NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv
Carlisle Coatings and Waterproofing,Inc.
900 Hensley Lane
Wylie,TX 75098
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this c
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, II
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the ®J
requirements of the applicable building code. NO I
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CCW WIP 100,250 &300 HT Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any p oduct,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 09-0630.13 consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 14-0211.05
MIAMI RADE COUNTY
APPROVED Expiration Date: 08/05/19
Approval Date: 08/06/15
Page 1 of 4
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: SBS
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Manufactured by Dimensions Test Product
Applicant Specification Description
WIP 100 3' x 33' rolls ASTM D 1970 Self-adhering reinforced membrane
Manufacturing 3' x 65' rolls for use as an underlayment in sloped
Location #1 roof assemblies.
WIP 250 3' x 66' rolls ASTM D 1970 Self-adhering reinforced membrane
Manufacturing for use as an underlayment in sloped
Location #1 roof assemblies.
WIP 300 HT 3' x 66' rolls ASTM D 1970 Self-adhering reinforced membrane
Manufacturing for use as an underlayment in sloped
Location #2 roof assemblies.
MANUFACTURING LOCATION
1. Carlisle,PA
2. Terrell,TX
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
Momentum Technologies,Inc. EXO8H2A ASTM D 1970 07/22/03
PRI Construction Materials CCW-019-02-01 ASTM D 1970 11/2014
Technologies CCW-020-02-01 ASTM D 1970 11/20/14
CCW-021-02-01 ASTM D 1970 11/20/14
NOA No.: 14-0211.05
MiAru•oaECouNn
APPROVED Expiration Date: 08/05/19
Approval Date: 08/06/15
Page 2 of 4
APPROVED ASSEMBLIES:
Deck Type 1: Wood,non-insulated
Deck Description: 1932" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck,membrane adhered.
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"side lap and a
6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c.the field of the roll.
Membrane: One or more plies of WIP 100,WIP 250, or WIP 300 HT underlayment with a minimum 4"side
lap and 6"end lap.
Surfacing: Approved Roof Assemblies. See Limitation#3.
I '
NOA No.: 14-0211.05
MIAMI•DADE COUNTY
APPROVED Expiration Date: 08/05/19
Approval Date: 08/06/15
Page 3 of 4
4
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance,with
applicable building code. WIP 100, WIP 250, or WIP 300 HT underlayment shall be installed in strict compliance
with applicable Building Code.
3. WIP 100, WIP 250, or WIP 300 HT underlayment may be used in asphaltic shingles, wood shakes and shingles,
non-structural metal panels, metal shakes and shingles, and quarry slate roof assemblies. WIP 100, WIP 250, or
WIP 300 HT underlayment shall not be used as roof tile underlayment.
4. WIP 100, WIP 250, or WIP 300 HT underlayment shall not be applied over an existing roof membrane as a
recover,but may be applied over a roofing Base/Anchor sheet underlayment.
5. WIP 100,WIP 250, or WIP 300 HT underlayment shall not be left exposed as a temporary roof for longer than 14
days of application.
6. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
7. WIP 100, WIP 250, or WIP 300 HT underlayment may be used with any approved roof covering Notice of
Acceptance listing WIP 100, WIP 250, or WIP 300 HT underlayment as a component part of an assembly in the
Notice of Acceptance. If WIP 100,WIP 250, or WIP 300 HT underlayment is not listed, a request may be made to
the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,
and fire testing results.
8. WIP 100, WIP 250, or WIP 300 HT underlayment shall be applied to a smooth, clean and dry surface with deck
free of irregularities. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose
decking-panels. Sweep the deck thoroughly to remove any dust and debris prior to application.
9. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane
from the center outward in both directions. For ridge applications, center the membrane and roll from the center
outward in both directions.
10. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
12. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of WIP 100, WIP 250, or
WIP 300 HT underlayment shall be applied over the underlayment.
13. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
14. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved"
or the Miami-Dade County Product Control Seal as shown below.
MIAMI•DADE COUNTY
APPROVED
END OF THIS ACCEPTANCE
NOA No.: 14-0211.05
MANMADE COUNTY
APPROVED Expiration Date: 08/05/19
Approval Date: 08/06/15
Page 4 of 4
RECEIVED
NOV 1 9 2018
Permitting Department MIAMI-DADE COUNTY
1' IAND St, Lucie County PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) m.miamidade.gov/economy
Carlisle Coatings and Waterproofing,Inc.
