HomeMy WebLinkAboutProduct Approval (2) RECEIVED
MIAMI• NOV 2 / 208 MIAMI-DADE COUNTY
mmamvk I
RODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCJS4aie County, Permitting 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.niianiidade.gov/economv
CertainTeed Corporation E
1400 Union Meeting Road
Blue Bell,PA 19422il L
a'
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Shangle Ridge,Shadow Ridge,Hatteras Accessory,Presidential Accessory,and
Cedar Crest Hip and Ridge Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and thele has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA# 12-0611.02 and consists of pages 1 through 9.
The submitted documentation was reviewed by Alex Tigera.
,. NOA No.: 17-0824.05
MIAMI•DADE COUNTY
.•••� � Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 1 of 9
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials Laminated
Deck Type: Wood
SCOPE
This approves CertainTeed Shangle Ridge, Shadow Ridge,Hatteras Accessory, Presidential Accessory and Cedar
Crest Hip and Ridge Shingles as manufactured by CertainTeed Corporation(PA)and described in Section 2 of this
Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
Shangle Ridge 12"x 18" TAS 110 A pre-assembled,double layer hip and
Manufacturing Location(s) #1 ridge fiberglass reinforced asphalt shingle
with an 8"exposure.
Shadow Ridge 12"x 12" TAS 110 A pre-assembled hip and ridge fiberglass
Manufacturing Location(s) #1,2, 3,4 reinforced asphalt shingle with an 5"
exposure.
Hatteras Accessory 12"x 18" TAS 110 A pre-assembled hip and ridge fiberglass
Manufacturing Location(s) #I reinforced asphalt shingle with an 8"
exposure.
Presidential Accessory 12"x 12" TAS 110 A pre-assembled hip and ridge fiberglass
Manufacturing Location(s) #2 reinforced asphalt shingle with an 5"
exposure.
Cedar Crest 12"x 12" TAS 110 A pre-assembled hip and ridge fiberglass
Manufacturing Location(s) #I reinforced asphalt shingle with an 8"
exposure.
PRODUCTS MANUFACTURED BY OTHERS
Product Product Description Size Manufacturer
Any approved sealant with a current Miami Sealant various Any approved manufacturer
Dade NOA (with a current Miami Dade NOA)
Any approved adhesive with a current ASTM C920,Type S, various Any approved manufacturer
Miami Dade NOA Grade NS,min Class 25 (with a current Miami Dade NOA)
NOA No.: 17-0824.05
MIAMI•DADE COUNTY
• Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 2 of 9
MANUFACTURING LOCATION
1. Oxford,NC.
2. Shakopee,MN.
3. Avery,OH
4. Norwood,MA.
EVIDENCE SUBMITTED
Test Ageney Test Identifier Test Name/Report Date
PRI Asphalt Technologies,Inc. CTC-028-02-01 ASTM D 6381 08/06/07
CTC-021-02-01 TAS 100(A) 05/16/06
CTC-029-02-01 TAS 100(A) 08/06/07
CTC-030-02-01 TAS 100(A) 08/06/07
CTC-020-02-01 TAS 100(A) 05/16/06
CTC-072-02-01 TAS 100(A) 02/10/11
CTC-334-02-01 TAS 107 08/29/17
CTC-330-02-01 TAS 107 08/27/17
CTC-310-02-01 TAS 100(A) 05/31/17
CTC-311-02-01 TAS 100(A) 05/31/17
CTC-312-02-01 TAS 100(A) 05/31/17
CTC-315-02-01 TAS 100(A) 06/19/17
CTC-314-02-01 TAS 100(A) 06/19/17
Underwriters Laboratories,Inc. 07CA30825 ASTM D 3161 08/06/07
R684 ASTM D 3462 08/04/04
R684 ASTM D 3462 08/05/04
1OCA44960 ASTM D 3462 11/11/10
IOCA44960 ASTM D 3161 11/11/10
4787855169 ASTM D 3161/3462 07/27/17
4787855164 ASTM D 3161/3462 06/27/17
4787867612 ASTM D 3161/3462 07/26/17
4787855162 ASTM D 3161/3462 06/26/17
4787855167 ASTM D 3161/3462 06/30/17
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION
1. Ridge Cap Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Layout Details herein
MIAMI-DADE CNOA No.: 17-0824.05
OUNTY
• 1 Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 3 of 9
LABELING
1. Ridge Cap Shingles shall be labeled with the Miami-Dade Seal as seen below,or the wording"Miami-Dade
County Product Control Approved".
MIAMI•DADE COUNTY
, ...�
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
LAYOUT DETAILS
SHANGLE RIDGE
bpossure Remove tape
from the rim Side
and Osten
SECOND '
Nft thee,.
left side RIGHT
FIRS ''
LEFT
NOA No.: 17-0824.05
MIAMI•DADE COUN�IJNTY
•QS Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 4 of 9
SHADOW RIDGE
HATTERAS ACCESSORY
NOA No.: 17-0824.05
MIAMI•DADE COUNTY
F_11=01149 Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 5 of 9
PRESIDENTIAL ACCESSORY
CEDAR CREST
Seat
Sealant
Starter
NOA No.: 17-0824.05
MIAM4DADE COUNTY
•••. Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 6 of 9
NAILING DETAILS
SHANGLE RIDGE
12'
1/4"wide beat[of adhesive,7"tens — �- .—(305 n m))
314"w1" from side edge of cap sHngle
9
(25 ) (26 MM)
f
(d57 rum)
e �
(2i$mea}'
Nailing pattern all applications-two nails per shingle.
SHADOW RIDGE
12,
i/4"wide bead of adhesi�+e,3`-31/2 IOnc, ----. 1(305 mm))
3141 1"frc m side edge of cap shinglo
1 1"
12°
5 5f8, (306 null)
Nailing pattern all applications-two nails per sftle.'
NOA No.: 17-0824.05
MIAMI-DAD:COUNTY Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 7 of 9
HATTERAS ACCESSORY
12"
114"wide bead of adhesive,T long, " ( Mtn _.
a..
3/4"w1"from side edge sof cap shirty
1" 1�
(25 nftm
Rom
.�. .�
18'
a (457 Mt )
(Roe MM)
L i
Nailing pattern all applications-two mails per shingle,
PRESIDENTIAL ACCESSORY
V
114"wide bead of adhosive,T-3112" icing, t8p6 err}
314"-1 from side edge of cap shingle '�-,
t� ly
(2-5 mmp (25 Mm)
12"
5 5/W 1306 MM)
(143
Flailing pallern all applications-two nails per shingle.
QMIAMMI-MADECOUNTY NOA No.: 17-0824.05
Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 8 of 9
CEDAR CREST
1/4"wide bead of adhesive,4"long,
3/4"-1"from side edge of cap shingle
• n,._w, •
�-- 1"(25 mm)
12"
8 5/8" (305 mm)
(219mm)
12' _ J
(305
Nailing pattern all applications -two nails per shingle.
END OF THIS ACCEPTANCE
MIAMIowe couNn NOA No.: 17-0824.05
� Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 9 of 9