.553 Ell AE_TBM16001,1.2017 FBS_.Y_dl�D� aym�Q.l
final.adf !;
Created by Independent Third Party:Yes
•
•
•
•
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovnaht 2007-2013 State of Florida ::privacv Statement::Accessibility Statement::Refund Statement 'i '
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic'
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.°Pursuant to Section 455:275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
• Product ApprovalovAccepts:
Ell r.. ISI
•
Credit Card •
•
• Safe •
•
`S1C irii.VMETI 4S.
•
•
'I.
term
Certificate ofuthorization No. 29824
M A17520 Edinburgh Drive
. !!�� Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480 3421
EVALUATION REPORT FLORIDA BUILDING CODE 6TH EDITION(2017)
Manufacturer: TRI-BUILT Materials Group Issued February 21, 2018
9050 Louisiana Street
Merrillville, IN 46410
(800)516-1485 II
www.tribuiltmaterialsgroup.com
Quality Assurance: Intertek Testing Services(QUA1586)
SCOPE '
Category: Roofing ,,
Subcategory: Underlayments I�
Code Sections: 1507.1.1, 1518.4 ;
Properties: Physical properties ,,
REFERENCES
Entity Report No. Standard Year
Intertek Testing Services(TST1585) 102074565C0Q-004 AC 1881 2012 II
Intertek Testing Services(TST1585) 102074565C0Q-004A AC 1881 2012
Intertek Testing Services(TST1585) 102074565C0Q-007 ASTM D 226 2009 i.
Intertek Testing Services(CER1497) CCRR-1045 IBC,IRC 2012
. PRI Construction Materials Technologies(TST5878) CMI-048-02-01A ASTM D 226 2009 { •
PRI Construction Materials Technologies(TST5878) CMI-048-02-01B ASTM D 226 2009 1
PRI Construction Materials Technologies(TST5878) CMI-048-02-01C ASTM D 226 2009
PRI Construction Materials Technologies(TST5878) CMI-055-02-01 ASMT D 4533 2015
PRI Construction Materials Technologies(TST5878) CMI-056-02-01 ASMT D 4533 2015 I
'Determined to be equivalent to ASTM D 226(2009),Type I and II
PRODUCT DESCRIPTION
Tri-Built Synthetic 10 A mechanically attached, woven polypropylene underlayment (nominal weight = 1.74
Roof Underlayment Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear
strength per ASTM D 4533 of 20 pounds. The underlayment is available in rolls 48-inch
wide by 250-ft long.
Tri-Built Synthetic 25 A mechanically attached, woven polypropylene underlayment (nominal weight = 2.05
Roof Underlayment Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear
strength per ASTM D 4533 of 20 pounds. The underlayment is available in rolls 48-inch '!
wide by long.
.
9
II
Tri-Built Synthetic Plus A mechanically attached, woven polypropylene underlayment (nominal weight = 2.46 ;I
Roof Underlayment Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear ',
strength per ASTM D 4533 of 20 pounds. The underlayment is available in rolls 48-inch
wide by 250-ft long. • l
Tri-Built Synthetic MAX A mechanically attached, woven polypropylene underlayment (nominal weight = 3.69 ,t
Roof Underlayment Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear
strength per ASTM D 4533 of 20 pounds. The underlayment is available in rolls 48-inch I
wide by 250-ft long.
'I
TBM16001.1 FL21553-R1 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
•
• TRI-BUILT MATERIALS GROUP
CRE Synthetic Underlayments
TECHNICAL SERVICES, LLC
APPLICATION INSTRUCTIONS
Deck Type: The roof deck shall be constructed of closely fitted, solid sheathing for new or existing 1
construction. Sheathing shall be installed in accordance with FBC requirements. New
construction in the HVHZ shall be minimum 19/32-inch plywood. Roof decks shall j
have no more than 1/8-inch gap at abutting joints.
•
Attachment method Underlayment shall be attached in accordance with the FBC Table 1507.1.1 and
(non-HVHZ): manufacturer's installation instructions.
Attachment method Underlayment shall.be installed with a minimum 4-inch head lap and minimum 6-inch I{
(HVHZ): end lap and be fastened as specified in FBC Section 1518.2.
Allowable roof coverings Mechanically attached roof systems as prescribed in FBC Section 1507.1.1.
(Non-HVHZ):
Allowable roof coverings Underlayment shall be used with mechanically attached asphalt shingles, metal roof r
(HVHZ): panels and shingles,composite shingles and wood shingles and shakes
•
LIMITATIONS • -
•
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC I;
compliant installation detail shall prevail.
4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck ,•
shall be checked for protrusion and corrected prior to underlayment application.
5) Roof slope limitations shall be in accordance with FBC requirements.
6) All udderlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped ;I
in success courses installed up the deck in a manner that effectively sheds water from the deck. ;i
7) The underlayment may be used as described in other current FBC product approval documents.
8) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically ,!
fastened through the underlayment to the roof deck.
9) The underlayment shall not be installed over existing roof coverings.
10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated. I •
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with j
Rule 61G20-3.
•
•
•
I'
TBM16001.1 FL21553-R1 Page 2 of 3,
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid..
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
•
TRI-BUILT MATERIALS GROUP
CREEKSynthetic Underlayments •
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT .
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code,6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
0•% R.
�� FtY R. p �,
2018.02.21
•
13:42:11
No 74021
N
_•
05'00'
.'
-.:.13% STATE OF '.14/
-
yT•�.;c� Zachary R. Priest, P.E.
�
s C? � Florida Registration No.74021 �
���i�s/0(�Jp'► �,,, Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE .
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC isnot owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
I I
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. 1 p
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
11
11
1J
I
II
• II
END OF REPORT
TBM16001.1 FL21553-R1 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.,
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not..
specifically addressed herein.