900 Hensley Lane
Wylie,TX 75098
SCOPE: 0
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The 0
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). Liu
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this fircL,
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CCW WIP 100,250&300 HT Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any sectiion
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.09-0630.13 consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
MIAMNI ADE COUNTY AO. NOA No.: 14-0211.05
APPROVED Expiration Date: 08/05/19
Approval Date: 08/06/15
Page 1 of 4
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: SBS
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Manufactured by Dimensions Test Product
Applicant Specification Description
WI?100 3' x 33' rolls ASTM D 1970 Self-adhering reinforced membrane
Manufacturing 3'x 65' rolls for use as an underlayment in sloped
Location#1 roof assemblies.
WIP 250 3' x 66' rolls ASTM D 1970 Self-adhering reinforced membrane'
Manufacturing for use as an underlayment in sloped
Location#1 roof assemblies.
WIP 300 HT 3'x 66' rolls ASTM D 1970 Self-adhering reinforced membrane
Manufacturing for use as an underlayment in sloped
Location#2 roof assemblies.
MANUFACTURING LOCATION
1. Carlisle,PA
2. Terrell, TX
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
Momentum Technologies,Inc. EXO8H2A ASTM D 1970 07/22/03
PRI Construction Materials CCW-019-02-01 ASTM D 1970 11/20/14
Technologies CCW-020-02-01 ASTM D 1970 11/20/14
CCW-021-02-0l ASTM D 1970 11/20/14
NOA No.: 14-0211.05
1 I Aa OT Y
Expiration Date: 08/05/19
APPROVED
Approval Date: 08/06/15
Page 2 of 4
• APPROVED ASSEMBLIES:
Deck Type 1: Wood,non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck,membrane adhered.
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"side lap and a
6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c.the field of the roll.
Membrane: One or more plies of WIP 100,WIP 250,or WIP 300 HT underlayment with a minimum 4"side
lap and 6"end lap.
Surfacing: Approved Roof Assemblies. See Limitation#3,
NOA No.: 14-0211.05
MIAMPDADE COUNTY
Expiration Date: 08/05/19
APPROV D
Approval Date: 08/06/15
Page 3 of 4
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. WIP 100, WIP 250, or WIP 300 HT underlayment shall be installed in strict compliance
with applicable Building Code.
3. WIP 100, WIP 250, or WIP 300 HT underlayment may be used in asphaltic shingles, wood shakes and shingles,
non-structural metal panels, metal shakes and shingles, and quarry slate roof assemblies. WIP 100, WIP 250, or
WIP 300 HT underlayment shall not be used as roof tile underlayment.
4. WIP 100, WIP 250, or WIP 300 HT underlayment shall not be applied over an existing roof membrane as a
recover,but may be applied over a roofing Base/Anchor sheet underlayment.
5. WIP 100, WIP 250, or WIP 300 HT underlayment shall not be left exposed as a temporary roof for longer than 14
days of application.
6. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
7. WIP 100, WIP 250, or WIP 300 HT underlayment may be used with any approved roof covering Notice of
Acceptance listing WIP 100, WIP 250, or WIP 300 HT underlayment as a component part of an assembly inithe
Notice of Acceptance. If WIP 100, WIP 250, or W1P 300 HT underlayment is not listed, a request may be made to
the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance,
and fire testing results.
8. WIP 100, WIP 250, or WIP 300 HT underlayment shall be applied to a smooth, clean and dry surface with deck
free of irregularities. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose
decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application.
9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions. For ridge applications, center the membrane and roll from the center
outward in both directions.
10. Roll or broom the entire membrane surface so as to have 100%contact with the surface, giving special attention to
overlap areas.
11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
12. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shal1 be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of WIP 100, WIP 250, or
WIP 300 HT underlayment shall be applied over the underlayment.
13. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
14. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city
and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved"
or the Miami-Dade County Product Control Seal as shown below.
MIAMI•DADE COUNTY
APPROVED
END OF THIS ACCEPTANCE
Ali
NOA No.: 14-0211.05
MANMADE COUNTY Expiration Date: 08/05/19
APPROVED
Approval Date: 08/06/15